At least 685 records · Page 38

316L Stainless Steel Wire Arc Additive Manufacturing and Characterization for Potential SNF Canister Production

In this paper, 316L stainless steel (316L SS) straight walls, curved walls, and vessels were printed by wire arc additive manufacturing (WAAM) using the 316L SS welding wire, to demonstrate the feasibility of spent nuclear fuel (SNF) canisters using this advanced manufacturing technique. Helium leak test with leak tight criteria of 1 × 10-7 ref-cc/s were performed on printed vessels with various wall thickness, and testing pressures were from 0.345 MPa (50 psi) to 1.724 MPa (250 psi). Printed wall microstructures were characterized using optical microscopy (OM) and scanning electron microscopy (SEM). Tensile specimens were machined out from printed walls along the length, height, and thickness directions, respectively, and tested at different temperature conditions, room temperature, 80 °C, 150 °C and 250 °C, respectively. Results showed t hat, all five WAAM-printed canisters with different thickness passed the helium leaktight criteria of radioactive materials containers by the ANSI N14.5; Dispersed micrometer-level size inclusions/voids were observed at printed wall cross sections, dendritic microstructures were found with grain size variation through the welding torch shifting direction, and very small amount of δ-ferrite and σ-phase were also observed in those cross sections; The printed walls were ductile, all tensile specimens broke with large plastic deformation/elongation and without brittle failure, and printed specimens yield strengths and tensile strengths under room temperature and 80 °C conditions are higher than minimum values of 316L SS for pressure vessels and for general applications at room temperature required by the ASTM standard, respectively.

Tang, Wei↗

An investigation of fracture toughness, fatigue-crack growth, sustained-load flaw growth, and impact properties of three pressure vessel steels

The elastic fracture toughness of the three steels is shown to not decrease significantly with decreasing temperature from room temperature to about 244 K (-20 F.). The elastic fracture toughness of the three steels increased with increasing specimen width and thickness. The fatigue-crack-growth data for all three steels fall into relatively narrow scatter bands on plots of rate against stress-intensity range. An equation is shown to predict the upper bounds of the scatter bands reasonably well. Charpy impact energies decreased with decreasing temperature in the nominal temperature range from room temperature to 244 K (-20 F). The nil-ductility temperatures of the steels are discussed.

Hudson, C. M.↗

A review of thermal physics and management inside lithium-ion batteries for high energy density and fast charging

Traditionally it has been assumed that battery thermal management systems should be designed to maintain the battery temperature around room temperature. That is not always true as lithium-ion battery (LIB) R&D is pivoting towards the development of high energy density and fast charging batteries. Therefore, it is necessary to have a comprehensive review of thermal considerations for LIBs targeted for high energy density and fast charging, i.e., the optimal thermal condition, thermal physics (heat transport and generation) inside the battery, and thermal management strategies. As the energy density and charge rate increases, the optimal battery temperature can shift to be higher than room temperature. In the first part of the review various sources of heat generation inside LIBs and various approaches to minimizing battery heat generation are summarized. The importance of heat of mixing due to ion diffusion during fast charging is also highlighted. To improve the temperature uniformity and avoid excessive internal temperature rise, heat transfer inside the battery needs to be enhanced, and reducing the thermal contact resistance between the electrodes and separator can significantly increase the effective thermal conductivity of batteries. In the second part of the review various challenges and latest developments related to thermal transport and properties of LIBs are discussed. Finally, a summary of latest advancement on smart control of internal temperature of LIBs is discussed as depending on the ambient temperature and the optimal temperature; the battery heat needs to be retained or dissipated to elevate or avoid temperature rise.

25 ENERGY STORAGE↗

Magnetoelectric Composites: Applications, Coupling Mechanisms, and Future Directions

Multiferroic (MF)-magnetoelectric (ME) composites, which integrate magnetic and ferroelectric materials, exhibit a higher operational temperature (above room temperature) and superior (several orders of magnitude) ME coupling when compared to single-phase multiferroic materials. Room temperature control and the switching of magnetic properties via an electric field and electrical properties by a magnetic field has motivated research towards the goal of realizing ultralow power and multifunctional nano (micro) electronic devices. Here, some of the leading applications for magnetoelectric composites are reviewed, and the mechanisms and nature of ME coupling in artificial composite systems are discussed. Ways to enhance the ME coupling and other physical properties are also demonstrated. Finally, emphasis is given to the important open questions and future directions in this field, where new breakthroughs could have a significant impact in transforming scientific discoveries to practical device applications, which can be well-controlled both magnetically and electrically.

