Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Search for slow magnetic monopoles with the NOvA detector on the surface

We report a search for a magnetic monopole component of the cosmic-ray flux in a 95-day exposure of the NOvA experiment’s Far Detector, a 14 kt segmented liquid scintillator detector designed primarily to observe GeV-scale electron neutrinos. No events consistent with monopoles were observed, setting an upper limit on the flux of 2 × 10 -14 cm -2 s -1 sr -1 at 90% C.L. for monopole speed 6 × 10 -4 < β < 5 × 10 -3 and mass greater than 5 × 10 8 GeV. Because of NOvA’s small overburden of 3 meters-water equivalent, this constraint covers a previously unexplored low-mass region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of C P asymmetries in B 0 → K S 0 K S 0 K S 0 decays at Belle II

We report a measurement of decay-time-dependent charge-parity ( C P ) asymmetries in B 0 → K S 0 K S 0 K S 0 decays. We use 387 × 10 6 B B ¯ pairs collected at the ϒ ( 4 S ) resonance with the Belle II detector at the SuperKEKB asymmetric-energy electron-positron collider. We reconstruct 220 signal events and extract the C P -violating parameters S and C from a fit to the distribution of the decay-time difference between the two B mesons. The resulting confidence region is consistent with previous measurements in B 0 → K S 0 K S 0 K S 0 and B 0 → ( c c ¯ ) K 0 decays and with predictions based on the standard model. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Test of Light-Lepton Universality in the Rates of Inclusive Semileptonic B-Meson Decays at Belle II

We present the first measurement of the ratio of branching fractions of inclusive semileptonic B -meson decays, R ( X e / μ ) = B ( B → X e ν ) / B ( B → X μ ν ) , a precision test of electron-muon universality, using data corresponding to 189 fb - 1 from electron-positron collisions collected with the Belle II detector. In events where the partner B meson is fully reconstructed, we use fits to the lepton momentum spectra above 1.3 GeV / c to obtain R ( X e / μ ) = 1.007 ± 0.009 ( stat ) ± 0.019 ( syst ) , which is the most precise lepton-universality test of its kind and agrees with the standard-model expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transverse Single Spin Asymmetries of Heavy Flavor Electrons and Charged Pions in 200 GeV $p+p^{\uparrow}$ Collisions at Midrapidity

Transverse single spin asymmetries of particles produced in p+p^{\uparrow} p + p ↑ collisions provide insight on the partonic spin and momentum structure of hadrons; heavy flavor electrons provide access to initial state spin-momentum correlations of gluons in the proton, while charged pions provide access to initial and final state transverse spin effects. Charged particles are measured at midrapidity at PHENIX using the silicon vertex detector and central arm spectrometer, made of an electromagnetic calorimeter, a ring-imaging Cherenkov detector, and drift and pad chambers. Recent results for both electron and charged pion measurements from the 2015 running period will be presented.

Fitzgerald, Dillon↗

Development of Thin Gap GEM-µRWELL Hybrid Detectors at Jefferson Lab

Over the past few decades, Micro Pattern Gaseous Detector (MPGD) technologies have been increasingly adopted as tracking detector options in High Energy and Nuclear Physics experiments thanks to their good spatial resolution, high-rate capability, stability and more importantly their ability for large area coverage at a relatively low cost compared to the alternative. The thin gap GEM-µRWELL hybrid detector is the latest addition to the MPGD family, that was introduced to vastly improve the spatial resolution capability of gaseous trackers when deployed in the barrel region to cover large angular acceptance of the central tracker in a collider experiment. In this talk, I will re-introduce the concept and motivation for the development of thin gap GEM-µRWELL hybrid technology with an emphasis on the initial studies that establish the proof-of-concept of the technology. I will then discuss the more recent results from latest beam test campaign at Jefferson Lab in May 2025 to study detector efficiency performance with various gas mixtures. I will also briefly present the ongoing activities to develop large area thin gap GEM-µRWELL tracking detectors for the ePIC experiment of the future Electron Ion Collider as well as the exploration of the technology to provide large area tracking options to the muon system of experiments at a future Higgs Factory Collider such as the FCC-ee for example. Finally, I will conclude with some perspectives on new ideas under exploration to develop the next generation of thin gap MPGD technologies with enhanced timing and spatial resolution capabilities

