Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Emittance preservation for the electron arm in a single PWFA-LC stage using quasi-adiabatic plasma density ramp matching sections

Plasma-based acceleration (PBA) is being considered for a next generation linear collider (LC). In some PBA-LC designs for the electron arm, the extreme beam parameters are expected to trigger background ion motion within the witness beam, which can lead to longitudinally varying nonlinear focusing forces and result in an unacceptable emittance growth of the beam. To mitigate this, we propose to use quasi-adiabatic plasma density ramps as matching sections at the entrance and exit of each stage. We match the witness electron beam to the low density plasma entrance, where the beam initially has a large matched spot size so the ion motion effects are relatively small. As the beam propagates in the plasma density upramp, it is quasi-adiabatically focused, and its distribution maintains a non-Gaussian equilibrium distribution in each longitudinal slice throughout the process, even when severe ion collapse has occurred. This only causes small amounts of slice emittance growth. The phase mixing between slices with different betatron frequencies leads to additional projected emittance growth within the acceleration stage. A density downramp at the exit of an acceleration section can eliminate much of the slice and projected emittance growth as the beam and ion motion adiabatically defocuses and decreases, respectively. Simulation results from QuickPIC with Azimuthal Decomposition show that within a single acceleration stage with a 25 GeV energy gain, this concept can limit the projected emittance growth to only ∼2% for a 25 GeV, 100 nm emittance witness beam and ∼20% for a 100 GeV, 100 nm normalized emittance witness beam. The trade-off between the adiabaticity of the plasma density ramp and the initial ion motion at the entrance for a given length of the plasma density ramp is also discussed.

Physics↗

Micromachined ceramic-based chipless LC resonator for high-temperature wireless sensing applications in harsh environments

The primary objective of this work was the fabrication and testing of a wireless LC resonator based on micro-patterned electroceramic materials for the monitoring of high-temperature systems. The twodimensional planar LC resonator sensors were designed and simulated using ANSYS Maxwell software, and these sensors were then fabricated from electrically conductive La 2 NiO 4 /Al 2 O 3 particulate inks. Initially, the phases of La 2 NiO 4 /Al 2 O 3 composite were evaluated by XRD. The patterning and deposition of the ink were completed using a novel micro-casting process onto Al 2 O 3 ceramic substrates, and the final pattern was bonded onto the substrate at 1200 °C for 2 h. The features and the reliability were analyzed by SEM microscopy. The frequency shift with respect to temperature was measured, which is directly related to changes in the sensor’s dielectric permittivity and pattern dimensions. The sensors were characterized at 500 °C–1000 °C in an ambient atmosphere with an RF signal ranging from 10–80 MHz at 175 kHz·s –1 sweep rate. The sensors showed a sensitivity of ~350 kHz °C –1 from 500 °C–1000 °C. Here, a new robust and adaptive signal processing approach was introduced to increase the degree of freedom for analyzing wireless sensors.

42 ENGINEERING↗

LC-IMS-MS Feature Finder

The LC-IMS-MS Feature Finder finds LC-IMS-MS features and conformers using deisotoped features from DeconTools.

Gibbons, Bryson↗

LC-IMS-MS Feature Finder

LC-IMS-MS Feature Finder is a command line software application which searches for possible molecular ion signatures in multidimensional liquid chromatography, ion mobility spectrometry, and mass spectrometry data by clustering deisotoped peaks with similar monoisotopic mass values, charge states, elution times, and drift times. The software application includes an algorithm for detecting multiple conformations and co-eluting species in the ion mobility dimension. LC-IMS-MS Feature Finder is designed to create an output file with detected features that includes associated information about the detected features.

Crowell, KevinL.↗

Summary Statistics for LC_TA03_130719: Micro-CT Data Acquired at LLNL, Specimen 3 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, lithium carbonate (LC). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, LC_TA03_130719, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images 2 . The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for LC_HT02_130812: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, lithium carbonate (LC). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, LC_HT02_130812, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for LC_HT01_130808: Micro-CT Data Acquired at LLNL, Specimen 1 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, lithium carbonate (LC). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, LC_HT01_130808, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

VERSE-LC TCCR Model Calibration using Batch 1A, Batch 2, and Batch 3 Column Data

The objective of this work is to utilize on-line gamma monitoring data collected during Tank Closure Cesium Removal (TCCR) Column Batch 3 operations to calibrate the parameters (essentially, the correction/dilution factors (CF or DF)) used in the VERSE-LC models for the prediction of cesium breakthrough while processing Savannah River Site (SRS) Tank 10H dissolved saltcake High-Level Waste through a packed cylindrical bed of Crystalline Silicotitanate (CST). Calibrated VERSE-LC models could be applied to aid in evaluating future TCCR operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measuring FLOPS Using Hardware Performance Counter Technologies on LC systems

