Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid analysis and integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

696 records · Page 39

An Integrated Hydroclimatic Assessment of Future Reservoir and Hydropower Operations in the U.S.

The engineering of rivers by dams is a formative feature of human-nature systems and the interconnectivity of water, energy, and the climate. Sufficient and broad-based representations of dams in large-scale hydrological models prove essential to mapping their extensive regulation of river flow and biogeochemistry and gauging climate-linked provisions, including freshwater supply and hydropower. We present an integrated modeling framework to investigate future streamflow and hydropower generation in the Contiguous U.S. (1990–2075), leveraging an ensemble of six downscaled and bias-corrected General Circulation Models (GCMs) from the high-end SSP585 scenario of the CMIP6. To achieve this, we develop a reservoir operations and parameterization scheme for 1,384 dams in a high-resolution river network, including simulated hydropower generation for 326 dams. For the GCM ensemble mean, we simulate a widespread increase in regulated streamflow into the late-century (11% annual and 17% in winter for the dam median) with region-specific changes in summer streamflow that feature prominent declines in the Northwest (−7%). Mediation by reservoirs is shown to dampen intra-annual streamflow changes, delivering additional summer releases that partially mitigate declining flows. Total hydropower generation is projected to increase modestly (+3%), with boosted generation in the winter (+9%) and spring (+5%) offsetting declined summer generation (−3.4%), suggesting strong adaptation potential for hydropower in the future energy portfolio. Further analysis reveals that the choice of GCM, particularly in western regions, has significant bearing on projected streamflow and hydropower changes.

13 HYDRO ENERGY↗

Facile Tensile Testing Platform for In Situ Transmission Electron Microscopy of Nanomaterials

In situ tensile testing using transmission electron microscopy (TEM) is a powerful technique to probe structure-property relationships of materials at the atomic scale. In this work, a facile tensile testing platform for in situ characterization of materials inside a transmission electron microscope is demonstrated. The platform consists of: 1) a commercially available, flexible, electron-transparent substrate (e.g., TEM grid) integrated with a conventional tensile testing holder, and 2) a finite element simulation providing quantification of specimen-applied strain. The flexible substrate (carbon support film of the TEM grid) mitigates strain concentrations usually found in free-standing films and enables in situ straining experiments to be performed on materials that cannot undergo localized thinning or focused ion beam lift-out. The finite element simulation enables direct correlation of holder displacement with sample strain, providing upper and lower bounds of expected strain across the substrate. The tensile testing platform is validated for three disparate material systems: sputtered gold-palladium, few-layer transferred tungsten disulfide, and electrodeposited lithium, by measuring lattice strain from experimentally recorded electron diffraction data. The results show good agreement between experiment and simulation, providing confidence in the ability to transfer strain from holder to sample and relate TEM crystal structural observations with material mechanical properties.

2D materials↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This paper presents a generic and multifunctional electromagnetic transient (EMT) dynamic model of grid-following (GFL) inverter-based resources (IBRs) using the PSCAD software platform. The features of the model include flexibility in selecting various types and combinations of DC sources covering photovoltaic modules, battery modules, and ideal DC-source modules as well as flexibility in selecting either switching or averaged models of the inverter. This model also covers exhaustive lists of controller algorithm, including open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control, and conventional current control designed in the dq-domain, the ..alpha....beta.. -domain, and the positive-/negative-sequence domain. Moreover, this model is equipped with flexibility in selecting various types of current-limiting schemes, including saturation-based and latching-based current limiters, and anti-windup protection. Also, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by complying with IEEE Std. 2800. The generality in the power circuits and the multifunctional options in the operation and control of the developed EMT model make it suitable for both academia and industry to study various power system aspects, including, but not limited to, the fault behavior of GFL IBRs, the impacts on the protection system, and the transient stability of a system interfaced with large numbers of GFL IBRs.

