Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Characterizations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps

This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.

Goekcen, Tahir↗

Know Your Enemy - Implementation of Bioremediation within a Suspected DNAPL Source Zone Following High-Resolution Site Characterization at Contractors Road Heavy Equipment Area, Kennedy Space Center, Florida

The National Aeronautics and Space Administration (NASA), Kennedy Space Center (KSC), has adopted high-resolution site characterization (HRSC) sampling techniques during baseline sampling prior to implementation of remedies to confirm and refine the conceptual site model (CSM). HRSC sampling was performed at Contractors Road Heavy Equipment Area (CRHE) prior to bioremediation implementation to verify the extent of the trichloroethene (TCE) dense non-aqueous phase liquid (DNAPL) source area (defined as the area with TCE concentrations above 1% solubility) and its daughter product dissolved plume that had been identified during previous HRSC events. The results of HRSC pre-bioremediation implementation sampling suggested that the TCE source area was larger than originally identified during initial site characterization activities, leading to a design refinement to improve electron donor distribution and increase the likelihood of achieving remedial objectives. Approach/Activities: HRSC was conducted from 2009 through 2014 to delineate the vertical and horizontal extent of chlorinated volatile organic compounds (CVOCs) in the groundwater. Approximately 2,340 samples were collected from 363 locations using direct push technology (DPT) groundwater sampling techniques. Samples were collected from up to 14 depth intervals at each location using a 4-foot sampling screen. This HRSC approach identified a narrow (approx. 5 to 30 feet wide), approximately 3,000 square foot TCE DNAPL source area (maximum detected TCE concentration of 160,000 micrograms per liter [micro-g/L] at DPT sampling location DPT0225). Prior to implementation of a bioremediation interim measure, HRSC baseline sampling was conducted using DPT groundwater sampling techniques. Concentrations of TCE were an order of magnitude lower than previous reported (12,000 micro-g/L maximum at DPT sampling location DPT0225) at locations sampled adjacent to previous sampling locations. To further evaluate the variability in concentrations observed additional sampling was conducted in 2016. The results identified higher concentrations than originally detected within the previously defined source area and the presence of source zone concentrations upgradient of the previously defined source area (maximum concentration observed 570,000 micro-g/L). The HRSC baseline sampling data allowed for a revision of the bioremediation design prior to implementation. Bioremediation was implemented within the eastern portion of the source area in November and December 2016 and quarterly performance monitoring was completed in March and June 2017. Reductions in CVOC concentrations from baseline were observed at all performance monitoring wells in the treatment area, and by June 2017, an approximate 95% CVOC mass reduction was observed based on monitoring well sampling results. Results/Lessons Learned: The results of this project suggest that, due to the complexity of DNAPL source zones, HRSC during pre-implementation baseline sampling in the TCE source zone was an essential strategy for verifying the treatment area and depth prior to remedy implementation. If the upgradient source zone mass was not identified prior to bioremediation implementation, the mass would have served as a long-term source for the dissolved plume.

Chrest, Anne↗

Amorphous Phase Characterization Through X-Ray Diffraction Profile Modeling: Implications for Amorphous Phases in Gale Crater Rocks and Soils

The CheMin X-ray diffraction instrument on the Mars Science Laboratory rover has analyzed 18 rock and soil samples in Gale crater. Diffraction data allow for the identification of major crystalline phases based on the positions and intensities of well-defined peaks and also provides information regarding amorphous and poorly-ordered materials based on the shape and positions of broad scattering humps. The combination of diffraction data, elemental chemistry from APXS (Alpha Particle X-ray Spectrometer) and evolved gas analyses (EGA) from SAM (Sample Analysis at Mars) help constrain possible amorphous materials present in each sample (e.g., glass, opal, iron oxides, sulfates) but are model dependent. We present a novel method to characterize amorphous material in diffraction data and, through this approach, aim to characterize the phases collectively producing the amorphous profiles in CheMin diffraction data. This method may be applied to any diffraction data from samples containing X-ray amorphous materials, not just CheMin datasets, but we re-strict our discussion to Martian-relevant amorphous phases and diffraction data measured by CheMin or CheMin-like instruments.

