Engineering PapersSearch

SEARCH · Engineering Papers

Results for “LIGHT SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Variable light source with a million-to-one intensity ratio

A wide range, variable intensity light source of constant color characteristics has been developed for testing and calibrating photomultiplier tubes. A light attenuator first diffuses light from a constant source, then permits variable attenuation through a series of chambers and adjustable apertures.

Snow, W. B.

Modeling Geometric Arrangements of TiO2-Based Catalyst Substrates and Isotropic Light Sources to Enhance the Efficiency of a Photocatalystic Oxidation (PCO) Reactor

The closed confined environments of the ISS, as well as in future spacecraft for exploration beyond LEO, provide many challenges to crew health. One such challenge is the availability of a robust, energy efficient, and re-generable air revitalization system that controls trace volatile organic contaminants (VOCs) to levels below a specified spacecraft maximum allowable concentration (SMAC). Photocatalytic oxidation (PCO), which is capable of mineralizing VOCs at room temperature and of accommodating a high volumetric flow, is being evaluated as an alternative trace contaminant control technology. In an architecture of a combined air and water management system, placing a PCO unit before a condensing heat exchanger for humidity control will greatly reduce the organic load into the humidity condensate loop ofthe water processing assembly (WPA) thereby enhancing the life cycle economics ofthe WPA. This targeted application dictates a single pass efficiency of greater than 90% for polar VOCs. ~ Although this target was met in laboratory bench-scaled reactors, no commercial or SBIR-developed prototype PCO units examined to date have achieved this goal. Furthermore, the formation of partial oxidation products (e.g., acetaldehyde) was not eliminated. It is known that single pass efficiency and partial oxidation are strongly dependent upon the contact time and catalyst illumination, hence the requirement for an efficient reactor design. The objective of this study is to maximize the apparent contact time and illuminated catalyst surface area at a given reactor volume and volumetric flow. In this study, a Ti02-based photocatalyst is assumed to be immobilized on porous substrate panels and illumination derived from linear isotropic light sources. Mathematical modeling using computational fluid dynamics (CFD) analyses were performed to investigate the effect of: 1) the geometry and configuration of catalyst-coated substrate panels, 2) porosity of the supporting substrate, and 3) varying the light source and spacing on contact time and illuminated catalyst area.

Richards, Jeffrey T.

Demonstration of a diamond anvil cell platform at the Linac Coherent Light Source: capabilities and outlook

A novel X-ray free electron laser (XFEL) diffraction setup for use with diamond anvil cells (DACs) at the Linac Coherent Light Source (LCLS) is described. The new diamond window at the Matter at Extreme Conditions (MEC) instrument allows hard X-ray experiments on DACs to be performed in air. The platform is described along with alignment and calibration procedures, and details of the X-ray beam and diagnostics. Example data are presented, including a reversible XFEL-induced phase transition in CsPbI 3 . The DAC setup was commissioned at MEC, but is applicable to most LCLS instruments where the unique pulse structures available at LCLS offer access to new ultrafast experimental techniques at high pressure.

Linac Coherent Light Source (LCLS)

Sextupole reduction via chaos suppression at the National Synchrotron Light Source II

We revisit the nonlinear lattice design approach for the National Synchrotron Light Source II (NSLS-II) storage ring. By suppressing chaos, we identify alternative sextupole configurations to the original design, which relied on the conventional strategy of simultaneously minimizing resonance driving terms (RDTs) and amplitude-dependent detuning (ADD). These alternatives achieve comparable performance while requiring fewer sextupoles. A detailed comparison of two representative solutions is presented and supported by experimental validation. Our results show that the dynamic aperture correlates more strongly with global chaos than with individual RDTs, and that the importance of minimizing ADD may have been overstated in earlier design strategies.

36 MATERIALS SCIENCE

ALS-ENABLE: creating synergy and opportunity at the Advanced Light Source synchrotron structural biology beamlines

ALS-ENABLE is an integrated NIH P30 resource at the Advanced Light Source synchrotron at Lawrence Berkeley National Laboratory in Berkeley, California, USA. The resource provides a single portal to the combined mature structural biology technologies of macromolecular crystallography, small-angle X-ray scattering and X-ray footprinting mass spectrometry, and includes beamlines 2.0.1, 3.3.1, 4.2.2, 5.0.1, 5.0.2, 5.0.3, 8.2.1, 8.2.2, 8.3.1 and 12.3.1. This paper describes the organizational structure and the technologies of ALS-ENABLE. A case study showcasing the main technologies of the resource applied to the characterization of the SpyCatcher-SpyTag protein system is presented.

