DARHT Axis 1 Performance Results with and without a Blumlein Charge Unit

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Axis 1 of DARHT produces a 20- MeV, 2-kA, 80-ns-FWHM electron beam. As DARHT Axis 1 enters its twentieth year of operation, the probability of Blumlein Charge Unit (BCU) failure has increased and the risk of a failure on the day of an explosive experiment has become more likely. Replacement time for a BCU is four to six hours. This report examines the radiographic and beam transport effect of operating the accelerator with a missing or reduced charge voltage BCU. The results are compared with normal, full machine operation. A prescription for alternate operation with missing or reduced charge voltage on BCU22 is given.

47 OTHER INSTRUMENTATION↗

Summary of Results for Idaho Accelerator Center (IAC) Experiments with Compact Electron Permanent Magnet Spectrometer (CEPMS)

The Compact Electron Permanent Magnet Spectrometer (CEPMS) shown in Figure 2 consists of collimation at the electron beam entrance, a vacuum chamber for beam transport and a removable 60 degree sector magnet constructed by SABR Enterprises (Ref 2) that is used to momentum analyze the incoming electron beam. There are electron detection planes located perpendicular to straight through and the 60 degree trajectory ports. The planes are designed to accept phosphor screens for time integrated measurements. The screens can be replaced by scintillator for time resolved measurements using gated or streak cameras. The length of the spectrometer along the beamline without the collimator is about 400mm (14”). The spectrometer requires no power supply with controls for cycling or cooling for the magnet. The entire assembly, with magnet installed, weighs about 35kg (75lbs) Figure 3 depicts central and extreme trajectories through the spectrometer for various electron energies. The chamber accommodates a +/-50mm wide detection field relative to the center trajectory. Trajectories with larger momentum (energy) are bent the least. Since the permanent magnet slides off and on with reference to the upstream edge of the vacuum chamber, it can be adjusted to various positions to slightly increase or decrease the central energy thereby changing the range of available energies. Figure 4 shows the effect of changing the location of the permanent magnet on the electron trajectory. A small inward change in r produces a longer trajectory in the magnet therefore, the same energy trajectory is bent more.

43 PARTICLE ACCELERATORS↗

Optimization of DARHT Axis 1 Injector Voltage

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces a 20- MeV, 2-kA, 80-ns-FWHM electron beam. The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injector electron beam energy. The technique for time resolved measurement of the electron beam energy using electron Permanent Magnet Spectrometer (ePMSpec) has been developed. The electron energy then is used to infer the voltage produced by the injector pulsed power. The injector pulsed power of DARHT I consists of a 1.5-MV, glycol-insulated Blumlein that is pulsecharged by a step-up transformer and switched by four, laser-triggered spark gaps. A series of increasing impedance transmission lines are used to transform the output voltage of the Blumlein to a maximum of 3.8MV at the diode. Figure 1a shows a graphic of the Axis-1 prime power tank, Blumlein and downstream transmission lines. The injector pulse power is designed to produce voltage on a velvet cathode located in the vacuum vessel. The specifications of the voltage-pulse flat-top over 60ns is +/-1%. A key element in the high-voltage circuit is the ethylene glycol Blumlein. The outer volume, adjacent to the laser triggered switches of the Blumlein, is a peaking capacitor. This is an independent volume that contains a mixture of ethylene glycol and water to make it an adjustable capacitor of 380 to 750 pF.

43 PARTICLE ACCELERATORS↗

Re-Analysis of DARHT Axis 2 S4 Magnet Sweep Measurements

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Understanding fundamental properties of the electron beams is essential to optimizing spot size and dose for radiography. This work describes distribution measurements of a single-kicked electron beam (16.5MeV, 1.7kA, 60ns) at a location downstream at imaging station C on DARHT Axis 2. The beam at station C is focused by the S4 solenoid located upstream. The beam distribution is measured by imaging optical transition radiation (OTR) from electrons striking a 51-µm thick titanium foil. This data and analysis were originally published by Ekdahl. The results here are a re-analysis of the asymmetric halo emittance contribution as compared to the emittance resulting from the FWHM of the distribution. This is accomplished using xtr2 fits to the data which include non-linear magnetic field effects in S4. Also examined are the calculated S4 spherical aberration contributions to the emittance using xtr.