Achilles, C. N.↗

Improvements in the On-Orbit Response Versus Scan Angle Characterization of the Aqua MODIS Reflective Solar Bands

The Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) has been chosen by the Global Space-based Inter-Calibration System operational community as the reference sensor in cross-sensor calibration. A number of geostationary orbit and low-earth orbit sensors use the 0.64-μm band from Aqua MODIS as a calibration reference. After over 15 years on-orbit, the performance characteristics of the MODIS instrument have changed, with effects evident at short wavelengths. MODIS employs a reflectance-based calibration using the solar diffuser measurements with the monthly lunar observations facilitating a response versus scan angle characterization on-orbit. As the instrument continues to operate beyond its design lifetime of 6 years, the on-board calibrators alone are insufficient to accurately characterize the instrument's response at all scan angles. This results in a long-term reflectance drift, particularly observed in the 0.64- and 0.85-μm bands, while observing the temporally invariant desert sites. Long-term reflectance drifts of up to 2% and 3% are observed at the beginning of scan for the 0.64- and 0.85-μm bands, respectively. An approach using earth-view response to supplement the on-board calibrator measurements has been shown to overcome these inadequacies and is now implemented for the 0.64-, 0.85-, 0.46-, and 0.55-μm land bands of Aqua MODIS. This paper presents the details related to the algorithm implementation and an independent evaluation using the Dome Concordia site and deep-convective clouds. This approach has been reviewed, tested, and approved by the MODIS science team and has been implemented in the forward production of the MODIS L1B Collection 6 starting July 9, 2016. This enhanced approach has also been adopted in the MODIS L1B Collection 6.1 reprocess for the entire mission to facilitate an improved quality of downstream science products. The results with the enhanced approach reduce the reflectance drifts to within 0.5% for most cases.

Angal, Amit↗

Characterization and Analysis of Phoca Vitulina, Zalophus Californianus and Mirounga Angustirostris Vibrissae

Vibrissae of Phoca Vitulina (harbor seal) and Mirounga Angustirostris (elephant seal) possess undulations along their length. Harbor seal vibrissae have shown potential to reduce vortex induced vibrations and reduce drag compared to cylinders and ellipses. The exact geometry of the whiskers has not been well documented and the parameters that are responsible for the reduction in drag and vortex induced vibrations have not been characterized. Samples of six harbor seal vibrissae, six elephant seal vibrissae and six California sea lion (Zalophus californianus) vibrissae were collected from the Marine Mammal Center in California. The objectives of this study were to (1) Compare measurement techniques for digitizing and extracting parameters of the seal whiskers for the PeTaL (Periodic Table of Life) database. CT scanning, microscopy and 3D scanning techniques were compared. (2) Compare aerodynamic characteristics of a representative harbor seal whisker, elephant seal whisker, California sea lion whisker and ellipse at Re = 12000 and Re = 23000 based on major axis and free stream velocity. The data (in appendices) is available to compare CFD models or for further experimental validation, (3) Show close up images of whiskers and look for surface roughness effects. Variations in the seven parameters of the seal whisker were observed that may either be a feature of the vibration reduction mechanism or a result of natural variation. It is hypothesized that six parameters are sufficient to characterize seal whiskers based on analytic fitting. The drag coefficient of harbor seal whiskers examined in this study were found to be 25 percent lower than that of an ellipse with comparable major and minor axis lengths at Reynolds number of 12000. The dissipation length scale was found to be larger for seal whiskers. Potential applications of seal whisker morphology for aerospace are discussed. Roughness is not thought to play a factor in seal hydrodynamics.

Shyam, Vikram↗

Characterization of Freestream Disturbances in Conventional Hypersonic Wind Tunnels

While low disturbance ("quiet") hypersonic wind tunnels are believed to provide more reliable extrapolation of boundary layer transition behavior from ground to flight, the presently available quiet facilities are limited to Mach 6, moderate Reynolds numbers, low freestream enthalpy, and subscale models. As a result, only conventional ("noisy") wind tunnels can reproduce both Reynolds numbers and enthalpies of hypersonic flight configurations, and must therefore be used for flight vehicle test and evaluation involving high Mach number, high enthalpy, and larger models. This article outlines the recent progress and achievements in the characterization of tunnel noise that have resulted from the coordinated effort within the AVT-240 specialists group on hypersonic boundary layer transition prediction. New Direct Numerical Simulation (DNS) datasets elucidate the physics of noise generation inside the turbulent nozzle wall boundary layer, characterize the spatiotemporal structure of the freestream noise, and account for the propagation and transfer of the freestream disturbances to a pitot-mounted sensor. The new experimental measurements cover a range of conventional wind tunnels with different sizes and Mach numbers from 6 to 14 and extend the database of freestream fluctuations within the spectral range of boundary layer instability waves over commonly tested models. Prospects for applying the computational and measurement datasets for developing mechanism-based transition prediction models are discussed.