integrated circuit modeling↗

The Use of High-Density UN Fuel in Heat-Pipe Microreactors

Heat-pipe microreactors (HPMRs) are very small-scale nuclear reactors that employ heat pipes (HPs) for heat removal. HPMRs can be easily integrated with other forms of renewable energies, can be used for emergency responses to disaster relief zones, can be deployed in remote locations not connected to the grid, and can be removed from sites and replaced by new ones. HPMRs can also be used for space missions as HPs do not rely on gravity for heat transfer. Conventional fuel materials, such as uranium oxide (UO 2 ) and uranium oxycarbide (UCO), are currently considered in most existing HPMR designs, but ceramic uranium nitride (UN) fuel that has high uranium density, high thermal conductivity, and high melting point may become a better fuel candidate. Through neutronics calculations, this paper assesses the impact of using UN fuel in HPMRs with two different neutron spectra (fast and thermal) and two different fuel forms [traditional solid fuel pellets and TRi-structural-ISOtropic (TRISO) fuel compacts]. It was concluded that retrofitting HPMRs with UN fuel has the potential to reduce the initial 235 U enrichment requirement by ~3 wt% (to keep the same cycle length) or increase the cycle length (by keeping the same initial 235 U enrichment), which enables more compact and transportable HPMR core designs. However, using UN fuel decreases the control element worth [by up to 20% for the Special Purpose Reactor (SPR) and 5% for HP-MR] and is up to 80% more costly. Increasing 15 N enrichment can further decrease the initial 235 U enrichment requirement and increase the control element worth but is more costly. In conclusion, compared to fast-spectrum HPMRs fueled with solid pellet fuels, retrofitting UN fuel is more suitable for thermal-spectrum HPMRs fueled with TRISO fuel compacts, where the neutron spectrum hardening caused by using UN is less significant.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrated GW Farm ABM

This Data Repository includes data used for the integrated groundwater- farm ABM model, raw model output from scenario ensemble, and processed outputs that isolate the groundwater storage depletion outcomes for the 35,000 farm cells. Model Inputs: Farm ABM Inputs: This folder contains the input data used by the integrated groundwater - farm ABM modelling script (Python file) used for the high performance computing (HPC) experiments. The sub-folder "data inputs" contains all of the farm attribute data, while the three files in the folder have the hydrogeological data lookup table (NLDAS Cost Curve Attributes.csv), a lookup table (Theis well function table.csv) for the groundwater cost curve function, and the farm indexes and corresponding NLDAS ids for all of the cells run in this experiment (nldas farms subset final.csv). NLDAS Cost curve hydrogeological data: Hydrogeological data aggregated to 1/8 degree resolution and aligned with the NLDAS grid. Parameters include: water depth below ground surface [meters], subsurface porosity [unitless], aquifer depth from ground surface to aquifer bottom [meters], annual average recharge (USGS: mm, Doll: meters), and three different hydraulic conductivity (K) values (meters/day). The three K values represent the mean value from Gleeson et al. (2018), one standard deviation above the mean from Gleeson et al. (2018), and the de Graaf et al. 2020 modifications to certain lithologies. Additional information about these datasets and their processing are documented in the supplement to Yoon et al. 2025 (in review). Output: Raw outputs: This folder contains a .zip file that has model outputs for the entire scenario ensemble. There is one csv for each farm id, using the format "farm farmid cases.csv". The relationship between the farm id and NLDAS id is defined by the "nldas farms subset final.csv" located in the Farm ABM Inputs folder. Each csv has 625 rows, corresponding to 625 combinations of different scenario parameter values. Each row (scenario) represents the outcome of a 100 year simulation. Columns define scenario settings and summary statistics for each scenario. The first four columns define the scenario settings: "hydro ratio," "econ ratio," "K scenario," and "gamma scenario." The hydro and econ ratios are values passed to the modeling script that influence multipliers for other model parameters, as documented in the supplement to Yoon et al. 2025 (in review). The gamma multiplier is a coefficient multiplier applied to the baseline gamma values (values below 1 represent lower unobserved costs compared to baseline, values above 1 represent higher costs). The K scenario names represent K values of: "low": 0.5 m/d, "int 1": 2.5 m/d, "int 2": 10 m/d, "high": 50 m/d, and "gleeson": mean Gleeson K value. "Perc vol depleted" is the fraction of groundwater depleted at the end of the 100 simulation. Processed Output: Derived depletion outcomes from raw outputs: All of the individual csv files from the Raw outputs were aggregated into a single file that has the scenario settings and fraction depletion "Perc vol depleted" for every farm cell, for every scenario. The other two files define relationships between the farm id, NLDAS id, and local and major aquifer units, used for aquifer-level depletion analysis.