Gnanvo, Kondo [Thomas Jefferson National Accelerat↗

Timing-Based Search for Magnetic Monopoles with the NOvA Detector on the Surface

We report a search for a magnetic monopole component of the cosmic-ray flux in a 2743-live-day exposure of the NOvA experiment's Far Detector, a 14 kt segmented liquid scintillator detector designed primarily to observe GeV-scale electron neutrinos. No events consistent with monopoles were observed, setting an upper limit on the flux of $8\times 10^{-16}~\mathrm{cm^{-2}s^{-1}sr^{-1}}$ at 90% C.L. for monopole speed $6\times 10^{-4} < β< 5\times 10^{-3}$ and mass greater than $10^{9}$ GeV. Because of NOvA's small overburden of 3 meters-water equivalent, this constraint covers a previously unexplored low-mass region.

Abubakar, S. [Erciyes U.]↗

Critical problems of energy frontier Muon Colliders: optics, magnets and radiation

This White Paper brings together our previous studies on a Muon Collider (MC) and presents a design concept of the 6 TeV MC optics, the superconducting (SC) magnets, and a preliminary analysis of the protection system to reduce magnet radiation loads as well as particle backgrounds in the detector. The SC magnets and detector protection considerations impose strict limitations on the lattice choice, hence the design of the collider optics, magnets and Machine Detector Interface (MDI) are closely intertwined. As a first approximation we use the Interaction Region (IR) design with beta-star=3 mm, whereas for the arcs we re-scale the arc cell design of the 3 TeV MC. Traditional cos-theta coil geometry and Nb3Sn superconductor were used to provide field maps for the analysis and optimization of the arc lattice and IR design, as well as for studies of beam dynamics and magnet protection against radiation. The stress management in the coil will be needed to avoid large degradation or even damage of the brittle SC coils. In the assumed IR designs, the dipoles close to the Interaction Point (IP) and tungsten masks in each IR (to protect magnets) help reducing background particle fluxes in the detector by a substantial factor. The tungsten nozzles in the 6 to 600 cm region from the IP, assisted by the detector solenoid field, trap most of the decay electrons created close to the IP as well as most of the incoherent electron-positron pairs generated in the IP. With sophisticated tungsten, iron, concrete and borated polyethylene shielding in the MDI region, the total reduction of background loads by more than three orders of magnitude can be achieved.

43 PARTICLE ACCELERATORS↗

Standard Candles for Supernova Neutrino Detection at DUNE

The Deep Underground Neutrino Experiment (DUNE) far detector is sensitive to $\mathcal{O}(10)$ MeV electron neutrinos through $ν_e$ charged-current reaction with argon. This capability is a unique window into the $ν_e$ component of a Galactic core-collapse supernova flux. Extracting the properties of the supernova spectrum is, however, limited by the poorly-known $ν_e$-Ar cross section. We propose a data-driven strategy that leverages $^8$B solar neutrinos and muon-decay-at-rest neutrinos as standard candles for this process. These calibration samples constrain both the low-energy and high-energy components of the cross section relevant for supernova detection. Our method reduces the reliance on nuclear models, which can bias the extraction of the spectral parameters by as much as 300$\%$.

Cheng, Ting [Fermilab]↗

Fast and bright scintillators for ultrafast materials dynamics using 4th generation synchrotron

We present recent advances in fast and bright scintillators for ultrafast X-ray phase contrast imaging of dynamic materials experiments at the upgraded Advanced Photon Source (APS-U), a fourth generation synchrotron. APS-U enables hard X-ray imaging at frame rates of at least 13 MHz (corresponding to 77 ns or shorter interframe intervals), creating a new need for scintillators with faster response and higher light output than lutetium yttrium oxyorthosilicate (LYSO). For indirect imaging and diffraction with ultrafast cameras, commercial lanthanum bromide (LaBr3) and cerium bromide (CeBr3) are promising candidates. These materials exhibit decay times approximately a factor of two shorter than LYSO (around 40 ns) and lutetium oxyorthosilicate (LSO), while maintaining comparable light yield per incident X-ray photon. However, their implementation at APS-U requires addressing several challenges, including material limitations due to hygroscopicity, efficient optical coupling to imaging systems, and high quantum efficiency for conversion of scintillation light, predominantly at wavelengths below 400 nm, into detectable electronic signals. We report results from material characterization, detector integration and packaging, and beamline experiments of materials with impact. In addition, emerging scintillator classes, including perovskites and high-entropy materials, are discussed as potential alternatives for next-generation ultrafast X-ray diagnostics.