Duan, Lian↗

Characterization of CO Thermochemistry in Incident Shockwaves

Incident shock waves in pure CO have been characterized in the Electric Arc Shock Tube facility at NASA Ames Research Center. Spectrally and spatially resolved emission spectra characterize radiative signatures from CO in the VUV (Vacuum Ultra-Violet) and mid-infrared and atomic carbon and C2 in the visible. CO absorption of a single vibrational line is also measured with a tunable diode laser. The experimental data analyzed here are at a pressure of 0.25 Torr in the driven section and span a shock velocity range from 3.4-9.5 km/s. The emission and absorption signals are analyzed to extract temperature relaxation behind the shock which is used to derive the rate of CO dissociation. The emission spectra are compared to results using different kinetic parameters for CO dissociation and C2 dissociation and exchange. Different rates from the literature are found to match the data from 3.4-6.6 km/s and 6.6-9.5 km/s. Areas for improvement in CO and C2 radiation modeling are suggested on the basis of the analysis.

Entry↗

ATMS Radiometric Noise Characterization

The Advanced Technology Microwave Sounder (ATMS), on SNPP and NOAA-20, provides vertical atmospheric temperature and moisture profiles that are a key input to numerical weather prediction. Full characterization of radiometric noise is critical to error modeling, algorithm development and the potential development of performance requirements and product improvements. This paper presents estimates of white noise and low-frequency 1/f noise as derived from the Allan variance and scan-to-scan autocorrelations of data from the internal hot calibration. This approach allows direct comparison of on-orbit performance of the two units as well as comparison between ground calibration test data and on-orbit performance. The autocorrelation at multiple scan intervals is used as input to a theoretical model of the NET of inferred scene brightness temperature, when using weighted samples of calibration data over multiple scans. This will support selection of optimized calibration weighting functions for each channel, as well as providing further insight into the striping phenomenon. These measured autocorrelations are also compared to the autocorrelations derived from the 1/f spectra obtained both in special ground and on-orbit tests that characterize gain fluctuation. Channel cross-correlations are also presented, which can have a significant impact on effectiveness of direct assimilation performance.

instrument calibration↗

Characterization of CO Thermochemistry in Incident Shockwaves

Incident shock waves in pure CO have been characterized in the Electric Arc ShockTube facility at NASA Ames Research Center. Spectrally and spatially resolved emissionspectra characterize radiative signatures from CO in the VUV and mid-infrared and atomiccarbon and C2 in the visible. CO absorption of a single vibrational line is also measuredwith a tunable diode laser. The experimental data analyzed here are at a pressure of 0.25Torr in the driven section and span a shock velocity range from 3.4-9.5 km/s. The emissionand absorption signals are analyzed to extract temperature relaxation behind the shockwhich is used to derive the rate of CO dissociation. The emission spectra are compared toresults using different kinetic parameters for CO dissociation and C2 dissociation andexchange. Different rates from the literature are found to match the data from 3.4-6.6 km/sand 6.6-9.5 km/s. Areas for improvement in CO and C2 radiation modeling are suggested onthe basis of the analysis.

CO↗

Characterization and Analysis of Aerosol Particle Retention and Re-aerosolization from Hook-and-Loop Fasteners on the International Space Station

The extensive use of hook and loop fasteners aboard the International Space Station warrants careful examination of its contribution to indoor air pollution, as its fine fibers catch aerosol particles then re-aerosolize them upon being pulled apart, often within the breathing zone of astronauts. This problem is expanded by the lack of gravity because airborne particles larger than 1 micrometer do not settle. Instead these aerosols remain in the air until removed by filtration. Aerosol inhalation can have negative health effects, ranging from acute symptoms to long-term consequences, depending on particle sizes, mass and material composition. This study characterizes the size distribution, number concentration, and mass concentration of re-aerosolized debris generated by hook and loop fasteners taken from the stray light cover of the Microgravity Science Glovebox in the U.S. Laboratory of the ISS to understand the extent of its impact on air quality. Transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM), in conjunction with energy dispersive spectroscopy (EDS) were also used to characterize the morphology and composition of the particles.

Boyajian, Barbara↗

Characterization of Wildfire Emissions in California: Analysis of Airborne Measurements of Trace Gases from 2013 to 2016

Biomass burning, which includes wildfires, prescribed, and agricultural fires, is an important source of trace gases and particles, and can influence air quality on a local, regional, and global scale. Biomass burning emissions are an important source of several key trace gases including carbon dioxide (CO2) and methane (CH4). With the threat of wildfire events increasing due to changes in land use, increasing population, and climate change, the importance of characterizing wildfire emissions is vital. In this work we characterize trace gas emissions from 9 wildfire events in California between 2013 – 2016, in some cases with multiple measurements performed during different burn periods of a specific wildfire. During this period airborne measurements of CO2, CH4, water vapor (H2O), ozone (O3), and formaldehyde (HCHO) were made by the Alpha Jet Atmospheric eXperiment (AJAX). Located in the Bay Area of California, AJAX is a joint effort between NASA Ames Research Center and H211, LLC. AJAX makes in-situ airborne measurements of trace gases 2-4 times per month, resulting in 229 flights to date since 2011. Results presented include emission ratios (ER) of trace gases measured by AJAX during fire flights, and comparisons of ERs are made for each fire, which differ in time, location, burning intensity, and fuel type. We also use our airborne measurements to compare with photochemical grid model results to assess model approximations of plume transport and chemical evolution from select wildfires.

