Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ablatives Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Production-Ready CsPbBr3 Module Fabrication

The purpose of this SBIR was to work on evaluation, development, and testing of CsPbBr3 semiconductors for use in commercial gamma-ray detection. The overarching goal was to demonstrate the capability to fabricate functional detectors through resources available to H3D, Inc in pursuit of an alternative to CdZnTe for room-temperature semiconductor detectors. Throughout the project, CdZnTe crystals from Redlen were used as a control group to demonstrate whether the fabrication processes could produce reasonable results. The CdZnTe crystals were diced into roughly 6 mm x 6 mm x 4.5 mm pieces and electrodes were evaporated onto planar faces. In one case, pixels were patterned through a laser ablation method; in the other, a rudimentary pixel shadow-mask was fabricated, and the pixels were generated in the evaporation process. A 16 mm x 16 mm x 14 mm CsPbBr3 crystal was diced into four smaller crystals. These CsPbBr3 had electrodes applied in a similar way to the CdZnTe samples with a rudimentary mask used for pixels on the cathode. Tested CdZnTe pieces were found to generally function with reasonable, low-energy performance. CsPbBr3 crystals were found to be non-functional under forward bias with a large dark-current. A separate attempt, using reverse bias in a non-H3D, Inc test system, observed a dark current similar to previous observations, and some active pixels but no waveforms were observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shock-tube studies of radiative base heating of Jovian probe

A 6.4-cm-diameter scale model of the Jovian entry vehicle is tested in an electric-arc-driven shock tube and a 5-cm-diameter sphere model is tested in a combustion-driven shock tube and in an electric-arc-driven shock tunnel. The radiative heat-transfer rate and pressure on the front and the base regions are measured in the absence of ablation with sensors imbedded in the models in a stream consisting of 10% hydrogen in a bath of either neon or argon. The measured radiative heat-transfer rates and pressures range to about 22 kW/sq cm and 12 atm, respectively, at the front stagnation point. The ratio of the radiative heat-transfer rate at the base stagnation point to that at the front stagnation point is found to be about 1/4 for the sphere at Mach 1.8, about 1/30 for the sphere at Mach 4.8, and about 1/6 for the scale model at Mach 1.7. The present experimental results agree well with the theoretical predictions of Park, thus indicating that Park's theory is valid.

Shirai, H.↗

Overview of Advanced Space Propulsion Activities in the Space Environmental Effects Team at MSFC

Exploration of our solar system, and beyond, requires spacecraft velocities beyond our current technological level. Technologies addressing this limitation are numerous. The Space Environmental Effects (SEE) Team at the Marshall Space Flight Center (MSFC) is focused on three discipline areas of advanced propulsion; Tethers, Beamed Energy, and Plasma. This presentation will give an overview of advanced propulsion related activities in the Space Environmental Effects Team at MSFC. Advancements in the application of tethers for spacecraft propulsion were made while developing the Propulsive Small Expendable Deployer System (ProSEDS). New tether materials were developed to meet the specifications of the ProSEDS mission and new techniques had to be developed to test and characterize these tethers. Plasma contactors were developed, tested and modified to meet new requirements. Follow-on activities in tether propulsion include the Air-SEDS activity. Beamed energy activities initiated with an experimental investigation to quantify the momentum transfer subsequent to high power, 5J, ablative laser interaction with materials. The next step with this experimental investigation is to quantify non-ablative photon momentum transfer. This step was started last year and will be used to characterize the efficiency of solar sail materials before and after exposure to Space Environmental Effects (SEE). Our focus with plasma, for propulsion, concentrates on optimizing energy deposition into a magnetically confined plasma and integration of measurement techniques for determining plasma parameters. Plasma confinement is accomplished with the Marshall Magnetic Mirror (M3) device. Initial energy coupling experiments will consist of injecting a 50 amp electron beam into a target plasma. Measurements of plasma temperature and density will be used to determine the effect of changes in magnetic field structure, beam current, and gas species. Experimental observations will be compared to predictions from computer modeling.

