Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dendrites”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

672 records · Page 38

A Comparison of Microstructure and Mechanical Performance of Inconel 718 Manufactured via L-PBF, LP-DED, and WAAM Technologies

The microstructure and mechanical properties of additively manufactured (AM) alloys can be significantly affected by variations in cooling rates, resulting from different process conditions across different additive manufacturing (AM) platforms. Therefore, it is crucial to understand the effect of manufacturing process on the microstructure and mechanical properties of AM Inconel 718. This study examines three AM processes: laser powder bed fusion, laser powder directed energy deposition, and wire arc additive manufacturing. Results show that fully heat treated laser powder bed fused (L-PBF) and wire arc additively manufactured (WAAM) Inconel 718 specimens exhibit higher strength compared to laser powder directed energy deposited (LP-DED) ones due to finer grain structure in L-PBF and retained dendritic microstructure in WAAM. The ductility in LP-DED Inconel 718 was slightly higher compared to WAAM and L-PBF due to relatively small carbide size, which causes stress concentration in a small material volume, leading to delayed fracture.

Additive manufacturing (AM)↗

Thin-Film Embedded Sensors for Battery Health Monitoring

Hybrid or all-electric aircraft are being developed as the next generation of aircraft to both allow new forms of aviation and decrease environmental impact. Since these types of aircraft are based on high-capacity battery technology, safe operation of these batteries becomes increasingly important. In particular, the potential for battery failure due to uncontrolled chemical reactions resulting in thermal runaway, catastrophic failure, and battery fires must be addressed in order for such battery technology to have the level of safety needed for standard aviation implementation. Efforts to ensure battery safety often involve engineering solutions that seek to contain rather than prevent such events by early detection. Such approaches increase the system weight and decrease the power per unit mass provided by the battery system. Existing methods for measuring battery parameters to determine the battery state-of-health are limited. These methods include electrical measurements of the cell current and/or voltage output as well as temperature measurements taken externally on the cell surface. Such external temperature measurements are limited in their ability to provide early warning of impending battery failure. In response, an effort to develop sensors operating internal to battery for health monitoring has been ongoing in the NASA Sensor-based Prognostics to Avoid Runaway Reactions & Catastrophic Ignition (SPARRCI) project. The basic approach associated with this sensor work is the deposition of thin film sensors on the battery separator located between the anode and cathode of the battery. These thin film sensors are then monitored to determine changes in battery parameters and health. Microfabrication techniques are employed to minimize the overall impact of the sensors on battery operation through the implementation of sensors with minimal size, weight, and power consumption. The thickness of the films, which are fabricated through physical vapor deposition (sputtering), are on the order of thousands of angstroms and can have minimal surface area. Thin film sensors for system health management have been implemented for a many decades on complex components for aerospace applications. However, the application of thin films of this type on a battery separator for internal battery monitoring applications has not previously been demonstrated to our knowledge. This paper describes the development of sensors for the internal battery monitoring through the use of thin film sensor technology. Thin metal films were successfully deposited on a battery separator polymer material with good adherence and electrical continuity. Multiple types of sensors have been deposited, as well as lead connections from the sensor to the edge of the separator material. The ability of these thin film sensors immersed in electrolyte to perform multiple types of battery parameter measurements has been demonstrated. For example, a multiparameter sensor system measured multiple properties simultaneously inside of a pouch cell over a wide temperature range. Further, real time measurement of interior temperature changes in a battery pouch cell with an integrated interior temperature sensor was demonstrated. These changes include detecting a fault in the battery (shorting) in situ with rapid response time (less than a minute) corresponding to a more limited response by a temperature sensor mounted externally. Other aspects of monitoring battery health were also explored, such as real-time measurement of simulated dendrite growth/metal deposition by sensor on separator material demonstrated. Future efforts will include improvements in the durability of the sensor structure to allow introduction of the approach into standard battery fabrication techniques. Overall, this work is a step forward in providing a method to prevent catastrophic battery failures and provide a foundation for safer, lighter, and higher energy batteries for the electric aircraft industry.

thin film battery health↗

Thermochemical Stability of Ca2Yb8(SiO4)6O2 Apatite in Presence of Molten Calcium-Magnesium-AluminoSilicate (CMAS)

Thermochemical stability of ytterbium silicon oxyapatite Ca 2 Yb 8 (SiO 4 ) 6 O 2 (CYbS) in the presence of molten calcium-magnesium aluminosilicate (CMAS) has been investigated at elevated temperatures. CYbS apatite powder was synthesized from the constituent oxides via solid state reaction method. Hot pressed apatite substrates were exposed to molten CMAS at 1200, 1300, and 1400 °C for 1, 10, and 50 h. Development of phases in the interaction region of the heat-treated specimens was monitored using scanning electron microscopy, transmission electron microscopy, high angle annular dark field imaging, selected area electron diffraction and energy dispersive X-ray spectroscopy. Monoclinic cyclosilicate Ca 3 Yb 2 (Si 3 O 9 ) 2 formed from interaction of CYbS apatite with CaO in the CMAS melt at the apatite-CMAS reaction front and continued to nucleate and grow within the residual CMAS in diffusion couples annealed for 1-50 h at 1200 °C and those heat treated at 1300 °C for 1 h. Residual CMAS was Ca-depleted when cyclosilicate was present. Dendritic wollastonite CaSiO 3 was observed within the residual CMAS in couples annealed at 1200 and 1300 °C. Ingress of molten CMAS, because of its exponential decrease in viscosity, occurred through open pores and along the grain boundaries of the apatite substrates without any detectable chemical reaction at 1300 and 1400 °C. Results of this study indicate that Ca 2 Yb 8 (SiO 4 ) 6 O 2 apatite has the potential to mitigate the CMAS corrosion up to about 1200 °C but not at higher temperatures.

