Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Integrating Cybersecurity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Advanced Reactor Control and Operations (ARCO): A University Research Facility for Developing Optimized Digital Control Rooms

The Advanced Reactor Control and Operations (ARCO) facility was constructed in January 2018 to serve as a test bed for advanced reactor control rooms and operator support systems. Since then, it has supported human-machine interface user experience research, fault detection and mitigation technology development, control room concept of operations development, and remote operations research. ARCO serves as the control room for the Compact Integral Effects Test (CIET) facility, which replicates the primary-side flow paths and thermal-hydraulic behavior of a fluoride-salt-cooled high-temperature reactor (FHR) using simulant fluids and scaling principles. New reactor designs feature different operating conditions and scenarios than those in existing reactors. ARCO supports the research and development of digital tools for operator communications, intuitive real-time data analysis, online health monitoring and prognostics, and control room cybersecurity. By integrating these different technologies, ARCO acts as a prototypical control system to iteratively develop methods and tools of operation in advanced small modular nuclear reactors. This paper describes the features of and challenges to operating advanced small modular reactors underlying the design basis for ARCO and its operator support systems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Smart Packaging for Critical Energy Shipment (SPaCES)

Recent technical advances have brought forth revolutionary Smart Packaging (SP) technology. SP incorporates multiple electronics, chemical, and mechanical sensing technologies into packaging materials, and utilizes them to monitor and display package content status. SP can also employ embedded micro actuators to react to undesirable package conditions such as moisture/temperature anomalies or harmful chemical reactions and neutralize it. When further integrated with wireless sensing and secure networking, SP provides wholistic system-wide remote situation awareness capability for real-time crisis management. Finally, we also see that SP can be further integrated with 3D printing technology to offer form-factor customization and application specific solutions suitable for DOE (Department of Energy) NNSA’s (National Nuclear Security Administration) R/N (radiological/nuclear) material shipment and management needs; this has the potential to improve safety, security, and overall operation process quality. This report surveys SP technology as the state of the art (SOTA) and analyzes how it can integrate with cybersecurity and 3D printing to address NNSA’s critical R/N material shipment and storage requirements. This report further presents our FY23/24 investigation plan describing project background, goal, motivation, proposed work, and statement of work and cost.

47 OTHER INSTRUMENTATION↗

Cybersecurity in Photovoltaic Plant Operations

This paper provides practical information for PV plant operators regarding cybersecurity. Plans to integrate photovoltaic generation into utility systems requires that cybersecurity be considered in every aspect- from customer data to business information to plant monitoring and control operations. This paper describes the types of threats encountered in operation of PV plants; challenges faced by photovoltaic plant operators in implementing cybersecurity; cybersecurity standards that apply to photovoltaic plant operations; cybersecurity response plans and recommended best practices to ensure photovoltaic plant cybersecurity.

14 SOLAR ENERGY↗

Cybersecurity Considerations for Hydrogen Infrastructure in Airport Environments

This report explores key cybersecurity concerns and best practices within environments that serve as reference points for the development of hydrogen fueling infrastructure for aviation. This cybersecurity analysis leverages prior NREL studies: 1) hydrogen fueling station component validation to identify vulnerabilities and failure events documented in physical equipment, and 2) electric aircraft charging infrastructure analysis to explore primary cybersecurity vulnerabilities. It reviews the criticality of digitized technologies in sustaining hydrogen fuel production, storage, and fueling systems, noting cybersecurity concerns that are universal to power systems and industrial control systems in general. In considering cybersecurity vulnerabilities within a future landscape of hydrogen energy for aviation applications, a reference architecture was intended to reveal the points of connection between assets and the potential sensors that are vulnerable to manipulation in the event of compromised access or communication within a SCADA system. A generalized reference architecture can help stakeholders, engineers, or strategists understand connections, criticalities, and standard practices when it comes to designing and planning for new systems. There are several gaps to account for in assessing the future of hydrogen production, storage, and fueling for aviation. Engaging stakeholders, including aircraft manufacturers, electric utilities, site property owners, and local communities, will inform decision-making around site structure, operations, and resources for future hydrogen fueling infrastructure to understand operational needs and cybersecurity awareness. Cybersecurity mitigation strategy must consider physical attack vectors that emerge with the integration of hydrogen systems into existing airport security requirements. The cybersecurity risk assessment contained in this report is an entry point into potential future granular-level analyses to be conducted as part of hazard and risk assessments for safe aviation hydrogen infrastructure, determining how the scale of hydrogen fuel infrastructure for aviation impacts the volume of cyber attack vectors, and what, if any, are the vulnerabilities associated with different types of on-board hydrogen systems. In this nascent development phase, assessing how best to integrate cybersecurity practices into an evolving U.S. aviation landscape provides critical insights into building increased awareness and stakeholder engagement to support a cyber-resilient infrastructure.