Edwards, David↗

Improving Photometric Calibration of Meteor Video Camera Systems

Current optical observations of meteors are commonly limited by systematic uncertainties in photometric calibration at the level of approximately 0.5 mag or higher. Future improvements to meteor ablation models, luminous efficiency models, or emission spectra will hinge on new camera systems and techniques that significantly reduce calibration uncertainties and can reliably perform absolute photometric measurements of meteors. In this talk we discuss the algorithms and tests that NASA's Meteoroid Environment Office (MEO) has developed to better calibrate photometric measurements for the existing All-Sky and Wide-Field video camera networks as well as for a newly deployed four-camera system for measuring meteor colors in Johnson-Cousins BV RI filters. In particular we will emphasize how the MEO has been able to address two long-standing concerns with the traditional procedure, discussed in more detail below.

Ehlert, Steven↗

Performance Measurements of Electric Solid Propellant in an Ablative Pulsed Electric Thruster

Electric solid propellants are advanced solid chemical rocket propellants that can be controlled (ignited, throttled and extinguished) through the application and removal of an electric current. These propellants may also be used for electric in-space propulsion, specifically in the ablative pulsed plasma thruster. In this paper, we will investigate the performance of an electric solid propellant operating in an ablation-fed pulsed plasma device by use of an inverted pendulum micro-Newton thrust stand. Namely, the impulse-per-pulse and the specific impulse of the device using the electric solid propellant will be reported for test runs of 100 pulses and energy levels of 5, 10, 15 and 20 J. Further, the device will also be tested using the current state-of-the-art pulsed plasma thruster propellant, polytetrafluoroethylene. The performance of each propellant will be compared for each energy level using an identical setup and apparatus. This comparison of performance between propellants in a controlled setting will allow for better understanding of previous experimental observations.

Glascock, Matthew S.↗

Fabrication and Testing of Ceramic Matrix Composite Rocket Propulsion Components

The National Aeronautics and Space Administration (NASA) is pursuing using ceramic matrix composites (CMC) as primary structural components for advanced rocket engines. This endeavor is due to the requirement of increasing safety by two orders of magnitude and reducing costs from $10,000/lb to $1,000/lb both within ten years. Out year goals are even more aggressive. Safety gains, through using CMCS, will be realized by increasing temperature margins, tolerance for extreme thermal transients, and damping capability of components and systems, by using components with lower weight and thermal conductivity, etc. Gains in cost reduction, through using CMCS, are anticipated by enabling higher performance systems, using lighter weight components and systems, enabling 100 mission reusability without system refurbishment, greatly reducing cooling requirements and erosion rates, selecting safe fabrication processes that are ideally cost competitive with metal processes at low volume production, etc. This philosophy contrasts the previous philosophy of rocket engine development focused largely on achieving the highest performance with metals and ablatives -- cost and safety were not the focal point of the initial design. Rocket engine components currently being pursued, largely C/SiC and SiC/SiC, include blisks or rotors, 10 foot by 8 foot nozzle ramps, gas generators, thrust chambers, and upperstage nozzles. The Simplex Turbopump CMC blisk effort has just successfully completed a 4.5 year development and test program. The other components mentioned are in the design or fabrication stage. Although the temperature limits of the CMC materials are not quantified in a realistic environment yet, CMC materials are projected to be the only way to achieve significant safety risks mitigation and cost reductions simultaneously. We, the end-users, material fabricators, technology facilitators, and government organizations are charged with developing and demonstrating a much safer and a lot less costly Earth-to-Orbit full-scale propulsion system by 2005.

Effinger, Michael↗

Ares: A Coupling Methodology for Ablation Modeling

To enable modeling of complex and coupled ablation problems, a multi-physics framework is developed. A methodology for modeling shape change in coupled systems is presented. The approach taken to model gas-surface interactions and translate coupled surface phenomena to physically meaningful boundary conditions in the distinct solvers is discussed. Particular emphasis is placed on the nature of coupled boundary conditions pertaining to surface energy and mass balances as well as surface chemistry modeling. The developed methodology is used to simulate a shear test in arc-jet conditions in order to assess the validity of the coupled approach as well as the implementation of the relevant physical processes.

EDL↗

Wavelength Effects In Femtosecond Pulsed Laser Ablation And Deposition

Ultrafast pulsed laser irradiation of solid materials is highly attractive for the micro-and nanostructuring of substrates and for the fabrication of nanostructured deposits. Femtosecond laser pulses promote efficient material removal with reduced heat transfer and high deposition rates of nanometer scale particles free of microscopic particulates. Most of the studies to date have been performed with light pulses centered around the peak wavelength of the Titanium:Sapphire laser, around 800 nm. Analysis of the process over a broader range of wavelengths can provide important information about the processes involved and serve as experimental tests for advanced theoretical models. We report on our current investigations on the effect that laser wavelength of femtosecond pulses has on the superficial nanostructuring induced on biopolymer substrates, and on the characteristics of nanostructured deposits grown by pulsed laser deposition from semiconductor targets.

