Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Deeply Virtual Compton Scattering Using a Positron Beam in Hall-C at Jefferson Lab

In this study we propose to use the High Momentum Spectrometer of Hall C combined with the Neutral Particle Spectrometer (NPS) to perform high precision measurements of the Deeply Virtual Compton Scattering (DVCS) cross section using a beam of positrons. The combination of measurements with oppositely charged incident beams is the only unambiguous way to disentangle the contribution of the DVCS 2 term in the photon electroproduction cross section from its interference with the Bethe-Heitler amplitude. This provides a stronger way to constrain the Generalized Parton Distributions of the nucleon. A wide range of kinematics accessible with an 11 GeV beam off an unpolarized proton target will be covered. The $\mathcal{Q}^2$-dependence of each contribution will be measured independently.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long-baseline neutrino oscillation physics potential of the DUNE experiment

The sensitivity of the Deep Underground Neutrino Experiment (DUNE) to neutrino oscillation is determined, based on a full simulation, reconstruction, and event selection of the far detector and a full simulation and parameterized analysis of the near detector. Detailed uncertainties due to the flux prediction, neutrino interaction model, and detector effects are included. DUNE will resolve the neutrino mass ordering to a precision of 5σ, for all δ CP values, after 2 years of running with the nominal detector design and beam configuration. It has the potential to observe charge-parity violation in the neutrino sector to a precision of 3σ (5σ) after an exposure of 5 (10) years, for 50% of all δ CP values. It will also make precise measurements of other parameters governing long-baseline neutrino oscillation, and after an exposure of 15 years will achieve a similar sensitivity to sin 2 2$θ_{13}$ to current reactor experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Suppression of Penning discharges between the KATRIN spectrometers

Abstract The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)-neutrino mass with a sensitivity of 0.2eV/c $$^2$$ 2 by precisely measuring the endpoint region of the tritium $$\beta $$ β -decay spectrum. It uses a tandem of electrostatic spectrometers working as magnetic adiabatic collimation combined with an electrostatic (MAC-E) filters. In the space between the pre-spectrometer and the main spectrometer, creating a Penning trap is unavoidable when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, “electron catchers” were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Das ist der HAMMER: consistent new physics interpretations of semileptonic decays

Abstract Precise measurements of $$b\rightarrow c\tau \bar{\nu }$$ b → c τ ν ¯ decays require large resource-intensive Monte Carlo (MC) samples, which incorporate detailed simulations of detector responses and physics backgrounds. Extracted parameters may be highly sensitive to the underlying theoretical models used in the MC generation. Because new physics (NP) can alter decay distributions and acceptances, the standard practice of fitting NP Wilson coefficients to SM-based measurements of the $$R(D^{(*)})$$ R ( D ( ∗ ) ) ratios can be biased. The newly developed software tool enables efficient reweighting of MC samples to arbitrary NP scenarios or to any hadronic matrix elements. We demonstrate how allows avoidance of biases through self-consistent fits directly to the NP Wilson coefficients. We also present example analyses that demonstrate the sizeable biases that can otherwise occur from naive NP interpretations of SM-based measurements. The library is presently interfaced with several existing experimental analysis frameworks and we provide an overview of its structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The cosmic muon and detector simulation framework of the extreme energy events (EEE) experiment

Abstract This paper describes the simulation framework of the extreme energy events (EEE) experiment. EEE is a network of cosmic muon trackers, each made of three multi-gap resistive plate chambers (MRPC), able to precisely measure the absolute muon crossing time and the muon integrated angular flux at the ground level. The response of a single MRPC and the combination of three chambers have been implemented in a GEANT4-based framework (GEMC) to study the telescope response. The detector geometry, as well as details about the surrounding materials and the location of the telescopes have been included in the simulations in order to realistically reproduce the experimental set-up of each telescope. A model based on the latest parametrization of the cosmic muon flux has been used to generate single muon events. After validating the framework by comparing simulations to selected EEE telescope data, it has been used to determine detector parameters not accessible by analysing experimental data only, such as detection efficiency, angular and spatial resolution.

Abbrescia, M.↗

Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor

Abstract The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 m away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet Collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment’s shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $$^3$$ 3 He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance. Our results show that depending on the effectiveness of the muon veto, we expect a total nuclear recoil background rate between 44 ± 3 and 9 ± 2 events/day/kg in the CENNS region of interest, i.e. between 50 eV and 1 keV. We therefore found that the Ricochet experiment should reach a statistical significance of 4.6 to 13.6 $$\sigma $$ σ for the detection of CENNS after one reactor cycle, when only the limiting neutron background is considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First demonstration of a TES based cryogenic Li 2 MoO 4 detector for neutrinoless double beta decay search

