Engineering PapersSearch

SEARCH · Engineering Papers

Results for “AGC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

xEMU Suit Integrated Audio Communications System: Ambient and EVA Pressure Testing System Performance

Testing across several airlock and EVA thermal and pressure scenarios has demonstrated that the Integrated Audio System of NASA’s Exploration Extravehicular Mobility Unit (xEMU) spacesuits transmits and receives intelligible audio communications without the use of a commcap or similar worn device. The xEMU audio system consists of internal loudspeakers and digital microphones (Integrated Communications System –ICS) combined with an adaptive Acoustic Echo Canceller (AEC), outbound voice operated transmission (VOX), and automatic gain control (AGC). Transducers are mounted in an “exploded commcap” configuration with helmet-attached speakers near the ears and three microphones positioned at the collar. The AGC removes inbound audio signals (e.g.,suit, Mission Control, Lander, C&W tones) from the outbound comms stream, reducing echo and feedback (squeal) in low-noise suit environments. The reduction of worn communication equipment increases crewmember comfort, range of movement, and situational awareness. However, test results also highlight the need for proper fan, duct, pump, and gas flow integration with suit acoustics and audio. Ductwork may serve as waveguides for various component and structure-borne noise. Sharply angled ducts can generate turbulent-flow noise. Gas flow from inlets above the crewmember’s head can generate noise when cascading over the faceplate and collar (or commcap) microphones. Sufficient acoustic noise levels (1) require increased gain to boost inbound audio, and (2) may distort signals resulting in AEC disruption or artifacts. Suit-noise levels decline with reduced pressure (density), but then elevated speech and audio effort/power become necessary. Whether the Integrated Audio System, commcap, or other device is used, suit acoustic noise can mask speech in outbound comms. This reduces intelligibility and requires other AECs/devices to suppress comms noise. Yet, adjusting a few components may yield significant improvement. We discuss xEMU audio functionality, demonstrate how acoustical treatment combined with inbound signal conditioning improved clarity during tests, and discuss future modifications.

xEMU

xEMU Suit Integrated Audio Communications System: Ambient and EVA Pressure Testing System Performance

Testing across several airlock and EVA thermal and pressure scenarios has demonstrated that the Integrated Audio System of NASA’s Exploration Extravehicular Mobility Unit (xEMU) spacesuits transmits and receives intelligible audio communications without the use of a commcap or similar worn device. The xEMU audio system consists of internal loudspeakers and digital microphones (Integrated Communications System –ICS) combined with an adaptive Acoustic Echo Canceller (AEC), outbound voice operated transmission (VOX), and automatic gain control (AGC). Transducers are mounted in an “exploded commcap” configuration with helmet-attached speakers near the ears and three microphones positioned at the collar. The AGC removes inbound audio signals (e.g.,suit, Mission Control, Lander, C&W tones) from the outbound comms stream, reducing echo and feedback (squeal) in low-noise suit environments. The reduction of worn communication equipment increases crewmember comfort, range of movement, and situational awareness. However, test results also highlight the need for proper fan, duct, pump, and gas flow integration with suit acoustics and audio. Ductwork may serve as waveguides for various component and structure-borne noise. Sharply angled ducts can generate turbulent-flow noise. Gas flow from inlets above the crewmember’s head can generate noise when cascading over the faceplate and collar (or commcap) microphones. Sufficient acoustic noise levels (1) require increased gain to boost inbound audio, and (2) may distort signals resulting in AEC disruption or artifacts. Suit-noise levels decline with reduced pressure (density), but then elevated speech and audio effort/power become necessary. Whether the Integrated Audio System, commcap, or other device is used, suit acoustic noise can mask speech in outbound comms. This reduces intelligibility and requires other AECs/devices to suppress comms noise. Yet, adjusting a few components may yield significant improvement. We discuss xEMU audio functionality, demonstrate how acoustical treatment combined with inbound signal conditioning improved clarity during tests, and discuss future modifications.

xEMU

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY

A study of silver acetate under extreme conditions

With the aim of exploring chemical systems that may undergo metallization when irradiated with hard X-rays, we selected silver acetate (AgC 2 H 3 O 2 ) for the subject of this study. X-ray-induced decomposition of silver acetate under ambient and high-pressure conditions was observed in a diamond anvil cell (DAC), leading to the formation of metallic nanograins of silver at ambient pressure and 1.65 GPa. At 4 GPa, no decomposition was observed. The Avrami kinetics equation also provides information about novel structural formation at ambient pressure and 1.65 GPa. By modeling of the XRD data, it was found that the size of the silver nanocrystallites formed at 1.65 GPa pressure steadily increased to ∼5 nm after 600 min of X-ray irradiation as determined by applying the Scherrer equation to the diffraction peak widths. Time-resolved X-ray diffraction (XRD) revealed pressure-dependent kinetics, demonstrating that coupling pressure with irradiation enables controlled photochemical pathways in this model system. Concurrent with previous studies, the application of high pressure (HP) can be considered as a means of controlling X-ray synthetic photochemistry.

