Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Root exudates induced coupled carbon and phosphorus cycling in a soil with low phosphorus availability

The amount and type of root exudates can influence P availability in the rhizosphere directly by desorption or dissolution of soil minerals, or indirectly by decomposition of soil organic matter (SOM). Here this study aimed to determine the mechanisms by which specific root exudates influence the distribution and availability of P in soils with low P availability. Water, glucose, alanine, and oxalate were delivered through a simulated root into soils for 15 days. Zymography and planar optodes were used to image potential phosphatase activity, and O2 and pH distribution, respectively. Soils were analyzed for resin extractable inorganic P (Pi), dissolved organic C (DOC), water soluble Fe, and Al, and microbial community structure. Characterization of SOM and P were conducted using ultra-high resolution mass spectrometry and 31P solution nuclear magnetic resonance (NMR), respectively. The addition of oxalate resulted in the greatest resin extractable Pi, DOC, and water-soluble Fe, and Al compared to the other exudates suggesting destabilization of mineral associated organic matter (MAOM) and release of organic P (Po). Both 31P solution NMR and ultra-high resolution mass spectrometry analysis provided evidence of mineralization of Po released from the destabilization of MAOM. The study demonstrates the important role microbial and plant-derived metal chelating ligands play in destabilizing MAOM, releasing SOM and importantly Po, that when mineralized may contribute to increasing Pi availability in soils with low P availability.

59 BASIC BIOLOGICAL SCIENCES↗

Deducing the N- and O-glycosylation profile of the spike protein of novel coronavirus SARS-CoV-2

The current emergence of the novel coronavirus pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) demands the development of new therapeutic strategies to prevent rapid progress of mortalities. The coronavirus spike (S) protein, which facilitates viral attachment, entry and membrane fusion is heavily glycosylated and plays a critical role in the elicitation of the host immune response. The spike protein is comprised of two protein subunits (S1 and S2), which together possess 22 potential N-glycosylation sites. Herein, we report the glycosylation mapping on spike protein subunits S1 and S2 expressed on human cells through high-resolution mass spectrometry. We have characterized the quantitative N-glycosylation profile on spike protein and interestingly, observed unexpected O-glycosylation modifications on the receptor-binding domain of spike protein subunit S1. Even though O-glycosylation has been predicted on the spike protein of SARS-CoV-2, this is the first report of experimental data for both the site of O-glycosylation and identity of the O-glycans attached on the subunit S1. Our data on the N- and O-glycosylation are strengthened by extensive manual interpretation of each glycopeptide spectra in addition to using bioinformatics tools to confirm the complexity of glycosylation in the spike protein. Here, the elucidation of the glycan repertoire on the spike protein provides insights into the viral binding studies and more importantly, propels research toward the development of a suitable vaccine candidate.

59 BASIC BIOLOGICAL SCIENCES↗

Non-traditional stable isotope measurements using laser desorption Orbitrap mass spectrometry: Implications for planetary missions.

Isotopic fractionation recorded in planetary materials provides insights into physical, chemical, and/or potential biological processes occurring on Solar System bodies. As we enter into the next decades of planetary exploration, the crucial information revealed by isotopic compositions of rocky and icy samples mandates that next generation spaceflight instrumentation possess the capability to measure isotope ratios in situ with sufficient precision/accuracy to distinguish between such processes. Here, in addition to identifying and fingerprinting complex organic materials with high accuracy and ultrahigh mass resolutions, laser desorption Orbitrap™ mass spectrometry (LD-O-MS) has the capability to determine the elemental and isotopic composition of solid planetary materials such as rock, regolith, organics, ice, etc. Here, we use a space-qualified LD-O-MS instrument comprising a 266 nm ultraviolet (UV) laser and Orbitrap mass analyzer ruggedized for planetary applications to investigate the stable isotopic composition of Ti and Zn metal plates. Based on the isotopic analyses, we constrain the performance of the CORALS instrument to sub per mille (‰) level accuracy and precision for Ti and at the per mille (‰) level for Zn. An LD-O-MS instrument is a versatile instrument capable of measuring isotopic composition of a variety of planetary samples and would constitute a critical instrument in the exploration of various planetary bodies including but not limited to Moon, Mars, Enceladus and other ocean or icy worlds, Ceres and other asteroids, and comets, thereby answering several high-priority questions pertaining to the formation and evolution of our Solar System.

