Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission

We describe a modular apparatus for use in parity-violation measurements in epithermal neutron–nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparatus is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron–nucleus resonances in the 0.1–10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a 3 He- 4 He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency 6 Li- 7 Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of 3 He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in 139 La which employs two identical 139 La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement in the spatial resolution for imaging with fast neutrons

In this paper, we report on the realization of an improved concept for the detection of fast neutrons using a specific setup of scintillators with the aim to overcome limitations in spatial resolution. While fast neutron imaging (FNI) is a technique to investigate very thick material layers in transmission mode, currently there is a limit in the spatial resolution at ~1 mm, which hinders the performance for the detection of features like cracks, material damage or pores in large objects ($\gg$1 cm 3 ). The improved concept presented here is based on the separation of the converter material from the scintillation layer in a suitable way, which was successfully tested and referenced to the standard devices at the NECTAR facility (FRM-2, MLZ, Garching) under realistic beamline conditions. The results imply a break-through in enabling detection of structures on the order of 0.2 to 0.5 mm (a more precise estimation is not possible due to other resolution determing factors in a realistic setup). Potential additional improvements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computing inelastic neutron scattering spectra from molecular dynamics trajectories

Abstract Inelastic neutron scattering (INS) provides a weighted density of phonon modes. Currently, INS spectra can only be interpreted for perfectly crystalline materials because of high computational cost for electronic simulations. INS has the potential to provide detailed morphological information if sufficiently large volumes and appropriate structural variety are simulated. Here, we propose a method that allows direct comparison between INS data with molecular dynamics simulations, a simulation method that is frequently used to simulate semicrystalline/amorphous materials. We illustrate the technique by analyzing spectra of a well-studied conjugated polymer, poly(3-hexylthiophene-2,5-diyl) (P3HT) and conclude that our technique provides improved volume and structural variety, but that the classical force field requires improvement before the morphology can be accurately interpreted.

36 MATERIALS SCIENCE↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Double Aperture HTS Dipole Magnet Model for the Persistent Current Operation

Particle accelerators use many different types of magnets. There is an interest in replacing rather low-field conventional resistive magnets with high-temperature superconducting (HTS) magnets. The main goal is to reduce operational expenses, which is critical during the continuously increasing cost of electricity. At Fermilab, several HTS accelerator magnets were built and successfully tested. The paper described a variant of the double-aperture dipole magnet that could be suitable for future Lepton Colliders. A single short-circuited HTS coil of 3.8 kA generates a homogeneous magnetic field of 57 mT in both magnet gaps of 84 mm. The short model magnet was designed, built, and successfully tested at liquid nitrogen temperature. This magnet works in a persistent current mode, which provides additional cost savings when used in particle storage rings operated at a stable magnetic field. The results of design, fabrication, and tests are presented and discussed. The magnet demonstrated a high magnetic field stability in both apertures, efficiency of correction coils, and primary powering circuit.

Kashikhin, Vladimir [Fermilab] (ORCID:000000017249↗

Cryogenic-Refined MOSFET Modeling for Oscillator, Frequency Divider, and Amplifier Designs Below 4 K

Capturing device characteristic changes at cryogenic temperatures is crucial for cryo-CMOS circuit designs. In this work, we present an isothermal cryogenic-refined modeling approach for CMOS transistors that is simple, low overhead, and easy to implement while offering the required accuracy for predicting circuit performance at the designated temperatures. Guided by die-level measurement data and circuit design principles, the model introduces corrections to only five critical parameters: threshold voltage, carrier mobility, elevated low-frequency flicker noise, dominant high-frequency shot noise, and subthreshold swing (SS). These refinements are implemented around the foundry-provided SPICE model, which is typically validated only down to about 200 K. With these adjustments, the proposed cryogenic-refined model achieves less than 5% error in both large-signal metrics (I–V characteristics) and small-signal parameters (e.g., transconductance) when compared with device measurements at deep-cryogenic temperatures. The methodology is validated in two advanced technologies: TSMC 40-nm CMOS and GlobalFoundries (GF) 45-nm RF-SOI. We further demonstrate its applicability in three representative RF circuits: a 30-GHz LC oscillator, a high-speed current-mode-logic (CML) frequency divider (FD), and a subthreshold Gb/s amplifier, all showing close agreement between simulated predictions and measurements performed at 4 and 2.5 K. Finally, we believe that the proposed approach is implementation-friendly and can significantly accelerate the development of cryo-CMOS integrated circuits.

circuit modeling↗

Polarized target nuclear magnetic resonance measurements with deep neural networks