08 HYDROGEN↗

Cybersecurity Enhancement in Digital Substations: Hidden Markov Model-Based Smart Cyber Switching and Threat Response

The rising incidence of cyber-attacks on critical infrastructure and power grids poses significant threats to the stability and reliability of electrical substations, with potentially devastating consequences such as extended blackouts. This paper introduces an advanced cybersecurity framework aimed at safeguarding IEC 61850-based substations through the integration of software-defined networking (SDN) and digital twin (DT) technologies. The proposed DT-based framework employs smart cyber switching (SCS) for proactive threat mitigation and concurrent intelligent electronic device (CIED) for swift system restoration, thereby maintaining continuous operational integrity and robust cybersecurity defenses. Central to this framework is the adaptive port controller (APC), which enables dynamic port management to adapt to evolving threats, and an intrusion detection system (IDS) designed to detect and neutralize malicious attacks on IEC 61850-based sampled value (SV) and generic object-oriented substation event (GOOSE) messages within the substation’s communication network. Further, novel predictive intrusion detection and response (PIDR) algorithm is implemented on a digital substation (DS) to predict the best route to be taken by the attacker. The efficacy of these comprehensive cybersecurity frameworks is validated through rigorous simulations and a hardware-in-the-loop (HIL) testbed, showcasing the system’s ability to sustain substation operations amidst cyber-attacks.

Digital substation↗

Verifying the Computational Integrity of Power Grid Controls with Zero-Knowledge Proof

The control of future power grids is migrating from a centralized to a distributed/decentralized scheme to enable a massive penetration of distributed energy resources with rising dependence on communication infrastructure. A common assumption made for most existing distributed/decentralized controllers is that local controllers would faithfully follow the designated controller dynamics based on the data received from communication channels. However, with increased probability of cyberattacks on Operational Technology infrastructure, such an assumption could be risky because proper execution of the controller dynamics is then built on trust in secure communication and computation. In this work, we leverage a cryptography technology known as zero-knowledge scalable transparent arguments of knowledge (zk-STARK) to verify the computational integrity of power grid control algorithms, with projected linear dynamics-based control schemes as the initial proof-of-concept test case. The method presented here converts the cybersecurity challenge of data integrity for grid control into a subset of computational integrity.

computational integrity↗

Cybersecurity Baselines for Electric Distribution Systems and DER

The National Association of Regulatory Utility Commissioners (NARUC) has partnered with the Department of Energy (DOE) to develop a set of cybersecurity baselines for electric distribution systems and the distributed energy resources (DERs) that connect to them. Cybersecurity is an integral underpinning of power system resilience, and this initiative builds on work that states have undertaken over the last decade to mitigate cybersecurity risk across their critical infrastructures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

User Guide to the Facility Cybersecurity Framework Internet of Things (IoT) Self-Assessment

The FEMP Facility Cybersecurity Framework (FCF) Internet of Things (IoT) Self-Assessment is a comprehensive tool aimed at illuminating the foggy domains of IoT and Industrial Internet of Things (IIoT) security. The assessment was developed using insights from recognized standards and guidelines to identify, address, and mitigate the challenges posed by the massive surge of interconnected devices. The FCF IoT Self-Assessment was created using the knowledge from established National Institute of Standards and Technology (NIST) publications such as NIST SP 800-53, NIST SP 800-213, and NIST Cybersecurity Framework (CSF). Additionally, integrating NIST SP 800-213A IoT Device Cybersecurity Guidance for the Federal Government ensures federal agencies are equipped with specific IoT security insights. This user guide has been developed to facilitate a thorough understanding of the tool. As users delve into the assessment, the guide offers a clear navigation walkthrough, report generation, and interpretation of the report.