36 MATERIALS SCIENCE↗

Select Electronic Parts Operation at Extreme Low Temperature

The purpose of the study presented in this paper is to extend the test period of a selected set of electronics parts at cryogenic condition to dwell period of about 24 hours to demonstrate extreme cold operational capability of these components. The parts tested are tantalum polymer, BX and P90 type ceramic capacitors, thick film resistors, analog multiplexers, a digital inverter, and a D-flip-flop. These parts were tested to assist identifying candidate components that can be used for development of a cold capable telemetry board. There are several past investigations that have shown that COTS (commercial-off-the-shelf) capacitors and resistors tested at cryogenic temperatures and frequencies up to 10MHz did not exhibit significant changes in capacitance and resistance values. Also, there are several test results for active parts. These past tests collected measurements during a temperature sweep from room temperature down to cryogenic temperature with very short dwell time at cryogenic temperature, and back to room temperature. This study extends the operational dwell time to at least 24 hours and returning to room temperature operation without significant degradation in performance, thus, demonstrating the potential for longer dwell time in actual operation in these extreme cold temperatures and a method for identifying the cold operability.

Ashtijou, Mohammad↗

Effect of subfreezing testing temperature on tensile mechanical behavior of fine-grained magnesium

Here, the effect of testing temperature on mechanical properties and deformation mechanisms was investigated by tensile testing of fine-grained magnesium samples under a range of temperatures (i.e. room temperature 20°C, subfreezing temperatures 0°C, -30°C, and - 60°C) and microstructural observations of both untested and tested samples using electron backscatter diffraction. The results suggest that mechanical properties and deformation mechanisms were significantly affected by lowering testing temperature. Strength increased linearly and ductility decreased linearly with the decrease of testing temperature. Although twinning is generally known to be athermal, this experimental study shows that tensile twinning is the dominating deformation mechanism at room temperature, and that twinning is negligible and dislocation operation is the primary deformation mechanism at 0°C, -30°C, and -60°C

36 MATERIALS SCIENCE↗

A Look Towards the Execution of the Low-Temperature TEX Experimental Campaign

To address the mounting need for below roomtemperature nuclear data validation, the Low-Temperature Thermal Epithermal eXperiments (LT-TEX) have been designed. Validation of low-temperature neutron cross sections is necessary to verify any operation at temperatures below room temperature which is typically observed in environments far from the equator. For example, a fissile material transportation truck may routinely observe ambient temperatures down to -40°C, which is the lower temperature bound of the normal conditions of transportation defined in the United States Title 10 Code of Federal Regulations §71.71c2. Additionally, sub-room temperature benchmarks can validate newly produced cross sections, that include novel thermal scattering laws, from North Carolina State University.

LT-TEX↗

Evaluation of the Effect of Surface Finish on High-Cycle Fatigue for SLM-IN718

A high-cycle fatigue (HCF) knockdown factor was estimated for Inconel 718, manufactured with the selective laser melt (SLM) process. This factor is the reduction at a common fatigue life from the maximum stress in fatigue for low-stress ground (LSG) specimens to the maximum stress of those left with the original surface condition. Various vendors provided specimens. To reduce the number of degrees-of-freedom, only one heat treat condition was evaluated. Testing temperatures included room temperature, 800F, 1000F, and 1200F. The two surface conditions were compared at constant lives, where data was available. The recommended knockdown factor of the as-built surface condition (average roughness of approximately 245 micro-inches/inch) versus low-stress ground condition (roughness <= 4 micro-inches/inch) is approximately 1/3 or 33%. This is to say that for the as-built surface condition, a maximum stress of 2/3 of the stress for LSG can be expected to produce the same life in the as built surface condition. As an alternative method, the surface finish was incorporated into a new parameter with the maximum stress. The new parameter was formulated to be similar to the fracture mechanics stress intensity factor, and it was named the pseudo stress intensity factor, Kp. Using Kp, the variance seemed acceptable across all sources, and the knockdown factor was estimated over the range of data identified by Kp where data occurred. A plot of the results suggests that the knockdown factor is a function of temperature, and that for low lives the knockdown is greater than the knockdown observed above about one million cycles, where it stabilizes. One data point at room temperature was clearly different, and the sparsity of data in the higher life region reduces the value of these results. The method does appear to provide useful results, and further characterization of the method is suggested.