FLOPS (FLoating-point Operations Per Second) is a commonly used performance metric for scientific programs that rely heavily on floating-point (FP) calculations. The metric is based on the number of FP operations rather than instructions, thereby facilitating a fair comparison between different machines. A well-known use of this metric is the LINPACK benchmark that is used to generate the Top500 list. It measures how fast a computer solves a dense N by N system of linear equations Ax=b, which requires a known number of FP operations, and reports the result in millions of FP operations per second (MFLOPS). While running a benchmark with known FP workloads can provide insightful information about the efficiency of a machine's FP pipelines in relation to other machines, measuring FLOPS of an arbitrary scientific application in a platform-independent manner is nontrivial. The goal of this paper is twofold. First, we explore the FP microarchitectures of key processors that are underpinning the LC machines. Second, we present the hardware performance monitoring counter-based measurement techniques that a user can use to get the native FLOPS of his or her program, which are practical solutions readily available on LC platforms. By nature, however, these native FLOPS metrics are not directly comparable across different machines mainly because FP operations are not consistent across microarchitectures. Thus, the first goal of this paper represents the base reference by which a user can interpret the measured FLOPS more judiciously.

99 GENERAL AND MISCELLANEOUS↗

Identification of process related trace level impurities in the actinide decorporation agent 3,4,3-LI(1,2-HOPO): Nozzle–skimmer fragmentation via ESI LC–QTOFMS

We report that 3,4,3-LI(1,2-HOPO) is a chelating ligand and decorporation agent that can remove radioactive lanthanides and actinides from the body. Identification of trace impurities in drug samples is gaining much interest due to their significant influence on drug activity. In this study, trace impurities were detected in manufactured lots of 3,4,3-LI(1,2-HOPO) by a developed method of Liquid Chromatography coupled with photo-diode array UV detection and Electrospray Ionization-Quadrupole Time of Flight Mass spectrometry (LC-QTOFMS), via induced-in-source or collision-induced mass fragmentation (Nozzle-Skimmer Fragmentation). Molecular ions were fragmented within the nozzle-skimmer region of electrospray ionization (ESI) mass spectrometer equipped with a Time of Flight detector. Eight major (detected at levels higher than a 0.1% threshold) and seven minor trace impurities were identified. The respective structures of these impurities were elucidated via analysis of the generated fragment ions using mass fragmentation and elemental composition software. Proposed structures of impurities were further confirmed via isotopic modeling.

3,4,3-LI(1,2-HOPO) ligand↗

Quantitative Proteomics using Nano-LC with High Accuracy Mass Spectrometry

Despite significant advances in LC-MS based technologies, challenges remain in implementing a proteomics platform for routine clinical applications. These include the needed robustness as well as the sensitivity and dynamic range of detection to both effectively address extremely small tissue samples, for example microdissected or biopsy tissues, or high dynamic range samples, such as blood plasma. Other key components include providing the needed throughput to enable statistically meaningful number of analyses for clinical setting within a robust platform that utilizes effective quantitative approaches for high accuracy and reproducibility. This chapter describes the key components of a nanoLC- MS based technological approach that is designed to target these challenges by virtue of enhancing sensitivity, dynamic range coverage, and throughput, for the generation of robust quantitative measurements in support of clinical studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular remodeling in Populus PdKOR RNAi roots profiled using LC-MS/MS proteomics

Plant endo-β-1,4-glucanases belonging to the Glycoside Hydrolase Family 9 have functional roles in cell wall biosynthesis and remodeling via endohydrolysis of (1→4)-β-D-glucosidic linkages. Modification of cell wall chemistry via RNAi-mediated downregulation of Populus deltoides KOR1 (PdKOR), a endo-β-1,4-glucanase gene, in Populus deltoides has been shown to have functional consequences for the composition of secondary metabolome and the ability of modified roots to interact with beneficial microbes. The molecular remodeling that underlies the observed differences at metabolic, physiological, and morphological levels in roots is not well understood. Here we used a LC-MS/MS-based proteome profiling approach to survey the molecular remodeling in root tissues of PdKOR and control plants. A total of 14316 peptides were identified and these mapped to 7139 P. deltoides proteins. Based on 90% sequence identity, the measured protein accessions represent 1187 functional protein groups. Analysis of GO categories and specific individual proteins showed differential expression of proteins relevant to plant-microbe interactions, cell wall chemistry, and metabolism. The new proteome dataset serves as a useful resource for deriving new hypotheses and empirical testing pertaining to functional roles of proteins and pathways in differential priming of plant roots to interactions with microbes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Profiling of bioactive lipids in different dendritic cell subsets using an improved multiplex quantitative LC-MS/MS method