Agent based modeling↗

COMPUTATIONAL MODELING OF IGNITION AND PREMIXED FLAME PROPAGATION INITIATED BY A PRE-CHAMBER TURBULENT JET

Addressing the pressing need for reduced carbon emissions, Turbulent Jet Ignition (TJI) emerges as a promising technology for ultra-lean combustion, offering enhanced thermal efficiencies and minimized cyclic variability in spark-ignited engines. To facilitate rapid testing and integration of this technology, a robust computational modeling framework is crucial. This study delves into the predictive capabilities of computational models for main-chamber ignition and premixed flame propagation using a single-cycle TJI rig measured by Biswas et al. (Applied Thermal Engineering, vol 106, 2016). Employing an open-source compressible flow simulation solver with Large Eddy Simulation (LES) for turbulence modeling, the investigation integrates the conventional Laminar Finite Rate Chemistry (LFRC) model alongside the transported Probability Density Method (PDF) for turbulence-chemistry interaction. A fully-consistent Eulerian Monte-Carlo Fields (EMCF) method is utilized to approximate the transported PDF, while Interaction by Exchange with Mean is employed to close micro-mixing terms in stochastic differential equations. A reduced chemical reaction mechanism with 21 species and 84 reactions (DRM-19) is used for solving chemical kinetics, and a double Gaussian energy deposition model is used to approximate the spark ignition in the pre-chamber. An unstructured O-grid mesh with 0.3 million cells in the prechamber and 1 million cells in the main chamber is employed. Results are divided into two phases: pre-chamber initialization and full TJI simulations. Validation of the predicted pre-chamber flame propagation and the lean ignition in the main-chamber is carried out by using available experimental data. Under quiescent conditions, both the LFRC and transported PDF methods largely underestimate the flame speed and subsequent pressure growth in the pre-chamber. A linear momentum forcing technique is applied to investigate the impact of initial turbulence in the pre-chamber, demonstrating a notable influence on flame propagation. Fine-tuning of the forcing coefficient reproduces the sudden pressure growth observed in the experiment. The experimentally validated pre-chamber simulation serves as the initial condition for the full TJI simulations. It is found that the LFRC model fails to predict lean-ignition in the main-chamber, resulting in a misfiring event. Incorporation of turbulence-chemistry interaction using the transported PDF method substantially improves the prediction of the ignition event in the main-chamber, achieving fair qualitative agreement and quantitative validation of combustion parameters within ±10% of the reported experimental data. The rich simulation results consisting of a full set of statistical description of the thermo-chemical states enable us to gain deep insights into the ignition mechanisms in the main chamber, which is limited when done experimentally. A novel dual ignition phenomenon is revealed in the TJI rig for the first time. Initially, a primary ignition kernel is formed at a downstream location which eventually detaches from the main jet. As the jet momentum decreases, a secondary ignition event follows, this time at a more upstream location which eventually combines with the primary ignition kernel to form a single connected flame front. Investigation of these ignition sequences in chemical composition space reveal distinct differences between the two. The primary ignition event in the main-chamber is followed by a large concentration of active radicals from the pre-chamber jet, accelerating the chain-branching steps, characterizing what has been referred to as flame ignition. In contrast, the secondary ignition occurs in the absence of active radicals in the pre-chamber jet, hence characterized as jet ignition. Further analysis of the effect of pre-chamber jet characteristics on lean ignition in the main-chamber is conducted by setting up cases with different initial pressure ratios (por) between the two chambers, a non-dimensional parameter, ranging from 1.2 to 3.2. As the initial pressure ratio increases, jet momentum increases, with dual ignition observed in cases above por= 2.2. Case with por= 3.2 lead to misfiring. The effect of ignition sequence on global combustion characteristics of TJI is analyzed. Dual ignition events lead to non-monotonicity in combustion characteristics such as global reaction progress variable, flame penetration, and global heat release rate. In dual ignition events, although the rate of fuel consumption and global heat release rate is initially lower, the secondary ignition leads to a sudden increase in flame surface area, resulting in a sudden jump and promoting the overall performance of the TJI system.

