Best Practices Handbook for the Collection and Use of Solar Resource Data for Solar Energy Applications: Third Edition

As the world looks for low-carbon sources of energy, solar power stands out as the single most abundant energy resource on Earth. Harnessing this energy is the challenge for this century. Photovoltaics, solar heating and cooling, and concentrating solar power (CSP) are primary forms of energy applications using sunlight. These solar energy systems use different technologies, collect different fractions of the solar resource, and have different siting requirements and production capabilities. Reliable information about the solar resource is required for every solar energy application. This holds true for small installations on a rooftop as well as for large solar power plants; however, solar resource information is of particular interest for large installations because they require substantial investment, sometimes exceeding 1 billion dollars in construction costs. Before such a project is undertaken, the best possible information about the quality and reliability of the fuel source must be made available. That is, project developers need reliable data about the solar resource available at specific locations, including historic trends with seasonal, daily, hourly, and (preferably) subhourly variability to predict the daily and annual performance of a proposed power plant. Without these data, an accurate financial analysis is not possible. Additionally, with the deployment of large amounts of distributed photovoltaics, there is an urgent need to integrate this source of generation to ensure the reliability and stability of the grid. Forecasting generation from the various sources will allow for larger penetrations of these generation sources because utilities and system operators can then ensure stable grid operations. Developed by the foremost experts in the field who have come together under the umbrella of the International Energy Agency’s Solar Heating and Cooling Task 46, this handbook summarizes state-of-the-art information about all these topics.

14 SOLAR ENERGY↗

Best Practices Handbook for the Collection and Use of Solar Resource Data for Solar Energy Applications: Fourth Edition

As the world increasingly seeks low-carbon energy solutions, solar power emerges as the most abundant resource on our planet. However, the challenge of effectively harnessing this energy is crucial in the coming years. Solar energy applications such as photovoltaics, solar heating and cooling, and concentrating solar power use different technologies to capitalize on sunlight. Each system has unique capabilities and requirements, underscoring the need for reliable information about solar resources across diverse installations, from residential rooftops to large-scale power plants. This is especially important for substantial projects, often exceeding $1 billion in construction costs. Before embarking on such ventures, it is imperative to obtain accurate data concerning solar resource quality and reliability at specific sites. Developers require detailed historical information, including seasonal, daily, hourly, and, ideally, subhourly variability to effectively predict a power plant's annual performance. Without these vital data, financial analyses fall short. Moreover, with the growing adoption of distributed photovoltaics, integrating these generation sources becomes critical to maintaining grid reliability and stability. By accurately forecasting generation patterns, utilities and system operators can facilitate greater integration of solar energy, thus ensuring the operational stability of the grid. The complexity and importance of these issues have prompted the foremost experts in the field to collaborate under the auspices of the International Energy Agency's (IEA's) Photovoltaic Power Systems Programme (PVPS) Task 16 to publish this handbook, which summarizes state-of-the-art information about all these topics. The efforts focus on providing reliable data and insights that can help shape our investments in solar energy and drive a sustainable future.

14 SOLAR ENERGY↗

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

Life Cycle Analysis of Thermoelectric Power Generation in the United States

In this article, the basics of performing a life cycle analysis of thermoelectric power generation are discussed, with three examples of life cycle greenhouse gas (GHG) balances for thermoelectric power generation forms: coal, natural gas, and nuclear. The final section compares multiple electricity generation methods in the United States. Results are presented on the basis of 1 megawatt-hour (MWh) of electricity delivered to the end user. Environmental life cycle results for greenhouse gas (GHG) emissions are presented as carbon dioxide equivalents, based on 100-year global warming potentials (GWPs) established by the 6th Assessment Report from the Intergovernmental Panel on Climate Change in 2021, commonly referred to as AR6 GWP values (IPCC, 2021). Additional details on other environmental life cycle impacts from non-GHG emissions to air, emissions to water, solid waste generation, and land use are available on the Department of Energy, National Energy Technology Laboratory’s Life Cycle Analysis website: www.netl.doe.gov/LCA.