58 GEOSCIENCES↗

Distinguishing the XUV-induced Coulomb explosion dynamics of iodobenzene using covariance analysis

The primary and secondary fragmentation dynamics of iodobenzene following its ionization at 120 eV were determined using three-dimensional velocity map imaging and covariance analysis. Site-selective iodine 4d ionization was used to populate a range of excited polycationic parent states, which primarily broke apart at the carbon-iodine bond to produce I+ with phenyl or phenyl-like cations (C n H x + or C n H, with n = 1 – 6 and x = 1 – 5). The molecular products were produced with varying degrees of internal excitation and dehydrogenation, leading to stable and unstable outcomes. This further allowed the secondary dynamics of C 6 H x 2+ intermediates to be distinguished using native-frame covariance analysis, which isolated these processes in their own centre-of-mass reference frames. Furthermore, the mass resolution of the imaging mass spectrometer used for these measurements enabled the primary and secondary reaction channels to be specified at the level of individual hydrogen atoms, demonstrating the ability of covariance analysis to comprehensively measure the competing fragmentation channels of aryl cations, including those involving intermediate steps.

74 ATOMIC AND MOLECULAR PHYSICS↗

Investigation of potential polyatomic interferences on uranium isotope ratio measurements for the LS-APGD-Orbitrap MS system

The determination of actinide (e.g., U and Pu) content and isotopics is of importance to the nuclear forensics and safeguards communities. However, in the analysis of environmental samples, such as those collected by the International Atomic Energy Agency, uranium measurements can be complicated by isobaric interferences from polyatomic variants of heavy elements (e.g., Pb). This leads to complex, time-consuming sample manipulations (i.e., separations) before determining isotope ratios. An alternative strategy to sample pretreatment is to use high-resolution mass spectrometric platforms during the analysis to fully resolve the uranium isotopes from potential polyatomic interferences, negating the need for prior chemical separation. The liquid sampling - atmospheric pressure glow discharge (LS-APGD) coupled with an Orbitrap mass spectrometer provides a high-resolution (>70,000 m/Δm at m/z 200) inorganic mass spectrometry platform. Further, as a demonstration of the power of this instrumental platform, and indeed, the high-resolution approach in general, uranium isotope ratios were determined in the presence of elemental impurities (e.g., Pb, Pt, Ta, W) commonly encountered with environmental sample swipe analysis, without any prior treatment. Even at elemental impurity concentrations of 1000–5000× relative to uranium, no interference was observed with the 235 U or 238 U signal. In addition, the 235 U/ 238 U isotope ratio for the samples with the concomitants present are within 2 standard deviations of the values obtained without their addition, indicating that these impurities do not impact the determined uranium isotope ratio. These findings represent a significant first step in leveraging the high resolution of the LS-APGD-Orbitrap-MS to overcome isobaric and molecular interferences instead of relying on chemical separations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry

Instrumental resolution of Fourier transform-charge detection mass spectrometry instruments with electrostatic ion trap detection of individual ions depends on the precision with which ion energy is determined. Energy can be selected using ion optic filters or from harmonic amplitude ratios (HARs) that provide Fellgett’s advantage and eliminate the necessity of ion transmission loss to improve resolution. Unlike the ion energy-filtering method, the resolution of the HAR method increases with charge (improved S/N) and thus with mass. An analysis of the HAR method with current instrumentation indicates that higher resolution can be obtained with the HAR method than the best resolution demonstrated for instruments with energy-selective optics for ions in the low MDa range and above. However, this gain is typically unrealized because the resolution obtainable with molecular systems in this mass range is limited by sample heterogeneity. Here, this phenomenon is illustrated with both tobacco mosaic virus (0.6–2.7 MDa) and AAV9 (3.7–4.7 MDa) samples where mass spectral resolution is limited by the sample, including salt adducts, and not by instrument resolution. Nevertheless, the ratio of full to empty AAV9 capsids and the included genome mass can be accurately obtained in a few minutes from 1× PBS buffer solution and an elution buffer containing 300+ mM nonvolatile content despite extensive adduction and lower resolution. Empty and full capsids adduct similarly indicating that salts encrust the complexes during late stages of droplet evaporation and that mass shifts can be calibrated in order to obtain accurate analyte masses even from highly salty solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scripts and data associated with a manuscript linking soil and sediment elemental composition with dissolved organic matter chemistry across CONUS

