Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Implants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Using block-copolymer nanolithography as a tool to sensitively evaluate variation in chemical dry etching rates of semiconductor materials with sub-5 nm resolution

Ion implantation is a robust and established method to customize the electronic properties of Si. However, fabricating doped, ultrafine semiconductor nanostructures can be challenging. Ion implantation has well-established effects on the dry etch rates of Si, which becomes increasingly consequential as the target dimension shrinks below a few tens of nanometers. While dry etching arrays of block copolymer-templated nanoscale holes (pitch = 37.5 nm, diameter ~25 nm) into p-type, n-type, and undoped Si, we observed that the lateral etch rate was notably larger for the n-type regions than p-type or undoped regions. By doing image analyses on high resolution electron micrographs of the nanostructured hole arrays, we were able to extract the porosity and average radii of the holes with subnanometer sensitivity and compare the relative etch rates between different doping conditions. We found that degenerately doped n-type silicon consistently etches between approximately 17% and 27% faster in the lateral direction than p-type Si, resulting in significantly larger porosity and, consequently, less mechanical stability. Here, we demonstrate that top-down dimensional analysis of a densely packed porous nanostructure is a robust method for assessing extremely small differences in the lateral, chemical etch rate of doped Si to a degree of sensitivity that was previously unachievable. The minute, dense-packed nature of block copolymer self-assembled nanostructures is shown to be ideal for this application. This proposed method could be useful for designing fabrication processes for heterogeneous nanostructures, as slight dry etch rate variations that may be within process tolerance at the micrometer-scale appear to have nontrivial consequences at the nanometer scale.

42 ENGINEERING↗

Activity in the ferret: oestradiol effects and circadian rhythms

The present study was conducted to determine whether oestradiol increases activity in the European ferret (Mustela furo), whether this effect is sexually dimorphic, and whether a 24-h rhythm is present in the ferret's daily activity. The activity of male and female adult, postpubertally gonadectomized ferrets was monitored while they were maintained singly on a 13:11 light-dark cycle, before and after implantation with oestradiol-17 beta. Gonadectomized male and female ferrets exhibited equal levels of activity, and neither sex exhibited a significant change in activity following oestradiol implantation. None of the ferrets exhibited a strong circadian rhythm, although weak 24-h rhythms and shorter harmonic rhythms were present. Golden hamsters (Mesocricetus auratus), monitored in an identical manner, exhibited strong circadian rhythms. It was concluded that oestradiol administration may not cause an increase in activity in the ferret, and that this species lacks a strong circadian activity rhythm.

Non-NASA Center↗

T wave alternans as a predictor of recurrent ventricular tachyarrhythmias in ICD recipients: prospective comparison with conventional risk markers

INTRODUCTION: The current standard for arrhythmic risk stratification is electrophysiologic (EP) testing, which, due to its invasive nature, is limited to patients already known to be at high risk. A number of noninvasive tests, such as determination of left ventricular ejection fraction (LVEF) or heart rate variability, have been evaluated as additional risk stratifiers. Microvolt T wave alternans (TWA) is a promising new risk marker. Prospective evaluation of noninvasive risk markers in low- or moderate-risk populations requires studies involving very large numbers of patients, and in such studies, documentation of the occurrence of ventricular tachyarrhythmias is difficult. In the present study, we identified a high-risk population, recipients of an implantable cardioverter defibrillator (ICD), and prospectively compared microvolt TWA with invasive EP testing and other risk markers with respect to their ability to predict recurrence of ventricular tachyarrhythmias as documented by ICD electrograms. METHODS AND RESULTS: Ninety-five patients with a history of ventricular tachyarrhythmias undergoing implantation of an ICD underwent EP testing, assessment of TWA, as well as determination of LVEF, baroreflex sensitivity, signal-averaged ECG, analysis of 24-hour Holter monitoring, and QT dispersion from the 12-lead surface ECG. The endpoint of the study was first appropriate ICD therapy for electrogram-documented ventricular fibrillation or tachycardia during follow-up. Kaplan-Meier survival analysis revealed that TWA (P < 0.006) and LVEF (P < 0.04) were the only significant univariate risk stratifiers. EP testing was not statistically significant (P < 0.2). Multivariate Cox regression analysis revealed that TWA was the only statistically significant independent risk factor. CONCLUSIONS: Measurement of microvolt TWA compared favorably with both invasive EP testing and other currently used noninvasive risk assessment methods in predicting recurrence of ventricular tachyarrhythmias in ICD recipients. This study suggests that TWA might also be a powerful tool for risk stratification in low- or moderate-risk patients, and needs to be prospectively evaluated in such populations.

