Abstract
Our non-invasive, time-resolved diamagnetic loop measurements of beam size during the electron current-pulse flattop at the exit of our 20-MeV linear induction accelerator revealed that the beam size varied by about 13% during the current flattop. This was an unexpected result, since both current and energy were constant during the interval of radius variation. One possible cause, poor vacuum, was investigated using a time resolved envelope equation. It was found that sufficiently high residual-gas pressure in the downstream transport region could result in the observed variation.