This data package provides scripts and geochemical data for a manuscript titled “Linkages between mineral element composition of soils and sediments with hyporheic zone dissolved organic matter chemistry across the contiguous United States” (preprint: doi: 10.22541/essoar.169447343.31694990/v1). This data is associated with the Worldwide Hydrobiogeochemistry Observation Network for Dynamic River Systems (WHONDRS, https://whondrs.pnnl.gov) and is an extension of the Summer 2019 Sampling campaign which crowdsourced samples from rivers and sediment across the continental United States. Data from this study can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1603775 and https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1729719. The main objective of this manuscript was to couple sediment water extractable dissolved organic matter chemistry, defined by ultra-high resolution mass spectrometry, with localized sediment elemental composition and watershed scale soil elemental characteristics. This data package contains one main folder with four subfolders. The main data folder contains (1) readme; (2) data dictionary (dd); (3) file-level metadata (flmd); (4) an R markdown to reproduce manuscript figures and analyses; (5) a pdf of instructions to reproduce NGS interpolations with ArcGIS software; and (6) a python script to reproduce NGS extrapolations with python. The four subfolders contain files required to reproduce NGS extrapolations include (1) ‘CONUS_boundaries’ containing boundary layers (.shp) for the Continental United States; (2) ‘ngs_project’ containing files (.shp) with point level NGS soil elemental data (Grossman et al., 2004); (3) ‘raster_outputs’ containing the interpolated raster output files for various soil elements; and (4) ‘NGS_Chemistry_Final’ contain final extracted soil elemental data.

54 ENVIRONMENTAL SCIENCES↗

Compositional analysis of organosolv poplar lignin by using high-performance liquid chromatography/high-resolution multi-stage tandem mass spectrometry

Organosolv treatment is an efficient and environmentally friendly process to degrade lignin into small compounds. The capability of characterizing the individual compounds in the complex mixtures formed upon organosolv treatment is essential for the optimization of the further lignin conversion processes and for the rational genetic engineering of plants used to produce lignin in order to improve lignin properties. In this study, an organosolv poplar lignin sample was initially analyzed by high-resolution mass spectrometry coupled with negative-ion mode electrospray ionization ((-)ESI HRMS). Lignin monomers and dimers were found to constitute the majority of the compounds in the organosolv lignin sample. Larger lignin oligomers, such as trimers and tetramers, and some not lignin-related compounds, were also detected. A high-performance liquid chromatograph/linear quadrupole ion trap/orbitrap mass spectrometer capable of multi-stage high-resolution tandem mass spectrometry experiments (HRMS n ), equipped with an (-)ESI source (HPLC/(-)ESI HRMS n ), was employed to separate the unknown compounds in the organosolv mixture and to obtain structural information for the deprotonated compounds via collision-activated dissociation (CAD) HRMS n experiments. To improve the understanding of the CAD behavior of deprotonated lignin-related compounds, 16 deprotonated model compounds with different functionalities and linkage types were examined. This approach enabled the assignment of likely structures for several lignin monomers, dimers, trimers, and tetramers, and some not lignin-related compounds, most likely fatty acids. Based on the proposed structures, compounds in the organosolv lignin sample contain β-O-4, 5–5, β-5, and possibly also 4-O-5 linkages. Most compounds contain G- and S-monomeric units although a small amount of H-units were also detected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Storage Conditions of Human Kidney Tissue Sections Affect Spatial Lipidomics Analysis Reproducibility

Lipids often are labile, unstable, and tend to degrade overtime, so it is of the upmost importance to study these molecules in their most native state. In this study, we sought to understand the optimal storage conditions for spatial lipidomic analysis of human kidney tissue sections. Specifically, we evaluated human kidney tissue sections on several different days throughout the span of a week using our established protocol for elucidating lipids using high mass resolution matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI). We studied kidney tissue sections stored under five different conditions: open stored at –80 °C, vacuumed sealed and stored at –80 °C, with matrix preapplied before storage at –80 °C, under a nitrogen atmosphere and stored at –80 °C, and at room temperature in a desiccator. Results were compared to data obtained from kidney tissue sections that were prepared and analyzed immediately after cryosectioning. Data was processed using METASPACE. After a week of storage, the sections stored at room temperature showed the largest amount of lipid degradation, while sections stored under nitrogen and at –80 °C retained the greatest number of overlapping annotations in relation to freshly cut tissue. Overall, we found that molecular degradation of the tissue sections was unavoidable over time, regardless of storage conditions, but storing tissue sections in an inert gas at low temperatures can curtail molecular degradation within tissue sections.

