Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Polarimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

PACE UV-VIS Polarimetric Remote Sensing of Atmosphere-Ocean Systems: Sensitivity to Variations in Brown Carbon

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission, scheduled for launch in 2024, will carry two instruments that measure ultraviolet (UV) radiance emerging from the top of the atmosphere: the Ocean Color Instrument (OCI) and the Spectro-Polarimeter for Planetary Exploration (SPEXone) instrument. OCI will provide single-view, hyperspectral radiometric data, whereas SPEXone will provide multi-angle, multispectral polarimetric data. Together, these instruments will be the most advanced in NASA’s history for the combined observation of ocean color and atmospheric aerosols in the UV, and they will therefore provide unprecedented research opportunities for the ocean color and atmospheric aerosol communities. In particular, UV observations are best suited to retrieve properties of Colored Dissolved Organic Matter (CDOM) in the ocean, and of Brown Carbon (BrC) aerosols in the atmosphere. However, both CDOM and BrC exhibit very similar absorption spectra in the UV and the visible (VIS) spectrum; hence, care must be taken in accurately modeling these spectra for analyses of OCI and SPEXone measurements. In this presentation, we summarize a simple but highly accurate three-parameter model for complex refractive index spectra of BrC in the UV and VIS. We apply this model to simulations of PACE-like total and polarized multiangle radiance in the UV, and demonstrate that the impact of BrC and CDOM variations can be similar in total radiance, but is easy to distinguish in polarized radiance.

PACE↗

Polarized proton beams in RHIC

The polarized beam for RHIC is produced in the optically-pumped polarized H{sup -} ion source and then accelerated in Linac to 200 MeV for strip-injection to Booster and further accelerated 24.3 GeV in AGS for injection in RHIC. In 2009 Run polarized protons was successfully accelerated to 250 GeV beam energy. The beam polarization of about 60% at 100 GeV beam energy and 36-42% at 250 GeV beam energy was measured with the H-jet and p-Carbon CNI polarimeters. The gluon contribution to the proton spin was studied in collisions of longitudinally polarized proton beams at 100 x 100 GeV. At 250 x 250 GeV an intermediate boson W production with the longitudinally polarized beams was studied for the first time.

43 PARTICLE ACCELERATORS↗

RHIC Polarized proton operation

The Relativistic Heavy Ion Collider (RHIC) operation as the polarized proton collider presents unique challenges since both luminosity(L) and spin polarization(P) are important. With longitudinally polarized beams at the experiments, the figure of merit is LP{sup 4}. A lot of upgrades and modifications have been made since last polarized proton operation. A 9 MHz rf system is installed to improve longitudinal match at injection and to increase luminosity. The beam dump was upgraded to increase bunch intensity. A vertical survey of RHIC was performed before the run to get better magnet alignment. The orbit control is also improved this year. Additional efforts are put in to improve source polarization and AGS polarization transfer efficiency. To preserve polarization on the ramp, a new working point is chosen such that the vertical tune is near a third order resonance. The overview of the changes and the operation results are presented in this paper. Siberian snakes are essential tools to preserve polarization when accelerating polarized beams to higher energy. At the same time, the higher order resonances still can cause polarization loss. As seen in RHIC, the betatron tune has to be carefully set and maintained on the ramp and during the store to avoid polarization loss. In addition, the orbit control is also critical to preserve polarization. The higher polarization during this run comes from several improvements over last run. First we have a much better orbit on the ramp. The orbit feedback brings down the vertical rms orbit error to 0.1mm, much better than the 0.5mm last run. With correct BPM offset and vertical realignment, this rms orbit error is indeed small. Second, the jump quads in the AGS improved input polarization for RHIC. Third, the vertical tune was pushed further away from 7/10 snake resonance. The tune feedback maintained the tune at the desired value through the ramp. To calibrate the analyzing power of RHIC polarimeters at any energy above injection, the polarized hydrogen jet target runs for every fill with both beams. Based on the known analyzing power, there is very little polarization loss between injection and 100 GeV. An alternative way is to measure the asymmetry at 100 GeV followed by ramping up to 250 GeV and back down to 100 GeV and then to measure the asymmetry again at 100 GeV. If the asymmetry after the down ramp is similar to the measurement before the up ramp, polarization was also preserved during the ramp to 250 GeV. The analyzing power at storage energy can then be extracted from the asymmetries measured at 100 GeV and 250 GeV. The tune and orbit feedbacks are essential for the down ramp to be possible. The polarized proton operation is still going on. We will push bunch intensity higher until reaching the beam-beam limit. The even higher intensity will have to wait for the electron lenses to compensate the beam-beam effect. To understand the details of spin dynamics in RHIC with two snakes, spin simulation with the real magnet fields have been developed recently. The study will provide guidance for possible polarization loss schemes. Further polarization gain will requires a polarized source upgrade; more careful setup jump quads in the AGS to get full benefit; and control emittance in the whole accelerator chain.