Wang, Zhehui [Los Alamos] (ORCID:0000000178264063)↗

Directional Recoil Detection

Searches for dark matter–induced recoils have made impressive advances in the last few years. Yet the field is confronted by several outstanding problems. First, the inevitable background of solar neutrinos will soon inhibit the conclusive identification of many dark matter models. Second, and more fundamentally, current experiments have no practical way of confirming a detected signal's Galactic origin. The concept of directional detection addresses both of these issues while offering opportunities to study novel dark matter– and neutrino-related physics. The concept remains experimentally challenging, but gas time projection chambers are an increasingly attractive option and, when properly configured, would allow directional measurements of both nuclear and electron recoils. In this review, we reassess the required detector performance and survey relevant technologies. Fortuitously, the highly segmented detectors required to achieve good directionality also enable several fundamental and applied physics measurements. As a result, we comment on near-term challenges and how the field could be advanced.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

VitroJet: new features and case studies

Single-particle cryo-electron microscopy has become a widely adopted method in structural biology due to many recent technological advances in microscopes, detectors and image processing. Before being able to inspect a biological sample in an electron microscope, it needs to be deposited in a thin layer on a grid and rapidly frozen. The VitroJet was designed with this aim, as well as avoiding the delicate manual handling and transfer steps that occur during the conventional grid-preparation process. Since its creation, numerous technical developments have resulted in a device that is now widely utilized in multiple laboratories worldwide. It features plasma treatment, low-volume sample deposition through pin printing, optical ice-thickness measurement and cryofixation of pre-clipped Autogrids through jet vitrification. This paper presents recent technical improvements to the VitroJet and the benefits that it brings to the cryo-EM workflow. A wide variety of applications are shown: membrane proteins, nucleosomes, fatty-acid synthase, Tobacco mosaic virus, lipid nanoparticles, tick-borne encephalitis viruses and bacteriophages. These case studies illustrate the advancement of the VitroJet into an instrument that enables accurate control and reproducibility, demonstrating its suitability for time-efficient cryo-EM structure determination.

59 BASIC BIOLOGICAL SCIENCES↗

Cryogenic Instrumentation at ProtoDUNE

The cryogenic instrumentation of ProtoDUNE successfully operated during the first run of the experiment, providing a comprehensive monitoring of the cryostats, the cryogenics system and the detectors. It includes devices to measure the liquid argon level, the electron lifetime, the temperature of the liquid and gas argon, the pressure inside the cryostat and the contamination of the gas argon, as well as cameras to inspect the most critical detector elements. These systems and their performance are reviewed, and a few aspects of their future upgrade discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mapping valence electron distributions with multipole density formalism using 4D-STEM

Recent advancement in aberration correction and detector technology opened a door to various applications using 4D-STEM, which yields a diffraction pattern for each scanning position within a crystal unit-cell in scanning transmission electron microscopy (STEM) and generates incredible amounts of data in momentum space. Currently 4D-STEM analysis relies on the center-of-mass of the diffraction patterns in electric field and charge density mapping. It only derives the total projected charge density and is limited to phase objects, e.g. extremely thin samples. Here, we propose a new analytical method to accurately map aspherical valence electron distributions with atom-centered multipolar functions formalism using the whole 4D-STEM dataset. We demonstrate that, with the full dynamical calculations for various sample thicknesses, the method is sensitive not only to the miniscule charge transfer, but also to the atomic site symmetry and aspherical electron orbitals. The process of the refinement is much more robust and reliable than quantitative convergent beam electron diffraction.

4D-STEM↗

Topological background discrimination in the PandaX-III neutrinoless double beta decay experiment

The PandaX-III experiment plans to search for neutrinoless double beta decay (0ν ββ ) of 136 Xe in the China JinPing underground Laboratory (CJPL). The experiment will use a high pressure gaseous time projection chamber (TPC) to register both the energy and the electron track topology of an event. This article is devoted to demonstrate our particular detector setup capabilities for the identification of 0ν ββ and the consequent background reduction. As software tool we use REST, a framework developed for the reconstruction and simulation of TPC-based detector systems. We study the potential for background reduction by introducing appropriate parameters based on the properties of 0ν ββ events. We exploit for the first time not only the energy density of the electron track-ends, but also the electron scattering angles produced by an electron near the end of its trajectory. To implement this, we have added new algorithms for detector signal and track processing inside REST. Their assessment shows that background can be reduced by about 7 orders of magnitude while keeping 0ν ββ efficiency above 20% for the PandaX-III baseline readout scheme, a two-dimensional 3 mm pitch stripped readout. More generally, we use the potential of REST to handle 2D/3D data to assess the impact on signal-to-background significance at different detector granularities, and to validate the PandaX-III baseline choice. Finally, we demonstrate the additional potential to discriminate surface background events generated at the readout plane in the absence of to, by making use of event parameters related with the diffusion of electrons.