42 ENGINEERING↗

Vadose and Saturated Zone Flow and Transport Model Package Report for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington

This model package report (MPR) documents the development of the integrated vadose and saturated zone flow and transport model developed for the performance assessment of Trenches 31 and 34 in the low-level burial grounds (LLBGs). This modeling capability is intended for use in addressing the analysis requirements outlined in DOE O 435.1, Chg 1, Radioactive Waste Management1. The overall objective of the modeling effort is to provide a basis for making informed disposal decisions pertinent to Trenches 31 and 34. The purpose of the MPR is to document the development of the three-dimensional numerical vadose zone and saturated flow and transport model test case and evaluate its adequacy to support the LLBG performance assessment. The purpose is not to present results for DOE 435.1 decision making. The use of the model to perform base case and sensitivity analysis for the LLBG performance assessment, including inputs and results, is documented separately in subsequent environmental calculation files. This report discusses the development and translation of the conceptual model for flow and contaminant transport into the LLBG performance assessment three-dimensional numerical flow and transport model evaluated using the Subsurface Transport Over Multiple Phases (STOMP©) simulator. The development of representative geologic framework is described along with the implementation of waste release models used to represent contaminant release from waste disposed in the trenches. The report also provides the technical basis for specific model parameters and boundary conditions, along with description of modeling assumptions. This MPR includes certain calculations that are necessary to demonstrate the soundness of the model. Results provided by the model include vadose zone and saturated zone flow fields, and estimates of the possible future concentration in groundwater of technetium-99 and iodine-129 as example test cases. As an evaluation of the test cases, the model estimates of current vadose conditions are compared to available and analogous field and laboratory data, and compared to the results from the original performance assessment model (WHC-EP-0645, Performance Assessment for the Disposal of Low-Level Waste in the 200 West Area Burial Grounds 2 ). The features, events, and processes applicable to vadose zone and saturated zone flow and transport model are identified, and representative initial estimates for various parameters are documented. Note that the parameter estimates presented in this MPR are for illustration purposes, and may or may not reflect values selected for eventual performance assessment. Several key topical discussions (i.e., basis for recharge estimates, basis for vadose zone modeling, basis for saturated zone model development, and calibration) are included, which serve as the groundwork for confidence building for the groundwater pathway modeling and results. Numerical simulation results based on an example test case are included to illustrate the use of the combined saturated-unsaturated model in performance assessment calculations. Sensitivity and uncertainty results are not included in this MPR. Those results will be included in future environmental calculation files. The inclusion of the trapezoidal trench geometry and construction details in the finite difference grid introduces some gross simplifications regarding the trench and liner systems. The model test case presented in this MPR includes the assumption that the trench liner system does not affect flow through or around the trenches after the liner system is assumed to fail. This MPR also includes results of other test cases that involve alternate assumptions about how to incorporate the hydraulic effects of the trenches into the vadose zone of the model. These alternate cases do not attempt to account for the presence of the liner system after its assumed failure either. None of these cases is considered to be the base case at this time. Analysis and alternate cases that attempt to account for the presence of the liner system in greater detail, and its effect on flow through and around it, are to be documented in subsequent environmental calculation files. Depending on the results of those analyses and alternate cases, the eventual base case may involve more detailed inclusion of the effects of the liner system hydraulics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid Evaluation Framework for the CMIP7 Assessment Fast Track