60 APPLIED LIFE SCIENCES↗

Quantifying resolution in cosmological N- body simulations using self-similarity

ABSTRACT We demonstrate that testing for self-similarity in scale-free simulations provides an excellent tool to quantify the resolution at small scales of cosmological N-body simulations. Analysing two-point correlation functions measured in simulations using abacus , we show how observed deviations from self-similarity reveal the range of time and distance scales in which convergence is obtained. While the well-converged scales show accuracy below 1 per cent, our results show that, with a small force softening length, the spatial resolution is essentially determined by the mass resolution. At later times, the lower cut-off scale on convergence evolves in comoving units as a−1/2 (a being the scale factor), consistent with a hypothesis that it is set by two-body collisionality. A corollary of our results is that N-body simulations, particularly at high red-shift, contain a significant spatial range in which clustering appears converged with respect to the time-stepping and force softening but has not actually converged to the physical continuum result. The method developed can be applied to determine the resolution of any clustering statistic and extended to infer resolution limits for non-scale-free simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Molecular imaging of plant-microbe interactions on the Brachypodium seed surface

Plant growth-promoting rhizobacteria (PGPR) play a crucial role in biological control and pathogenic defense on and with-in plant tissues, however the mechanism(s) by which plants associate with PGPR to elicit such beneficial effects needs further study. Here, we present high mass resolution time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging of Brachypodium distachyon (Brachypodium) seeds with and without exposure to two model PGPR, i.e., Gram-negative Pseudomonas fluorescens SBW25::GFP (P.) and Gram-positive Arthrobacter chlorophenolicus A6::GFP (A.). Delayed image extraction was used to image PGPB-treated seed sections to reveal morphological changes. ToF-SIMS spectral compari-son, principal component analysis (PCA), and two-dimensional (2D) imaging show that the selected PGPR have different effects on the host seed surface, resulting in changes in chemical composition and morphology. Metabolite prod-ucts and biomarkers, such as flavonoids, phenolic com-pounds, fatty acids, and indole-3-acetic acid (IAA), were ob-served on the PGPR-treated seed surfaces. These compounds had different distributions on the Brachypodium seed surface for the two PGPR, indicating that the different bacteria elicited distinct responses from the host. Our results illustrate that ToF-SIMS is an effective tool to study plant-microbe interac-tions and to provide insightful information with submicrome-ter lateral resolution of the chemical distributions associated with morphological features, potentially offering a new way to study the mechanisms underlying beneficial roles of PGPR.

PGPR, Brachypodium distachyon, ToF-SIMS, metabolit↗

Picosecond lifetime measurements of resonances using a thick-target invariant-mass technique

Here, a new technique is presented for measuring the half-lives of resonances in the picosecond range using presently available invariant-mass apparatus and a thick target. For short-lived resonances, the energy losses of the decay fragments in the target material change their relative velocities giving rise to a poor invariant-mass resolution. However, for longer-lived resonances that travel through the remaining target material before decaying outside of the target, this dominant contribution to the resolution is eliminated. The measured invariant-mass peak will then display a narrow peak from these events which sits on a wider structure associated with the remaining events that decay in the target. The fraction of the events in the narrow peak is related to the probability that the resonance leaves the target before decaying and hence is related to the lifetime. This technique is exercised for the 2.685-MeV resonance in 33 Cl which decays by emitting an f -wave proton. A half-life of T 1/2 =5.7$^{+4.1}_{-2.5}$ ps was measured which is consistent with values inferred from other known properties of this resonance.

lifetimes & widths↗

Enabling Ultralow Volume Analysis with a High-Resolution Ion Mobility Mass Spectrometry Platform