36 MATERIALS SCIENCE↗

Interferometer density measurements of a high-velocity plasmoid

The plasmoid produced by a half-scale contoured gap coaxial plasma accelerator using ablative polyethylene capillary plasma injectors is measured using a quadrature heterodyne HeNe interferometer. The plasmoid is found to have a sharp rise in density at the leading edge, with a gradual falloff after the peak density. For this early test series, an average bulk density of 5x10{sup 14} cm{sup -3} is observed, with densities up to 8x10{sup 14} cm{sup -3} seen on some shots. Although plasmoid mass is only about 58 mug due to the low current and injected mass used in these tests, good shot-to-shot repeatability is attained making analysis relatively straightforward, thus providing a solid foundation for interpreting future experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Achieving record hot spot energies with large HDC implosions on NIF in HYBRID-E

HYBRID-E is an inertial confinement fusion implosion design that increases energy coupled to the hot spot by increasing the capsule scale in cylindrical hohlraums while operating within the current experimental limits of the National Ignition Facility. HYBRID-E reduces the hohlraum scale at a fixed capsule size compared to previous HYBRID designs, thereby increasing the hohlraum efficiency and energy coupled to the capsule, and uses the cross-beam energy transfer (CBET) to control the implosion symmetry by operating the inner (23° and 30°) and outer (44° and 50°) laser beams at different wavelengths (Δλ> 0). Small case to capsule ratio designs can suffer from insufficient drive at the waist of the hohlraum. We show that only a small amount of wavelength separation between the inner and outer beams (Δλ1-2 Å) is required to control the symmetry in low-gas-filled hohlraums (0.3 mg/cm3 He) with enough drive at the waist of the hohlraum to symmetrically drive capsules 1180 μm in outer radius. This campaign is the first to use the CBET to control the symmetry in 0.3 mg/cm3 He-filled hohlraums, the lowest gas fill density yet fielded with Δλ> 0. We find a stronger sensitivity of hot spot P2 in μm per Angstrom (40–50 μm/Å wavelength separation) than observed in high-gas-filled hohlraums and previous longer pulse designs that used a hohlraum gas fill density of 0.6 mg/cm3. There is currently no indication of transfer roll-off with increasing Δλ, indicating that even longer pulses or larger capsules could be driven using the CBET in cylindrical hohlraums. We show that the radiation flux symmetry is well controlled during the foot of the pulse, and that the entire implosion can be tuned symmetrically in the presence of the CBET in this system, with low levels of laser backscatter out of the hohlraum and low levels of hot electron production from intense laser–plasma interactions. Radiation hydrodynamic simulations can accurately represent the early shock symmetry and be used as a design tool, but cannot predict the late-time radiation flux symmetry during the peak of the pulse, and semi-empirical models are used to design the experiments. Deuterium–tritium (DT)-layered tests of 1100 μm inner radius implosions showed performance close to expectations from simulations at velocities up to ~360 km/s, and record yields at this velocity, when increasing the DT fuel layer thickness to mitigate hydrodynamic mixing of the ablator into the hot spot as a result of defects in the ablator. However, when the implosion velocity was increased, mixing due to these defects impacted performance. The ratio of measured to simulated yield for these experiments was directly correlated with the level of observed mixing. These simulations suggest that reducing the mixing, e.g., by improving the capsule defects, could result in higher performance. In addition, future experiments are planned to reduce the coast time at this scale, delay between the peak compression and the end of the laser, to increase the hot spot convergence and pressure. To reduce the coast time by several hundred ps compared to the 1100 μm inner radius implosions, HYBRID-E has also fielded 1050 μm inner radius capsules, which resulted in higher hot spot pressure and a fusion energy yield of ~170 kJ.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