Non-NASA Center↗

The effects of programmed administration of human parathyroid hormone fragment (1-34) on bone histomorphometry and serum chemistry in rats

PTH treatment can result in dramatic increases in cancellous bone volume in normal and osteopenic rats. However, this potentially beneficial response is only observed after pulsatile treatment; continuous infusion of PTH leads to hypercalcemia and bone abnormalities. The purpose of these studies was to determine the optimal duration of the PTH pulses. A preliminary study revealed that human PTH-(1-34) (hPTH) is cleared from circulation within 6 h after sc administration of an anabolic dose of the hormone (80 microg/kg). To establish the effects of gradually extending the duration of exposure to hPTH without increasing the daily dose, we programmed implanted Alzet osmotic pumps to deliver the 80 microg/kg x day dose of the hormone during pulses of 1, 2, and 6 h/day, or 40 microg/kg x day continuously. Discontinuous infusion was accomplished by alternate spacing of external tubing with hPTH solution and sesame oil. After 6 days of treatment, we evaluated serum chemistry and bone histomorphometry. As negative and positive controls, groups of rats received pumps that delivered vehicle only and 80 microg/kg x day hPTH by daily sc injection, respectively. Dynamic and static bone histomorphometry revealed that the daily sc injection and 1 h/day infusion dramatically increased osteoblast number and bone formation in the proximal tibial metaphysis, whereas longer infusion resulted in systemic side-effects, including up to a 10% loss in body weight, hypercalcemia, and histological changes in the proximal tibia resembling abnormalities observed in patients with chronic primary hyperparathyroidism, including peritrabecular marrow fibrosis and focal bone resorption. Infusion for as little as 2 h/day resulted in minor weight loss and changes in bone histology that were intermediate between sc and continuous administration. The results demonstrate that the therapeutic interval for hPTH exposure is brief, but that programmed administration of implanted hormone is a feasible alternative to daily injection as a route for administration of the hormone.

Non-NASA Center↗

A Printed Microscopic Universal Gradient Interface for Super Stretchable Strain‐Insensitive Bioelectronics

Abstract Stretchable electronics capable of conforming to nonplanar and dynamic human body surfaces are central for creating implantable and on‐skin devices for high‐fidelity monitoring of diverse physiological signals. While various strategies have been developed to produce stretchable devices, the signals collected from such devices are often highly sensitive to local strain, resulting in inevitable convolution with surface strain‐induced motion artifacts that are difficult to distinguish from intrinsic physiological signals. Here all‐printed super stretchable strain‐insensitive bioelectronics using a unique universal gradient interface (UGI) are reported to bridge the gap between soft biomaterials and stiff electronic materials. Leveraging a versatile aerosol‐based multi‐materials printing technique that allows precise spatial control over the local stiffnesses with submicron resolution, the UGI enables strain‐insensitive electronic devices with negligible resistivity changes under a 180% uniaxial stretch ratio. Various stretchable devices are directly printed on the UGI for on‐skin health monitoring with high signal quality and near‐perfect immunity to motion artifacts, including semiconductor‐based photodetectors for sensing blood oxygen saturation levels and metal‐based temperature sensors. The concept in this work will significantly simplify the fabrication and accelerate the development of a broad range of wearable and implantable bioelectronics for real‐time health monitoring and personalized therapeutics.