As Earth system models (ESMs) grow in complexity and in volume of output data, there is an increasing need for rapid, comprehensive evaluation of their scientific performance. The upcoming Assessment Fast Track for the Seventh Phase of the Coupled Model Intercomparison Project (CMIP7) will require expeditious response for model analyses designed to inform and drive integrated Earth system assessments. To meet this challenge, the Rapid Evaluation Framework (REF), a community-driven platform for benchmarking and performance assessment of ESMs, was designed and developed. The initial implementation of the REF, constructed to meet the near-term needs of the CMIP7 Assessment Fast Track, builds upon four disparate community evaluation and benchmarking tools that are coupled together using the Coordinated Model Evaluation Capabilities (CMEC) framework. The REF runs within a containerized workflow for portability and reproducibility and is aimed at generating and organizing diagnostics covering a variety of model variables. The REF leverages well documented observational datasets to provide assessments of model fidelity across a collection of diagnostics. All diagnostics were identified and selected with community involvement and consultation. Operational integration with the Earth System Grid Federation (ESGF) will permit automated execution of the REF for selected diagnostics as soon as model output data are published on ESGF by the originating modeling centers. The REF is designed to be portable across a range of current computational platforms to facilitate use by modeling centers for assessing the evolution of model versions or gauging the relative performance of CMIP simulations before being published on ESGF. When integrated into production simulation workflows, results from the REF provide immediate quantitative feedback that allows model developers and scientists to quickly identify model biases and performance issues. After the REF is released to the community, its subsequent development and support will be prioritized by an international consortium of scientists and engineers, enabling a broader impact across Earth science disciplines. For instance, the REF will facilitate improvements to models and will enhance confidence in model projections through process-based selection of models based on their performance with respect to observations. Production of reproducible diagnostics and community-based assessments are key features of the REF. Furthermore, providing interoperability with existing evaluation packages assures that contributions from previous community efforts will be available for use in future model intercomparison projects.

Hoffman, Forrest [ORNL] (ORCID:0000000158024134)↗

U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base

Motor systems are an integral part of our industrial and commercial facilities. They provide the motive force behind the fans, pumps, compressors, chillers, and conveyors in these facilities. Given their centrality to any facility’s operations, they are a critical energy end use to understand, particularly when developing technologies and policies to meet sustainability goals, improve productivity, and enhance resilience. In the late 1990s, the U.S. Department of Energy (DOE) conducted two seminal studies to better understand the installed stock and energy savings opportunities of industrial and commercial motor systems. In the industrial sector, The United States Industrial Electric Motor Systems Market Opportunities Assessment used primary data collected through onsite assessments and led to a greater understanding of the installed base of motor systems, their characteristics, and the opportunities for energy savings (U.S. Department of Energy, 2002). Notable findings included the following: Industrial motor systems consumed 679 billion kilowatt-hours (kWh) in 1994, representing 23 percent of U.S. electricity consumption. Cost-effective energy efficiency measures could result in 62-104 billion kWh of energy savings annually. Sixty-two percent of the energy savings potential was from fan, pump, and compressor end use equipment. Nearly half of motor system electricity consumption was attributable to approximately 3,500 facilities, or 1.5 percent of U.S. manufacturing facilities. Opportunities for Energy Savings in the Residential and Commercial Sectors with High Efficiency Electric Motors provided an evaluation of the installed stock of motor driven equipment in U.S. commercial and residential buildings and opportunities for utilization of high efficiency motors and variable speed technologies (Arthur D. Little, 1999). Notable findings included the following: Commercial motor systems consumed 343 billion kWh in 1995, with refrigeration and space conditioning constituting 93 percent of the total. Cost-effective energy efficiency measures could result in 51 billion kWh of energy savings annually. Due in no small part to these seminal studies, motor system technologies and usage characteristics have changed drastically since the late 1990s. Greater awareness of cost-effective strategies for reducing motor system electricity consumption have been developed and deployed. This includes several software tools, literature, and utility and government programs promoting energy efficiency improvements in motor driven systems. Additionally, several rounds of energy efficiency standards have been enacted, resulting in improved installed motor efficiency. The cost of variable speed drives has dropped substantially, and combined with utility rebate programs, has led to their greater adoption. Further, since these results were published, the U.S. manufacturing sector has undergone a massive transformation. Due to global competition, some sectors have relocated operations overseas. Others have brought operations onshore to avail low cost and abundant natural gas. Additionally, automation and robotics have pervaded the entire sector. Consequently, these two reports likely do not represent the current state of motor driven systems in U.S. industrial and commercial facilities. As cited in recent studies, the lack of current information on motor system electricity consumption and use characteristics limits the ability to conduct analysis on energy savings potential, develop technologies to address energy and productivity gaps, and develop programs to promote energy efficiency practices and technologies for motor systems (International Energy Agency, 2007; UNIDO, 2010; McKane and Hasanbeigi, 2011; Waide and Brunner, 2011). Specifically, the lack of information affects a range of stakeholders: Governments must rely on outdated information when setting research agendas, developing policies, and designing energy efficiency programs and offerings. Utilities and energy efficiency programs cannot identify the current market needs or potential impact when designing rebate and energy efficiency programs. Electric grid planners cannot identify motor system usage characteristics when developing plans to support the resilience of the electric grid. Manufacturers of motors, motor driven equipment, and drives are hampered when developing technologies to meet the needs of their market. Motor system end users are limited in their ability to identify energy saving opportunities within their own facilities because they do not have reliable benchmark information. In response to the lack of current information and analysis on industrial and commercial motor systems, the DOE initiated an update to these two studies. Launched in 2016 and led by Lawrence Berkeley National Laboratory (LBNL), the Motor System Market Assessment (MSMA) provides an updated, more comprehensive assessment of the installed stock of motor systems in both the industrial and commercial sectors, a review of the supply chains supporting motor and drives in the U.S., and the performance improvement opportunity available from using best available technologies and maintenance and operation practices. The outcomes of the MSMA are documented in three U.S. Industrial and Commercial Motor System Market Assessment reports, with this report being the first listed: 1. Volume 1: Characteristics of the Installed Base (this report) documents the findings on the installed base of motor systems in the U.S. industrial and commercial sectors. Quantification of energy savings potential is not documented in this report but in Volume 3. 2. Volume 2: Motors and Drives Supply Chain Review reviews the state of supply chains for motors and drives installed in U.S. industrial and commercial facilities, focusing on advanced motor and drive technologies and their constituent materials. 3. Volume 3: Energy Savings Opportunity analyzes the energy performance improvement opportunity for the installed base of U.S. industrial and commercial motor systems. This report has been prepared as a reference for motor system stakeholders. It provides factual information as could be best determined by the assessment results and avoids speculating on any findings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fostering a Guiding Multiscale Model for the Development of Advanced MgB 2 Hydrogen Storage Materials (Final Technical Report)

