Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Fabry-Perot observations of comet Austin

Preliminary results of a program to observe Comet Austin (1990c1) from 16 April to 4 May and from 11 May to 27 May 1990 using the West Auxiliary of the McMath Solar Telescope on Kitt Peak, Arizona were presetned. The observations were made with a 15 cm duel-etalon Fabry-Perot scanning and imaging spectrometer with two modes of operation: a high resolution mode with a velocity resolution of 1.2 km/s and a medium resolution mode with a velocity resolution 10 km/s. Scanning data was obtained with an RCA C31034A photomultiplier tube and imaging data was obtained with a Photometrics LN2 cooled CCD camera with a 516 by 516 Ford chip. The results include: (1) information on the coma outflow velocity from high resolution spectral profiles of (OI)6300 and NH2 emissions, (2) gaseous water production rates from medium resolution observation of (OI)6300, (3) spectra of H2O(+) emissions in order to study the ionized component of the coma, (4) spatial distribution of H2O(+) emission features from sequences of velocity resolved images (data cubes), and (5) spatial distribution of (OI)6300 and NH2 emissions from medium resolution images. The field of view on the sky was 10.5 arcminutes in diameter. In the imaging mode the CCD was binned 4 by 4 resulting in 7.6 sec power pixel and a subarray readout for a field of view of 10.5 min.

Schultz, David↗

Science requirements for Heavy Nuclei Collection (HNC) experiment on NASA Long Duration Exposure Facility (LDEF) Mission 2

The Heavy Nuclei Collection (HNC) is a passive array of stacks of a special glass, 14 sheets thick, that record tracks of ultraheavy cosmic rays for later readout by automated systems on Earth. The primary goal is to determine the relative abundances of both the odd- and even-Z cosmic rays with Z equal to or greater than 50 with statistics a factor at least 60 greater than obtained in HEAO-3 and to obtain charge resolution at least as good as 0.25 charge unit. The secondary goal is to search for hypothetical particles such as superheavy elements. The HNC detector array will have a cumulative collection power equivalent to flying 32 sq m of detectors in space for 4 years. The array will be flown as a free-flight spacecraft and/or attached to Space Station Freedom.

Price, P. Buford↗

CCD observations of orbital debris

A portable 31 cm aperture f/1.3 Schmidt telescope with a CCD sensor at the prime focus has been designed and constructed to carry out photometric studies of earth-orbiting debris. When operated in the time delay integration mode in which the readout rate is matched to the predicted motion of the satellite, this system reaches a limiting diameter of about 10 cm for particles at 400 km height and albedo 0.1. It is used for statistical studies of phase angle effects and for swarm-to-swarm albedo differences between several selected debris groups which include the Cosmos 1275, Cosmos 1375, Landsat 1, Landsat 3, NOAA 3, Nimbus 4, Solwind, and Spot-1/Viking groups.

Henize, Karl G.↗

Charge transfer efficiency measurements at low signal levels on STIS/SOHO TK1024 CCD's

Charge transfer efficiency (CTE) test methods are reviewed, and the results and conclusions of the tests are given. The test methods have been utilized to describe the CTE characteristics of the Tektronix 1024 by 1024 CCD to optimize low dark current, low readout noise, and high CTE at low signal levels. CTE modelling is described, and three test methods are set forth and compared. The Fe-55 X-ray response method utilizes the response of a CCD to X-ray photons from the radioactive source Fe-55. The extended pixel edge response method employs the measurement of the charge lost to successive pixels by a known initial signal as it is shifted through the array. The charge injection method consists of charge injection through the output amplifier reset transistor. These measurements were performed on several devices with known CTEs. The CTEs are found to be in agreement for the three methods, making application and test requirements the principal criteria for their use.

Orbock, J. D.↗

Radiation damage in a Tektronix 512 CCD

A Tektronix CCD was subjected to a proton beam. Comparisons were made of the CCD characteristics before, during, and after radiation. Gain and readout noise were not affected and charge transfer efficiency, full well, and dark current were. Permanent CTE damage resulted immediately upon radiation, but full well damage developed two days after radiation, while the dark current showed signs of recovery before permanent damage occurred. Histogram analysis showed that the most spiky-type behavior resulted from damage to defects existing in the CCD before radiation.

Brown, Larry W.↗

Imaging capabilities of SXT for Solar-A

The present study characterizes the Soft X-ray Telescope (SXT), a grazing-incidence solar X-ray telescope which will be flown on the Japanese Solar-A satellite. X-ray tests showed that the SXT mirror meets or exceeds design requirements. SXT advantages over Skylab are: improved time resolution (not less than 0.5 s), greatly decreased mirror scatter, coaligned aspect telescope to intersperse images of sunspots and magnetic plage, and digital data readout.

Lemen, J. R.↗

Photoelastic transducer for high-temperature applications

A design for a birefringence transducer for high-temperature applications is described. The spring element and the readout instrumentation are addressed. A pressure transducer based on the concept has been built and successfully tested at temperatures up to 600 C.

Redner, A. S.↗

Characterisation of frequency doubling in Eu(2+) doped aluminosilicate fibres

The results of a series of experiments on efficient second-harmonic generation in a fiber with a Eu(2+)-doped aluminosilicate core are reported. The fiber was prepared by the seeding method with CW mode-locked radiation at 1.06 micron and produced ultrastable peak conversion efficiencies of 0.001 during mode-locked readout. Experiments were performed to determine the IR preparation intensity dependence, the stability of the output, and the type of erasure mechanisms which occur. The results are compared with those of germanosilicate fibers and some similarities and differences are discussed.

