Comparison of Thermal and Fast Neutron Computed Tomography of Complex Objects
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Recent research has focused on the development of surrogate models for radiation source localization in a simulated urban domain. We employ the Monte Carlo N-Particle (MCNP) code to provide high- delity simulations of radiation transport within an urban domain. The model is constructed to employ a source location (x, y, z) as input and return the estimated count rate for a set of speci ed detector locations. Because MCNP simulations are computationally expensive, we develop e cient and accurate surrogate models of the detector responses. We construct surrogate models using Gaussian processes (GP) and neural networks (NN) that we train and verify using the MCNP simulations. The trained surrogate models provide an e cient framework for Bayesian inference and experimental design. We employ Delayed Rejection Adaptive Metropolis (DRAM), a Markov Chain Monte Carlo (MCMC) algorithm, to infer the location and intensity of an unknown source. The DRAM results yield a posterior probability distribution for the source's location conditioned on the observed detector count rates. The posterior distribution exhibits regions of high and low probability within the simulated environment identifying potential source locations. In this manner, we can quantify the source location to within at least one of these regions of high probability in the considered cases. Employing these methods, we are able to reduce the space of potential source locations by at least 60%.
Replacing the existing aging analog instrumentation and control (I&C) systems with modern safety control and protection digital technology offers one of the foremost means of performance improvements and cost reductions for the existing nuclear power plants (NPPs). However, the qualification of digital I&C systems remains a challenge, especially considering the issue of software common-cause failures (CCFs), which are difficult to address. With the application and upgrades of advanced digital I&C systems, software CCFs have become a potential threat to plant safety because most redundant designs use similar digital platforms or software in the operating and application systems. With complex designs of multilayer redundancy to meet the single-failure criterion, digital I&C safety systems (e.g., engineered safety-features actuation system [ESFAS]) are of a particular concern in the U.S. Nuclear Regulatory Commission (NRC) licensing procedures. This paper applies a modularized approach to conduct redundancy-guided systems-theoretic hazard analysis for an advanced digital ESFAS with multilevel redundancy designs. Systematic methods and risk-informed tools are incorporated to address both hardware and software CCFs, which provide guidance to eliminate the triggers of potential single points of failure in the design of digital safety systems in advanced plant designs.
To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 × 10 34 cm –2 s –1 in the ultimate performance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionizing energy loss of up to $\Phi_{\text {eq}}$ = 3.5 × 10 16 cm –2 . Here this paper focuses on planar pixel sensor design and qualification up to a fluence of $\Phi_{\text {eq}}$ = 1.4 × 10 16 cm –2 . For the development of appropriate planar pixel sensors an R&D program was initiated, which includes $n^+ -p$ sensors on 150 mm (6”) wafers with an active thickness of 150 μm with pixel sizes of 100 × 25 μm 2 and 50 × 50 μm 2 manufactured by Hamamatsu. Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips. It demonstrates that multiple designs fulfill the requirements in terms of breakdown voltage, leakage current and efficiency. The single point resolution for 50 × 50 μm 2 pixels is measured as 4.0 μm for non-irradiated samples, and 6.3 μm after irradiation to $\Phi_{\text {eq}}$ = 7.2 × 10 15 cm –2 .
Identification of neutron sources is central to nuclear physics and its applications, from planetary science to nuclear security, yet direct source discrimination from measured neutron spectra remains fundamentally elusive. Here, we introduce a Bayesian protocol that directly infers source ensembles from measured neutron spectra by combining full-spectrum template matching with probabilistic evidence evaluation. Applying this protocol to recoil and time-of-flight spectroscopy, we recover single- and two-source configurations with strong statistical significance (beyond 4𝜎) at event counts as low as ∼10 3 . These results demonstrate that neutron spectral signatures can be leveraged for robust source identification, opening a new observational window for both fundamental research and operationally driven applications.