97 MATHEMATICS AND COMPUTING↗

ARCADE Technical Pathway and Industry Impact

The Advanced Reactor Cyber Analysis and Development Environment (ARCADE) simplifies the evaluation and assessment of robustness factor and cyber resilience that support secure-by-design for advanced reactor nuclear power plants. In this manner, ARCADE supports risk-informed performance based (RIPB) evaluations of cybersecurity through its integration of plant physics with high-fidelity emulations of control systems. This cross domain approach enables comprehensive analysis of control system sensitivities, cyber-attack scenarios, and their consequences. ARCADE has been custom developed to meet the demands identified in Tier 1 of the Tiered Cyber Analysis (TCA) as outlined in NRC Draft Regulation Guide (RG) 5.96, which provides a RIPB cybersecurity approach for new reactors.

97 MATHEMATICS AND COMPUTING↗

Secure and Resilient Operations Using Open-Source Distributed Systems Platform (OpenDSP)

The goal of this project is to identify and address cybersecurity gaps by developing a multi-layer multi-channel cyber-physical defense and survival mechanism for operating distribution networks with high penetration of solar / inverter-based resource (IBR) / distributed energy resource (DER). The proposed security enhancements are built upon the distributed framework and solution architecture for both information technology (IT) and operational technology (OT) systems. The technical solutions consist of two composite functionalities and six layers: proactive defense (vulnerability assessment, communication protection, and attack detection, as layers 1-3), and adaptive self-healing (attack-resilient control, adaptive recovery, and resilient survival, as layers 4-6). These layers, built on and extended from DHS CISA Cyber Framework, establish an integrated and robust cybersecurity framework for operating large-scale distribution networks.

14 SOLAR ENERGY↗

Performing Numerical Analysis of Cybersecurity Options Using Dynamic Risk Analysis Tool EMRALD

Cyberattacks can have many different attack paths, durations, and goals. There are also many different mitigation options involving hardware, software, and/or humans. Considering a cyber threat should involve defense-in-depth methods and a quantitative or numerical evaluation of overall effectiveness against dynamic, time-dependent attacks to make cost and risk-informed decisions. Typical cyberattack modeling methods only provide a qualitative evaluation. The main areas of cybersecurity are confidentiality, integrity, and availability. For companies with cyber-physical systems such as advanced nuclear reactors, cyber-related safety is a requirement set by North American Electric Reliability and the U.S. Nuclear Regulatory Commission. They are also concerned about availability or reliability as a business case. As cyber threats are evolving to a business-for-hire structure, more attacks may focus on disrupting business success and reliability, causing financial and economic stability risk. Companies want to know business reliability and recovery from those threats, and that requires modeling physical behavior of the targets. Dynamic-state-based and Markov-based modeling provides a method for better cyber scenario modeling with different tools having issues such as state-base explosion. Dynamic modeling enables time and conditional features not found in other numerical evaluation methods. EMRALD (Event Modeling Risk Assessment using Lined Diagrams) is a dynamic risk analysis modeling and simulation tool and has features that reduce modeling issues. It has been used to model different time-dependent events including plant behavior and operator procedures. As a general modeling tool, EMRALD can also be used to model cyberattack scenarios with varying mitigation options and quantify effectiveness, producing numerical data for risk-informed decisions. This paper uses EMRALD to demonstrate that dynamic numerical risk analysis can be used for cyber threat modeling to provide insights for design decision-making and optimize defense strategies. Keywords: cyber modeling; cyber-physical systems; numerical cyber modeling

97 - MATHEMATICS AND COMPUTING↗

A Prototype Software to Demonstrate a Data Catalog for Hanford Environmental Datasets

Ensuring that data on long-term environmental remediation at the Hanford Site is high-quality, traceable, and easily accessible is an ongoing challenge, complicated by decades of data collection, multiple contractors maintaining data sources, and the wide range of data types. A centralized data catalog, known as the Hanford Environmental Information and Data Index (HEIDI), has been under development as part of the Hanford Environmental Data Management (HEDM) program to address these challenges. HEIDI fulfills a critical need to bring together a wide range of data types and sizes from multiple authoritative data sources, while documenting the data pedigree and quality information (i.e., traceable to the data source/originator). This document describes additional development and maturation of the HEIDI prototype. Key accomplishments included deploying the catalog software, Esri Geoportal Server, on a server accessible to Hanford Local Area Network users, conducting cybersecurity evaluations, investigating integrated authentication solutions, and conducting functional testing of the catalog prototype. The server-based deployment enabled targeted feedback, leading to enhancements including improved accessibility features and an expanded metadata schema. Specifications for the server-based deployment of the prototype catalog and the HEIDI metadata schema are provided in this document to support subsequent HEIDI deployment by the U.S. Department of Energy Richland Operations Office.