Driscoll, T. J.↗

Performances Of Arrays Of Ge:Ga Far-Infrared Detectors

Report presents evaluation of performances of two electronic modules containing few-element linear focal-plane arrays of Ge:Ga photodetectors and associated multiplexing readout circuitry. Tested to demonstrate feasibility of many-element, two-dimensional focal-plane arrays of far-infrared detectors and associated circuitry for use in astronomical and other low-background scientific observations. Revealed deficiencies that must be overcome in future designs.

Mccreight, C.↗

Si1-XGex/Si-Heterojunction Internal-Photoemission Detectors

Cutoff wavelengths tailored by choice of Ge content. Infrared detectors based on internal photoemission at Si1-xGex/Si heterojunctions exhibited photoresponses at wavelengths from 2 to 12 micrometers in initial tests. Si1-xGex/Si-heterojunction internal-photoemission detectors tailored for use at wavelengths of order of 10 micrometers. Future developments expected to include integration of such devices with silicon readout circuitry to form infrared-imaging arrays. Imaging arrays operating in important wavelength range of 8 to 12 micrometers can be fabricated relatively inexpensively for use in outer-space, military, and industrial applications.

Lin, True-Lon↗

Thermal response of large area high temperature superconducting YBaCuO infrared bolometers

Thermal analysis of large area high temperature superconducting infrared detector operating in the equilibrium mode (bolometer) was performed. An expression for the temperature coefficient beta = 1/R(dR/dT) in terms of the thermal conductance and the thermal time constant of the detector were derived. A superconducting transition edge bolometer is a thermistor consisting of a thin film superconducting YBaCuO evaporated into a suitable thermally isolated substrate. The operating temperature of the bolometer is maintained close to the midpoint of the superconducting transition region where the resistance R has a maximum dynamic range. A detector with a strip configuration was analyzed and an expression for the temperature rise (delta T) above the ambient due to a uniform illumination with a source of power density was calculated. An expression for the thermal responsibility depends upon the spatial modulation frequency and the angular frequency of the incoming radiation. The problem of the thermal cross talk between different detector elements was addressed. In the case of monolithic HTS detector array with a row of square elements of dimensions 2a and CCD or CID readout electronics the thermal spread function was derived for different spacing between elements.

Khalil, Ali E.↗

Report of the ultraviolet and visible sensors panel

In order to meet the science objectives of the Astrotech 21 mission set the Ultraviolet (UV) and Visible Sensors Panel made a number of recommendations. In the UV wavelength range of 0.01 to 0.3 micro-m the focus is on the need for large format high quantum efficiency, radiation hard 'solar-blind' detectors. Options recommended for support include Si and non-Si charge coupled devices (CCDs) as well as photocathodes with improved microchannel plate readouts. For the 0.3 to 0.9 micro-m range, it was felt that Si CCDs offer the best option for high quantum efficiencies at these wavelengths. In the 0.9 to 2.5 micro-m the panel recommended support for the investigation of monolithic arrays. Finally, the panel noted that the implementation of very large arrays will require new data transmission, data recording, and data handling technologies.

Timothy, J. Gethyn↗

Report of the direct infrared sensors panel

The direct infrared sensors panel considered a wide range of options for technologies relevant to the science goals of the Astrotech 21 mission set. Among the technologies assessed are: large format arrays; photon counting detectors; higher temperature 1 to 10 micro-m arrays; impurity band conduction (IBC) or blocked impurity band (BIB) detectors; readout electronics; and adapting the Space Infrared Telescope Facility and Hubble Space Telescope. Detailed development plans were presented for each of these technology areas.

Mccreight, Craig↗

Ambient temperature recorder

A temperature data recorder, designated the Ambient Temperature Recorder (ATR-4), was developed at NASA Ames Research Center to meet particular requirements for space life sciences experiments. The small, self-contained, four-channel, battery-powered device records 32 kilobytes of temperature data over a range of -40 to +60 C at four sampling intervals ranging from 1.875 to 15 minutes. Data is stored in its internal electronic memory for later readout by a personal computer.

Russell, Larry D.↗

128 layer HYMOSS module fabrication issues

The fabrication of the first Z-technology module with 128 active layers of readout electronic circuitry is being pursued. Several issues which will be investigated regarding the 128-layer module build, such as photolithographic processing at the edge of the module (edge effects) and module buttability, are discussed in this paper. Other topics which are covered apply to future applications of fully populated HYMOSS modules. These topics include possible reductions of thermal mass for quick cool-down time applications and improvements of end-to-end yield for low-cost applications.

Ludwig, David E.↗

The Berkeley EUV spectrometer for ORFEUS

A novel EUV spectrometer is presented for the ORFEUS-SPAS mission. It uses a set of four varied line-space spherical diffraction gratings to obtain high-resolution spectra of point sources at wavelengths between 390 and 1200 A. The spectra are recorded with two detector units, each containing curved-surface microchannel plates and a delay-line anode-readout system. An independent optical system detects the image of the source in the entrance aperture and tracks the source as it drifts during an observation, enabling a reconstruction of the spectra postflight. The overall system performance is discussed and illustrated by synthetic spectra.

Hurwitz, M.↗

Technology development program for the Space Infrared Telescope Facility (SIRTF) science instruments

A coordinated technology program for the Space Infrared Telescope Facility (SIRTF) is described. The program encompasses detector technology, cryogenic mechanisms technology, and an adiabatic demagnetization refrigerator. Discrete detectors, detector arrays, detector readouts, and testing of engineering models under simulated flight environment conditions are considered. Several focal planes will be optimized at a particular wavelength range to make up over 247,000 detector pixels from about 1.8 to 1000 microns.

Ramos, Ruben↗