Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOOPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Loop Thermosyphon Enhanced Solar Collector

A two-phase loop thermosyphon solar collector was developed to transfer thermal energy efficiently and passively from a concentrated solar collector to a thermal desalination process. The two-phase flow in the loop thermosyphon is driven by a difference in gravitational pressure head between the liquid return line and the two-phase riser located between the evaporator and condenser. A numerical model incorporating mass, energy, and pressure drop balances was developed to predict system performance and use as a design tool. Three iterations of loop thermosyphon solar collectors were designed, fabricated, and tested to validate the numerical analysis and demonstrate system integration. Additionally, a novel solar receiver design was evaluated based on volumetric absorption of the concentrated sunlight by an optically absorptive two-phase working fluid. Life tests were performed to evaluate the working fluid thermal stability and resistance to ultraviolet degradation. A glass receiver tube and associated glass-to-metal junctions were developed. Finally, a full-scale loop thermosyphon was integrated with a parabolic trough solar collector and tested on-sun.

14 SOLAR ENERGY↗

High temperature mechanically pumped fluid loop for space applications : working fluid selection

Mechanically pumped single-phase fluid loops are well suited for transporting and rejecting large amounts of waste heat from spacecraft electronics and power supplies. While past implementations of these loops on spacecraft have used moderate operating temperatures (less than 6OoC), higher operating temperatures would allow equivalent heat loads to be rejected by smaller and less massive radiators. A high temperature (100 to 15OOC) mechanically pumped fluid loop is currently being investigated at the Jet Propulsion Laboratory for use on future Mars missions. This paper details the trade study used to select the high temperature working fluid for the system and the initial development testing of loop components.

thermal control↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

Crycooling↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heaters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

cryocooling↗

Thermal Vacuum Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and to verify its ability to cool large areas or components in the 3 degrees Kelvin temperature range. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully by simply applying power to both the capillary pump and the evaporator plate without pre-conditioning. It could adapt to a rapid heat load change and quickly reach a new steady state. Heat removal between 10 megawatts and 140 megawatts was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

Thermal Control Systems↗

Loop Heat Pipe Startup Behaviors

A loop heat pipe must start successfully before it can commence its service. The startup transient represents one of the most complex phenomena in the loop heat pipe operation. This paper discusses various aspects of loop heat pipe startup behaviors. Topics include the four startup scenarios, the initial fluid distribution between the evaporator and reservoir that determines the startup scenario, factors that affect the fluid distribution between the evaporator and reservoir, difficulties encountered during the low power startup, and methods to enhance the startup success. Also addressed are the pressure spike and pressure surge during the startup transient, and repeated cycles of loop startup and shutdown under certain conditions.

Thermal Control Systems↗

Thermal Vacuum Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

A loop heat pipe must start successfully before it can commence its service. The startup transient represents one of the most complex phenomena in the loop heat pipe operation. This paper discusses various aspects of loop heat pipe startup behaviors. Topics include the four startup scenarios, the initial fluid distribution between the evaporator and reservoir that determines the startup scenario, factors that affect the fluid distribution between the evaporator and reservoir, difficulties encountered during the low power startup, and methods to enhance the startup success. Also addressed are the pressure spike and pressure surge during the startup transient, and repeated cycles of loop startup and shutdown under certain conditions.

Thermal Control Systems↗

Keynote Address #2 - Scale-up of Chemical Looping Reactors: Practical Considerations and Design of Industrial Systems

Chemical looping technology is advancing toward large pilot-scale demonstrations. When scaling chemical looping reactors and chemical looping system integrated with steam generation issues of fuel distribution, thermal integration and modular operation must be considered in addition to sparing philosophy. The keynote addressed discusses a number of scaling issues unique to chemical looping systems.

20 FOSSIL-FUELED POWER PLANTS↗

Thermal and Mechanical Energy Performance Analysis of Closed-loop Systems in Hot-Dry-Rock and Hot-Wet-Rock Reservoirs

To understand the potential and limitations for recovering thermal and mechanical energy from closed-loop geothermal systems a collaborative study is underway that will investigate an array of system configurations, working fluids, geothermal reservoir characteristics, operational periods, and heat transfer enhancements. Closed-loop geothermal systems are distinguished from hydrothermal or enhanced geothermal systems (EGS) in that the working fluid only circulates through drilled boreholes. Principal objectives of this study are to determine upper limits for thermal and mechanical energy recovery and optimal operational and configuration parameters for each scenario. Teams of scientists and engineers are applying a suite of numerical simulation and analytical tools to model the heat recovery from closed-loop geothermal systems, and then optimizing operational and configuration parameters to maximize the thermal and mechanical energy recovery. Results from the suite of numerical simulators and analytical tools, such as outlet and inlet states and temperature profiles in the geothermal reservoir over time are intercompared to increase confidence in the analysis. This paper documents the study findings for closed-loop systems in hot-dry-rock and hot-wet-rock reservoirs, where water is the working fluid. The characteristics of the hot-dry-rock reservoir were based on the U.S. Department of Energy's Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site, near Milford Utah. Two objective functions are defined to optimize the operational and configuration parameters of the system, one each for the recovery of mechanical and thermal energy over the period of operation. For both objective functions, a surface plant thermal to mechanical energy conversion factor and an energy drilling cost is required. In keeping with the study objectives the surface plant conversion factor is determined from a second-law of thermodynamics analysis of a generic binary plant, and drilling costs are based on those from the Utah FORGE site and current national electrical costs.