36 MATERIALS SCIENCE

Frequency Control and Dynamics (Part 1) [Slides]

This presentation provides an introductory overview of system dynamics and frequency control in electric power systems, with a focus on concepts relevant to small and interconnected grids such as those in Malawi. It explains foundational principles of AC system frequency, the relationship between generation-demand balance and frequency deviations, and the operational limits of generators and end-use equipment. The deck discusses frequency stability within broader system stability classifications and illustrates how inertia and turbine-governor dynamics shape system response to disturbances. It then outlines the tiered approach to frequency control - primary, secondary, and tertiary - detailing the roles, characteristics, timescales, and response mechanisms of each. Special emphasis is placed on hydro and thermal unit behavior, area control error (ACE), automatic generation control (AGC), and the operational implications of interconnecting small systems with larger grids. The material was developed to support Malawi's electricity sector and the establishment of the Southern Africa Battery Energy Storage Center of Excellence (SABESS CoE).

24 POWER TRANSMISSION AND DISTRIBUTION

Frequency Control and Dynamics (Part 2) [Slides]

This presentation provides an introductory overview of system dynamics and frequency control in electric power systems, with a focus on concepts relevant to small and interconnected grids such as those in Malawi. It explains foundational principles of AC system frequency, the relationship between generation-demand balance and frequency deviations, and the operational limits of generators and end-use equipment. The deck discusses frequency stability within broader system stability classifications and illustrates how inertia and turbine-governor dynamics shape system response to disturbances. It then outlines the tiered approach to frequency control - primary, secondary, and tertiary - detailing the roles, characteristics, timescales, and response mechanisms of each. Special emphasis is placed on hydro and thermal unit behavior, area control error (ACE), automatic generation control (AGC), and the operational implications of interconnecting small systems with larger grids. The material was developed to support Malawi's electricity sector and the establishment of the Southern Africa Battery Energy Storage Center of Excellence (SABESS CoE).

24 POWER TRANSMISSION AND DISTRIBUTION

Radiant source tracker independent of nonconstant irradiance

A tracker of a radiant source is disclosed. The tracker is composed of a sectored matrix of detectors whose output voltages correspond to their respective levels of irradiance. The voltages are each sampled during a variable length period and the resulting samples are shaped into triangular samples by an integration process. They are supplied to a demodulator which provides an output corresponding to the difference of the time-voltage product of appropriate combinations of the samples. This output, after filtering, represents the angle of incidence on the detectors with respect to a central axis. The triangular samples are also supplied to a demodulator whose output is an AGC voltage which is a function of the sum of the time-voltage integrals of the triangular samples.

Campbell, F. D.

Impact of scintillation of transionospheric communications

Analyses of AGC analog data from the Small Astronomy Satellite (SAS) at VHF (136 MHz) have shown amplitude fluctuations in the signals received at several equatorial tracking sites operated by NASA. Coincident digital telemetry data, transmitted from SAS at 1 kbps, has also been analyzed. Errors in data are shown to increase markedly for nighttime satellite passes around the periods of the two equinoxes as compared to the errors observed during other periods. This paper establishes the qualitative and quantitative correlations between the ionospheric scintillation phenomenon and the occurrence of errors. Strong time and geographic cause and effect relationships are established by determining the statistical correlation between scintillation indices and bit error rates.

Blank, H. A.

Shuttle bit rate synchronizer

A shuttle bit rate synchronizer brassboard unit was designed, fabricated, and tested, which meets or exceeds the contractual specifications. The bit rate synchronizer operates at signal-to-noise ratios (in a bit rate bandwidth) down to -5 dB while exhibiting less than 0.6 dB bit error rate degradation. The mean acquisition time was measured to be less than 2 seconds. The synchronizer is designed around a digital data transition tracking loop whose phase and data detectors are integrate-and-dump filters matched to the Manchester encoded bits specified. It meets the reliability (no adjustments or tweaking) and versatility (multiple bit rates) of the shuttle S-band communication system through an implementation which is all digital after the initial stage of analog AGC and A/D conversion.

Huey, D. C.

Reduced backscattering cross section (Sigma degree) data from the Skylab S-193 radar altimeter

Backscattering cross section per unit scattering area data, reduced from measurements made by the Skylab S-193 radar altimeter over the ocean surface are presented. Descriptions of the altimeter are given where applicable to the measurement process. Analytical solutions are obtained for the flat surface impulse response for the case of a nonsymmetrical antenna pattern. Formulations are developed for converting altimeter AGC outputs into values for the backscattering cross section. Reduced data are presented for Missions SL-2, 3 and 4 for all modes of the altimeter where sufficient calibration existed. The problem of interpreting land scatter data is also discussed. Finally, a comprehensive error analysis of the measurement is presented and worst case random and bias errors are estimated.