Parworth, Caroline L.↗

Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps

This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.

CFD↗

Method and System for Multi-Path Active Defect Detection, Localization and Characterization with Ultrasonic Guided Waves

A method and system of detecting, localizing, and characterizing a defect at one or more spatial points of interest on a structure. The method may include collecting first data in a first state using one or more transducers on the structure, collecting second data in a second state subsequent to the first state, computing a scattered impulse response based on the collected first data and the collected second data, comparing the scattered impulse response with an estimated scattered impulse response corresponding to the case when damage is present at one or more spatial points of interest on the structure, and combining the generated comparison results to detect, localize, and characterize a defect at the one or more spatial points of interest on the structure.

Hall, James Stroman↗

Developing a Novel Platform for Characterizing Thermoelectric Materials for Uncooled Detectors for Land Imaging Applications

Thermal land imaging (imaging at ~8-14 micron optical wavelength) is an essential tool for understanding and managing terrestrial freshwater resources. Current thermal imaging instruments employ low temperature detectors, which require cryocoolers. Consequently, cost-saving reductions in size, weight, and power can be achieved by employing uncooled detectors. One uncooled detector concept, which NASA is pursuing, is a thermopile detector with sub-micron thick doped-Si thermoelectric materials. In order to characterize the thermoelectric properties of the doped silicon, we designed and optimized a novel apparatus. This simple apparatus measures the Seebeck coefficient with thermally isolated stages and LABVIEW automation. We optimized thermal stability using PID tuning and optimized the thermal contact between the thin film samples and stages using electrically conductive springs. Utilizing our apparatus, we measured the Seebeck coefficient of 0.45 micron thick phosphorus-doped single crystal Si samples bonded to alumina substrates. Using these Seebeck coefficient measurements and four-wire electrical resistivity measurements, we determined the relationship between the thermoelectric figure of merit and dopant concentration. These characterization results for doped-Si will guide our thermopile detector design to provide an optimal and competitive detector alternative for future thermal imaging instruments.

Reid, Riley A.↗

AVCOAT Density Characterization for Orion Multi-Purpose Crew Vehicle

The Orion Multi-Purpose Crew Vehicle (MPCV) will transport four crew members to and from lunar-class orbital destinations. The first orbital Exploration Flight Test (EFT-1) is scheduled for December 2014 and will provide valuable data on several systems, including the heat shield. The heat shield material is AvcoatTM, a mid-density ablator. Specifically, the heat shield contains a fiberglass-phenolic honeycomb structure filled with an ablative epoxy novolac resin. Post-flight characterization of the EFT-1 thermal protection system will be conducted in order to study the material response and measure the char front of the material. Avcoat density profiling will be conducted to study three critical material zones: char, pyrolysis, and virgin states as a function of material depth. As part of a ground test campaign, Avcoat coupons are tested at the NASA Ames Research Center Arc Jet Complex. The test campaign is set forth to study material response based on environments, perform Avcoat material density characterization, and compare the char depths from the HEAT sensor and density profiling studies. These investigations will then be compared to flight data in order to improve upon TPS material response models.

AVCOAT↗

Towards Characterizing the Variability in the Loading Demands of an Unmanned Aerial Vehicle

This paper presents a computational methodology to characterize and quantify the variability in the power demands during the take-off of an unmanned aerial vehicle (UAV). A lithium-ion battery-based power system is used to power the unmanned aerial vehicle, and the capabilities of the unmanned aerial vehicle are driven by the amount of charge in this battery. In order to design the power system, it is necessary to analyze the power and charge requirements of the UAV. This paper focuses on the take-off segment, and aims to quantify the amount of charge that is required for this particular segment. Sparse data is available through different flight tests and this data is used to analyze the flight profile and the charge requirement during take-off. The amount of charge required for take-off depends on several factors that are not only variable but cannot be controlled in reality, and hence, the entire flight profile and the corresponding charge requirement are variable in nature. The information available through flight tests is converted into multi-dimensional sparse data and a new method is developed in this paper for variability characterization using multi-dimensional sparse data. This analysis is useful for prognostics and health management where it is necessary to anticipate future charge requirements in order to compute the end-of-discharge of the battery, and hence, the remaining useful life of the power system.

unmanned aerial vehicle↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