Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Experimental Testing of Personal Dosimetry Interference from a Portable X-ray Generator

The determination of the disposition route for a legacy drum in a nuclear facility at the Y-12 National Security Complex is supported by non-destructive testing of the drum and its contents. An advanced radiation measurements organization at the Y-12 National Security Complex proposed a series of active measurements using a portable x-ray generator, imaging the drum and its contents with 360-degree visualization. In rooms near the current storage location for the drum, Criticality Accident Alarm System (CAAS) annunciation is degraded, and Personal Radiation Dosimetry Instruments (PRDI’s) are routinely worn by personnel. The Y-12 Development Organization has procured advanced radiation detection devices and a variety of radiation sources for use in active measurements. These devices are being used to support Y-12 operations and safety engineering disciplines to safely address complex challenges throughout the complex. This paper presents the results of experimental testing of the PRDI’s used at Y-12 with the x-ray generator [1], and notes the unique utilization of a decommissioned facility for this work.

61 RADIATION PROTECTION AND DOSIMETRY↗

tomoCAM : fast model-based iterative reconstruction via GPU acceleration and non-uniform fast Fourier transforms

X-ray-based computed tomography is a well established technique for determining the three-dimensional structure of an object from its two-dimensional projections. In the past few decades, there have been significant advancements in the brightness and detector technology of tomography instruments at synchrotron sources. These advancements have led to the emergence of new observations and discoveries, with improved capabilities such as faster frame rates, larger fields of view, higher resolution and higher dimensionality. These advancements have enabled the material science community to expand the scope of tomographic measurements towards increasingly in situ and in operando measurements. In these new experiments, samples can be rapidly evolving, have complex geometries and restrictions on the field of view, limiting the number of projections that can be collected. In such cases, standard filtered back-projection often results in poor quality reconstructions. Iterative reconstruction algorithms, such as model-based iterative reconstructions (MBIR), have demonstrated considerable success in producing high-quality reconstructions under such restrictions, but typically require high-performance computing resources with hundreds of compute nodes to solve the problem in a reasonable time. Here, tomoCAM , is introduced, a new GPU-accelerated implementation of model-based iterative reconstruction that leverages non-uniform fast Fourier transforms to efficiently compute Radon and back-projection operators and asynchronous memory transfers to maximize the throughput to the GPU memory. The resulting code is significantly faster than traditional MBIR codes and delivers the reconstructive improvement offered by MBIR with affordable computing time and resources. tomoCAM has a Python front-end, allowing access from Jupyter -based frameworks, providing straightforward integration into existing workflows at synchrotron facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Air attenuation of high power XFEL beams

The Linac Coherent Light Source-II, a high-repetition-rate x-ray free electron laser, produces high average power as well as high peak power. Air is a key radiation safety element, helping to contain the FEL beams from reaching accessible areas. At high average power, air absorption can produce a high temperature and low-density channel along the x-ray beam path. In this case, the x-ray attenuation no longer follows the Beer-Lambert equation, e-μx . Air attenuation measurements were performed with x-rays focused into a gas cell at the LCLS Time-resolved AMO instrument. The air transmission was observed to significantly increase with x-ray power. Simulations were also performed, which include the thermal processes related to the high average power. In comparison to the measurements, the calculated air transmission is higher, confirming that the simulations are conservative and suitable for radiation safety analyses.

42 ENGINEERING↗

Screening and qualification methodology for SiC end plug processing methods

Deployment of SiC-ceramic-based fuel cladding for light water reactors requires a hermetic end plug–to–cladding joint that can withstand neutron irradiation during normal operation and maintain integrity during design-basis accidents. Reactor experiments have shown that some SiC composite tubes with SiC end plugs can retain hermeticity after irradiation. However, achieving consistent joint performance under irradiation remains a key challenge. Resolving this issue is essential to enable integral irradiation testing and to demonstrate fuel integrity under commercial-reactor irradiation conditions. This report aims to: (1) provide guidance for designing radiation-tolerant end plug joints for SiC cladding; (2) demonstrate experimental methods to detect processing defects that are unstable under neutron irradiation at light-water-reactor-relevant temperatures and doses; and (3) outline a step-by-step approach for designing and conducting reactor experiments to screen joining methods. The resulting data will be used to improve joint processing and to define critical defect types and sizes that must be detected and eliminated through non-destructive evaluation for quality assurance. Based on prior irradiation experiments at the High Flux Isotope Reactor, differential swelling among the cladding, bonding layer, and end plug was identified as an underlying mechanism for irradiation-induced joint degradation. Accordingly, this effect must be considered in the design of radiation-tolerant joining techniques. In this work, miniature SiC end plug joint specimens irradiated during the previous project were analyzed using X-ray computed tomography to characterize the joint microstructure. Digital volume correlation of the tomography data quantified radiation-induced microstructural changes and enabled evaluation of defect-related risks. Finally, ongoing neutron irradiation efforts using larger specimen volumes are presented. These efforts aim to statistically assess joint performance and to build a microstructure–performance (e.g., leak-tightness) dataset to inform processing improvements and quality control.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spectral and Spatial Properties of Amplified Radiation in High Gain Tapering Enhanced Stimulated Super-radiant Amplification Regime (Technical Report)