Lambert, Dennis M.↗

Miniature, Lightweight, One-Time-Opening Valve

The figure depicts the main parts of a prototype miniature, lightweight, onetime- opening valve. Like some other miniature one-time-opening valves reported in previous issues of NASA Tech Briefs, this valve is opened by melting a material that blocks the flow path. This valve is designed to remain closed at some temperature between room temperature and cryogenic temperature until the time of opening. The prototype valve includes a 1/8-in. (3-mm) aluminum tube, one end of which is plugged with a solder comprising about 37 weight percent of lead and 63 weight percent of tin. The tube and the solder both have a coefficient of thermal expansion of 23 micron/m-K at room temperature. Before plugging, the interior surface of the plug end of the tube is cleaned with a commercial flux paste developed specifically for preparing aluminum for bonding with lead/tin solder. The solder is then melted into the cleaned end of the tube, forming the plug. In a test, the plugged tube was pressurized to 1,000 psi (6.9 MPa) with helium and leak-tested. It was then cooled to a temperature of 77 K (about 196 C) and again leak-tested at the same pressure. Finally, at a lower pressure, the plugged end of the tube was heated to about 200 C (the melting temperature of the solder is 183 C), causing the solder plug to be ejected (see figure). It has been estimated that in a subsequent version of the valve, the plug could be melted by electrical heating, using a nichrome wire having a mass of only 10 g.

Jones, Jack↗

Clarifying the definition of ‘transonic’ screw dislocations

We report a number of recent Molecular Dynamics (MD) simulations have demonstrated that screw dislocations in face centred cubic (fcc) metals can achieve stable steady state motion above the lowest shear wave speed (v shear ) which is parallel to their direction of motion (often referred to as transonic motion). This is in direct contrast to classical continuum analyses which predict a divergence in the elastic energy of the host material at a crystal geometry dependent ‘critical’ velocity v crit . Within this work, we first demonstrate through analytic analyses that the elastic energy of the host material diverges at a dislocation velocity (v crit ) which is greater than v shear , i.e. v crit >v shear . We argue that it is this latter derived velocity (v crit ) which separates ‘subsonic’ and ‘supersonic’ regimes of dislocation motion in the analytic solution. In addition to our analyses, we also present a comprehensive suite of MD simulation results of steady state screw dislocation motion for a range of stresses and several cubic metals at both cryogenic and room temperatures. At room temperature, both our independent MD simulations and the earlier works find stable screw dislocation motion only below our derived v crit . Nonetheless, in real-world polycrystalline materials v crit cannot be interpreted as a hard limit for subsonic dislocation motion. In fact, at very low temperatures our MD simulations of Cu at 10 Kelvin confirm a recent claim in the literature that true ‘supersonic’ screw dislocations with dislocation velocities v>v crit are possible at very low temperatures.

74 ATOMIC AND MOLECULAR PHYSICS↗

Investigation of magnetic and electrical transport properties of YMB 4 (M = Cr, Fe, and Co) compounds

We have studied the structural, magnetic, and electrical transport properties of the YMB 4 series of compounds (M= Cr, Fe, and Co). These materials exhibit high stability and possess notable refractory and thermoelectric properties. Furthermore, recent theoretical predictions suggest that some of these compounds may display quantum magnetism and dimer formation among the magnetic ions. We have synthesized almost single phase YMB 4 compounds in the orthorhombic crystal structure (space group Pbam) using arc-melting and annealing. The Rietveld analysis of the room-temperature X-ray diffraction patterns reveals a clear change in the lattice parameter c, which correlates with the atomic radii of Cr, Fe, and Co. The temperature variation of resistivity measured between 2 K and 300 K reveals a metallic electron transport in all three YMB 4 compounds. However, no abrupt change in resistivity due to structural or magnetic phase transitions is observed. Additionally, a weak positive magnetoresistance of 1%–2% has been measured at 2.5 K, the contribution from the metallic impurity cannot be ruled out. The carrier concentration, on the order of 10 21 cm −3 , has been determined using conventional Hall measurements. The thermomagnetic curves recorded between 2 K and 350 K reveal the non-magnetic behavior of all these compounds. However, a small magnetic moment from paramagnetic/ferromagnetic impurity phases is detected at low temperatures. Above room temperature, no magnetic transition associated with the breaking of a dimer is observed.