Cryogenic calorimetric experiments to search for neutrinoless double-beta decay (0vββ) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li 2 100 MoO 4 detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targeting this second stage with a low impedance TES based readout for the Li 2 MoO 4 absorber that is easily mass-produced and lends itself to a multiplexed readout. We present the detector design and results from a first prototype detector operated at the NEXUS shallow underground facility at Fermilab. The detector is a 2-cm-side cube with 21 g mass that is strongly thermally coupled to its readout chip to allow rise-times of ~0.5 ms. This design is more than one order of magnitude faster than present NTD based detectors and is hence expected to effectively mitigate backgrounds generated through the pile-up of two independent two neutrino decay events coinciding close in time. Together with a baseline resolution of 1.95 keV (FWHM) these performance parameters extrapolate to a background index from pile-up as low as 5 • 10 –6 counts/keV/kg/yr in CUPID size crystals. The detector was calibrated up to the MeV region showing sufficient dynamic range for 0vββ searches. In combination with a SuperCDMS HVeV detector this setup also allowed us to perform a precision measurement of the scintillation time constants of Li 2 MoO 4 , which showed a primary component with a fast O(20 μs) time scale. Similar content being viewe

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reweighting simulated events using machine-learning techniques in the CMS experiment

Data analyses in particle physics rely on an accurate simulation of particle collisions and a detailed simulation of detector effects to extract physics knowledge from the recorded data. Event generators together with a GEANT -based simulation of the detectors are used to produce large samples of simulated events for analysis by the LHC experiments. These simulations come at a high computational cost, where the detector simulation and reconstruction algorithms have the largest CPU demands. This article describes how machine-learning (ML) techniques are used to reweight simulated samples obtained with a given set of parameters to samples with different parameters or samples obtained from entirely different simulation programs. The ML reweighting method avoids the need for simulating the detector response multiple times by incorporating the relevant information in a single sample through event weights. Results are presented for reweighting to model variations and higher-order calculations in simulated top quark pair production at the LHC. This ML-based reweighting is an important element of the future computing model of the CMS experiment and will facilitate precision measurements at the High-Luminosity LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Future Circular Collider Feasibility Study Report

Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools/reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. The content and structure of this report are guided by the scope and priorities defined in the mandate of the FCC Feasibility Study. It is therefore not intended to serve as an exhaustive review of the full physics potential of FCC. Several topics, already covered in earlier reports such as the FCC CDR, are not reiterated here or are addressed only briefly, in alignment with the study’s focus. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.

Benedikt, M. [European Organization for Nuclear Re↗

Status and results from the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is a tonne-scale cryogenic experiment located at the Laboratori Nazionali del Gran Sasso that exploits bolometric technique to search for neutrinoless double beta decay [0$vββ$] of 130 Te. The detector consists of a segmented array of 988 natural TeO 2 cubic crystals arranged in a cylindrical compact structure of 19 towers. The detector construction was completed in August 2016 and data taking started in Spring 2017. Here, we present a brief description of the bolometric technique for rare events search and the CUORE detector, then we concentrate on the data analysis results. In this respect, we focus on the procedure for data processing and on the first 0$vββ$ results we obtained from a total TeO 2 exposure of 86.3 kg · yr. Next, we illustrate the main background sources and the CUORE background model, from which we obtain the most precise measurement of 130 Te 2$vββ$ half-life to date. Finally, we discuss the improvements achieved with 2018 and 2019 detector optimization campaigns and the current perspectives of our experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultrasonic Resonance Techniques for Materials Research

Mechanical resonances are directly related to the physical behavior of a system at the bulk and microscopic levels. In materials science, resonant ultrasound spectroscopy (RUS) has long been a preferred nondestructive method to study mechanical resonances of solids and precisely measure quantitative material properties, namely elasticity. In recent years, advances in computational power and hardware have enabled RUS to be relevant for an increasing range of applications, such as advanced manufacturing. An extension of this technique, nonlinear RUS (NRUS), has been demonstrated to provide unmatched sensitivity to early-stage damage. NRUS was originally developed to probe geologic materials but has become a vital tool in nondestructive evaluation and materials research, offering a powerful means of quantifying and characterizing microstructural nonlinearity in a broad range of materials. This review summarizes recent developments and growth opportunities in RUS and NRUS techniques, modeling, and applications across a wide range of material systems including metals, composites, geomaterials, and explosives.

36 MATERIALS SCIENCE↗

Probing the Neutrino-Mass Scale with the KATRIN Experiment

The absolute mass scale of neutrinos is an intriguing open question in contemporary physics. The as-yet-unknown mass of the lightest and, at the same time, most abundant massive elementary particle species bears fundamental relevance to theoretical particle physics, astrophysics, and cosmology. The most model-independent experimental approach consists of precision measurements of the kinematics of weak decays, notably tritium β decay. With the KATRIN experiment, this direct neutrino-mass measurement has entered the sub-eV domain, recently pushing the upper limit on the electron-based neutrino mass down to 0.8 eV (90% CL) on the basis of first-year data out of ongoing, multiyear operations. Here, we review the experimental apparatus of KATRIN, the progress of data taking, and initial results. While KATRIN is heading toward the target sensitivity of 0.2 eV, other scientific goals are pursued. We discuss the search for light sterile neutrinos and an outlook on future keV-scale sterile-neutrino searches as well as further physics opportunities beyond the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of proton deflectometry with in situ x-ray fiducial for magnetized high-energy-density systems

We report a design and implementation of proton deflectometry with an in situ reference x-ray image of a mesh to precisely measure non-uniform magnetic fields in expanding plasmas at the OMEGA and OMEGA EP laser facilities. The technique has been developed with proton and x-ray sources generated from both directly driven capsule implosions and short pulse laser–solid interactions. The accuracy of the measurement depends on the contrast of both the proton and x-ray images. Here we present numerical and analytic studies to optimize the image contrast using a variety of mesh materials and grid spacings. Our results show clear enhancement of the image contrast by factors of four to six using a high Z mesh with large grid spacing. This leads to further improvement in the accuracy of the magnetic field measurement using this technique in comparison with its first demonstration at the OMEGA laser facility [Rev. Sci. Instrum. 93, 023502 (2022) [CrossRef]].

