Endogenizing Probabilistic Resource Adequacy Risks in Deterministic Capacity Expansion Models

In this work, we demonstrate how power system capacity expansion models can understate the stochastic effects of thermal outages when considering resource availabilities on an hourly expected value basis, yielding system designs with multiple orders of magnitude more shortfall risk than stated adequacy targets. We develop a novel approximation approach to efficiently endogenize awareness of this risk in a deterministic, linear capacity expansion framework. We compare this approach to exogenous tuning of an energy reserve margin, the leading alternative method to compensate for unmodeled probabilistic shortfall risk. Empirical results from a test system show that the new endogenous method cost-effectively meets all regional reliability targets with a single optimization solve, and produces a near-identical system design as the incumbent method without the need for repeated re-optimizations to find an appropriate reserve level. The endogenous method may also use iterative re-optimizations to further improve solution quality, although these incremental benefits were modest in the system studied.

capacity expansion modeling↗

Modeling of Electro-Magneto-Thermo-Mechanical Interactions in High Voltage Materials and Structures for Electric Propulsion

The growing interest in developing high-voltage-, high-power-capable electrical components for electric aircraft propulsion requires a more in-depth understanding of their electrical characteristics, critical material responses, and their synergistic influence on the overall performance of the system. A model that can accurately replicate the electrical, magnetic, thermal, and mechanical operating stresses and successfully predict the performance of the components will help engineers optimize the system design for a given airframe and powertrain.

electric propulsion↗

Simple Thermal Environment Model (STEM) User's Guide

This report presents a Simple Thermal Environment Model (STEM) for determining appropriate engineering design values to specify the thermal environment of Earth-orbiting satellites. The thermal environment of a satellite, consists of three components: (1) direct solar radiation, (2) Earth-atmosphere reflected shortwave radiation, as characterized by Earth's albedo, and (3) Earth-atmosphere-emitted outgoing longwave radiation (OLR). This report, together with a companion "guidelines" report provides methodology and guidelines for selecting "design points" for thermal environment parameters for satellites and spacecraft systems. The methods and models reported here are outgrowths of Earth Radiation Budget Experiment (ERBE) satellite data analysis and thermal environment specifications discussed by Anderson and Smith (1994). In large part, this report is intended to update (and supersede) those results.

Justus, C.G.↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Analytical Assessment of a Gross Leakage Event Within the International Space Station (ISS) Node 2 Internal Active Thermal Control System (IATCS)

Results of the International Space Station (ISS) Node 2 Internal Active Thermal Control System (IATCS) gross leakage analysis are presented for evaluating total leakage flowrates and volume discharge caused by a gross leakage event (i.e. open boundary condition). A Systems Improved Numerical Differencing Analyzer and Fluid Integrator (SINDA/FLUINT) thermal hydraulic mathematical model (THMM) representing the Node 2 IATCS was developed to simulate system performance under steady-state nominal conditions as well as the transient flow effects resulting from an open line exposed to ambient. The objective of the analysis was to determine the adequacy of the leak detection software in limiting the quantity of fluid lost during a gross leakage event to within an acceptable level.

Holt, James M.↗

Analytical Assessment of a Gross Leakage Event Within the International Space Station (ISS) Node 2 Internal Active Thermal Control System (IATCS)

Results of the International Space Station (ISS) Node 2 Internal Active Thermal Control System (IATCS) gross leakage analysis are presented for evaluating total leakage flow rates and volume discharge caused by a gross leakage event (i.e. open boundary condition). A Systems Improved Numerical Differencing Analyzer and Fluid Integrator (SINDA85/FLUINT) thermal hydraulic mathematical model (THMM) representing the Node 2 IATCS was developed to simulate system performance under steady-state nominal conditions as well as the transient flow effect resulting from an open line exposed to ambient. The objective of the analysis was to determine the adequacy of the leak detection software in limiting the quantity of fluid lost during a gross leakage event to within an acceptable level.