Majorana↗

Quaternary Semiconductor Cd1−xZnxTe1−ySey for High-Resolution, Room-Temperature Gamma-Ray Detection

The application of Cd0.9Zn0.1Te (CZT) single crystals, the primary choice for high-resolution, room-temperature compact gamma-ray detectors in the field of medical imaging and homeland security for the past three decades, is limited by the high cost of production and maintenance due to low detector grade crystal growth yield. The recent advent of its quaternary successor, Cd0.9Zn0.1Te1−ySey (CZTS), has exhibited remarkable crystal growth yield above 90% compared to that of ~33% for CZT. The inclusion of Se in appropriate stoichiometry in the CZT matrix is responsible for reducing the concentration of sub-grain boundary (SGB) networks which greatly enhances the compositional homogeneity and growth yield. SGB networks also host defect centers responsible for charge trapping, hence their reduced concentration ensures minimized charge trapping. Indeed, CZTS single crystals have shown remarkable improvement in electron charge transport properties and energy resolution over CZT detectors. However, our studies have found that the overall charge transport in CZTS is still limited by the hole trapping. In this article, we systematically review the advances in the CZTS growth techniques, its performance as room-temperature radiation detector, and the role of defects and their passivation studies needed to improve the performance of CZTS detectors further.

36 MATERIALS SCIENCE↗

Computational models of direct and indirect X‐ray breast imaging detectors for in silico trials

Abstract Background To facilitate in silico studies that investigate digital mammography (DM) and breast tomosynthesis (DBT), models replicating the variety in imaging performance of the DM and DBT systems, observed across manufacturers are needed. Purpose The main purpose of this work is to develop generic physics models for direct and indirect detector technology used in commercially available systems, with the goal of making them available open source to manufacturers to further tweak and develop the exact in silico replicas of their systems. Methods We recently reported on an in silico version of the SIEMENS Mammomat Inspiration DM/DBT system using an open‐source GPU‐accelerated Monte Carlo x‐ray imaging simulation code (MC‐GPU). We build on the previous version of the MC‐GPU codes to mimic the imaging performances of two other Food and Drug Administration (FDA)‐approved DM/DBT systems, such as Hologic Selenia Dimensions (HSD) and the General Electric Senographe Pristina (GSP) systems. In this work, we developed a hybrid technique to model the optical spread and signal crosstalk observed in the GSP and HSD systems. MC simulations are used to track each x‐ray photon till its first interaction within the x‐ray detector. On the other hand, the signal spread in the x‐ray detectors is modeled using previously developed analytical equations. This approach allows us to preserve the modeling accuracy offered by MC methods in the patient body, while speeding up secondary carrier transport (either electron–hole pairs or optical photons) using analytical equations in the detector. The analytical optical spread model for the indirect detector includes the depth‐dependent spread and collection of optical photons and relies on a pre‐computed set of point response functions that describe the optical spread as a function of depth. To understand the capabilities of the computational x‐ray detector models, we compared image quality metrics like modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), simulated with our models against measured data. Please note that the purpose of these comparisons with measured data would be to gauge if the model developed as part of this work could replicate commercially used direct and indirect technology in general and not to achieve perfect fits with measured data. Results We found that the simulated image quality metrics such as MTF, NNPS, and DQE were in reasonable agreement with experimental data. To demonstrate the imaging performance of the three DM/DBT systems, we integrated the detector models with the VICTRE pipeline and simulated DM images of a fatty breast model containing a spiculated mass and a calcium oxalate cluster. In general, we found that the images generated using the indirect model appeared more blurred with a different noise texture and contrast as compared to the systems with direct detectors. Conclusions We have presented computational models of three commercially available FDA‐approved DM/DBT systems, which implement both direct and indirect detector technology. The updated versions of the MC‐GPU codes that can be used to replicate three systems are available in open source format through GitHub.

Sengupta, Aunnasha↗