X-ray diffraction↗

A Multi‐Probe Automated Classification of Ice Crystal Habits During the IMPACTS Campaign

Although all ice crystals are unique, many can be grouped together by shape or habit, with members of a habit class sharing similar representations of properties such as fall velocity and growth rate. A decision tree algorithm designed to be adaptable to any particle imaging probe, thus enabling the creation of habit size distributions over a size range larger than that of any probe on its own, is used to classify ice crystals imaged by three airborne cloud probes in mid-latitude winter cyclones during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Snowstorms (IMPACTS) field campaign. Crystals are sorted into seven habit classes based on their morphological properties: sphere, column/needle, plate, graupel, dendrite, aggregate, and irregular. Although adaptability was its primary goal, the algorithm was found to be moderately skillful for identifying idealized habit images. Quantitative tests of the algorithm’s adaptability displayed mixed results, as Two-Dimensional Stereo Probe (2DS) classifications showed moderate correlation with Particle Habit Imaging and Polar Scattering Probe (PHIPS) classifications, but only weak correlation with High Volume Precipitation Spectrometer (HVPS) classifications. The algorithm was applied to random sets of images from each probe in a case study of a mesoscale snow band sampled on 7 February 2020. In the case study, qualitative analysis of particle images revealed general agreement on classifications among the probes, supporting the algorithm’s applicability to multiple cloud probes. Most classifications appeared correct upon manual inspection, suggesting that in practical use, the algorithm is reasonably able to classify non-idealized images.

Julian Schima↗

Lithium Nucleation of Anode-Free Solid-State Batteries with a Dry Compressible Interlayer

Anode-free lithium batteries offer promising advantages, including increased energy density and the ability to address common mechanistic failures within the cell, thus increasing safety. One way that can make this possible is to control lithium nucleation. This could be achieved by reducing the overpotential required and implanting lithophilic nucleation sites in an anodic interlayer to aid in lithium ion transport and plating. The concept has been utilized in solid-state battery systems where electrolytes are solids with further improved safety and structural longevity. In this presentation, we discuss the use of a silver-holey graphene-based anodic interlayer that can be fabricated via direct dry compression without the use of solvent or binder. The addition of silver to the holey graphene matrix creates a route to lithium plating via a lower-energy intermediate. This idea is supported by the presence of a lithium-silver alloy that forms during the activation step. It is understood that the embedded silver acts as a nucleation site for lithium ions, thereby assisting in even plating. This control, combined with the added cushion of the holey graphene itself, can help reduce dendrite formation, ultimately increasing the safety and lifetime of the solid-state batteries.

Solid state batteries↗

Thermochemical Stability of Ca2Yb8(SiO4)6O2 Apatite in Presence of Molten Calcium-Magnesium-Aluminosilicate (CMAS)

Thermochemical stability of ytterbium silicon oxyapatite Ca 2 Yb 8 (SiO 4 ) 6 O 2 (CYbS) in the presence of molten calcium-magnesium aluminosilicate (CMAS) has been investigated at elevated temperatures for consideration as a thermal and environmental barrier coating (T/EBC) material. CYbS apatite powder was synthesized from the constituent oxides via a solid-state reaction method. Hot-pressed apatite substrates were exposed to molten CMAS at 1200, 1300, and 1400 °C for 1, 10, and 50 h. Development of phases in the interaction region of the heat-treated specimens was monitored using scanning electron microscopy, transmission electron microscopy, high-angle annular dark-field imaging, selected area electron diffraction, and energy dispersive x-ray spectroscopy. Monoclinic cyclosilicate Ca 3 Yb 2 (Si 3 O 9 ) 2 formed from interaction of CYbS apatite with CaO in the CMAS melt at the apatite-CMAS reaction front and continued to nucleate and grow within the residual CMAS in diffusion couples annealed for 1 to 50 h at 1200 °C as well as in those heat treated at 1300 °C for 1 h. Residual CMAS was depleted of Ca when cyclosilicate was present. Dendritic wollastonite (CaSiO3) was observed within the residual CMAS in couples annealed at 1200 and 1300 °C. Ingress of molten CMAS, because of its exponential decrease in viscosity, occurred through open pores and along the grain boundaries of the apatite substrates without any detectable chemical reaction at 1300 and 1400 °C. Results of this study indicate that Ca 2 Yb 8 (SiO 4 ) 6 O 2 apatite has the potential to mitigate the CMAS corrosion up to about 1200 °C but not at higher temperatures.

Narottam P Bansal↗