43 PARTICLE ACCELERATORS↗

Multidisciplinary Research and Development at the Dual-Axis Radiograph Hydrodynamic Test Facility (DARHT) [Slides]

DARHT is the nation’s premiere flash radiography facility. Flash radiography allows interior views of complex structures that are rapidly moving. DARHT is used to image the implosion of mock weapon assemblies containing surrogate materials. DARHT is the only dual-axis facility in the nation enabling 3D reconstructions, with multi-pulse capability for multiple time points. DARHT is an essential facility for Science-based Stockpile Stewardship at LANL and within the NNSA complex.

43 PARTICLE ACCELERATORS↗

Diamagnetic Loop Testing on DARHT-I

Diamagnetic loops (DML) can be used as a noninvasive method for measurements of beam size in electron beam accelerators that use solenoidal magnetic transport. The loop fundamentally measures the magnetic flux excluded by a diamagnetic object. A comprehensive theory relates the rms beam radius to the excluded flux measured by the DML. We have built, and calibrated a DML apparatus. Recently, this DML has been used to measure the size of the electron beam near the final focus of the DARHT-I flash-radiography accelerator. Results are in agreement with beam transport code predictions. In this article, we review and summarize the construction, calibration, and electron-beam testing of this DML.

43 PARTICLE ACCELERATORS↗

First Results from Diamagnetic Loop Measurements of the DARHT-I Electron Beam [Slides]

Diamagnetic-loop (DML) measurements can inform efforts to improve radiographic resolution. DML is non-invasive, so time-resolved data is available on every shot while tuning or executing a hydrotest. The time-resolved beam size can be deduced from the DML data. LIA beam-transport dynamics affecting beam size can be monitored while testing mitigation measures (e.g., beam halo suppression). Time-resolved beam size at final focus provides immediate information about spot size enlargement due to blur, and effectiveness of mitigation efforts. DML measures magnetic flux produced by a rotating beam, so it also enables monitoring of Larmor emittance that can enlarge the spot size. Beam rotation adds in quadrature with emittance, hence “Larmor emittance." Observing zero bias-field DML flux monitors beam rotation resulting from imperfect nulling of flux linking the cathode, and/or broken LIA transport symmetry (e.g., steering, quads, etc.).

43 PARTICLE ACCELERATORS↗

Beam Envelope Variation due to Space-Charge Neutralization

Our non-invasive, time-resolved diamagnetic loop measurements of beam size during the electron current-pulse flattop at the exit of our 20-MeV linear induction accelerator revealed that the beam size varied by about 13% during the current flattop. This was an unexpected result, since both current and energy were constant during the interval of radius variation. One possible cause, poor vacuum, was investigated using a time resolved envelope equation. It was found that sufficiently high residual-gas pressure in the downstream transport region could result in the observed variation.

43 PARTICLE ACCELERATORS↗

DARHT Axis 1 Bremsstrahlung Dose Measurements

he Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography ca pabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces, nominally, a 20-MeV, 1.5-kA, 80-ns-Full Width at Half Max (FWHM) electron beam. The elec tron beam is focused on to a tantalum target to produce a Bremsstrahlung x-ray dose for flash radiography of dynamic systems. This paper will describe and compare a variety of techniques for determining the x-ray dose for two different beam currents produced by a 55mm and 70mm diameter cathode. The data was taken in November of 2022 on DARHT Axis 1. The experimen tal measurement techniques include a platinum calorimeter, a diamond radiation detector (DRD), and a Compton diode (CD). Gafchromic EBT3 self-developing dosimetry film was also used, but no useful results were obtained. Beam charge and energy were recorded and dose was calculated with this information using xtr with Dosecalcx, and simple dose charge-energy scaling. In this pa per, we will discuss the target geometry and experimental layout, the methods of measuring dose, dose diagnostics and measurement of beam charge and energy, and the comparisons of data and calculations.

43 PARTICLE ACCELERATORS↗

High Intensity Gamma-Ray Source(HIγS) Radiographic Experiments

High Intensity Gamma-ray Source (HIGS) is a Free-Electron Laser (FEL) based Compton back-scattering γ-ray source. The HIGS facility is located on the campus of Duke University and operated by Triangle Universities Nuclear Laboratory (TUNL).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