Continuous-wave Nuclear Magnetic Resonance (CW-NMR) operated in constant-current mode has served as a foundational technique for polarization measurement in solid-state dynamically polarized targets within nuclear and high-energy physics experiments for several decades, and it remains an essential tool. Conventional Q-meter-based phase-sensitive detection is critical for precise real-time determination of target polarization during scattering runs. However, the accuracy and reliability of these measurements are frequently compromised by elevated noise levels, baseline drift, and systematic uncertainties arising from signal isolation and fitting, ultimately degrading the overall experimental figure of merit. In this work, we report the first successful application of neural network architectures to continuous-wave NMR polarization metrology. By leveraging advanced machine learning techniques for signal extraction and denoising, we achieve a substantial reduction of fitting uncertainties under a variety of realistic simulated and experimental conditions. These improvements translate directly into more robust real-time (online) polarization monitoring and higher precision in subsequent offline analysis. By reducing analysis-induced uncertainty, the resulting methodology can improve the effective figure of merit for scattering experiments employing dynamically polarized targets and provides a new toolset for NMR-based polarimetry in high-energy and nuclear physics.

Metrology↗

Northstar Mo100 Target Beam Spot Size Sensitivity Study

Northstar Mo100 target for production of the medical isotope Mo99 is particularly sensitive to beam over focusing because of the intended high power density. At 38 MeV and 6.32 mA (240 kW beam power, nominally 160 kW th in the target), small deviation from the nominal 12 mm FWHM beam can significantly increase the target disk temperatures and more importantly the load bearing target window temperature. A rhodotron will be the source of the electron beam to be used in the isotope production. This machine operates in a pulsed beam mode, currently expected to be at 50 Hz, which results in a 100 C temperature oscillation above and below the steady state temperature that is the focus of this study. This must be considered in the determination of minimum beam spot size that can be accepted by the target without risk of failure. In addition to the nominal beam spot size of 12 mm, the analysis of 10, 11 and 14.5 mm beam spot sizes are analyzed. The primary conclusion is that an over focused beam to just 11 mm FWHM is the minimum beam spot allowable, based on window temperature and the Ultimate Tensile Stress (UTS) of the window material Inconel 718 as a function of temperature. In contrast an under focused beam of 14.5 mm FWHM has much reduced target and window temperatures, but there is a resulting 6% drop in isotope production, all other factor staying the same. These results are presented herein.

07 ISOTOPE AND RADIATION SOURCES↗

Universal Battery Supercharger

During the course of the UBS project a dc-fast charger was developed to be used in off board high power charging stations. High efficiency is targeted to reduce the charging price for the consumer while reducing the charge time. In the meantime, the size of the converter is minimized so that it could be used in small spaces and potentially urban areas. The topology is modular, and the power level can be expanded for charging higher power vehicles like trucks and buses. During the course of this research several key technologies was developed in LESES that improve the performance of the power electronics system used in EV charger. Integrated magnetics was developed for DMCR to improve the power density as well as efficiency of the magnetic components which is one of the main bottlenecks of EV development. Triangular mode EV current conduction mode is using to perform soft switching (increase efficiency) without adding any new components to the existing topology. Passive and active damping are developed to suppress the interaction between grid and converter, stabilizing the control system. Further numerous other technical problems have been solved to pave the way for even higher performance converters in the future.

25 ENERGY STORAGE↗

Gain Stability of Hamamatsu R5912-MOD Photo-Multipliers at Low Temperature

The Photon Detection System is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 Photo Multiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operated at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu 5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70°C, although far from the liquid Argon one. No gain recovery was obtained bringing the PMT back to room temperature. We suspect that dynode deterioration due to temperature gradient plays a significant role in this phenomenon. During our test, the PMT was illuminated by a 520 nm laser source and operated in current mode. The laser beam was split into two optical fibers, the first one transmitting light through Neutral Density filters and then diffusing it over the surface of the PMT photocathode. The other optical fiber was used for an independent reference measurement of the injected light via a bolometric photodetector. In this presentation, the main technical characteristics of the measurement system are shown together with preliminary results which need further investigation to elucidate the underlying mechanisms driving the gain loss and to propose new mitigation strategies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved Joint FHC+RHC Sterile Analysis with Nu-on-E Sample

The NOvA experiment measures neutrino oscillations in a nearly pure muon neutrino beam. The neutral current (NC) and the muon neutrino charged current (CC) interaction disappearance are studied to search for active-to-sterile neutrino oscillations. NOvA consists of two functionally identical detectors placed 14 mrad off-axis of Fermilab's NuMI beamline. The Near Detector (ND) is located 100 m underground on-site at Fermilab, while the Far Detector (FD) sits on the surface 810 km away at Ash River, Minnesota. The NuMI beam is capable of running in forward or reverse horn current modes, creating a predominantly neutrino or antineutrino beam, respectively. For this analysis, a simultaneous near and far detector joint fit approach was utilized. Systematic uncertainties constrain the ND while the statistical uncertainties constrain the FD. For the upcoming analysis, we plan on including a dedicated neutrino-on-electron elastic scattering sample. This interaction is advantageous as it is subject to minimal cross-section uncertainties, which will help reduce degeneracies between other uncertainty categories. This thesis presents the sterile neutrino oscillation sensitivity results using 27.2e+20 POT in FHC mode, 12.6e+20 in RHC mode.