Ralston, Corie Y

Compact fiber-coupled narrowband two-mode squeezed light source

Quantum correlated states of light, such as squeezed states, are a fundamental resource for the development of quantum technologies, as they are needed for applications in quantum metrology, quantum computation, and quantum communications. It is thus critical to develop compact, efficient, and robust sources to generate such states. Here, we report on a compact, narrowband, fiber-coupled source of two-mode squeezed states of light at 795 nm based on four-wave mixing (FWM) in an 85 Rb atomic vapor. The source is designed in a small modular form factor, with two input fiber-coupled beams, the seed and pump beams required for the FWM, and two output fibers, one for each of the modes of the squeezed state. The system is optimized for low pump power (135 mW) to achieve a maximum intensity-difference squeezing of 4.4 dB after the output of fibers at an analysis frequency of 1 MHz. Furthermore, the narrowband nature of the source makes it ideal for atomic-based quantum sensing and quantum networking configurations that rely on atomic quantum memories. Such a source paves the way for a versatile and portable platform for applications in quantum information science.

Jain, Umang [University of Oklahoma, Norman, OK (U

Fresnel cup reflector directs maximum energy from light source

To minimize shielding and overheating, a composite Fresnel cup reflector design directs the maximum energy from a light source. It consists of a uniformly ellipsoidal end surface and an extension comprising a series of confocal ellipsoidal and concentric spherical surfaces.

Laue, E. G.

Diffusion filter eliminates fringe effects of coherent laser light source

Diffusion filter comprised of small particles in colloidal suspension reduces the coherence of a laser beam used as a photographic light source. Interference patterns which obscure details in photographic film are eliminated, the intensity and collimation are moderately affected.

Olsasky, M. J.

Coincident learning for beam-based rf station fault identification using phase information at the SLAC linac coherent light source

Anomalies in radio-frequency (rf) stations can result in unplanned downtime and performance degradation in linear accelerators such as SLAC’s Linac Coherent Light Source (LCLS). Detecting these anomalies is challenging due to the complexity of accelerator systems, high data volume, and scarcity of labeled fault data. Prior work identified faults using beam-based detection, combining rf amplitude and beam position monitor data. Due to the simplicity of the rf amplitude data, classical methods are sufficient to identify faults, but the recall is constrained by the low-frequency and asynchronous characteristics of the data. In this work, we leverage high-frequency, time-synchronous rf phase data to enhance anomaly detection in the LCLS accelerator. Due to the complexity of phase data, classical methods fail, and we instead train deep neural networks within the Coincident Anomaly Detection (CoAD) framework. We find that applying CoAD to phase data detects nearly 3 times as many anomalies as when applied to amplitude data, while achieving broader coverage across rf stations. Furthermore, the rich structure of phase data enables us to cluster anomalies into distinct physical categories. Through the integration of auxiliary system status bits, we link clusters to specific fault signatures, providing additional granularity for uncovering the root cause of faults. We also investigate interpretability via Shapley values, confirming that the learned models focus on the most informative regions of the data and providing insight for cases where the model makes mistakes. This work demonstrates that phase-based anomaly detection for rf stations improves both diagnostic coverage and root cause analysis in accelerator systems and that deep neural networks are essential for effective analysis.

Accelerator Physics (physics.acc-ph)

Demonstration of a diamond anvil cell platform at the Linac Coherent Light Source: Capabilities and Outlook

A novel x-ray free electron laser (XFEL) diffraction setup for use with diamond anvil cells (DACs) at the Linac Coherent Light Source (LCLS) is described. Using the new diamond window at the Matter at Extreme Conditions (MEC) instrument, it allows hard x-ray experiments on DACs to be performed in air. The platform is described along with alignment and calibration procedures and details of the x-ray beam and diagnostics. Example data are presented, including a reversible XFEL induced phase transition in CsPbI3. The DAC setup was commissioned at MEC, but is applicable to most LCLS instruments where the unique pulse structures available at LCLS offer access to new ultrafast experimental techniques at high pressure.

Diamond Anvil Cells, LCLS, XFEL, High-Pressure