54 ENVIRONMENTAL SCIENCES↗

Data Centers and Digital Assurance Workshop 2 – Prioritizing Digital Assurance Challenges, Session 2

The second session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 10, 2025, focused on prioritizing digital assurance challenges at the intersection of data centers and the electric grid. Building on the foundational concepts introduced in Workshop 1, this session deepened the application of the Threat–Vulnerability–Consequence (TVC) framework and emphasized the urgency of addressing cybersecurity, supply chain integrity, and operational reliability. Participants explored the growing convergence of digital and physical systems, the expanding attack surface due to global supply chain dependencies, and the implications of AI-driven load behavior. Real-world incidents—including the Volt Typhoon campaign and vulnerabilities in Solarman and Deye platforms—were analyzed to illustrate the risks of unpatched systems, insecure APIs, and inadequate vendor oversight. Key themes included architecture and interface weaknesses, governance gaps, and human and procedural shortcomings. The workshop also examined the evolving regulatory landscape, highlighting new federal mandates around Foreign Entity of Concern (FEOC) compliance and large-load reliability standards. Through interactive exercises, stakeholders ranked and mapped digital assurance risks from their respective perspectives—utilities, operators, and vendors—laying the groundwork for mitigation strategies and shared accountability models to be developed in Workshop 3. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

PSA 2025 DPRA for Cyber Optimization

Cyberattacks can have many different attack paths, durations, and goals. There are also many different mitigation options involving hardware, software, and/or humans. Evaluating defense options should include quantitative evaluation of overall effectiveness to make cost and risk-informed decisions. Typical cyberattack modeling methods only provide a qualitative evaluation and have difficulty with time dependent scenarios. The main areas of cybersecurity are confidentiality, integrity, and availability. For companies with cyber-physical systems such as advanced nuclear reactors, cyber-related integrity is a requirement set by the U.S. Nuclear Regulatory Commission. But companies are also concerned about availability or reliability as a business case. As cyber threats are evolving to a business-for-hire structure, more attacks focus on disrupting business success and reliability, causing financial and economic stability risk. Companies want reliability analysis while optimizing cost, which requires more than safety modeling methods. Dynamic-state-based and Markov-based modeling provides a method for better cyber scenario modeling with timing and conditional features not found in other numerical evaluation methods. EMRALD (Event Modeling Risk Assessment using Lined Diagrams) is a dynamic risk analysis modeling and simulation tool and has features that reduce modeling issues such as state-base explosion found in Markov-based tools. It has been used to model different time-dependent events including plant behavior and operator procedures. As a general modeling tool, EMRALD can also be used to model cyberattack scenarios with varying mitigation options and quantify effectiveness, producing numerical data for risk-informed decisions. This paper uses EMRALD to demonstrate that dynamic risk analysis can be used for cyber threat modeling to provide insights for design decision-making and optimize defense strategies.

97 - MATHEMATICS AND COMPUTING↗

Integrated behavior-based infrastructure command validation

A cybersecurity infrastructure command validation system is provided herein for validating asset commands issued within an infrastructure network. The cybersecurity infrastructure command validation system can be integrated into an infrastructure network to monitor and validate infrastructure asset commands in real-time or while the infrastructure network is active. The cybersecurity infrastructure command validation system can receive or intercept commands issued by asset controllers. The cybersecurity infrastructure command validation system can validate the commands based on a command validation model. The command validation model can represent normal operating behavior of the infrastructure network. The cybersecurity infrastructure command validation system can provide valid commands to the intended infrastructure asset, or can reject invalid commands. The cybersecurity infrastructure command validation system can store validation results for use in updating the command validation model. The cybersecurity infrastructure command validation system can flag or otherwise warn the infrastructure network or administrators of invalid commands.