Quantum materials that combine magnetism with topological order are emerging as key platforms for next-generation spintronics and low-energy electronics. They enable the realization of emergent quantum phenomena, such as the quantum anomalous Hall effect and axion insulator states. The ferromagnetic insulator (FMI)/topological insulator (TI)/FMI sandwich structure of a single-septuple layer (1SL) MnBi 2 Te 4 /four-quintuple layer (4QL) Bi 2 Te 3 /1SL MnBi 2 Te 4 holds great potential to achieve such desirable quantum phenomena at an elevated temperature, owing to its large Dirac point band gap and high Curie temperature. Here, for this work, spin- and angle-resolved photoemission spectroscopy (spin-ARPES) is employed to directly verify that the band gap arises from broken time-reversal symmetry via proximity-driven magnetization. This study demonstrates direct control of the spin state via external magnetic fields and unambiguously confirms the exchange interaction as the gap-opening mechanism. The robust magnetic gap and controllable spin texture make this heterostructure a suitable candidate for spintronic applications and magnetic topological quantum phases.
This milestone highlights the successful upgrade and deployment of the Radiochemical Analysis of Gaseous Samples (RAGS) system, which delivers high-quality measurements (<20% uncertainty) of activated gaseous species from NIF implosions. These measurements are critical for supporting Stockpile Stewardship Program (SSP) relevant platforms, including LANL’s Double Shell and LLNL’s Pushered Single Shell campaigns. The RAGS diagnostic technique enables analysis of short-range mixing in implosions using high-Z shells, which are otherwise inaccessible to conventional x-ray diagnostic methods. By facilitating the investigation of high-Z material mixing into fusion burn, this system provides essential data for quantifying and interpreting results in high-energy density (HED) experiments. This report details the physics motivation, diagnostic fundamentals, planned and enacted upgrade work, and the quantification of uncertainty for the upgraded system.
Beryllium, as the material of choice for the ITER first wall, will be subject to high energy neutrons during the operation of the fusion device. Such irradiation will create displacement damage in the crystal lattice, which is known to influence hydrogen isotope retention, e.g. in iron and tungsten. Here in our study, we irradiated beryllium samples with high-energy oxygen ions up to various dpa levels (0.01 dpa, 0.1 dpa, and 1 dpa) and subsequently exposed the samples to deuterium plasma at 370 K and 573 K. The amount of retained deuterium was measured by thermal desorption spectroscopy and nuclear reaction analysis and was found to decrease by about 18% in the samples damaged up to 0.1 dpa compared to the undamaged ones. Further damaging up to 1 dpa did not show any additional effects on deuterium retention. Transmission electron microscopy was used to check for the existence of bubbles after plasma exposure.
This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryostat. The liquid argon is constantly purified and recirculated in a closed-loop cycle during operation. The specifications and assembly of the detector subsystems and an overview of their performance in a neutron beam are reported.
Abstract not provided.
Two implementations of dual energy X-ray absorptiometry were studied to identify materials using X-ray attenuation data taken with the Digital Radiography and Computed Tomography (DRCT) systems that were developed for the Recovered Chemical Materiel Directorate (RCMD). Maitrejean et al.’s approach utilizes eigen effects through Principal Component Analysis, while Osipov et al.’s approach proposed a physics-based method. Both approaches approximate mass attenuation coefficients of materials as a linear combination of basis functions (eigen effects) or physics-based equations. A set of coefficients {a 1 , a 2 , a 3 } or {B, D} were found by parameter optimization in EXCEL Solver. The identification parameters, {$\frac{a_{2}}{a_{1}}$, $\frac{a_{3}}{a_{1}}$} or estimated effective atomic number $\hat{Z}$ from {B, D}, were calculated to identify material of an aluminum 8 step wedge and a steel 8 step wedge in X-ray radiography images taken by a DRCT system. Maitrejean et al.’s approach was unable to provide reliable $\frac{a_{3}}{a_{1}}$ ratio values for identification of materials. Osipov et al.’s approach was found to be more robust in identify materials with a semi-empirical formula derived from test results in this study.