Cutshaw, Ashley↗

A hybrid architecture for volt-var control in active distribution grids

Modern active distribution grids are characterized by the increasing penetration of distributed energy resources (DERs). The proper coordination and scheduling of a large numbers of these small-scale and spatially distributed DERs is necessary, and warrants the use of novel distributed approaches. In this paper, we propose a hybrid volt-var control architecture for the distribution grid, which leverages existing centralized and local approaches to planning, decision making, and control, and augments it with distributed optimization and distributed control for DER management. First, we propose a convex model to describe the power physics of distribution grids of meshed topology and unbalanced structure, based on current injection and McCormick Envelopes. Second, we employ the distributed proximal atomic coordination (PAC) algorithm to coordinate DERs to provide voltage support. We implement volt-var optimization by optimally coordinating DERs including PV smart inverters and demand response. We present results using the IEEE-34 bus network, using real data from a distribution feeder in Hawaii, to model load and PV generation. Different levels of DER penetration and objective functions are simulated. Finally, our results show the need for the coordination of DERs to improve voltage profiles, even in networks with existing voltage control devices. Further, we show the need for flexible reactive power capabilities to achieve desired grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Passive cooling designs to improve heat resilience of homes in underserved and vulnerable communities

Disadvantaged communities face a growing threat to staying safe during heat waves, especially during coincident power outages. This study develops a methodology to evaluate the effectiveness of passive cooling measures (those that operate without power) to improve residential building heat resilience. Building performance is simulated for representative homes and on district scales in two disadvantaged communities in Fresno, California. Eleven passive measures are evaluated using four heat resilience metrics with and without grid power. Results show performance of the mitigation measures varies by building characteristics, surrounding environment, and power scenario. The two most effective measures were installing solar-control window films and adding roof insulation. For pre-1978 single-family homes, these two measures can reduce unmet degree-hours (UDH) indoors by 12% and 11% respectively without grid power, or 28% and 37% with grid power. Their respective UDH reductions at district scale typically range 8% — 20% and 4% — 12% without grid power, or 14% — 44% and 8% — 51% with grid power. Top floors have higher overheating risk than lower floors during extreme heat events with coincident power outages. Natural ventilation can help, reducing UDH by 21% — 26%. The methodology and findings from this study can help cities, communities, and utilities develop effective and targeted strategies to promote greater residential heat resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A new cyclic carbonate enables high power/ low temperature lithium-ion batteries

The modern lithium-ion battery (LIB) configuration was enabled by the "magic chemistry" between ethylene carbonate (EC) and graphitic carbon anode. Despite the constant changes of cathode chemistries with improved energy densities, EC-graphite combination remained static during the last three decades. While the interphase generated by EC protects the fragile graphitic structure, the intrinsic disadvantages of EC (high viscosity, high melting point, excessive interphase growth) lead to mediocre power density and poor performances of LIB at sub-zero temperatures, where lithium depositions form upon charging. Such performance compromises arise from the fundamental dilemma between requiring effective interphase protection and high impedance from excessive growth of interphase. In this work, we designed and synthesized a "double EC" molecule as electrolyte additive to resolve the above dilemma. Erythritol bis(carbonate) (EBC) possesses lower LUMO energy level than EC and hence tends to decompose prior to EC reduction, but its weak solvation toward Li + restricts the extent of its reduction, thus minimizing the interphase thickness and the corresponding impedances. Electrolytes containing EBC enables both the charging and discharging of ampere-size LIB pouch cells at sub-zero temperatures from 0 to -20°C, demonstrating that the key approach to improve low temperature performances lies in how to tailor interphasial chemistry rather than the bulk electrolyte composition.