Of all the molecules thought to exist in the universe, it is estimated that researchers only know the chemical structures of 5% of them. Identifying the chemical structures of the remaining 95% has proven extremely challenging because many molecules exhibit low abundance, are contained in small volumes (e.g., <10 nL), do not readily ionize, exhibit similar structures to other molecules, etc. No single analytical technique exists to definitively identify the structure of an unknown molecule, and thus multiple different molecular measurements are typically made (i.e., multi-modal approach). Ion mobility (IMS) and mass spectrometry (MS) are two key tools that researchers use to determine the chemical structures of unknown molecules, and recently high-resolution and ultrahigh resolution IMS-MS instruments have provided greater confidence than ever before. However, HR-IMS-MS instruments typically exhibit low ion utilization efficiency, meaning they require large amounts of sample for an analysis (e.g., >10 µL). Unfortunately, this limitation prohibits the analysis of small volume samples where many unknown molecules exist. Described herein are the efforts made to enable the analysis of ultralow volumes with an HR-IMS-MS platform. A new scanning technique, termed a ‘stuttered traveling wave scan’, was developed as a replacement for the dual-gated scanning technique and works by halting the traveling waves after allowing ions to separate and then repeatedly restarting and stopping the traveling waves to incrementally move ions from the SLIM to the Orbitrap. Ions were stored inside the SLIM while the TWs were stopped, allowing the Orbitrap to perform high-resolution mass analysis. When the Orbitrap was ready, the TWs were restarted for short periods of time (<10 ms) to move ions from the SLIM to the Orbitrap. It was discovered that lower TW amplitudes and speeds than used during IMS separation were required to produce IMS peaks with the highest signal intensities and best resolving powers. The stuttered TW scan was found to produce similar resolutions and signal intensities compared to the dual-gated scanning technique. A new IMS design possessing an intersecting ‘tee’ with a reversible traveling wave was also developed to improve ion utilization efficiency during cyclic operation, which is necessary when only a single IMS spectrum can be acquired, such as when analyzing ultralow volume samples. The new capabilities described in this report lay the groundwork for acquiring HR-IMS-MS spectra of ultralow volume biological samples, such as single cells, where HR-IMS-MS can help elucidate the structures of unknown compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmospheric Brown Carbon on the Tibetan Plateau: Regional Differences in Chemical Composition and Light Absorption Properties

In this work, fine particulate matter (PM 2.5 ) filter samples were collected from two high-altitude remote sites located in the southern (QOMS) and northern (WLG) regions of the Tibetan Plateau (TP) to explore the regional differences in brown carbon (BrC) properties. Chemical differences in BrC composition representative of these two areas were inferred from molecular-level analysis of the PM 2.5 samples using high-performance liquid chromatography coupled with photodiode array and high-resolution mass spectrometry detectors. The results show that more polar BrC chromophores were abundant in QOMS samples, while contributions from polar and less polar chromophores were comparable in WLG samples. A higher mass absorption coefficient of BrC was observed at QOMS than at WLG. Strong BrC chromophores in QOMS samples were identified as oxygenated aromatics and nitrophenol compounds, while organosulfate compounds were found in the WLG sample. The results of this study indicate regional differences in BrC chromophores and provide insights into their sources and chemical processes, which should be considered for predictive understanding and modeling of the radiative forcing of aerosol in the TP area.

54 ENVIRONMENTAL SCIENCES↗

Chemical Insights into the Molecular Composition of Organic Aerosols in the Urban Region of Houston, Texas

Molecular functional groups, such as organosulfates (CHOS) and organonitrates (CHNO) are important tracers for field observations of secondary organic aerosols (SOA). While CHOS and CHNO are prevalent in the atmosphere, there is a lack of knowledge regarding daily and day- and night-time variations in these species in the urban atmosphere. Meteorological factors such as wind speed/direction, relative humidity (RH), and temperature can influence the formation of CHOS/CHNO. To investigate these trends, we utilized multimodal chemical imaging and advanced high resolution mass spectrometry techniques to acquire particle speciation and molecular formulas (MFs) associated with day and night sampling periods. Back trajectory analyses revealed the oceanic influence of southern wind airmasses in later June sampling periods with organic fractions <10%. Conversely, northern winds in early June sampling periods contributed to the episodic emergence of extremely low volatile organics (ELVOCs) and organic factions up to 41%. The observed unique MFs to June 3 (223 MFs) and to June 4 (144 MFs) were largely found to be of biogenic rather than anthropogenic origin. Finally, our findings reveal episodic prevalence and temporal distribution of SOA constituents across the urban region of Houston, Texas.

54 ENVIRONMENTAL SCIENCES↗