Holt, James M.↗

3D Material Response of the MSL Heatshield Using NuSil-Coated PICA

The Mars Science Laboratory (MSL) was protected during its atmospheric entry by an instrumented heatshield that used NASA's Phenolic Impregnated Carbon Ablator (PICA) material [1]. PICA is a lightweight carbon fiber/polymeric resin material that offers outstanding performance for protecting probes during planetary entry. Data from the Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of material response and atmospheric entry. MEDLI recorded, among other things, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP) [2]. A space-grade silicone-based coating commercially known as NuSil CV-1144-0 [3] was applied to the entire MSL heatshield, including the MEDLI plugs, to mitigate the spread of dust from PICA. Modeling the thermal response of PICA-NuSil (PICA-N) system is still an open challenge. Ground testing of PICA-N models exhibited surface temperature jumps of the order of 150 K due to oxide scale formation and sub-sequent NuSil burn-off. It is therefore critical to include a validated model for the material response of the coating in engineering codes. A test campaign has been conducted at the NASA’s Langley HyMETS [4] facility to screen the response of PICA-N and gather detailed data on its behavior [5]. A first model of PICA-N thermal response has been developed using the Hy-METS experiments [6]. The objective of this work is to analyze the material response of the latest PICA-N model compared to the engineering model used to simulate the entry of MSL. The environment and material response around the MSL aeroshell during Mars atmospheric entry is simulated using a collection of tools. The Direct Simulation Monte Carlo SPARTA code [7] is used in the rarefied regime, the Data Parallel Line Relaxation (DPLR) code [8] is used in the continuum regime and radiative heating conditions are provided by the Nonequilibrium air radiation (NEQAIR) code [9] to estimate the environmental conditions. The thermal response inside the material is computed using the Porous material Analysis Toolbox based on Open-FOAM (PATO) [10,11,12]. Thermodynamic and chemistry properties are estimated using the Mutation++ library [13]. The approach implemented in PATO as a first cut PICA-N thermal response model is outlined in Figure 1. While the recession is less than the coating thickness, the Surface mass and energy balance Boundary Condition (SBC) uses the NuSil B’ tables. Once the recession removes the coating, the usual PICA B’ tables are used for the SBC. The B’ tables are computed using an equilibrium solver implemented in Mutation++, given the temperature, pressure, blowing rate, composition of the pyrolysis and environment gases, and the condensed species at the surface. Preliminary results of the 3D material response of the MSL heat-shield at the peak heating (80 sec after Entry Interface) are shown in Figure 2. Current NASA’s mission to Mars, Mars 2020, used the spare heatshield of MSL for thermal protection during entry, descent, and landing. In preparation for Mars 2020 post-flight analysis, the PATO high-fidelity material response capability was benchmarked against flight data from MEDLI. This effort represents an important milestone toward the development of validated predictive capabilities for designing thermal protection systems for planetary probes. This bench-marking is awaiting the final release of the MEDLI-2 data.

Aerospace↗

Pilot Development Progress to Demonstrate Electric Thermal Energy Storage (ETES) Using Low-Cost Particles

The rapid growth of future energy demand increases the need to economically store electrical energy over durations up to several days in long-duration energy storage (LDES) applications. LDES can reduce the grid stress for improving the resilience of the grid. The integration of renewable power and storage has several significant and positive impacts including expanding the renewable energy portion of electricity generation, meeting peak-load demand, and coordinating supply and demand. Several energy storage approaches including mechanical, chemical and electrochemical methods are currently deployed or under development. However, LDES requirements pose unique challenges for scalability, energy capacity, and cost. Thermal energy storage (TES) has the ability to store a large capacity of energy with improved site flexibility compared to incumbent LDES technologies (i.e., pumped hydro) and has attracted significant interest. Our development in TES technology using solid particles as the storage medium has shown feasibility and potential in serving LDES purposes. Particle TES has various advantages over commercialized molten nitrate salt TES and has emerged as a promising storage technology originating from Generation 3 concentrating solar power (CSP) development. Stable, inexpensive silica sand produced in the Midwestern U.S. was identified as a suitable storage medium and has been validated through lab heating and cycling tests. We have successfully developed particle TES for bidirectional electric energy storage to broaden the applications for TES beyond CSP technologies and into standalone electric-thermal energy storage (ETES) systems. Key component designs and performance were verified with prototype testing and model simulations. The ETES system uses high-temperature, low-cost particle thermal energy storage coupled with a unique pressurized fluidized bed heat exchanger that supports a high-efficiency, air-Brayton combined power cycle. At times of low energy demand or high renewable production, an electric particle heater heats large quantities of solid particles to high temperatures in excess of 1100 degrees C. The particles are stored in internally insulated silos. At times of high electricity demand, the hot particles are gravity-fed through the heat exchanger where stored thermal energy is transferred to the power cycle working fluid to drive the gas turbine power generation system, thereby converting the thermal energy back into electricity for the grid. The cold particles leaving the heat exchanger are returned to the storage silos by a well-insulated particle conveyor. This ETES technology using particle TES can be sited anywhere and is predicted to be economic and efficient. Moreover, this ETES technology could be co-located with a retired coal or gas plant to leverage existing power generation and grid infrastructure. Our work has focused on the development of each of the key components (e.g., the electric particle heater, particle storage silos, and the particle-to-gas pressurized fluidized bed heat exchanger) through conceptual designs, prototype testing, and computational modeling. These developments demonstrate technological feasibility and are an important step towards the next phase of development of this promising LDES technology. This presentation will show the progress in developing a pilot demonstration of the ETES system on a commercially relevant scale.