47 OTHER INSTRUMENTATION↗

Pulse-burst spontaneous Raman thermometry of unsteady wave phenomena in a shock tube

A high-speed temperature diagnostic based on spontaneous Raman scattering (SRS) was demonstrated using a pulse-burst laser. The technique was first benchmarked in near-adiabatic H 2 -air flames at a data-acquisition rate of 5 kHz using an integrated pulse energy of 1.0 J per realization. Both the measurement precision and accuracy in the flame were within 3% of adiabatic predictions. Furthermore, this technique was then evaluated in a challenging free-piston shock tube environment operated at a shock Mach number of 3.5. SRS thermometry resolved the temperature in post-incident and post-reflected shock flows at a repetition rate of 3 kHz and clearly showed cooling associated with driver expansion waves. Collectively, this Letter represents a major advancement for SRS in impulsive facilities, which had previously been limited to steady state regions or single-shot acquisition.

47 OTHER INSTRUMENTATION↗

On-chip optical levitation with a metalens in vacuum

Optical levitation of dielectric particles in vacuum is a powerful technique for precision measurements, testing fundamental physics, and quantum information science. Conventional optical tweezers require bulky optical components for trapping and detection. Here, we design and fabricate an ultrathin dielectric metalens with a high numerical aperture of 0.88 at 1064 nm in vacuum. It consists of 500-nm-thick silicon nano-antennas, which are compatible with an ultrahigh vacuum. We demonstrate optical levitation of nanoparticles in vacuum with a single metalens. The trapping frequency can be tuned by changing the laser power and polarization. We also transfer a levitated nanoparticle between two separated optical tweezers. Optical levitation with an ultrathin metalens in vacuum provides opportunities for a wide range of applications including on-chip sensing. Such metalenses will also be useful for trapping ultracold atoms and molecules.

Shen, Kunhong↗

Hearing carrier-envelope offset frequency and phase in air with a microphone

Attosecond science and frequency metrology rely on the precise measurement and control of the laser pulse waveform, a feat traditionally achieved using optoelectronic techniques. In this study, we conducted a laser-induced acoustic experiment in air ionized by carrier-envelope phase (CEP)-stabilized sub-4 fs pulses. Our results reveal that the acoustic signal exhibits CEP dependence in few-cycle pulses, primarily through amplitude modulation from laser-driven ionization. This optoacoustic phenomenon is, to the best of our knowledge, a novel phenomenon that enables not only the measurement of the carrier-envelope offset frequency but also the direct characterization of the waveform of optical pulses through a microphone. Our study highlights the potential of laser-induced acoustic waves for advancing ultrafast science.

Han, Meng [Kansas State University, Manhattan, KS ↗

Status and prospects of discovery of 0νββ decay with the CUORE detector

In this contribution we present the achievements of the CUORE experiment so far. It is the first tonne-scale bolometric detector and it is in stable data taking since 2018. We reached to collect about 1800 kg×yr of exposure of which more than 1 ton×year have been analysed. The CUORE detector is meant to search for the neutrinoless double β decay (0νββ) of the 130 Te isotope. This is a beyond Standard Model process which could establish the nature of the neutrino to be Dirac or a Majorana particle. It is an alternative mode of the two-neutrinos double β decay, a rare decay which have been precisely measured by CUORE in the 130 Te. We found no evidence of the 0νββ and we set a Bayesian lower limit of 2.2 ×10 25 yr on its half-life. The expertise achieved by CUORE set a milestone for any future bolometric detector, including CUPID, which is the planned next generation experiment searching for 0νββ with scintillating bolometers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AmeriFlux US-Bsg Burns Sagebrush

This is the AmeriFlux version of the carbon flux data for the site US-Bsg Burns Sagebrush. Site Description - The site was established in 2012 and is part of a NOAA observation network for high precision measurements of carbon dioxide concentrations. It is located about 60 km southwest of Burns, Oregon in the Oregon High Desert. The vegetation in this area is dominated by sagebrush. The sampling inlets are at the heights of 18.5, 28.5, and 38.5 m. Gas analysis is performed with a Picarro 2302 Cavity Ringdown Spectrometer and a Li-Cor 7200 enclosed path IRGA. The tower is also equipped with a set of meteorological instruments, including an HMP sensor, radiation sensors (incoming and diffuse PAR, Net radiometer), and a CSAT3 sonic anemometer. This site is also part of the PhenoCam network operated by Harvard University and the University of New Hampshire.

Still, Chris↗