25 ENERGY STORAGE↗

First considerations on the supporting structures of FCC-ee booster and collider in the arc regions

In 2022, the FCC Feasibility Study management mandated a working group to analyse the best configuration of the FCC-ee tunnel in the arc regions, in view of the construction of a mock-up of the arc half-cell. One of the main and most challenging goals of the study, named FCC-ee Arc Half-Cell Mock-up Project, was to perform a preliminary investigation on the principles of supporting the Short-Straight Sections and dipoles of the half-cells, both for the booster and for the collider machines. This is an important input needed for the choice of the best configuration of the relative placement of the booster with respect to the collider. The structural stiffness, mass and stability of the supporting structures must be optimized to minimize the vibrations transmitted/transferred to the magnetic system of the accelerators by elements such as pumps, water cooling system, beam thermomechanical stresses, powering elements, etc. To perform the study, tools such as CAD software, FEM and analytical techniques were employed. This paper summarizes the preliminary design concepts and the results of the simulations performed.

Accelerator Subsystems and Technologies↗

pyFLANK, a graph neural network based null distribution inference model for F ST outlier detection

Detecting genomic regions under selection is essential for understanding how populations adapt to different environments, yet it remains challenging due to the confounding effects of demographic history and linkage disequilibrium (LD). Fixation index (F ST ) is a widely used statistic to identify genomic regions under adaptation. However, identifying genes under selection by defining F ST outliers often remains challenging, owing to confounding effects of underlying demographic history. Traditional methods assume independence among loci and rely on simple demographic models, while newer models perform much better but are computationally expensive and not easily scalable. Here, we present pyFLANK, an open-source and automated Python implementation which detects F ST outliers using a null distribution inferred from quasi-independent loci. Our tool integrates three approaches to identify loci obeying a null distribution: graph neural network (GNN) inference, linkage disequilibrium (LD)-based inference, and user-defined input. Because pyFLANK uses GNN-based inference of quasi-independent loci, it yields a more accurate null model with less need for user parameter input. In simulation experiments, pyFLANK achieved lower false positive rates than current methods while maintaining comparable detection power, indicating that its refined null model better distinguishes true adaptive loci from background variation. The GNN-based model, in particular, detected additional loci associated with phenotypic variance that were not identified by existing methods. Assessments of simulation and real data from different species demonstrate that pyFLANK achieves lower false positive rates compared with other commonly used F ST outlier detectors, while maintaining comparable detection power and excellent computational performance, providing a robust and user-friendly tool for identifying loci under divergent selection. It extends existing F ST outlier frameworks by incorporating explicit LD-aware strategies for null model calibration. The method is intended as a practical and scalable complement to existing genome scan approaches.

FST↗

Robust Decentralized Secondary Control Scheme for Inverter-based Power Networks

Inverter-dominated microgrids are quickly becoming a key building block of future power systems. They rely on centralized controllers that can provide reliability and resiliency in extreme events. Nonetheless, communication failures due to cyber-physical attacks or natural disasters can make autonomous operation of islanded microgrids challenging. This paper examines a unified decentralized secondary control scheme that is robust to inverter clock synchronization errors and can be seamlessly applied to grid-following or grid-forming control architectures. The proposed scheme overcomes the well-known stability problem that arises from parallel operation of local integral controllers. Theoretical guarantees for stability are provided along with criteria to appropriately tune the secondary control gains to achieve good frequency regulation performance while ensuring fair power sharing. The efficacy of our approach is demonstrated through simulations on a 5-bus microgrid with four grid-forming inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated solution techniques for security constrained unit commitment problem

Apparatus and methods are disclosed for solving Mixed Integer Programming (MIP) problems, such as Security Constrained Unit Commitment (SCUC) problems used by power grid authorities to perform day-ahead market clearing. In certain examples, a plurality of threads of a software tool implementing a concurrent optimizer can be executed concurrently and sequentially to generate new solutions to a SCUC problem for an upcoming planning horizon. Data can be shared among the concurrently executing threads, such as intermediate/incumbent solutions and hints regarding the fixing of variables and constraints to reduce the size of the SCUC problem. In some examples, the threads are seeded with historical solutions from prior planning horizons. The software tool can select a best solution from the solutions generated by the threads, and determine dispatch instructions for a device coupled to the power grid for the upcoming planning horizon based at least in part on the selected solution.