25 ENERGY STORAGE↗

Modelling the Thermal History of Asteroid 4 Vesta

The asteroid 4 Vesta is widely thought to be the source of the HED (Howardite, Eucrite and Diogenite) meteorites, with this link supported by spectroscopic and dynamical studies. The availability of the HED meteorites for study and the new data being gained from the Dawn mission provides an excellent opportunity to investigate Vesta s history. In this study, modelling of Vesta has been undertaken to investigate its evolution from an unconsolidated chondritic body to a differentiated body with an iron core. In contrast to previous modelling, both heat and mass transfer are considered as coupled processes. This work draws on models of melt segregation in terrestrial environments to inform the evolution of Vesta into the differentiated body observed today. In order for a core to form in this body, a separation of the metallic iron from the silicates must take place. Temperatures in excess of the solidus temperatures for the Fe-FeS system and the silicates are therefore required. Thermal modelling has shown accretion before 2Myr leads to temperatures in excess of the silicate solidus.

Solano, James M.↗

High-Temperature Aquifer Thermal Energy Storage (HT-ATES) Projects in Germany and the Netherlands—Review and Lessons Learned

Aquifer thermal energy storage (ATES) is a concept that can help to address heating and cooling needs through the use of the subsurface as a seasonal thermal energy storage (STES) system. Over 2800 ATES systems have been deployed with storage temperatures typically below 25 °C and only a few with higher temperatures (>40 °C), which would increase the energy density and utility of the stored thermal fluids. Until now, only a few high-temperature aquifer thermal energy storage (HT-ATES) projects have been initiated and are still in operation. These HT-ATES projects have encountered a range of technical and non-technical challenges. This study reviews ten such projects: four in Germany and six in the Netherlands. The non-technical issues include public acceptance, a lack of regulatory framework for these systems, managing overlapping uses of the subsurface, managing changes with the providers and off-takers of thermal energy, and obtaining financing to implement these projects. Common technical issues include geological factors such as incomplete characterization of the subsurface and reservoir heterogeneity; geochemical issues such as mineral scaling, corrosion, and biofouling; lower than expected thermal recovery; and issues with system design and reliability. This review highlights benefits and challenges faced by HT-ATES projects with the goal to use the lessons learned to improve the siting, design, development, and operation of such systems. Recommendations include improved initial subsurface site characterization, use of coupled process models to optimize system design and predict system performance, cascaded uses of stored thermal energy to better utilize the stored heat, monitoring networks to provide feedback on system performance, and expanded system scale to allow for continued operation even when maintenance of some system components is required. Techno-economic modeling and risk analysis could be used to optimize such HT-ATES project design and identify key factors that will affect sustained economic viability. In addition, design flexibility is important for these systems to allow for changing conditions regarding the supply and demand of thermal energy. Adopting these findings should improve the performance and reduce the risks for future HT-ATES projects worldwide.

15 - GEOTHERMAL ENERGY↗

Solar Engineering of Thermal Processes, Photovoltaics and Wind, Fifth Edition

The updated Fifth Edition of Solar Engineering of Thermal Processes, Photovoltaics and Wind contains the fundamentals of solar energy and explains how we get energy from the sun. The authors - noted experts on the topic - provide an introduction to the technologies that harvest, store, and deliver solar energy, such as photovoltaics, solar heaters, and cells. The book also explores the applications of solar technologies and shows how they are applied in various sectors of the marketplace.

14 SOLAR ENERGY↗

Dynamic modelling and control strategy of a temperature-driven metal hydride cooling system for buildings

A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.

