Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear science & technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Light output and neutron detection efficiency of boron-based neutron scintillator screens for neutron imaging

Recent research has explored the development of boron-based neutron scintillator screens, which potentially offer improved spatial resolution and neutron capture efficiency compared to traditional lithium-based screens. This work builds upon previous efforts to improve boron-based neutron scintillators by assessing a newer generation of boron-based scintillator screens fabricated using different compositions and fabrication approaches compared to previous generations of screens. Some of the test screens exhibit higher light output than previous efforts and higher neutron capture efficiency than lithium-based screens. This paper describes the current state of screen development, measurement results for the most recent generation of screens, and future activities.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science Addendum

Activation detectors developed at LLNL for measuring real-time neutron fluence from fusion sources are used in the broader fusion community. The recommended fluence operating range of this diagnostic is 5x10 2 – 1x10 6 n/cm2. The upper limit on this fluence range is set by the dead time caused by data transfer between the detector and data acquisition computer. Delaying the start of counting is a possible strategy to operate these detectors in higher fluences.

42 ENGINEERING↗

Characterization of Neutron Emission Rates of Commercial 252 Cf Sources

Accurate knowledge of 252 Cf neutron emission rates is critical for modeling and fast-neutron experiments, yet commercial sources are often supplied without traceable calibration or uncertainty estimates. This report describes a method to characterize 252 Cf sources using a pulse-shape-discrimination (PSD) scintillator. The scintillator was efficiency-calibrated against a time-tagged 252 Cf fission chamber manufactured at ORNL over 40 years ago. Isotopic evolution of the calibration source was modeled using Bateman equations to account for changes in the effective average neutrons per fission at the time of measurement. The calibrated scintillator was then used to measure absolute emission rates of several commercial 252 Cf sources, revealing deviations of up to 12% from nominal manufacturer values. This methodology provides a practical approach for establishing uncertainty-quantified 252 Cf neutron emission rates, improving fidelity in simulations and supporting the accurate interpretation of measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Assembly and Initial Testing of the Gamma-Ray Emission Tomography Assessment Prototype for Irradiated Fuel

The following report documents the final development, assembly, and initial testing of the gamma-ray emission tomography assessment system (GRETA-1) for post-irradiation examination of irradiated fuel. It includes descriptions of the system components, including the high-purity germanium gamma-ray detector, the surrounding shield and collimator, the sample scanning hardware, and the control and collection software package. A series of MCNP6 simulations were performed that modeled a fuel rod scan to test image reconstruction algorithms with a complex and understood source distribution. A bench-top scan of isotopic check sources was also performed and analyzed using standard image reconstruction algorithms. The system is currently awaiting deployment at Idaho National Laboratory’s Hot Fuel Examination Facility.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Neutron Spectrum Determination for the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) with a Multi-Sphere Spectrometer

This report presents the work that was performed to determine the neutron energy spectrum (spectrum) of the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) with a neutron Multi-Sphere Spectrometer (MSS). The spectrometer measurements were performed when the generator is in an INL Materials and Fuels Complex (MFC) laboratory. The measurements were used in a spectrum unfolding software to calculate the neutron spectrum. Based on initial testing of the MSS spectrometer and experience with the unfolding software, an MMRTG spectrum is reported and a justification for the spectrum is provided.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

DFO Shielding Study [Slides]

Presented are slides summarizing a simple radiation shielding study.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

In-Field Alpha Spectrometer Development FY2022 Mid-Year Report

In response to needs identified by the International Atomic Energy Agency (IAEA), Idaho National Laboratory (INL) has developed an In-Field Alpha Spectrometer (IFAS) to allow IAEA safeguards inspectors to collect samples of uranium hexafluoride (UF 6 ) at processing facilities, to perform field assessments to verify uranium enrichment. For sample collection, the IFAS method uses Single-Use Destructive Assay (SUDA) samplers, developed at Pacific Northwest National Laboratory (PNNL), which contain thin zeolite coatings that trap UF6 gas and convert it to the safer, more stable form uranyl fluoride (as a dihydrate, UO 2 F 2 ·2H 2 O). For alpha spectrometry, the IFAS instrument employs a large area silicon semiconductor transducer to detect and record alpha particle energy-deposition events. Over the course of this project INL, PNNL, Oak Ridge National Laboratory worked to optimize the SUDA sample design for alpha spectrometry, to optimize processes for manufacturing, loading, and shipping SUDA samples, and to allow the measurement of loaded SUDA samples. In fiscal year (FY) 2022 INL has bene investigating the reproducibility and measurement precision of IFAS measurements and the associated determination of uranium enrichment.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Alpha Spectrometry – Some Interesting Current Work [Slideds]

This slide deck is intended for presentation at a university, it provides a review of some current INL research that deals with alpha spectrometry. All technical material in this slide deck has been previously reviewed and approved as: INL-CON-10-18755 INL-CON-17-44153 INL-CON-20-57162

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Developing an-In-Field Alpha Spectrometer (IFAS)-for UF 6 Enrichment Measurement [Slides]

This project is developing an in-field alpha spectrometry system for the purpose of assaying grab samples of uranium hexafluoride (UF 6 ) and determining uranium enrichment. This new system will accommodate Single-Use Destructive Assay (SUDA) samples (PNNL) and will be robust to handle elevated beta-decay radiation present in UF 6 samples.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Embedding of Optical Fibers with Electric Field Assisted Sintering

The Electric Field Assisted Sintering (EFAS) technique was used for embedding the fibers, involving rapid heating via an electric current and pressure, reducing fiber exposure to high temperatures. Stainless steel guide tubes were inserted at the fiber-matrix junctions to prevent fiber breakage during the sintering process. The study varied key EFAS parameters—temperature (800°C to 980°C), pressure (40-50 MPa), and hold time (5-10 minutes)—to assess how they influenced fiber embedding. After embedding, the fibers were inspected using optical frequency domain reflectometry (OFDR) to evaluate optical losses and strain along the fiber length. The OFDR scans confirmed that the fibers remained intact, and subsequent transmission tests demonstrated no macroscopic fractures. The embedded samples were also analyzed using scanning electron microscopy (SEM) and X-ray computed tomography (CT) scans. These tests confirmed good bonding between the fiber and matrix with no cracking, though some porosity was present in samples fabricated at lower temperatures. At higher temperatures (980°C), the fiber-matrix bonding was continuous and defect-free, with metal coatings aiding in the bonding process. Elemental analysis showed interdiffusion between the fiber coatings and matrix materials, particularly between the gold coating and stainless steel. Helium leak tests revealed that lower sintering temperatures resulted in matrix porosity, causing leaks, but samples fabricated at 980°C were leak-tight.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