closed-loop geothermal systems↗

Thermal and Mechanical Energy Performance Analysis of Closed-loop Systems in Hot-Dry-Rock and Hot-Wet-Rock Reservoirs

To understand the potential and limitations for recovering thermal and mechanical energy from closed-loop geothermal systems a collaborative study is underway that will investigate an array of system configurations, working fluids, geothermal reservoir characteristics, operational periods, and heat transfer enhancements. Closed-loop geothermal systems are distinguished from hydrothermal or enhanced geothermal systems (EGS) in that the working fluid only circulates through drilled boreholes. Principal objectives of this study are to determine upper limits for thermal and mechanical energy recovery and optimal operational and configuration parameters for each scenario. Teams of scientists and engineers are applying a suite of numerical simulation and analytical tools to model the heat recovery from closed-loop geothermal systems, and then optimizing operational and configuration parameters to maximize the thermal and mechanical energy recovery. Results from the suite of numerical simulators and analytical tools, such as outlet and inlet states and temperature profiles in the geothermal reservoir over time are intercompared to increase confidence in the analysis. This paper documents the study findings for closed-loop systems in hot-dry-rock and hot-wet-rock reservoirs, where water is the working fluid. The characteristics of the hot-dry-rock reservoir were based on the U.S. Department of Energy’s Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site, near Milford Utah. Two objective functions are defined to optimize the operational and configuration parameters of the system, one each for the recovery of mechanical and thermal energy over the period of operation. For both objective functions, a surface plant thermal to mechanical energy conversion factor and an energy drilling cost is required. In keeping with the study objectives the surface plant conversion factor is determined from a second-law of thermodynamics analysis of a generic binary plant, and drilling costs are based on those from the Utah FORGE site and current national electrical costs.

Closed-loop geothermal systems, hot-dry-rock, hot-↗

Chemical Looping of Manganese to Synthesize Ammonia at Atmospheric Pressure: Sodium as Promoter

Abstract Affordable synthetic ammonia (NH 3 ) enables the production of nearly half of the food we eat and is emerging as a renewable energy carrier. Sodium‐promoted chemical looping NH 3 synthesis at atmospheric pressure using manganese (Mn) is here demonstrated. The looping process may be advantageous when inexpensive renewable hydrogen from electrolysis is available. Avoiding the high pressure of the Haber‐Bosch process by chemical looping using earth‐abundant materials may reduce capital cost, facilitate intermittent operation, and allow operation in geographic areas where infrastructure is less sophisticated. At this early stage, the data suggest that 0.28 m 3 of a 50 % porosity solid Mn bed may suffice to produce 100 kg NH 3 per day by chemical looping, with abundant opportunities for improvement.

Aframehr, Wrya Mohammadi↗

Evolved Streptavidin Mutants Reveal Key Role of Loop Residue in High-affinity Binding

We have performed a detailed analysis of streptavidin variants with altered specificity towards desthiobiotin. In addition to changes in key residues which widen the ligand binding pocket and accommodate the more structurally flexible desthiobiotin, the data revealed the role of a key, non-active site mutation at the base of the flexible loop (S52G) which slows dissociation of this ligand by approximately sevenfold. Our data suggest that this mutation results in the loss of a stabilizing contact which keeps this loop open and accessible in the absence of ligand. When this mutation was introduced into the wild-type protein, destabilization of the opened loop conferred a {approx}10-fold decrease in both the on-rate and off-rate for the ligand biotin-4-fluoroscein. A similar effect was observed when this mutation was added to a monomeric form of this protein. Our results provide key insight into the role of the streptavidin flexible loop in ligand binding and maintaining high affinity interactions.

59 BASIC BIOLOGICAL SCIENCES↗

One-loop matching and running with covariant derivative expansion

We develop tools for performing effective field theory (EFT) calculations in a manifestly gauge-covariant fashion. We clarify how functional methods account for one-loop diagrams resulting from the exchange of both heavy and light fields, as some confusion has recently arisen in the literature. To efficiently evaluate functional traces containing these “mixed” one-loop terms, we develop a new covariant derivative expansion (CDE) technique that is capable of evaluating a much wider class of traces than previous methods. The technique is detailed in an appendix, so that it can be read independently from the rest of this work. We review the well-known matching procedure to one-loop order with functional methods. What we add to this story is showing how to isolate one-loop terms coming from diagrams involving only heavy propagators from diagrams with mixed heavy and light propagators. This is done using a non-local effective action, which physically connects to the notion of “integrating out” heavy fields. Lastly, we show how to use a CDE to do running analyses in EFTs, i.e. to obtain the anomalous dimension matrix. We demonstrate the methodologies by several explicit example calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-loop positivity of the planar $ \mathcal{N} $ = 4 SYM six-point amplitude