There is a wide convergence of scientific and industrial interests in understanding the physics of high efficiency conversion of relativistic electron beam power into coherent radiation. Improved understanding would open the door to ultrahigh intensity X-ray laser pulses (single shot coherent imaging and Schwingerfield physics), as well as at longer wavelength for fast throughput material processing (EUV-lithography). Modern particle accelerators can be extremely efficient (approaching 50 %) in terms of wall-plug energy use. State-of-the-art light sources on the other hand do not take advantage of all the available power and most of it is left in the beam and simply wasted on the beam dump. This proposal aimed at developing a program based on Tapered Enhanced Stimulated Superradiant Amplification to address the current limitation in electron-based coherent radiation generation exploiting the progress in high brightness beam generation and strong coupling with the electromagnetic field in a strongly tapered undulator system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection of the Orbital Modulation of Fe Kα Fluorescence Emission in Centaurus X-3 Using the High-resolution Spectrometer Resolve on board XRISM

Abstract The Fe K α fluorescence line emission in X-ray spectra is a powerful diagnostic tool for various astrophysical objects to reveal the distribution of cold matter around photoionizing sources. The advent of the X-ray microcalorimeter on board the XRISM satellite will bring new constraints on the emission line. We present one of the first such results for the high-mass X-ray binary Centaurus X-3, which is composed of an O-type star and a neutron star (NS). We conducted a 155 ks observation covering an entire binary orbit. A weak Fe K α line was detected in all orbital phases at an equivalent width (EW) of 10–20 eV. We found for the first time that its radial velocity (RV) is sinusoidally modulated by the orbital phase. The RV amplitude is 248 ± 13 km s −1 , which is significantly smaller than the value (391 km s −1 ) expected if the emission is from the NS surface, but is consistent if the emission takes place at the O star surface. We discuss several possibilities of the line production site, including the NS surface, O star surface, O star wind, and accretion stream from the O star to the NS. We ran radiative transfer calculation for some of them assuming spherically symmetric density and velocity profiles and an isotropic distribution of X-ray emission from the NS. None of them explains the observed EW and velocity dispersion dependence on the orbital phase, suggesting that more elaborated modeling is needed. In other words, the present observational results have the capability to constrain deviations from these assumptions.

High energy astrophysics↗

Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Role of opacity at the 9 keV back lighter energy used in measuring the equation of state of boron at pressures up to a Gbar

Many experiments have been conducted at the National Ignition Facility to measure the equation of state Hugoniot of plastic, boron, and diamond at extreme pressures up to a Gbar. The “Gbar” design employs a strong spherically converging shock launched through a solid ball of material using a hohlraum radiation drive. The shock front conditions are characterized using X-ray radiography, typically at energies near 9 keV. Here we examine how the opacity of boron at 9 keV changes at high pressures and temperatures. Understanding this is vital to unfolding the density in the shock front as pressures exceed 100 Mbar. We compare opacity calculations from a number of methods including the legacy XSN opacity tables, super transition array (STA), average atom (AVAT), and detailed configuration accounting (DCA) methods. We examine how the changing opacity is correlated with the K-shell occupation calculated using the opacity methods as well as other electronic structure methods such as MECCA, Purgatorio, and an all-electron Kohn-Sham density functional theory calculation that uses optimized all-electron norm-conserving Vanderbilt pseudopotentials (ONCV). We also examine the relative contribution of free-free opacity to the overall opacity, which is dominated by bound-free absorption.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation shielding analysis of the concrete hutch of a long beamline of the Advanced Photon Source Upgrade project