Haejun, Stella Oh [Cincinnati U.]↗

First Measurement of the Flux-Averaged Differential Charged-Current Electron-Neutrino and Antineutrino Cross Section on Argon with the MicroBooNE Detector

The MicroBooNE experiment uses a liquid argon time projection chamber (LArTPC) located at Fermilab, Chicago. MicroBooNE is able to detect neutrinos from two accelerators: on-axis from the Booster Neutrino Beam (BNB) and off-axis from the Neutrinos at the Main Injector (NuMI). While one of the primary objectives of the MicroBooNE experiment is to search for short-baseline neutrino oscillations using the BNB, it also has a rich program of R\&D, neutrino-argon cross section measurements and beyond the standard model searches. This thesis presents a detailed study of the off-axis neutrino flux from the NuMI beam at MicroBooNE as well as measurements of the charged current flux-averaged total and differential electron neutrino and antineutrino cross section on argon using this beam. The data used in these measurements was taken during the first year of MicroBooNE running while the NuMI beam was in forward horn current mode. These are the first high statistics measurement s of ele ctron neutrino argon interactions and include the first measurement of this cross section as a function of the outgoing electron energy and with full angular coverage. The measurement is compared to the GENIE and NuWro generators and shows consistency with both.

Mistry, Krishan Jitesh↗

Optimizing Insulation Design for Transformers in Medium Voltage Power Conversion Systems

Medium-frequency transformers (MFTs) play a crucial role in medium-voltage (MV) solidstate transformer (SST) systems, particularly in extreme fast charging applications. Achieving partial discharge (PD)-free operation while maintaining high power density is a significant challenge due to the high electric field (E-field) stresses inherent in MV applications. This dissertation focuses on the insulation design and optimization of MFTs used in both the main power electronics circuits and auxiliary power supplies. The study begins with an overview of insulation testing methodologies, including high potential tests, basic insulation level tests, and PD tests, which are critical for evaluating MFT insulation reliability. Given the importance of PD-free operation for long-term reliability, particular emphasis is placed on understanding PD mechanisms, including void, corona, and surface discharge, and their mitigation strategies. A high voltage isolated auxiliary power supply is then introduced, utilizing a gapped transformer encapsulated in silicone gel. This design achieves PD-free insulation up to 18 kV RMS while maintaining low coupling capacitance to minimize common-mode current. The proposed solution ensures reliable operation in MV environments and offers a scalable approach for auxiliary power in cascaded SST architectures. To improve MFT insulation in main power conversion circuits, a novel structure is developed using polypropylene sheets and potting compounds to create a void-free air gap, effectively mitigating E-field intensity. A prototype transformer with this insulation structure is built and achieves PD-free operation up to 30 kV RMS. This design is experimentally validated in a resonant converter operating at 46 kW, demonstrating its feasibility for MV SST applications. Further optimization is implemented to enhance MFT performance for dual-active-bridge(DAB) converters by integrating a semiconductive shielding layer within the insulation structure. This shielding layer improves the magnetic coupling coefficient while effectively confining the E-field within high insulation materials, thereby reducing eddy current losses. The optimized MFT achieves PD-free operation at 12.6 kV RMS and is successfully tested in a DAB converter operating at 43 kW, which meets the insulation requirements for a 13.2 kV SST system. This dissertation advances MFT insulation design by introducing and experimentally validating novel approaches that improve high voltage insulation while optimizing magnetic coupling and manufacturability. The proposed insulation structures enable PD-free operation while minimizing insulation material usage and simplifying assembly, making them ideal for high power, high voltage applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NOvA Sterile Neutrino Search with Additional Systematic Constraints