We study the six-point NMHV ratio function in planar $ \mathcal{N} $ = 4 SYM theory in the context of positive geometry. The Amplituhedron construction of the integrand for the amplitudes provides a kinematical region in which the integrand was observed to be positive. It is natural to conjecture that this property survives integration, i.e. that the final result for the ratio function is also positive in this region. Establishing such a result would imply that preserving positivity is a surprising property of the Minkowski contour of integration and it might indicate some deeper underlying structure. We find that the ratio function is positive everywhere we have tested it, including analytic results for special kinematical regions at one and two loops, as well as robust numerical evidence through five loops. There is also evidence for not just positivity, but monotonicity in a “radial” direction. We also investigate positivity of the MHV six-gluon amplitude. While the remainder function ceases to be positive at four loops, the BDS-like normalized MHV amplitude appears to be positive through five loops.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

All-loop cuts from the Amplituhedron

The definition of the amplituhedron in terms of sign flips involves both one-loop constraints and the “mutual positivity” constraint. To gain an understanding of the all-loop integrand of \( \mathcal{N}=4 \) sYM requires understanding the crucial role played by mutual positivity. This paper is an attempt towards developing a procedure to introduce the complexities of mutual positivity in a systematic and controlled manner. As the first step in this procedure, we trivialize these constraints and understand the geometry underlying the remaining constraints to all loops and multiplicities. We present a host of configurations which correspond to various faces of the amplituhedron. The results we derive are valid at all multiplicities and loop orders for the maximally helicity violating (MHV) configurations. These include detailed derivations for the results in. We conclude by indicating how one might move beyond trivial mutual positivity by presenting a series of configuration which re-introduce it bit by bit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A three-point form factor through five loops

We bootstrap the three-point form factor of the chiral part of the stress­tensor supermultiplet in planar $\mathcal{N}$ = 4 super-Yang-Mills theory, obtaining new results at three, four, and five loops. Our construction employs known conditions on the first, second, and final entries of the symbol, combined with new multiple-final-entry conditions, “extended-Steinmann-like” conditions, and near-collinear data from the recently-developed form factor operator product expansion. Our results are expected to give the maximally transcendental parts of the gg → Hg and H → ggg amplitudes in the heavy-top limit of QCD. At two loops, the extended-Steinmann-like space of functions we describe contains all transcendental functions required for four-point amplitudes with one massive and three massless external legs, and all massless internal lines, including processes such as gg → Hg and γ * → $q\overline{q}g$. We expect the extended-Steinmann-like space to contain these amplitudes at higher loops as well, although not to arbitrarily high loop order. We present evidence that the planar $\mathcal{N}$ = 4 three-point form factor can be placed in an even smaller space of functions, with no independent ζ values at weights two and three.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

One-loop free energy of tensionless type IIB string in AdS 5 ×S 5

Considering the zero ’t Hooft coupling limit of $\mathcal{N}$=4 super-Yang-Mills theory, the exact spectrum of all single-trace operators can be accessed in terms of the underlying so (2, 4) character. This makes it possible in turn to compute the one-loop free energy of the tensionless type IIB string theory in AdS 5 ×S 5 background, with help of the recently developed method of character integral representation of zeta function (CIRZ) . We calcu-late first the one-loop free energy of the string states in the ( p - 1)-th Regge trajectory and find the result to be p times the free energy of a single $\mathcal{N}$=4 Maxwell multiplet. The full one-loop free energy is hence proportional to the divergent series $\sum^{∞}_{p=2}p$. The divergence arises as a result of interrupting the regularization procedure in an intermediate stage. With a reorganization of states, we extract the finite part of free energy after summing over the Regge trajectories. This way gives us a finite result which is minus of the free energy of the $\mathcal{N}$=4 multiplet. Hence, this bulk one-loop result matches the -1 term in the N 2 - 1 factor of the boundary result.

1/N expansion↗

Loops in AdS from conformal field theory

We propose and demonstrate a new use for conformal field theory (CFT) crossing equations in the context of AdS/CFT: the computation of loop amplitudes in AdS, dual to non-planar correlators in holographic CFTs. Loops in AdS are largely unexplored, mostly due to technical difficulties in direct calculations. We revisit this problem, and the dual 1=N expansion of CFTs, in two independent ways. The first is to show how to explicitly solve the crossing equations to the first subleading order in 1=N 2 , given a leading order solution. This is done as a systematic expansion in inverse powers of the spin, to all orders. These expansions can be resummed, leading to the CFT data for nite values of the spin. Our second approach involves Mellin space. We show how the polar part of the four-point, loop-level Mellin amplitudes can be fully reconstructed from the leading-order data. The anomalous dimensions computed with both methods agree. In the case of $\phi$ 4 theory in AdS, our crossing solution reproduces a previous computation of the one-loop bubble diagram. We can go further, deriving the four-point scalar triangle diagram in AdS, which had never been computed. In the process, we show how to analytically derive anomalous dimensions from Mellin amplitudes with an in nite series of poles, and discuss applications to more complicated cases such as the N = 4 super-Yang-Mills theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