Brown, G. S.

Skylab altimeter observations over terrain

The author has identified the following significant results. Data obtained by Skylab radar altimeter (S193) over the continental U.S.A. for pass 1 of SL-3 were analyzed to relate radar return signal parameters such as range, power, and waveform to ground track terrain features. The altimeter, which was originally designed for ocean observations, performed predictably well over terrain with moderate to low relief. The maximum return from more complex areas corresponded usually to the lower flatter regions within the seven kilometer diameter footprint. Altimeter measured heights correlated with map topography with an rms deviation of + or - 30 m for terrain topography with large height dispersion (passes 1 and 28) and + or - 5 m for slowly varying terrain (passes 16, 17, and 18). Analysis of the waveform and statistical characteristics of the individual signals indicated that larger signal power was usually related to dominantly specular reflections from patches 100 m or larger. Results established the capability of a spacecraft altimeter system to observe characteristic radar signatures for different types of terrain within the bandwidth restrictions of the AGC and range tracker loops.

Shapiro, A.

Console test report for shuttle task 501 shuttle carrier aircraft transceiver console (SED 36115353-301)

Performance tests completed on the Space Shuttle Carrier Aircraft (SCA) transceiver console, verifying its design objectives, were described. These tests included: (1) check of power supply voltages for correct output voltage and energization at the proper point in the turn on sequence, (2) check of cooling system (LRU blower, overload sensors and circuitry, and thermocouple probe), (3) check of control circuits logic, including the provisions for remote control and display, (4) check of the LRU connector for presence of correct voltages and absence of incorrect voltages under both energized and deenergized conditions, and (5) check of the AGC and power output monitor circuits.

Lane, J. H.

A bandwidth-compressive modulation system

The phrase 'bandwidth-compressive modulation' means that the compression is achieved not by removing redundancy from the data (data compression), but rather by modulating the carrier phase and amplitude with blocks of data bits. The modulation described here is quadrature amplitude shift keying (QASK), a logical extension of quadrature phase shift keying, (QPSK, or quadriphase). QASK is a cost-effective form of combined phase-and-amplitude modulation. That is, n-bit QASK, like most phase-amplitude forms of modulation, requires considerably less transmitter power than comparably performing n-PSK, while among the class of all n-bit phase-modulation types, n-bit QASK performs nearly optimally but requires the least circuit complexity. A simple, unique microwave transmitter is described which provides high-rate QASK modulation with 4:1 bandwidth compression. A suppressed carrier multiple-loop QASK receiver provides the necessary phase tracking, automatic gain control (AGC), and symbol timing.

Smith, J. G.

Solid State Television Camera (CID)

The design, development and test are described of a charge injection device (CID) camera using a 244x248 element array. A number of video signal processing functions are included which maximize the output video dynamic range while retaining the inherently good resolution response of the CID. Some of the unique features of the camera are: low light level performance, high S/N ratio, antiblooming, geometric distortion, sequential scanning and AGC.

Steele, D. W.

Solid state television camera (CCD-buried channel)

The development of an all solid state television camera, which uses a buried channel charge coupled device (CCD) as the image sensor, was undertaken. A 380 x 488 element CCD array is utilized to ensure compatibility with 525 line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (a) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (b) techniques for the elimination or suppression of CCD blemish effects, and (c) automatic light control and video gain control (i.e., ALC and AGC) techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a deliverable solid state TV camera which addressed the program requirements for a prototype qualifiable to space environment conditions.

Source record

One-third selection for matrix-addressing ferroelectrics

Automatic-gain-control (AGC) circuit regulates gain of intermediate frequency and radio-frequency signals over wide dynamic range with high linearity and very low phase shift. Potential application include radio and television receivers, signal distribution systems, and test and measurement instruments.

Tannas, L. E., Jr.

A bandwidth compressive modulation system using multi-amplitude minimum shift keying /MAMSK/

A bandwidth compressive modem making use of multi-amplitude minimum shift keying (MAMSK) has been designed and implemented in a laboratory environment at microwave frequencies. This system achieves a substantial bandwidth reduction over binary PSK and operates within 0.5 dB of theoretical performance. A number of easily implemented microwave transmitters have been designed to generate the required set of 16 signals. The receiver has been designed to work at 1 Mbit/s and contains the necessary phase tracking, AGC, and symbol synchronization loops as well as a lock detector, SNR estimator and provisions for differential decoding. This paper describes this entire system and presents the experimental results.

Weber, W. J., III

Decision-directed automatic gain control

Logic circuitry determines whether gain fluctuation are result of signal-strength changes or of atypical strings of like data symbols. Automatic Gain Control (AGC) system provides tight control that is independent of short-term, average, received signal energy and has negligible degrading effect on probability of error for signal.

Weber, W. J., III