Highlights: • We improved a LC-MS/MS method to measure many mediators simultaneously. • Conventional DCs produce inflammatory lipids (leukotrienes) preferentially. • RA-DCs produce PGI{sub 2}, PGE{sub 2}, and TXA{sub 2} preferentially. Lipids are an energy source and key components of the cell membrane; however, they are also bioactive mediators of physiological and pathophysiological phenomena. Quantification of bioactive lipids is not easy because they have diverse chemical properties and are present in trace amounts. Here, we improved a multiplex method of quantifying bioactive lipids, thereby enabling measurement of 90 compounds simultaneously. We then used this system to quantify bioactive lipids produced by two subsets of dendritic cells (DCs): all-trans retinoic acid-treated DCs (RA-DCs) (a type of tolerogenic DC (tDC)) and conventional DCs (cDCs). We found that cDCs produced inflammatory lipid mediators such as leukotrienes, whereas RA-DCs produced anti-inflammatory lipid mediators such as prostaglandin I{sub 2}. Consistent with this, cDCs expressed larger amounts of mRNA encoding 5-lipoxygenase and LTA{sub 4} hydrolase (both responsible for leukotriene biosynthesis) and RA-DCs produced larger amounts of mRNA encoding prostaglandin I{sub 2} synthase. Taken together, the results suggest that the method is useful for clarifying the roles of bioactive lipids during immune responses.

60 APPLIED LIFE SCIENCES↗

A Top-Down LC-FTICR MS-Based Strategy for Characterizing Oxidized Calmodulin in Activated Macrophages

Liquid chromatography-mass spectrometry (LC-MS) based approach for monitoring time dependent changes in the degree of nitration and oxidation of intact calmodulin (CaM) has been used to resolve approximately 500 CaM oxiforms. Tentative identifications of posttranslational modifications (PTMs) such as oxidation or nitration have been assigned by combining tryptic peptide information (generated from bottom-up analyses) with online collision induced dissociation (CID) tandem mass spectrometry (MS/MS) at the intact protein level. The reduction in abundance and diversity of oxidatively modified CaM (i.e. nitrated tyrosines and oxidized methionines) induced by macrophage activation has been explored and semi-quantified for different oxidation degrees of CaM (i.e. no oxidation, moderate and high oxidation). This work demonstrates the power of top-down approach to identify hundreds of combinations of posttranslational modifications (PTMs) for single protein target such as CaM.

59 BASIC BIOLOGICAL SCIENCES↗

Improved lipid analysis using a 2D-LC-MS system with a novel injection procedure

The aim of this study was to improve analysis of nonpolar lipidomics sample extracts using reversed phase (RP) chromatography. A 4/3/3 (v/v/v) mixture of methanol/methyl tert-butyl ether/chloroform (MeOH/MTBE/CHCl 3 , MMC) was chosen for sample extraction solvent based on its proven extraction capability for several lipid classes. To avoid carry over, loss of analytes and peak distortion the loops and all capillaries of the presented LC system were flushed and filled up with methanol until the analytical column. Here, the choice of methanol was due to its weak elution strength and being infinitely miscible with MMC and several other nonpolar solvents. This allowed injection of a 100 μl sample that was 20 μl nonpolar extraction solvent diluted fivefold with methanol. All lipids of 25 lipid classes were transferred quantitatively to the column head where the online dilution of methanol was carried out with aqueous eluent for focusing the lipid analytes. The weak elution strength of methanol prevented peak distortions. The consecutive reversed phase elution resulted in remarkably narrow peaks (full width at half maximum was 0.07–0.08 min typically) and enhanced sensitivity (limit of detection usually in sub nM region) because of increased sample injection volume and narrow peaks. Calibration and quality control samples made by diluting commercial lipid standards 200–50000 times confirmed the applicability of this approach both for targeted lipid quantification and for untargeted quantitative comparison of lipids from different sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Trapping-Micro-LC-FAIMS/dCV-MS Strategy for Ultrasensitive and Robust Targeted Quantification of Protein Drugs and Biomarkers