Pan, Feng↗

Packaging a 650V/400A GaN Half-bridge Power Module with Ultra-low Parasitics for Electric Vehicle Drive Applications

This paper proposes a compact and efficient half-bridge power module with three 650 V / 150 A GaN dies in parallel. The power module incorporates a main power printed circuit board (PCB), an interface PCB, and a flex PCB to achieve low parasitics in both power loop and gate-side connection, resolving the issue of high parasitics typically encountered with wire bonding in high-current applications. Additionally, the interface PCB decouples the design constraints between the power loop and the gate loops. The proposed design is optimized with a vertical loop configuration to reduce power loop inductance through magnetic flux cancellation. Finite element analysis indicates that the power loop inductance is 0.58 nH at 100 MHz, while the maximum die junction temperature reaches 131 °C under an ambient temperature of 65 °C and a load current of 385 A. The proposed multi-piece PCB structure reduces the inductance of the drive circuit to minimize EMI and to mitigate false triggering. At the same time, it reduces impedance mismatches across different driver circuits, thereby achieving dynamic current sharing in multi-chip parallel configurations. Under simulation conditions of 400 V / 385 A, the current imbalance among chips was limited to 5 A. A 400 V / 385 A double-pulse test was conducted to experimentally validate the performance of the proposed power module.

30 DIRECT ENERGY CONVERSION↗

Riemannian Optimization Applied to AC Optimal Power Flow

The nonlinear, nonconvex AC optimal power flow problem is of growing importance as the nature of the power grid evolves. This problem can be difficult to solve for interior point methods. However, the advent of optimization algorithms over smooth Riemannian manifolds presents an alternative approach. The nonlinear, nonconvex constraints in the AC power flow problem form an embedded submanifold of Euclidean space. In this paper, the authors explore the performance of Riemannian optimization algorithms for the ACOPF problem where the optimization is performed directly on the AC power flow manifold. This is done by using the Julia programming language and the Julia packages PowerModels.jl and Manopt.jl.

AC optimal power flow↗

3D LiMn 2 O 4 nThin Film Deposited by ALD: A Road toward High-Capacity Electrode for 3D Li-Ion Microbatteries

Miniaturized electronics suffer from a lack of energy autonomy. In that context, the fabrication of lithium-ion solid-state microbatteries with high performance is mandatory for powering the next generation of portable electronic devices. Here, the fabrication of a thin film positive electrode for 3D Li-ion microbatteries made by the atomic layer deposition (ALD) method and in situ lithiation step is demonstrated. The 3D electrodes based on spinel LiMn 2 O 4 films operate at high working potential (4.1 V vs Li/Li + ) and are capable of delivering a remarkable surface capacity (approximate to 180 mu Ah cm -2 ) at low C-rate while maintaining more than 40 mu Ah cm -2 at C/2 (time constant = 2 h). Both the thickness of the electrode material and the 3D gain of the template are carefully tuned to maximize the electrode performance. Further, advanced characterization techniques such as transmission electron and X-ray transmission microscopies are proposed as perfect tools to study the conformality of the deposited films and the interfaces between each layer: no interdiffusion or segregation are observed. This work represents a major issue towards the fabrication of 3D-lithiated electrode by ALD-without any prelithiation step by electrochemical technique-making it an attractive solution for the fabrication of 3D Li-ion solid-state microbatteries with semiconductor processing methods.

3D Li-ion micro-batteries↗

Investigation of Various Transformer Topologies for HF Isolation Applications

High-frequency (HF) transformers are an essential part of many power electronic devices. The performance and behavior of HF transformers can greatly affect the efficiency and performance of all systems, particularly, from a parasitic parameter point of view. In this article, HF transformers' parasitic parameters, such as leakage inductances and parasitic capacitances, are analyzed using a novel analytical method, finite element method (FEM), and experimental measurements of different structures and winding arrangements. Also, the magnetic field, electric field, electric displacement field, and electric potential distribution within the transformers are simulated and analyzed. Four different HF transformers with E and U cores with different windings are designed and analyzed. Investigation outcomes help to classify structures according to the trade-off between leakage inductances and series parasitic capacitances. This information can later be used for the optimal selection and design of transformers as a function of their operating frequency for any power rating and voltage level. Moreover, 3-D FEM and experimental results validate the proposed methodology to be used for designing HF transformers in high-voltage/power applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The U.S. Agrivoltaic Shading Tool: A National-Scale Interface for Modeling Light and Shade Patterns in Ten Common Agrivoltaic Configurations