08 HYDROGEN↗

Lower limits for non-radiative recombination loss in organic donor/acceptor complexes

Understanding the factors controlling radiative and non-radiative transition rates for charge transfer states in organic systems is important for applications ranging from organic photovoltaics (OPV) to lasers and LEDs. Here we explore the role of charge-transfer (CT) energetics, lifetimes, and photovoltaic properties in the limit of very slow non-radiative rates by using a model donor/acceptor system with photoluminescence dominated by thermally activated delayed fluorescence (TADF). This blend exhibits an extremely high photoluminescence quantum efficiency (PLQY = ~22%) and comparatively long PL lifetime, while simultaneously yielding appreciable amounts of free charge generation (photocurrent external quantum efficiency EQE of 24%). In solar cells, this blend exhibits non-radiative voltage losses of only ~0.1 V, among the lowest reported for an organic system. Notably, we find that the non-radiative decay rate, k nr , is on the order of 10 5 s -1 , approximately 4–5 orders of magnitude slower than typical OPV blends, thereby confirming that high radiative efficiency and low non-radiative voltage losses are achievable by reducing k nr . Furthermore, despite the high radiative efficiency and already comparatively slow k nr , we find that k nr is nevertheless much faster than predicted by Marcus–Levich–Jortner two-state theory and we conclude that CT-local exciton (LE) hybridization is present. Our findings highlight that it is crucial to evaluate how radiative and non-radiative rates of the LE states individually influence the PLQY of charge-transfer states, rather than solely focusing on the PLQY of the LE. This conclusion will guide material selection in achieving low non-radiative voltage loss in organic solar cells and high luminescence efficiency in organic LEDs.

36 MATERIALS SCIENCE↗

Response of aerospace structures to reentry aerodynamic excitation

A bibliography on aerodynamic excitation and associated structural response is presented. Very little applicable data under actual reentry conditions was found, but many wind tunnel tests and some in-flight data were. Aerodynamic excitation and proposed space shuttle configurations and reentry trajectories were studied. Attached turbulent boundary layer, separated turbulent boundary layer, and base pressure fluctuations are the region of aerodynamic excitation most applicable to exterior panels of space shuttle-type vehicles; prediction techniques are presented for these environments. Methods for predicting the response of panel structures to acoustic excitation were investigated. A normal mode approach was developed for the low frequency response and a statistical energy approach was utilized for the high frequency response. A finite element model was made of a thermal protective system test panel. Computer programs were used to determine the natural frequencies and mode shapes of the panel and to calculate the response of the panel to a reverberant acoustic field. Power spectral densities of response displacement and acceleration are presented.

Carlin, D., Jr.↗

Study of a fail-safe abort system for an actively cooled hypersonic aircraft: Computer program documentation

The Fail-Safe Abort System TEMPerature Analysis Program, (FASTEMP), user's manual is presented. This program was used to analyze fail-safe abort systems for an actively cooled hypersonic aircraft. FASTEMP analyzes the steady state or transient temperature response of a thermal model defined in rectangular, cylindrical, conical and/or spherical coordinate system. FASTEMP provides the user with a large selection of subroutines for heat transfer calculations. The various modes of heat transfer available from these subroutines are: heat storage, conduction, radiation, heat addition or generation, convection, and fluid flow.

Haas, L. A., Sr.↗

Electroless-plating technique for fabricating thin-wall convective heat-transfer models

A technique for fabricating uniform thin-wall metallic heat-transfer models and which simulates a Shuttle thermal protection system tile is described. Two 6- by 6- by 2.5-in. tiles were fabricated to obtain local heat transfer rates. The fabrication process is not limited to any particular geometry and results in a seamless thin-wall heat-transfer model which uses a one-wire thermocouple to obtain local cold-wall heat-transfer rates. The tile is relatively fragile because of the brittle nature of the material and the structural weakness of the flat-sided configuration; however, a method was developed and used for repairing a cracked tile.

Avery, D. E.↗

Edge-defined film-fed growth of thin silicon sheets

Finite element analysis was used on two length scales to understand crystal growth of thin silicon sheets. Thermal-capillary models of entire ribbon growth systems were developed. Microscopic modeling of morphological structure of melt/solid interfaces beyond the point of linear instability was carried out. The application to silicon system is discussed.