YBa2Cu3O(7-x)/Au/Nb device structures

Fabrication and testing of planar and edge geometry YBaCuO/Au/Nb superconductor/normal-metal/superconductor (SNS) device structures is described. Weak-link devices of this type serve as sensitive probes of the electrical quality of the YBaCuO/Au interface. The devices are fabricated using laser-ablated, in situ, c-axis-oriented YBaCuO thin films, with both annealed and unannealed YBaCuO/Au interfaces. The planar SNS structures are formed by sequential, in situ deposition of YBaCuO, Au, and Nb, followed by etching, planarization, and wiring electrode definition to produce junctions ranging from 5 to 20 micron on a side. Resulting RnA products are 1-10 x 10 to the -8th ohm-sq cm with critical current densities up to 5 kA/sq cm. For the edge geometry devices, the YBaCuO film edges are patterned using Ar ion milling, followed by a low energy ion cleaning step and in situ deposition of Au and Nb. Devices with areas in the 10 to the -7th to 10 to the -8th sq cm range have been fabricated with RnA products lower than 10 to the -8th ohm-sq cm and critical current densities up to 3kA/sq cm. Both types of devices show ac Josephson steps under microwave irradiation. The best results have been obtained with annealed YBaCuO/Au interfaces.

Hunt, B. D.↗

TPS and Entry Technologies for Future Outer Planet Exploration

The lack of knowledge about the Ice Giants (Voyager being the only probe to briefly visit them) and literally narrow window of planetary alignment for pragmatic missions to the Ice Giants, make them high priority targets in the next decade. The purpose of this white paper is to provide an overview to the NRC Decadal Survey on thermal protection system (TPS) technologies required for future Outer Planet exploration missions. A prime conclusion is that several of the most significant recommendations made during the last decadal survey were addressed positioning the TPS community to better support missions to the Outer Planets. These include maturation of the Heatshield for Extreme Entry Environment Technology (HEEET) to TRL 6 as replacement for Carbon Phenolic (that requires requalification itself), TPS test facility upgrades, and design tool improvements. These new materials and test methods are enabling for Outer Planet missions. However, there are limitations in the HEEET technology and available ground based test facilities that could become mission constraints depending on the science objectives. This white paper discusses opportunities to mitigate those constraints. In addition, if a mission is not scheduled in the near future, these new developments are at risk of becoming unavailable. Therefore, we recommend that NASA invest in a cross-cutting technology program that focuses on sustainment of relevant TPS materials, entry systems, test facilities, design tools, and flight instrumentation.

Outer Planets↗

LANL Testing of DTRA Sponsored ARA Portable LIBS Instruments: Isotopic Module [Slides]

The samples were stationary (not rastered during the experiment). Therefore the laser drilled through the powder sample the adhesive and to , the laser drilled through the powder sample, the adhesive and to the substrate (which can be seen in the photograph). <10 laser shots actually ablated sample. The remaining ~50 laser shots added to the spectral noise decreasing the S/N and making an accurate , decreasing the S/N and making an accurate determination of LOD difficult. If the number of laser shots are decreased, the amount of noise will be reduced increasing the S/N and most likely lower the LOD , increasing the S/N and, most likely, lower the LOD.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Orion Heat Shield Manufacturing Producibility Improvements for the EM-1 Flight Test Program

This paper describes how the ORION program is incorporating improvements in the heat shield design and manufacturing processes reducing programmatic risk and ensuring crew safety in support of NASA's Exploration missions. The approach for the EFT-1 heat shield utilized a low risk Apollo heritage design and manufacturing process using an Avcoat TPS ablator with a honeycomb substrate to provide a one piece heat shield to meet the mission re-entry heating environments. The EM-1 mission will have additional flight systems installed to fly to the moon and return to Earth. Heat shield design and producibility improvements have been incorporated in the EM-1 vehicle to meet deep space mission requirements. The design continues to use the Avcoat material, but in a block configuration to enable improvements in consistant and repeatable application processes using tile bonding experience developed on the Space Shuttle Transportation System Program.

Producibility↗

Photoemission Studies of Metallic Photocathodes Prepared by Pulsed Laser Ablation Deposition Technique

We present the results of our investigation on metallic films as suitable photocathodes for the production of intense electron beams in RF photoinjector guns. Pulsed laser ablation deposition technique was used for growing Mg and Y thin films onto Si and Cu substrates in high vacuum and at room temperature.Different diagnostic methods were used to characterize the thin films deposited on Si with the aim to optimize the deposition process. Photoelectron performances were investigated on samples deposited on Cu substrate in an ultra high vacuum photodiode chamber at 10{sup -7} Pa. Relatively high quantum efficiencies have been obtained for the deposited films, comparable to those of corresponding bulks. Samples could stay for several months in humid open air before being tested in a photodiode cell. The deposition process and the role of the photocathode surface contamination and its influence on the photoelectron performances are presented and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