Agrivoltaic systems are dual-use configurations that co-locate agriculture and photovoltaic (PV) infrastructure and require careful design to balance crop performance and energy generation. A critical element of agrivoltaic design is the spatial and temporal distribution of irradiance and shade within and around PV arrays. To support research, planning, and stakeholder decision-making, we introduce the U.S. Agrivoltaic Shading Tool, a novel web-based application that delivers high-resolution irradiance and photosynthetically active radiation (PAR) modeling for ten standardized PV configurations across the conterminous United States. The tool leverages the National Laboratory of the Rockies (NLR) System Advisor Model (SAM) to perform detailed irradiance simulations, using meteorological data from the National Solar Radiation Database (NSRDB). Outputs include seasonal, monthly, weekly, and diurnal patterns of available sunlight, amount of shade, irradiance, and PAR at ground level within agrivoltaic system footprints. For a user's selected location, these results are visualized through interactive visualizations, heatmaps, and time-series plots, designed to be accessible to both technical and non-technical users. In addition to facilitating rapid spatial exploration of agrivoltaic light environments, the tool will offer seamless integration with the InSPIRE Agrivoltaics Design and Analysis Model (ADAM). This optional workflow will allow users to port selected site and configuration parameters into a more advanced modeling environment for further customization of structural layouts, crop-system compatibility, power generation, and technoeconomic performance. Finally, to promote open science, the entire dataset will be hosted and available for open access through the OpenEI platform. By standardizing and disseminating high-quality irradiance data and design tools, the U.S. Agrivoltaic Shading Tool supports a wide range of users, including researchers, landowners, energy developers, and policymakers, in evaluating the agronomic and energetic feasibility of agrivoltaic systems across the United States.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Resiliency-Driven Proactive Distribution System Reconfiguration With Synchrophasor Data

Measuring and enabling resiliency of electric distribution systems with increasing weather and cyber events are important. Some of the extreme events (e.g. Earthquakes, Hurricanes) and associated paths are predicted and monitored closely in advance and allow to take pre-event proactive control actions. The Distribution Phasor Measurement Units (D-PMUs) provide new opportunities and supporting such proactive actions. Here, a synchrophasor based resiliency driven pre-event reconfiguration can ensure minimizing impact of the expected event on the power distribution system and associated performance. However, the D-PMUs will also face challenges in terms of data quality similar to the transmission PMUs. The focus of this paper is to provide data mining approaches for anomaly detection in D-PMUs and proposing resiliency-driven pre-event reconfiguration with islanding as a proactive mechanisms to minimize the impact of adverse events on system using processed synchrophasors data. Results are validated for real industrial feeders and test cases with satisfactory response

controlled islanding↗

Power-Capping Metric Evaluation for Improving Energy Efficiency in HPC Applications

With high-performance computing systems now running at exascale, optimizing power-scaling management and resource utilization has become more critical than ever. This paper explores runtime power-capping optimizations that leverage integrated CPU-GPU power management on architectures like the NVIDIA GH200 superchip. We evaluate energy-performance metrics that account for simultaneous CPU and GPU power-capping effects by using two complementary approaches: speedup-energy-delay and a Euclidean distance-based multi-objective optimization method. By targeting a mostly compute-bound exascale science application, the Locally Self-Consistent Multiple Scattering (LSMS), we explore challenging scenarios to identify potential opportunities for energy savings in exascale applications, and we recognize that even modest reductions in energy consumption can have significant overall impacts. Our results highlight how GPU task-specific dynamic power-cap adjustments combined with integrated CPU-GPU power steering can improve the energy utilization of certain GPU tasks, thereby laying the groundwork for future adaptive optimization strategies.

Patrou, Maria [ORNL] (ORCID:0000000339754638)↗