Song, Kaidong [Department of Aerospace and Mechani↗

Integration of polyurethane meniscus scaffold during ACL revision is not reliable at 5 years despite favourable clinical outcome

Abstract Purpose The aim of this study was to evaluate the clinical outcome at 5‐year follow‐up of a one‐step procedure combining anterior cruciate ligament (ACL) reconstruction and partial meniscus replacement using a polyurethane scaffold for the treatment of symptomatic patients with previously failed ACL reconstruction and partial medial meniscectomy. Moreover, the implanted scaffolds have been evaluated by MRI protocol in terms of morphology, volume, and signal intensity. Methods Twenty patients with symptomatic knee laxity after failed ACL reconstruction and partial medial meniscectomy underwent ACL revision combined with polyurethane‐based meniscal scaffold implant. Clinical assessment at 2‐ and 5‐year follow‐ups included VAS, Tegner Activity Score, International Knee Documentation Committee (IKDC), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Lysholm Score. MRI evaluation of the scaffold was performed according to the Genovese scale with quantification of the scaffold’s volume at 1‐ and 5‐year follow‐ups. Results All scores revealed clinical improvement as compared with the preoperative values at the 2‐ and 5‐year follow‐ups. However, a slight, but significant reduction of scores was observed between 2 and 5 years. Concerning the MRI assessment, a significant reduction of the scaffold’s volume was observed between 1 and 5 years. Genovese Morphology classification at 5 years included two complete resorptions (Type 3) and all the remaining patients had irregular morphology (Type 2). With regard to the Genovese Signal at the 5‐year follow‐up, three were classified as markedly hyperintense (Type 1), 15 as slightly hyperintense (Type 2), and two as isointense (Type 1). Conclusion Simultaneous ACL reconstruction and partial meniscus replacement using a polyurethane scaffold provides favourable clinical outcomes in the treatment of symptomatic patients with previously failed ACL reconstruction and partial medial meniscectomy at 5 years. However, MRI evaluation suggests that integration of the scaffold is not consistent. Level of evidence Level IV.

Pereira, Hélder↗

Temperature-dependent cavity swelling in dual-ion irradiated Fe and Fe-Cr ferritic alloys

Fe-Cr ferritic-martensitic (FM) steels are promising structural material candidates for fusion and advanced fission reactors due to their attractive mechanical properties and volumetric swelling resistance. However, significant discrepancies exist regarding the effect of solutes and irradiation temperature on cavity swelling under ion versus neutron irradiation conditions. In this study, simultaneous dual ion irradiations (8 MeV Ni 3+ ions and energy-degraded 3.5 MeV He 2+ ions) were used to quantify the cavity swelling behavior in ultra-high purity Fe and Fe-Cr alloys (3-14 wt.% Cr), Fe-10 wt.% Cr-780 wt.ppm C, and Eurofer97 FM steel. The irradiations were conducted over a wide temperature range (400-550°C) with a mid-range dose of ~30 displacements per atom (dpa) and 0.1 appm/dpa He implantation rate. Here, using state-of-the-art transmission electron microscopy (TEM), we reveal that pure Fe has a ~50°C lower peak swelling temperature difference than Fe-Cr alloys, which is attributed to higher vacancy mobility in pure Fe. Chromium solute appears to strongly suppress cavity swelling in Fe-Cr alloys for temperatures below ~470°C, but seems to have little effect or slightly enhances swelling above ~470°C. Cavities were observed in all the irradiated samples between 400-550°C. This indicates that the narrow temperature range of observable cavities reported in prior ion irradiated Fe-Cr ferritic alloy studies is likely an artifact associated with the use of low ion energies (<5 MeV), which leads to pronounced near-surface and implanted ion effects that suppress cavity swelling even at midrange depths (particularly at high temperatures).

36 MATERIALS SCIENCE↗

Formation of misfit dislocation arrays and helium nanochannels near copper surface assisted by high-temperature graphene deposition

Misfit dislocation arrays (MDAs) at semi-coherent heterogeneous interface have been demonstrated effectiveness to trap and then outgas helium (He) for alleviating void swelling in metals, but limited by atomic-level thin film deposition that is difficult to scale-up for industrial production. In this work, we proposed an innovative strategy that could generate semi-coherent homophase interfaces in a same grain by varying surface energy density assisted by high-temperature graphene (Gr) deposition. This strategy transforms strain energy and surface energy, two originally distinctive processes into successive processes, and demonstrates experimentally and theoretically by introducing {111} copper (Cu) in a {100} Cu grain. Subsequent He implantation and electrical resistivity measurement results suggest that high-density MDAs originated at this {111}/{100} interface could form stable He nanochannels near Cu surface with Gr assistance, manifesting by ultra-low increased ratio of the electrical resistivity (i.e. ~3800% of Cu vs. ~90% of Gr/Cu) after He implantation. Finally, the present findings may provide a new strategy for efficiently managing He and achieving surface protection of advanced metals, merely by depositing a super-rigid material on metal surface to greatly reduce surface energy density.