08 HYDROGEN↗

E166: Polarized Positrons & Polarimetry

A proof-of-principle experiment has been carried out in the Final Focus Test Beam (FFTB) at Stanford Linear Accelerator Center (SLAC) to demonstrate production of polarized positrons in a manner suitable for implementation at the International Linear Collider (ILC). A helical undulator of 2.54 mm period and 1 -m length produced circularly polarized photons with a first harmonic endpoint energy of 8 MeV when traversed by a 46.6 GeV electron beam. The polarized photons were converted to polarized positrons in a 0.2-radiation-length tungsten target. The polarization of these positrons was measured using a Compton transmission polarimeter to have peak value in excess of 80%.

43 PARTICLE ACCELERATORS↗

The proton form factor ratio results from Jefferson Lab

The ratio of the proton form factors, GE p/GMp, has been measured extensively, from Q2 of 0.5 GeV2 to 8.5 GeV2, at the Jefferson Laboratory, using the polarization transfer method. This ratio is extracted directly from the measured ratio of the transverse and longitudinal polarization components of the recoiling proton in elastic electron-proton scattering. The polarization transfer results are of unprecedented high precision and accuracy, due in large part to the small systematic uncertainties associated with the experimental technique. There is an approved experiment at JLab, GEP(5), to continue the ratio measurements to 12 GeV2. A dedicated experimental setup, the Super Bigbite Spectrometer (SBS), will be built for this purpose. It will be equipped with a focal plane polarimeter to measure the polarization of the recoil protons. The scattered electrons will be detected in an electromagnetic calorimeter. In this presentation, I will review the status of the proton elastic electromagnetic form factors and discuss a number of theoretical approaches to describe nucleon form factors.

43 PARTICLE ACCELERATORS↗

Electron Polarimetry

Electron polarimetry benefits from the ability to use processes with well- known analyzing powers, hence enabling high precision measurements. Several techniques are employed to measure electron beam polarization, including Mott, Møller, and Compton polarimetry. Each technique has particular advantages and disadvantages, depending on the application. This chapter will focus on the tech- niques used to measure electron beam polarization, with particular emphasis on the challenges and requirements for achieving high precision. The development of a conceptual design of a Compton polarimeter for the future Electron Ion Collider will also be discussed.

Gaskell, David↗

X-ray polarization signals from magnetars with axion-like-particles

Axion-like-particles (ALPs) produced in the core of a magnetar can convert to photons in the magnetosphere, giving rise to novel features in the X-ray spectrum. Since ALPs only mix with the parallel mode of the photon, the polarization of the soft and hard X-ray spectra is predicted to have an O-mode component, in addition to the mainly X-mode component given by most astrophysical models. The relative strength of the O-mode component depends on the intensity of ALPs produced in the core and the probability of conversion. We quantify our results by considering X-ray emission produced both by astrophysical processes and by ALP-photon conversion, in an uncorrelated fashion, and in different relative proportions, which we parametrize by the angle χ o . We then define a normalized astrophysics-subtracted Stokes parameter R which only acquires non-zero values in the presence of ALP-photon conversion. We find, remarkably, that the parameter R factorizes into a product of the ALP-to-photon conversion probability and cos(2χ o ) and display R, as well as the usual Stokes parameter Q, as a function of the photon energy and relative fractions of ALP and photon intensities. For benchmark points currently allowed by the CAST experiment, the O-mode prediction can be tested in future X-ray polarimeters and used either to constrain ALPs or find evidence for them.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tuning SPT-3G Transition-Edge-Sensor Electrical Properties with a Four-Layer Ti–Au–Ti–Au Thin-Film Stack

We have developed superconducting Ti transition-edge sensors with Au protection layers on the top and bottom for the South Pole Telescope’s third-generation receiver (a cosmic microwave background polarimeter, due to be upgraded this austral summer of 2017/2018). The base Au layer (deposited on a thin Ti glue layer) isolates the Ti from any substrate effects; the top Au layer protects the Ti from oxidation during processing and subsequent use of the sensors. We control the transition temperature and normal resistance of the sensors by varying the sensor width and the relative thicknesses of the Ti and Au layers. The transition temperature is roughly six times more sensitive to the thickness of the base Au layer than to that of the top Au layer. The normal resistance is inversely proportional to sensor width for any given film configuration. For widths greater than five micrometers, the critical temperature is independent of width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced ACTPol Low-Frequency Array: Readout and Characterization of Prototype 27 and 39 GHz Transition Edge Sensors