The radiation shielding analysis of the external concrete enclosure of a feature long beamline of the Advanced Photon Source Upgrade project is described in this work. The beamline has 2 undulators that can operate in two different configurations and the source terms are estimated for the worst configuration using the SRW code in the OASYS package as well as the STAC8 code. The shielding analysis is carried out using the STAC8 code, and for the case of pink beam, with the FLUKA code also. Effective dose rates on contact with the outside surface of the concrete walls for pink, reflected full spectrum and monochromatic beams are calculated. For the monochromatic beams, 2 sets of discrete bandwidths (BW) from the Double Crystal Monochromator (DCM) and the full reflectance of the Double Multilayer Monochromator (DMM) are used. Further, due to the size of the direct beam and the energy domain of interest in the direct and scattered fields, the importance of the equivalent dose to the lens of the eye is discussed with respect to the shielding calculations of such facilities. The dose rates outside the concrete hutch in the lateral directions calculated using STAC8 is about 50% higher than the FLUKA results for the case of pink beam but may be considered as a reasonable agreement due to the differences in the calculational methodologies. Those dose rates in the lateral and forward directions are higher for the pink beam to allow full occupancy from the radiation protection point of view. For the full spectrum after 3 reflections, the effective dose rates are less than 0.5 Sv/h in the lateral direction but is higher in the forward region below about 22° with respect to the beam direction. For the DCM beams, except for the scenario with one mirror and 0.1%BW, all dose rates are less than 0.5 Sv/h outside the concrete hutch in the lateral directions. Here, the higher harmonics are what contributes to the dose outside the shield and the bandwidths assumed to derive the photon flux thus becomes important. The dose rates with the DMM are generally lower compared to the 0.1% BW DCM beam but are higher than the results obtained with XOP calculated bandwidths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics with CEBAF at 12 GeV and future opportunities

Here, we summarize the ongoing scientific program of the 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF) and give an outlook into future opportunities. The program addresses important topics in nuclear, hadronic, and electroweak physics, including nuclear femtography, meson and baryon spectroscopy, quarks and gluons in nuclei, precision tests of the standard model and dark sector searches. Potential upgrades of CEBAF and their impact on scientific reach are discussed, such as higher luminosity, the addition of polarized and unpolarized positron beams, and doubling the beam energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Closed Bay-Breeze Circulation and Its Lifecycle From TRACER With a New Orienteering Tape Recorder Diagram

A closed bay-breeze circulation (BBC) followed by a gulf-breeze front (GBF) was observed on 10 September 2022 during the Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) TRACER campaign. Using high-resolution X-band Scanning Cloud Radar (XSACR) and a newly developed orienteering tape recorder diagram, the study analyzed radar reflectivity and Doppler velocity to identify anomalies and track the evolution of these circulations. The BBC, a mesoscale system approximately 30-km long, 30-km wide, and 2-km deep, formed from enhanced horizontal convective rolls along the Galveston Bay coast, progressing northwestward under a 6 m s−1 onshore flow anomaly and reaching 1.5 km depth with return flow aloft. The inland penetration speed was 2 m s−1, driven by an observed 6-9 K land-water temperature contrast. The GBF, coupled to the BBC, intensified with additional southerly flow, penetrating further inland after the BBC collapsed. Passing over the TRACER field site, both fronts significantly impacted boundary layer thermodynamics, dynamics, and aerosol concentration. The BBC event exhibited four lifecycle stages-formation, development, maturation, and dissipation-driven by solar heating, wind field rotation, and interactions with convective eddies and the GBF. This study provides insights into the inland evolution of coastal breeze circulations and their interactions with environmental processes.

54 ENVIRONMENTAL SCIENCES↗

Hotspot conditions achieved in inertial confinement fusion experiments on the National Ignition Facility

We describe the overall performance of the major indirect-drive inertial confinement fusion campaigns executed at the National Ignition Facility. With respect to the proximity to ignition, we can describe the performance of current experiments both in terms of no-burn ignition metrics (metrics based on the hydrodynamic performance of targets in the absence of alpha-particle heating) and in terms of the thermodynamic properties of the hotspot and dense fuel at stagnation—in particular, the hotspot pressure, temperature, and areal density. We describe a simple 1D isobaric model to derive these quantities from experimental observables and examine where current experiments lie with respect to the conditions required for ignition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Search for hidden-charm tetraquark with strangeness in e + e - → $K$ + $D^{*}_{s}$ - $D$ *0 + c.c.*