The NOvA experiment measures neutrino oscillations in a nearly pure muon neutrino beam. The neutral current (NC) and the muon neutrino charged current (CC) interaction disappearance are studied to search for active-to-sterile neutrino oscillations. NOvA consists of two functionally identical detectors placed 14 mrad off-axis of the Fermi National Accelerator Laboratory's NuMI beamline. The Near Detector (ND) is located 100 meters underground on-site at Fermilab, while the Far Detector (FD) is situated on the surface 810 kilometers away at Ash River, Minnesota. The NuMI beam is capable of operating in either forward or reverse horn current modes, producing predominantly neutrino or antineutrino beams, respectively. For this analysis, a simultaneous near and far detector joint fit approach was utilized. Systematic uncertainties constrain the ND while the statistical uncertainties constrain the FD. In addition to the dual baseline approach, the neutrino-on-electron elastic scattering sample was included. This interaction is advantageous as it is subject to minimal cross-section uncertainties, which will help reduce degeneracies between other uncertainty categories. This thesis presents the sterile neutrino oscillation sensitivity results using 27.2e+20 POT in FHC mode, 12.6e+20 in RHC mode, with the nu-on-e sample of 13.6e+20 POT in FHC.

Oh, Haejun [Cincinnati U.]↗

Suppression of MHD modes with active phase-control of probe-injected currents

Abstract Active phase-control of probe-injected current is shown to both suppress and amplify long-wavelength rotating magnetohydrodynamic instabilities in the HBT-EP tokamak. Four probes are connected in quadrature and energized to drive non-axisymmetric currents through the edge of the tokamak, creating magnetic perturbations comparable to previously-studied saturated kink modes or resonant magnetic perturbations that are generated by an external control coil array. Measurements of the magnetic perturbations from the probe-injected currents determine a set of current-carrying helical filaments used to model active feedback control of resistive wall modes. These experiments suggest current-injection feedback may be an effective alternative to external control coils for control of RWMs and other long-wavelength kink-like modes at the edge of tokamaks.

Physics↗

The magnetic structure of long-wavelength magnetohydrodynamic modes in current-carrying stellarator plasmas

Magnetic field fluctuations are observed in current-carrying stellarator plasmas when the rotational transform is close to a rational value at the edge of the plasma. At low plasma pressure, these fluctuations are associated with perturbed currents parallel to the equilibrium magnetic field lines. A model for these magnetohydrodynamic modes in a low-β, three-dimensional stellarator equilibria has been developed. A set of helical current filaments are constrained to mimic the structure of magnetic field lines on rational surfaces derived from three-dimensional (3D) equilibrium reconstructions. Transformation to straight field line coordinates then allows fitting of the poloidal magnetic sensor data to a single harmonic function, which fixes the modeled toroidal mode structure via the field line flow geometry. The developed procedure accurately captures phase and amplitude variation for m/n = 3/2, 3/1, and 4/1 modes in the 3D equilibria of the compact toroidal hybrid experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation and evaluation of multi-dual mode counter-current chromatography in the CUP Modeler software

Counter-current chromatography (CCC) is a separation technique that utilizes immiscible solvent pairs as stationary and mobile phases, which imparts numerous benefits compared to solid-liquid chromatography including the ability to treat either the more-dense or less-dense solvent layer as the mobile phase. Multi-dual mode (MDM) is a CCC elution mode capable of improving the separation of closely eluting compounds by alternating upper- and lower-layer solvent flows in opposing directions within the same separation. While some effort has been made to model MDM, implementation of these models in experimental design has yet to be widely adopted. Accordingly, we further developed our previously published cell utilized partitioning (CUP) model to include MDM predictions with CCC and packaged the full suite of CUP modeling capabilities into a user-friendly, open-source tool called the CUP Modeler. The mathematical model for MDM CCC was derived and validated with experimental separation of ethyl guaiacol (EG) and ethyl phenol (EP), two compounds that co-elute in our previously demonstrated reductive catalytic fractionation (RCF) lignin monomer isolation method. The developed MDM model provided insights into the effect of multiple operating parameters - including stationary phase retention, flow rate, column efficiency, feed concentration ratio, selectivity factor, and solute distribution ratios - on the separation yields, productivity, and purities. Our model agreed with prevailing understanding of MDM but also revealed new insights including that the ideal distribution ratios for co-eluting solutes to be separated by MDM is between 1.1 and 1.5, with the lower value ideally close to 1.25. Overall, this work provides fundamental insights for MDM process design and enables broader adoption of general liquid-liquid chromatography with a new, open-source user-friendly interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Review on Switching Device Fault, Protection, and Fault-Tolerant Topologies of Current Source Inverter

The fault modes, protection, and fault-tolerant topologies of voltage source inverters have been investigated for decades. However, issues and solutions related to the fault modes of current source inverters are less well understood. This paper summarizes some of the key topics relevant to a fault in current source inverters, including types of fault modes and their ramifications, post-fault protection methods, and fault- tolerant current source inverter topologies that have been presented in the literature.

42 ENGINEERING↗