36 MATERIALS SCIENCE↗

Tungsten disulfide nanotubes enhance flow-induced crystallization and radio-opacity of polylactide without adversely affecting in vitro toxicity

Treatment of vascular disease, from peripheral ischemia to coronary heart disease (CHD), is poised for transformation with the introduction of transient implants designed to “scaffold” regeneration of blood vessels and ultimately leave nothing behind. Improved materials could expand the use of these devices. Here, we examine one of the leading polymers for bioresorbable scaffolds (BRS), polylactide (PLA), as the matrix of nanocomposites with tungsten disulfide (WS 2 ) nanotubes (WSNT), which may provide mechanical reinforcement and enhance radio-opacity. We evaluate in vitro cytotoxicity using vascular cells, flow-induced crystallization and radio-opacity of PLA-WSNT nanocomposites at low WSNT concentration. A small amount of WSNT (0.1 wt%) can effectively promote oriented crystallization of PLA without compromising molecular weight. And radio-opacity improves significantly: as little as 0.5 to 1 wt% WSNT doubles the radio-opacity of PLA-WSNT relative to PLA at 17 keV. The results suggest that a single component, WSNT, has the potential to increase the strength of BRS to enable thinner devices and increase radio-opacity to improve intraoperative visualization. Here, the in vitro toxicity results indicate that PLA-WSNT nanocomposites are worthy of investigation in vivo. Although substantial further preclinical studies are needed, PLA-WSNT nanocomposites may provide a complement of material properties that may improve BRS and expand the range of lesions that can be treated using transient implants.

36 MATERIALS SCIENCE↗

Predicting displacement damage for ion irradiation: Origin of the overestimation of vacancy production in SRIM full-cascade calculations

Ion irradiation and implantation have wide applications that demand accurate determination of displacement damage profile and distribution of implanted ion concentration. The prediction of vacancies is especially important to determine displacements per atom (dpa), the standard parameter of primary radiation damage in materials. However, significant discrepancies exist in estimations of vacancies between full-cascade (F-C) and quick calculation (Q-C) options in the popular computer code SRIM. This study inspected the SRIM code and a relatively new code called Iradina, which uses a similar methodology, to develop an understanding of the origin of vacancy overestimation in the F-C options for SRIM and Iradina. Here, we found that the default values of thresholds (namely final energy in SRIM and replacement energy in Iradina) in displacement production calculations results in excessively large number of calculated vacancies and very few replacements. After conducting multiple calculations using SRIM, Iradina, and MARLOWE (all based on the binary collision approximation), a comparison of the results indicates that there is a shortcoming in the SRIM and Iradina F-C methodology for treating near-threshold collisions. This issue is responsible for the deficiency of replacements and excess of calculated vacancies in the SRIM and Iradina F-C results. Drawing on the principles of collision physics, we propose recommendations for modifying the source codes to address these issues.

36 MATERIALS SCIENCE↗

Enhanced biomechanical performance of additively manufactured Ti-6Al-4V bone plates

As the global trauma fixation devices market expands rapidly, it is imperative to improve the production of fixation devices through enhanced design accuracy and fit for best performance and maximum patient comfort. Selective laser melting (SLM) is one of the mature additive manufacturing methods, which provides a viable route for the rapid production of such devices. In this work, the ability of SLM to produce near-net-shape parts, as desired for medical implants, was utilized for the fabrication of bone plates from Ti-6Al-4V alloy powder. Martensitic microstructure obtained after the printing of alloy resulted in poor ductility, limiting its application in the field of orthopedics. A specially designed repeated cyclic heating and cooling close to but below the β-transus was used to transform from acicular to a bimodal microstructure without the need for plastic deformation prior to heat treatment for improving the ductility. Bone plates subjected to this heat treatment were mechanically tested by means of tensile and 3-point bend tests and demonstrated large improvement in ductility, and the values were comparable to those similar plates prepared from wrought alloy. Other important properties required for implants were assessed, such as corrosion resistance in simulated body fluid and cytocompatibility in vitro using MC3T3-E1 cells. These results for the bone plate after heat treatment were excellent and similar to those of the additively manufactured and wrought plates. Taken together, the performance of the additively manufactured bone plates after subjecting to heat treatment was similar to those of bone plate manufactured using wrought alloy. These results have important implications for the fabrication of patient-specific metallic orthopedic devices using SLM without compromising their biomechanical performance by subjecting them to a tailored heat treatment.