We report a search for a heavier partner of the recently observed Z cs (3985) - state, denoted as $Z^{'-}_{cs}$, in the process e + e - → $K$ + $D^{*}_{s}$ - $D$ *0 + c.c., based on e + e - collision data collected at the center-of-mass energies of $\sqrt{s}$ = 4.661, 4.682 and 4.699 GeV with the BESIII detector. The $Z^{'-}_{cs}$ is of interest as it is expected to be a candidate for a hidden-charm and open-strange tetraquark. A partial-reconstruction technique is used to isolate K + recoil-mass spectra, which are probed for a potential contribution from $Z^{'-}_{cs}$ → $D^{*}_{s}$ - $D$ *0 + (c.c.). We find an excess of $Z^{'-}_{cs}$ → $D^{*}_{s}$ - $D$ *0 + (c.c.) candidates with a significance of 2.1σ, after considering systematic uncertainties, at a mass of 4123.5 ± 0.7 stat. ± 4.7 syst. ) MeV/c 2 . As the data set is limited in size, the upper limits are evaluated at the 90% confidence level on the product of the Born cross sections (σ BORN ) and the branching fraction ($\mathcal{B}$) of $Z^{'-}_{cs}$ → $D^{*}_{s}$ - $D$ *0 , under different assumptions of the $Z^{'-}_{cs}$ mass from 4.120 to 4.140 MeV and of the width from 10 to 50 MeV at the three center-of-mass energies. The upper limits of σ BORN ∙ $\mathcal{B}$ are found to be at the level of $\mathcal{O}$(1) pb at each energy. Larger data samples are needed to confirm the $Z^{'-}_{cs}$ state and clarify its nature in the coming years.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Kink-driven magnetic reconnection in relativistic jets: consequences for X-ray polarimetry of BL Lacs

ABSTRACT We investigate with relativistic MHD (magnetohydrodynamic) simulations the dissipation physics of BL Lac jets, by studying the synchrotron polarization signatures of particles accelerated by the kink instability in a magnetically dominated plasma column. The non-linear stage of the kink instability generates current sheets, where particles can be efficiently accelerated via magnetic reconnection. We identify current sheets as regions where s = Jδ/B is above some predefined threshold (where B is the field strength, J is the current density, and δ is the grid scale), and assume that the particle injection efficiency scales as ∝J2. X-ray emitting particles have short cooling times, so they only probe the field geometry of their injection sites. In contrast, particles emitting in the optical band, which we follow self-consistently as they propagate away from their injection sites while cooling, sample a larger volume, and so they may be expected to produce different polarimetric signatures. We find that the degree of polarization is roughly the same between X-ray and optical bands, because even the optical emitting particles do not travel far from the current sheet where they were injected, due to lack of sufficient kink-generated turbulence. The polarization angle shows a different temporal evolution between the two bands, due to the different regions probed by X-ray and optical emitting particles. In view of the upcoming IXPE satellite, our results can help constrain whether kink-induced reconnection (as opposed to shocks) can be the source of multiwavelength emission from BL Lacs.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray emission of the radio-loud quasar SDSS J121426.52+140258.9: independent variations between optical/UV and X-ray emission

To understand the X-ray emission of active galactic nuclei (AGNs), we explored the optical-to-X-ray variation correlation of a radio-loud quasar (RLQ) SDSS J121426.52+140258.9 (hereafter J1214+1402) with multi-epoch observations by the Swift and XMM–Newton telescopes. With the historical multiband data, we found that the infrared-to-X-ray flux of RLQ J1214+1402 should not be dominated by the beamed-jet emission. The Swift optical/UV and X-ray light curves showed that J1214+1402 has two optical states, with low flux before 2014 April 8 and high flux after 2014 June 11, but has no significant X-ray variations during the time range between 2007 March 9 and 2014 August 4. This result was supported by the XMM–Newton observations in the time overlapping with Swift. Interestingly, the early XMM–Newton data prior to the Swift time present two unusual emission epochs when J1214+1402 has relatively low optical fluxes but has the brightest X-ray fluxes. The overall independence of optical-to-X-ray variation seems hard to describe by the disc–corona model. With the X-ray spectral fitting, we find that the soft X-ray excess in J1214+1402 appears only during the high optical state when the X-ray emission is at a low state. The soft X-ray excess in J1214+1402 is difficult to explain by an ionized accretion disc; instead, it may be related to the warm corona.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectroscopy of 33 Mg with knockout reactions

In this work, the structure of 33 Mg was investigated by means of two knockout reactions, one-neutron removal from 34 Mg and one-proton removal from 34 Al. Using comparative analysis of the population of observed excited states in the residual 33 Mg, the nature of these states can be deciphered. In addition, the long-standing controversy about the parity of the 33 Mg ground state is resolved using momentum distribution analysis, showing a clear signature for negative parity. Partial cross section measurements are compared with the results of eikonal reaction theory combined with large-scale shell model calculations of this complex nucleus located in the island of inversion, where configuration mixing plays a major role.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