Advanced ACTPol (AdvACT) is a third-generation polarization upgrade to the Atacama Cosmology Telescope, designed to observe the cosmic microwave background (CMB). AdvACT expands on the 90 and 150 GHz transition edge sensor (TES) bolometer arrays of the ACT Polarimeter (ACTPol), adding both high-frequency (HF, 150/230 GHz) and low-frequency (LF, 27/39 GHz) multichroic arrays. The addition of the high- and low-frequency detectors allows for the characterization of synchrotron and spinning dust emission at the low frequencies and foreground emission from galactic dust and dusty star-forming galaxies at the high frequencies. The increased spectral coverage of AdvACT will enable a wide range of CMB science, such as improving constraints on dark energy, the sum of the neutrino masses, and the existence of primordial gravitational waves. The LF array will be the final AdvACT array, replacing one of the MF arrays for a single season. Prior to the fabrication of the final LF detector array, we designed and characterized prototype TES bolometers. Detector geometries in these prototypes are varied in order to inform and optimize the bolometer designs for the LF array, which requires significantly lower noise levels and saturation powers (as low as ~1 pW) than the higher-frequency detectors. Here we present results from tests of the first LF prototype TES detectors for AdvACT, including measurements of the saturation power, critical temperature, thermal conductance, and time constants. Finally, we also describe the modifications to the time-division SQUID readout architecture compared to the MF and HF arrays.

79 ASTRONOMY AND ASTROPHYSICS↗

Particle Response of Antenna-Coupled TES Arrays: Results from SPIDER and the Laboratory

Future mm-wave and sub-mm space missions will employ large arrays of multiplexed transition-edge-sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce ‘glitches’ in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers and multiplexed readout wiring. Here, we explore the susceptibility of modern TES arrays to the cosmic ray environment of space using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic microwave background polarimeter, and a laboratory exposure of SPIDER flight hardware to radioactive sources. We find manageable glitch rates and short glitch durations, leading to minimal effect on SPIDER analysis. We constrain energy propagation within the substrate through a study of multi-detector coincidences and give a preliminary look at pulse shapes in laboratory data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Keggin type inorganic-organic hybrid material containing Mn(II) monosubstituted phosphotungstate and S-(+)-sec-butyl amine: Synthesis and characterization

Graphical abstract: A new organic-inorganic hybrid material containing Keggin type manganese substituted phosphotungstate and S-(+)-sec-butyl amine was synthesized and systematically characterized. Highlights: Black-Right-Pointing-Pointer New hybrid material comprising Mn substituted phosphotungstate (PW{sub 11}Mn) and S-(+)-sec-butyl amine (SBA) was synthesized. Black-Right-Pointing-Pointer The spectral studies reveal the attachment of SBA to the PW{sub 11}Mn without any distortion of structure. Black-Right-Pointing-Pointer The synthesized material comprises chirality. Black-Right-Pointing-Pointer The synthesized hybrid material can be used as a heterogeneous catalyst for carrying out asymmetric synthesis. -- Abstract: A new inorganic-organic POM-based hybrid material comprising Keggin type mono manganese substituted phosphotungstate and enantiopure S-(+)-sec-butyl amine was synthesized in an aqueous media by simple ligand substitution method. The synthesized hybrid material was systematically characterized in solid as well as solution by various physicochemical techniques such as elemental analysis, TGA, UV-vis, FT-IR, ESR and multinuclear solution NMR ({sup 31}P, {sup 1}H, {sup 13}C). The presence of chirality in the synthesized material was confirmed by CD spectroscopy and polarimeter. The above study reveals the attachment of S-(+)-sec-butyl amine to Keggin type mono manganese substituted phosphotungstate through N {yields} Mn bond. It also indicates the retainment of Keggin unit and presence of chirality in the synthesized material. An attempt was made to use the synthesized material as a heterogeneous catalyst for carrying out aerobic asymmetric oxidation of styrene using molecular oxygen. The catalyst shows the potential of being used as a stable recyclable catalytic material after simple regeneration without significant loss in conversion.

36 MATERIALS SCIENCE↗

Comparison of modeled and measured performance of a GSO crystal as gamma detector

We have modeled, tested, and installed a large, cerium-activated Gd{sub 2}SiO{sub 5} crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up to 40 MeV, and photons from a continuous Compton backscattering spectrum up to 200 MeV. Our GEANT4 simulations, developed to determine the analyzing power of the Compton polarimeter in Hall A of Jefferson Lab, reproduce the measured spectra well.