Akyol, Bora A.↗

Building Nuclear-Specific Cybersecurity Expertise in Higher Education

The rapid digitalization of nuclear power plants (NPPs) and the deployment of advanced and small modular reactors (A/SMRs) have expanded the cybersecurity attack surface within the nuclear sector. This evolution introduces unique challenges beyond those faced in general information technology (IT), operational technology (OT) and industrial control system (ICS) security, due to nuclear power’s regulatory rigor, safety-critical nature, and operational needs. A pressing workforce gap persists; cybersecurity graduates typically lack nuclear-specific context and retraining them for industry readiness requires 12–18 months, creating a significant burden. This paper addresses this gap by defining the domains of knowledge that nuclear cybersecurity specialists must master, spanning cybersecurity, nuclear engineering, OT/ICS security, and regulatory governance. We propose a curricular framework integrating technical, regulatory, and applied learning components to accelerate workforce readiness. Our approach builds on existing findings that current curricula inadequately integrate nuclear engineering and cybersecurity, shifting the discourse from why specialization is needed to what knowledge must be taught. The recommendations have implications for workforce development and long-term resilience of the nuclear energy sector.

99 - GENERAL AND MISCELLANEOUS↗

Progress on the MARVEL Cybersecurity by Design Model-Based Systems Engineering Project

Formal model-based systems engineering (MBSE) combines a model, systems thinking, and systems engineering to visually depict the boundaries, context, and behavior of interconnected systems, facilitating effective design, development, and utilization of engineered systems throughout the systems engineering lifecycle. Although nuclear reactor vendors employ these tools to integrate functionality, performance, and safety, they are not yet addressing digital risk concerns introduced by use of operational technology, such as digital instrumentation and control systems. To accomplish this objective, the Microreactor Applications Research Validation and EvaLuation (MARVEL) microreactor was used as an MBSE case study. This real-world application provides a first-of-a-kind opportunity to demonstrate the benefits of integrating digital risk and cybersecurity into the MBSE design process of a nuclear reactor. This paper provides an update of the ongoing MARVEL Cyber MBSE project as it specifically relates to the integration of digital risk management and cybersecurity by design.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Cybersecurity Platform and Certification Framework Development for Extreme Fast Charging (XFC)-Integrated Charging Ecosystem (Final Project Report)

This report summarizes a pioneering effort in Electric Vehicle charging infrastructure ecosystem cybersecurity requirements, assessment methodologies, functional verification, as well as embodiment of the key technologies in the form of hardware and software tools being made available to the public. EPRI led a team of experts, as well as a stakeholder coalition encompassing all key actors in the EV charging infrastructure ecosystem that includes eXtreme Fast Charging (XFC) equipment (defined as 200kW or above). EV charging infrastructure in the United States is a patchwork of networks that have continued to grow organically and have been designed to serve the charging needs of the EV owners, who are their customers. In doing so, each network provider, as well as their connected entities such as the cloud Electric Vehicle Service Providers or EVSPs, utility back office, utility AMI networks, payment networks, as well as Original Equipment Manufacturer (EV manufacturer) telematics networks, have designed systems that may work well individually, but no single entity is responsible for the entire ecosystem to be secure in terms of data exchange. Furthermore, there is no uniformity in how each actor has implemented the cybersecurity requirements since no system-wide cybersecurity requirements existed prior to this project. The final project report describes the technical approach guided by the EV charging infrastructure cybersecurity working group, convened specifically for this project. The technical approach included definition of requirements at the ecosystem level, treated as a ‘system of systems’, and then passed down to individual systems (EVSE, EV, cloud EVSP, utility, and the payment networks), followed by developing the cybersecurity risk and vulnerability assessment methods, that were later applied to real-world cyber-physical systems at EPRI, ANL, and NREL laboratories, to validate both the process and the results. Finally, in a spotlight over the most vulnerable equipment, which is the EV charge station (AC or DC), the team developed a multi-layer cybersecurity implementation in the embedded domain embodied by the open-source Secure Network Interface Card (SNIC) demonstrating the various ways in which the infrastructure can be secured protecting against the identified attack surfaces. Finally, the entire process of EV infrastructure cybersecurity assessment was encapsulated in the Electric Vehicle Charging Cybersecurity Management (EVC2M) online GUI-based tool, that is expected to be released to the public. The report presents the objectives, the technical approach, the key results, and recommendations for future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