GammaPod-A new device dedicated for stereotactic radiotherapy of breast cancer

Purpose: This paper introduces a new external beam radiotherapy device named GammaPod that is dedicated for stereotactic radiotherapy of breast cancer. Methods: The design goal of the GammaPod as a dedicated system for treating breast cancer is the ability to deliver ablative doses with sharp gradients under stereotactic image guidance. Stereotactic localization of the breast is achieved by a vacuum-assisted breast immobilization cup with built-in stereotactic frame. Highly focused radiation is achieved at the isocenter due to the cross-firing from 36 radiation arcs generated by rotating 36 individual Cobalt-60 beams. The dedicated treatment planning system optimizes an optimal path of the focal spot using an optimization algorithm borrowed from computational geometry such that the target can be covered by 90%-95% of the prescription dose and the doses to surrounding tissues are minimized. The treatment plan is intended to be delivered with continuous motion of the treatment couch. In this paper the authors described in detail the gamma radiation unit, stereotactic localization of the breast, and the treatment planning system of the GammaPod system. Results: A prototype GammaPod system was installed at University of Maryland Medical Center and has gone through a thorough functional, geometric, and dosimetric testing. The mechanical and functional performances of the system all meet the functional specifications. Conclusions: An image-guided breast stereotactic radiotherapy device, named GammaPod, has been developed to deliver highly focused and localized doses to a target in the breast under stereotactic image guidance. It is envisioned that the GammaPod technology has the potential to significantly shorten radiation treatments and even eliminate surgery by ablating the tumor and sterilizing the tumor bed simultaneously.

60 APPLIED LIFE SCIENCES↗

Hemorrhagic Complications of Percutaneous Cryoablation for Renal Tumors: Results from a 7-year Prospective Study

PurposeCryoablation of renal tumors is assumed to have a higher risk of hemorrhagic complications compared to other ablative modalities. Our purpose was to establish the exact risk and to identify hemorrhagic risk factors.Materials and MethodsThis IRB approved, 7-year prospective study included 261 renal cryoablations. Procedures were under conscious sedation and CT guidance. Pre- and postablation CT was obtained, and hemorrhagic complications were CTCAE tabulated. Age, gender, tumor size, histology, and probes number were tested based on averages or proportions using their exact permutation distribution. “High-risk” subgroups (those exceeding the thresholds of all variables) were tested for each variable alone, and for all combinations of variable threshold values. We compared the subgroup with the best PPV using one variable, with the subgroup with the best PPV using all variables (McNemmar test).ResultsThe hemorrhagic complication rate was 3.5 %. Four patients required transfusions, two required emergent angiograms, one required both a transfusion and angiogram, and two required bladder irrigation for outlet obstruction. Perirenal space hemorrhage was more clinically significant than elsewhere. Univariate risks were tumor size >2 cm, number of probes >2, and malignant histology (P = 0.005, 0.002, and 0.033, respectively). Multivariate analysis showed that patients >55 years with malignant tumors >2 cm requiring 2 or more probes yielded the highest PPV (7.5 %).ConclusionsAlthough older patients (>55 years old) with larger (>2 cm), malignant tumors have an increased risk of hemorrhagic complications, the low PPV does not support the routine use of embolization. Percutaneous cryoablation has a 3.5 % risk of significant hemorrhage, similar to that reported for other types of renal ablative modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of toughened epoxy polymers for high performance composite and ablative applications

A survey of current procedures for the assessment of state of cure in epoxy polymers and for the evaluation of polymer toughness as related to nature of the crosslinking agent was made to facilitate a cause-effect study of the chemical modification of epoxy polymers. Various conformations of sample morphology were examined to identify testing variables and to establish optimum conditions for the selected physical test methods. Dynamic viscoelasticity testing was examined in conjunction with chemical analyses to allow observation of the extent of the curing reaction with size of the crosslinking agent the primary variable. Specifically the aims of the project were twofold: (1) to consider the experimental variables associated with development of "extent of cure" analysis, and (2) to assess methodology of fracture energy determination and to prescribe a meaningful and reproducible procedure. The following is separated into two categories for ease of presentation.

Allen, V. R.↗