The sensitivity of LC-MS in quantifying target proteins in plasma/tissues is significantly hindered by co-eluted matrix interferences. While antibody-based immuno-enrichment effectively reduces interferences, developing and optimizing antibodies are often time-consuming and costly. Here, in this study, by leveraging the orthogonal separation capability of Field Asymmetric Ion Mobility Spectrometry (FAIMS), we developed a FAIMS/differential-compensation-voltage (FAIMS/dCV) method for antibody-free, robust, and ultra-sensitive quantification of target proteins directly from plasma/tissue digests. By comparing the intensity-CV profiles of the target vs. co-eluted endogenous interferences, the FAIMS/dCV approach identifies the optimal CV for quantification of each target protein, thus maximizing the signal-to-noise ratio (S/N). Compared to quantification without FAIMS, this technique dramatically reduces endogenous interferences, showing a median improvement of the S/N by 14.8-fold for the quantification of 17 representative protein drugs and biomarkers in plasma or tissues and a 5.2-fold median increase in S/N over conventional FAIMS approach, which uses the peak CV of each target. We also discovered that the established CV parameters remain consistent over months and are matrix-independent, affirming the robustness of the developed FAIMS/dCV method and the transferability of the method across matrices. The developed method was successfully demonstrated in three applications: the quantification of monoclonal antibodies with sub-ng/mL LOQ in plasma, an investigation of the time courses of evolocumab and its target PCSK9 in a preclinical setting, and a clinical investigation of low abundance obesity-related biomarkers. This innovative and easy-to-use method has extensive potential in clinical and pharmaceutical research, particularly where sensitive and high-throughput quantification of protein drugs and biomarkers is required.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enabling Efficient and Confident Annotation of LC-MS Metabolomics Data through MS1 Spectrum and Time Prediction

Liquid chromatography coupled to electrospray ionization-mass spectrometry (LC–ESI-MS) is a versatile and robust platform for metabolomic analysis. However, while ESI is a soft ionization technique, in-source phenomena including multimerization, nonproton cation adduction, and in-source fragmentation complicate interpretation of MS data. Here, we report chromatographic and mass spectrometric behavior of 904 authentic standards collected under conditions identical to a typical nontargeted profiling experiment. The data illustrate that the often high level of complexity in MS spectra is likely to result in misinterpretation during the annotation phase of the experiment and a large overestimation of the number of compounds detected. However, our analysis of this MS spectral library data indicates that in-source phenomena are not random but depend at least in part on chemical structure. These nonrandom patterns enabled predictions to be made as to which in-source signals are likely to be observed for a given compound. Using the authentic standard spectra as a training set, we modeled the in-source phenomena for all compounds in the Human Metabolome Database to generate a theoretical in-source spectrum and retention time library. A novel spectral similarity matching platform was developed to facilitate efficient spectral searching for nontargeted profiling applications. Taken together, this collection of experimental spectral data, predictive modeling, and informatic tools enables more efficient, reliable, and transparent metabolite annotation.

60 APPLIED LIFE SCIENCES↗

Discovery of novel glucose-regulated proteins in isolated human pancreatic islets using LC-MS/MS-based proteomics

The prevalence of diabetes mellitus is increasing dramatically throughout the world, and the disease has become a major public health issue. The most common form of the disease, type 2 diabetes, is due in part to insufficient insulin production from the pancreatic beta-cell. Since glucose is the most potent and physiologically important regulators of beta-cell function under physiological conditions, understanding the insulin secretory defect underlying type 2 diabetes requires a better understanding of glucose regulation of beta-cell function. To this aim, a bottom-up LC-MS/MS-based proteomics approach was used to profile pooled islets from multiple donors under basal (5 mM) or high (15 mM) glucose conditions. Our analysis discovered 256 differentially abundant proteins ({approx}p < 0.05) after 24 h of high glucose exposure from more than 4500 identified in total. Several novel glucose-regulated proteins were elevated under high glucose conditions, including regulators of mRNA splicing (Pleiotropic regulator 1), processing (Retinoblastoma binding protein 6), and function (Nuclear RNA export factor 1), in addition to Neuron navigator 1 and Plasminogen activator inhibitor 1. Proteins whose abundances markedly decreased during incubation at 15 mM glucose included Bax inhibitor 1 and Synaptotagmin-17. Many proteins found to be differentially abundant after high glucose stimulation were uncharacterized or hypothetical. These findings expand our knowledge of glucose regulation of the human islet proteome and suggest many hitherto unknown responses to glucose that require additional studies to explore novel functional roles.

59 BASIC BIOLOGICAL SCIENCES↗