Geant4 Gamma detection↗

Magnetic field devices for neutron spin transport and manipulation in precise neutron spin rotation measurements

The neutron spin is a critical degree of freedom for many precision measurements using low-energy neutrons. Fundamental symmetries and interactions can be studied using polarized neutrons. Parity-violation (PV) in the hadronic weak interaction and the search for exotic forces that depend on the relative spin and velocity, are two questions of fundamental physics that can be studied via the neutron spin rotations that arise from the interaction of polarized cold neutrons and unpolarized matter. The Neutron Spin Rotation (NSR) collaboration developed a neutron polarimeter, capable of determining neutron spin rotations of the order of 10 -7 rad per meter of traversed material. This paper describes two key components of the NSR apparatus, responsible for the transport and manipulation of the spin of the neutrons before and after the target region, which is surrounded by magnetic shielding and where residual magnetic fields need to be below 100 μG. These magnetic field devices, called input and output coils, provide the magnetic field for adiabatic transport of the neutron spin in the regions outside the magnetic shielding while producing a sharp nonadiabatic transition of the neutron spin when entering/exiting the low-magnetic-field region. In addition, the coils are self contained, forcing the return magnetic flux into a compact region of space to minimize fringe fields outside. The design of the input and output coils is based on the magnetic scalar potential method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization control at the microscopic and electronic structure observatory

The new Microscopic and Electronic Structure Observatory (MAESTRO) at the Advanced Light Source (ALS) in Berkeley provides X-rays of variable polarization, produced by an elliptically polarized undulator (EPU), for angle resolved photoemission (ARPES) and photoemission electron microscopy (PEEM) experiments. The interpretation of photoemission data, in particular of dichroism effects in ARPES, requires the precise knowledge of the exact polarization state. Numerical simulations show that the first harmonics of the EPU at MAESTRO provides soft X-rays of almost 100% on axis polarization. However, the higher harmonics as well as the downstream optical elements of the beamline, have a considerable impact on the polarization of the light delivered to the experimental end-station. Finally, employing a simple reflective polarimeter, the polarization is characterized for variable EPU and beamline settings and the overall degree of polarization in the MAESTRO end-stations is estimated to be on the order of 83%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The GlueX beamline and detector

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μs$. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. Here, we describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optically pumped polarized 3 He ++ ion source development for RHIC/EIC

The proposed polarized 3 He ++ acceleration in RHIC and the future Electron-Ion Collider will require about 2×10 11 ions in the source pulse. A new technique had been proposed for production of high intensity polarized 3 He ++ ion beams. It is based on ionization and accumulation of the 3 He gas (polarized by metastability-exchange optical pumping and in the 5T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel 3 He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized 3 He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3–5 T field has been developed. The 3 He polarization 80–85% (and sufficiently long ~30 min relaxation time) was obtained in the “open” cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and 3 He 4 He absolute nuclear polarimeter at 6 MeV 3 He ++ beam energy is also presented here in this work.

43 PARTICLE ACCELERATORS↗

Demonstration of sub-micron UCN position resolution using room-temperature CMOS sensor

High spatial resolution of ultracold neutron (UCN) measurement is of growing interest to UCN experiments such as UCN spectrometers, UCN polarimeters, quantum physics of UCNs, and quantum gravity. Here we utilize physics informed deep learning to enhance the experimental position resolution and to demonstrate sub-micron spatial resolutions for UCN position measurements obtained using a room-temperature CMOS sensor, extending our previous work that demonstrated a position uncertainty of 1.5 microns. We explore the use of the open-source software Allpix Squared to generate experiment-like synthetic hit images with ground-truth position labels. We use physics-informed deep learning by training a fully connected neural network (FCNN) to learn a mapping from input hit images to output hit position. The automated analysis for sub-micron position resolution in UCN detection combined with the fast data rates of current and next generation UCN sources will enable improved precision for future UCN research and applications.

10B nanometer thin film↗

γIn-beam angular distribution and linear polarization measurements with GRETINA using a simple energy-ordering approach

Angular distribution and linear polarization measurements are powerful tools for inferring the spins and parities of nuclear levels. In this work, the performance of the Gamma-Ray Energy Tracking In-beam Nuclear Array (GRETINA) as a Compton polarimeter was characterized in a fusion-evaporation reaction experiment using a simple energy-ordering approach for the interaction points assigned in the signal decomposition process. A variety of multipolarities and characters for γ-ray transitions in the reaction products 25 Mg, 25 Na, and 22 Ne, formed from fusion-evaporation of an 18 O beam on a 9 Be target, were examined. The experimental angular distributions and linear polarization asymmetries were consistent with predictions using the theoretical formalism accounting for the Lorentz boost.

Angular distribution↗