Project Goal and Objective. The demand for energy and for an upgraded energy infrastructure has steadily grown, as have the needs for energy independence and alternatives to our reliance on petroleum. Hydrogen is considered the most viable fuels for wide-scale implementation in the near future as it is less-polluting, non-toxic, and has more stored energy than petroleum. It is envisioned that hydrogen can eventually become the prime energy carrier, integrating the transportation, grid, and chemical sectors in a way that improves resiliency, diversifies feedstocks, and affords new economic opportunities. A key remaining challenge is the development materials with enhanced gravimetric and volumetric hydrogen storage capacities that offer a higher performance than compressed gas. These materials would eliminate the need for large-scale compression, thereby dramatically reducing the footprint and cost of gas storage. The high gravimetric and volumetric hydrogen capacities of complex hydrides has prompted an intensive investigation of the potential of this class of materials as hydrogen storage media over the past 25 years. Among the many complex hydrides that have been explored, magnesium borohydride, Mg(BH 4 ) 2 , has been found to possess the best combination of practical thermodynamic properties. These include a gravimetric H 2 density of 14.9 wt% H 2 and thermodynamics for the dehydrogenation of Mg(BH 4 ) 2 to MgB 2 (equation 1) (ΔH° = 39 kJ/mol H 2 , ΔS = 112 J/K mol H 2 ) which lie in the narrow window required Mg(BH 4 ) 2 $\Leftrightarrow$ MgB 2 + 4 H 2 (1) for reversibility under moderate pressure and temperature. However, overcoming the extremely slow kinetics of the reversible release of hydrogen by this material in the solid state is a daunting challenge. At temperatures greater than 400 °C, the borohydride releases up to 14 wt% hydrogen giving MgB 2 . We discovered that the direct re-hydrogenation of MgB 2 to Mg(BH 4 ) 2 can be accomplished under 950 bar H 2 at 400 °C. While this demonstrated that complete reversibility can be achieved, the conditions employed are far too extreme for commercial hydrogen storage applications. More recently, we found through US DOE funded research projects (EERE HyMARC and HySCOR), that hydrogen cycling, can be accomplish at much milder conditions upon modification of the borohydride or boride. Guided by these discoveries these discoveries, the objective of this research project was to obtain key information that will enable the development of a model of reversible hydrogenation of MgB 2 to Mg(BH 4 ) 2 . The ultimate goal of our efforts is to attain a model of this transformation that can be utilized to accelerate development further advanced materials. This project directly follows on discoveries that were made over the course of a US DOE, EERE HyMARC project that was focused on improvement of the hydrogen cycling kinetics of modified MgB 2 . We found that that mechanical milling with graphene results the desired, pronounced kinetic enhancement. The dramatic lowering of the conditions required for the hydrogenation of MgB 2 is a significant step towards overcoming its chemical inertness allowing its development as a practical onboard hydrogen storage material. However, the exact nature of the modification(s) of MgB 2 that is responsible for its activation towards hydrogenation is completely unknown. This situation is not unique, as efforts to develop hydrogen storage materials typically have a narrow focus rather than a comprehensive approach that takes atomic level bonding and structure; molecular dynamics; long range, nano- and mesoscale-structure and their interconnection all into account. The goal of this project was the development of a comprehensive, multi-scale computational model of reversible hydrogenation of MgB 2 to Mg(BH 4 ) 2 that can be utilized for development of higher performance versions of the modified material. Development of the model requires determination of: 1) the bulk, nano-scale, and meso-scale structural changes occurring at elevated pressure following mechano-chemical modification of MgB 2 ; 2) the reaction pathway of the reversible hydrogenation of MgB 2 to Mg(BH 4 ) 2 ; 3) the effect of elevated pressure and mechano-chemical modification on the chemical reaction pathways; 4) the interactions at solid-gas interfaces; and particle surfaces; and 5) the kinetics and thermodynamic parameters associated with each step of the hydrogenation reaction pathway. This investigation required advanced techniques as preliminary, standard XRD, 11 B NMR, and FTIR analysis showed no signs of material modification. In order to gain this level of understanding of modified MgB 2 , required the teaming of a diverse group of experts and state-of-the art experimental capabilities at the University of Hawaii at Manoa (UHM) and collaborating National Laboratories: Craig Jensen , Department of Chemistry (PI and Project Director), solid state, solution, and high pressure NMR spectroscopy; solid-state synthesis; and high pressure hydrogenation (collaboration with SNL); Godwin Severa , Hawaii Natural Energy Institute (co-PI) calorimetry; infrared and Raman spectroscopy (collaboration with NREL); Dera , high pressure X-ray diffraction including in situ experiments (collaboration with ANL); Hope Ishii , Hawaii Institute of Geophysics electron microscopy investigations (collaboration with LBNL); and Joe Brown , Mechanical Engineering , material electronic structure and electric field effects.

08 HYDROGEN↗

Metadata Schemas and Ontologies for Building Energy Applications: A Critical Review and Use Case Analysis

With the increasing digitalization of processes throughout the lifecycle of buildings, data exchanged between stakeholders and between building systems has grown significantly. However, a lack of semantic interoperability between data in different systems is still prevalent, hindering the development of applications that can be reused across buildings and limiting the scalability of innovative solutions. Semantics refers to the description of the meaning of the data in a way that can be consistently understood by applications. Recently, several competing initiatives have been developing metadata schemas and ontologies to express this semantic information for different applications in the building domain. This paper systematically reviews these schemas and conducts an analysis of five of them to evaluate their applicability to three high-value use cases for building operations: energy audits, automated fault detection and diagnostics and optimal control. The survey finds 40 schemas published in the last 10 years but but their actual use in industry is difficult to estimate. Among the five selected ontologies, several gaps are highlighted in relation to the three use cases. Recommendations for the future include better harmonization of these initiatives, more centralized repositories and search engines for these schemas as well as better industry engagement to facilitate their adoption.

Smart Building, Sematic, Metadata, Ontology, Data ↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