The Steel Equivalency Spreadsheet was created as a robust, user-friendly method for the following: 1. Determining if it is possible to image an object. 2. Reducing time needed when selecting equipment and preparing for field imaging activities. 3. Reducing the amount of equipment taken for field imaging activities. 4. Determining a starting point for exposure settings prior to imaging an object. 5. Reducing the amount of dose deposited to complete an imaging operation (in the spirit of As Low As Reasonably Achievable, ALARA). The spreadsheet was developed using various physical models to account for different phenomena. Future implementations aim to expand beyond the Digital Radiography and Computed Tomography Single Munition Scanner (DRCT SMS) in standard configuration to include high energy XRGs (Betatrons) and sub-MeV pulsed XRGs (XRS4). Alternative computational methods that compensate for incoherent scattering when calculating relative transmission are also being pursued. Ultimately the spreadsheet exceeded the developmental goal of having less than 10% average error when comparing calculations to real-world images.
Explore the source record for details and available documents.
Time-release diffusion measurements of cesium have been conducted over the temperature range 1073 K – 1973 K on oxidized and unoxidized IG-110 graphite. Four cesium concentrations were tested to investigate the concentration dependence of the diffusion coefficient. Two levels of oxidation were tested and compared to unoxidized concentration-matched sets to explore the effects of graphite oxidation. Here, the results demonstrate that cesium diffusion coefficient in unoxidized IG-110 graphite is independent of concentration within the range 34 – 163 µg Cs/g graphite . Above this, the effective cesium diffusion coefficient changes with concentration. The diffusion coefficient was increased by a factor of 2–12 in the oxidized set with 7.8% mass loss. These results can be used to aid predictive modeling of cesium diffusion in HTGR cores.
The Mu2e experiment at Fermilab searches for the neutrino-less conversion of a negative muon into an electron, with a distinctive signature of a mono-energetic electron with an energy of 104.967 MeV. The calorimeter is made of two disks of pure CsI crystals, each read out by two custom large-area UV-extended silicon photomultipliers (SiPMs). It plays a fundamental role in providing excellent particle identification capabilities and an online trigger filter while improving the track reconstruction, requiring better than 10% energy and 500 ps timing resolutions for 100 MeV electrons. In this article, we present the status of construction and the quality control (QC) performed on the produced crystals and photosensors, the development of the rad-hard electronics, and the most important results of the irradiation tests. Construction of the mechanics is also reported. Status and plans for the calorimeter assembly and its first commissioning are described.
Europium diffusion in graphite has been recognized to be of interest in high-temperature gas reactor safety analysis, particularly as an indicator of strontium diffusion. However, no measurements of europium diffusion coefficients have been reported in the literature. In this work, the effective diffusion coefficient of europium was measured using a time-release method. Natural europium was loaded into pre-milled unirradiated IG-110 graphite spheres using a pressurized acid digestion vessel. The time-release experiments were performed in the temperature range 1823 K – 1973 K using a SiC diffusion cell connected to an inductively-coupled plasma mass spectrometer (ICP-MS) via a He gas line. Finally, the results of this work are: D Eu, IG-110 = (1.5 x 10 -3 m 2 /s) exp $(\frac{-2.87\mathrm{x}10^{5} J/mol}{RT})$ This effective diffusion coefficient can be used to aid in predictive modelling of europium transport in HTGRs.
Scanning transmission x-ray microscopy was used to examine plutonium oxide particles formed by the corrosion of δ-phase plutonium alloy under high-humidity conditions. O K-edge spectra collected from eight distinct particles displayed significant spectral differences, revealing heterogeneity in oxidation states within a single sample batch. Here, this variation suggests complex chemical environments and formation histories, which are important considerations for nuclear forensic investigations. These findings highlight both the potential of synchrotron-based x-ray microscopy for nondestructive, high-resolution analysis of nuclear materials and the need for expanded reference datasets to improve the interpretation and forensic utility of such measurements.