borides↗

Competing magnetic phases in Cr 3+𝛿 ⁢Te 4 are spatially segregated

Cr 1+𝑥⁢ Te 2 is a self-intercalated van der Waals system that is of current interest for its room-temperature room-temperature ferromagnetic (FM) phases and tunable topological properties. In bulk samples, the strain from the interstitial Cr ions leads to distinct structural phases for different ranges of 𝑥. Early neutron powder diffraction (NPD) measurements on the monoclinic phase Cr 3 ⁢Te 4 (𝑥=0.5) presented evidence for competing FM and antiferromagnetic (AFM) phases. Here we apply neutron diffraction to a single crystal of Cr 3+𝛿 ⁢Te 4 with 𝛿=−0.10 and discover that it consists of two distinct monoclinic phases, one with FM order below 𝑇 C ≈321 K and another that develops AFM order below 𝑇 N ≈86 K. In contrast, we find that a crystal with 𝛿=−0.26 exhibits only FM order below 𝑇 C ≈285 K. The single-crystal analysis is complemented by results obtained with NPD, x-ray powder diffraction, and transmission electron microscopy (TEM) measurements on the 𝛿=−0.10 composition. From observations of spontaneous magnetostriction of opposite sign at 𝑇 C and 𝑇 N , along with the TEM evidence for both monoclinic phases in a single thin ( ≈100 nm) grain, we conclude that the two phases must have a fine-grained ( ≲100 nm) intergrowth character, as might occur from high-temperature spinodal decomposition during the growth process. Calculations of the relaxed lattice structures for the FM and AFM phases with density functional theory provide a rationalization of the observed spontaneous magnetostrictions. Correlations between the magnitude and orientation of the magnetic moments with lattice parameter variation demonstrate that the magnetic orders are sensitive to strain, thus explaining why magnetic ordering temperatures and anisotropies can be different between bulk and thin-film samples, when the latter are subject to epitaxial strain. Our results point to the need to investigate the supposed coexistence FM and AFM phases reported elsewhere in the Cr 1+𝑥 ⁢Te 2 system, such as in the Cr 5 ⁢Te 8 phase (𝑥=0.25).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlation of processing and sintering variables with the strength and radiography of silicon nitride

A sintered Si3N4-SiO2-Y2O3 composition, NASA 6Y, was developed that reached four-point flexural average strength/standard deviation values of 857/36, 544/33, and 462/59 MPa at room temperature, 1200 and 1370 C respectively. These strengths represented improvements of 56, 38, and 21 percent over baseline properties at the three test temperatures. At room temperature the standard deviation was reduced by over a factor of three. These accomplishments were realized by the iterative utilization of conventional x-radiography to characterize structural (density) uniformity as affected by systematic changes in powder processing and sintering parameters. Accompanying the improvement in mechanical properties was a change in the type of flaw causing failure from a pore to a large columnar beta- Si3N4 grain typically 40 to 80 microns long, 10 to 30 microns wide, and with an aspect ratio of 5:1.

Sanders, W. A.↗

Correlation of processing and sintering variables with the strength and radiography of silicon nitride

A sintered Si3N4-SiO2-Y2O3 composition, NASA 6Y, was developed that reached four-point flexural average strength/standard deviation values of 857/36, 544/33, and 462/59 MPa at room temperature, 1200 and 1370 C, respectively. These strengths represented improvements of 56, 38, and 21 percent over baseline properties at the three test temperatures. At room temperature the standard deviation was reduced by over a factor of three. These accomplishments were realized by the iterative utilization of conventional X-radiography to characterize structural (density) uniformity as affected by systematic changes in powder processing and sintering parameters. Accompanying the improvement in mechanical properties was a change in the type of flaw causing failure from a pore to a large columnar beta-Si3N4 grain typically 40-80 micron long, 10-30 micron wide, and with an aspect ratio of 5:1.

Sanders, W. A.↗

Improved processing of Si3N4

A sintered Si3N4-SiO2-Y2O3 composition, NASA 6Y, was developed that reached four-point flexural average strength/standard deviation values of 857/36, 544/33, and 462/59 MPa at room temperature, 1200, and 1370 C, respectively. These strengths represented improvements of 56, 38, and 21 percent over baseline properties at the three test temperatures. At room temperature the standard deviation was reduced by more than a factor of three. These accomplishments were realized by the iterative utilization of conventional X-radiography to characterize structural (density) uniformity as affected by systematic changes in powder processing and sintering parameters. Accompanying the improvement in mechanical properties was a change in the type of flaw causing failure from a pore to a large columnar beta-Si3N4 grain typically 40 to 80 microns, 10 to 30 microns wide, and with an aspect ratio of 5:1.

Sanders, William A.↗

Progress Towards the Reality of Low-Temperature Critical Experiments with Low-Temperature TEX

Integral benchmarks for criticality safety do not exist below room temperature. Incredible support for below room temperature benchmarks is present across the international community. Validation of low-temperature neutron cross sections is necessary to verify any operation at temperatures below room temperature which is typically observed in environments far from the equator. For example, a fissile material transportation truck may routinely observe ambient temperatures down to -40°C, which is the lower temperature bound of the normal conditions of transportation defined in the United States Title 10 Code of Federal Regulations §71.71c2. Similarly, the IAEA, which contains 176 member states, has the same requirement for subcriticality for fissile material transportation. Additionally, sub-room temperature benchmarks can validate newly produced cross sections, that include novel thermal scattering laws, from North Carolina State University. A six-case experiment designed based off the TEX-HEU baseline experiments has been proposed utilizing a chilled vacuum chamber capable of cooling the HEU stack down to -50°C. The six proposed configurations span the entire neutron fission energy range and can be tested at intermediate temperatures between room temperature and -40°C. Of the six configurations, the fastest case utilizes nearly 135 kg of HEU. Understanding the system is required prior to critical experiment operations. In order to test the functionality of the system, testing with surrogate fuel materials has been conducted. The following discusses the design of the low temperature TEX (LT-TEX) experiment as well as the progress made via surrogate testing towards a reality in which low-temperature integral benchmarks exist in the International Criticality Safety Benchmark Evaluation Project (ICSBEP).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development and Acceptance Testing of the Dual Wheel Mechanism for the Tunable Filter Imager Cryogenic Instrument on the JWST

The James Webb Space Telescope (JWST) will carry four scientific instruments, one of which is the Tunable Filter Imager (TFI), which is an instrument within the Fine Guidance Sensor. The Dual Wheel (DW) mechanism is being designed, built and tested by COM DEV Ltd. under contract from the Canadian Space Agency. The DW mechanism includes a pupil wheel (PW) holding seven coronagraphic masks and two calibration elements and a filter wheel (FW) holding nine blocking filters. The DW mechanism must operate at both room temperature and at 35K. Successful operation at 35K comprises positioning each optical element with the required repeatability, for several thousand occasions over the five year mission. The paper discusses the results of testing geared motors and bearings at the cryogenic temperature. In particular bearing retainer design and PGM-HT material, the effects of temperature gradients across bearings and the problems associated with cooling mechanisms down to cryogenic temperatures. The results of additional bearing tests are described that were employed to investigate an abnormally high initial torque experienced at cryogenic temperatures. The findings of these tests, was that the bearing retainer and the ball/race system could be adversely affected by the large temperature change from room temperature to cryogenic temperature and also the temperature gradient across the bearing. The DW mechanism is now performing successfully at both room temperature and at cryogenic temperature. The life testing of the mechanism is expected to be completed in the first quarter of 2010.

Leckie, Martin↗

Effects of Microalloying on the Microstructures and Mechanical Properties of Directionally Solidified Ni-33(at.%)Al-31Cr-3Mo Eutectic Alloys Investigated

Despite nickel aluminide (NiAl) alloys' attractive combination of oxidation and thermophysical properties, their development as replacements for superalloy airfoils in gas turbine engines has been largely limited by difficulties in developing alloys with an optimum combination of elevated-temperature creep resistance and room-temperature fracture toughness. Alternatively, research has focused on developing directionally solidified NiAl-based in situ eutectic composites composed of NiAl and (Cr,Mo) phases in order to obtain a desirable combination of properties a systematic investigation was undertaken at the NASA Glenn Research Center to examine the effects of small additions of 11 alloying elements (Co, Cu, Fe, Hf, Mn, Nb, Re, Si, Ta, Ti, and Zr) in amounts varying from 0.25 to 1.0 at.% on the elevated-temperature strength and room-temperature fracture toughness of directionally solidified Ni-33Al-31Cr-3Mo eutectic alloy. The alloys were grown at 12.7 mm/hr, where the unalloyed eutectic base alloy exhibited a planar eutectic microstructure. The different microstructures that formed because of these fifth-element additions are included in the table. The additions of these elements even in small amounts resulted in the formation of cellular microstructures, and in some cases, dendrites and third phases were observed. Most of these elemental additions did not improve either the elevated-temperature strength or the room-temperature fracture toughness over that of the base alloy. However, small improvements in the compression strength were observed between 1200 and 1400 K when 0.5 at.% Hf and 0.25 at.% Ti were added to the base alloy. The results of this study suggest that the microalloying of Ni-33Al-31Cr-3Mo will not significantly improve either its elevatedtemperature strength or its room-temperature fracture toughness. Thus, any improvements in these properties must be acquired by changing the processing conditions.

Whittenberger, J. Daniel↗