36 MATERIALS SCIENCE↗

Helium causing disappearance of a/2<111> dislocation loops in binary Fe-Cr ferritic alloys

In this work, single and dual-beam self-ion irradiations were performed at 500°C on ultra-high purity Fe14%Cr alloy to ~0.33 displacements-per-atom (dpa), and 0 or 3030 atomic-parts-per-million (appm) helium/dpa, respectively. Using transmission electron microscopy, we reveal that helium can drastically modify the dislocation loop Burgers vector in Fe-Cr alloys. Helium co-implantation caused complete disappearance of a/2<111> type dislocation loops, and the microstructure consisted of only a<100> loops. Conversely, a/2<111> type loops were predominant without He co-implantation. The total loop density remained largely unaffected. The results strikingly contrast literature asserting that helium stabilizes a/2<111> type loops in bcc Fe alloys, based on low temperature irradiations. Collectively analyzing the results with literature suggest that the small positive interaction between helium and self-interstitial atoms (SIA) in Fe predicted by atomistic simulations maybe insufficient to holistically explain the dislocation loop microstructure development in presence of helium. Helium-SIA positive binding inadvertently implies elevated a/2<111> loop fraction and higher loop densities that the present results contradict. Helium induced high cavity density causing a preferential loss of highly glissile <111> clusters, leaving the matrix saturated with <100> type clusters is proposed as a potential mechanism. Further, the in-situ irradiations combined with Burgers vector analysis strengthened the evidence of Cr-induced dislocation loop mobility reduction that appears to stabilize the a/2<111> type loops and causes higher loop densities in Fe-Cr alloys.

36 MATERIALS SCIENCE↗

The role of Cr concentration and temperature on cavity swelling with co-injected helium in dual-ion irradiated Fe and Fe-Cr alloys

The level of chromium plays an essential role in irradiation tolerance of Fe-Cr ferritic alloys. However, conflicting results have been reported regarding the dependence of cavity swelling under irradiation on Cr level and temperature. Here, we have performed a comprehensive set of simultaneous dual-ion (Ni + He) irradiations to high dose (~30 displacements per atom, dpa) at 400–550 °C on a series of ultra-high purity Fe and Fe-Cr binary alloys (3–14 wt.%Cr). Helium co-implantation rates of 0.1 and 10 appm He/dpa were selected to examine He synergistic effects relevant for fission and fusion reactor conditions, respectively. Cavities were observed in all irradiated samples by transmission electron microscopy. The results show that higher He implantation rate causes a shift in the swelling peak to higher temperatures in both Fe and Fe-Cr alloys. When assuming smaller cavities as biased sinks, the non-monotonic nature of the cavity swelling behavior is related to the ratio of biased to unbiased point defect sink strengths. Cr-enriched precipitates were observed in Fe-14Cr irradiated at 400 °C by atom probe tomography. Our analysis suggests the formation of Cr-enriched precipitates could suppress cavity swelling for Fe-Cr alloys with Cr content above 10 wt%.

36 MATERIALS SCIENCE↗

Interplay of strain and phase evolution of laser powder bed fusion Ti–6Al–4V

While additive manufacturing (AM) provides a method of producing geometrically complex and highly detailed structures, the generation of residual strain in AM processes like laser powder bed fusion (L-PBF) can negatively impact performance-enabling properties. In applications such as orthopedic implants, specific performance windows require optimized microstructures in order to obtain desirable properties from multi-phase alloys like Ti–6Al–4V. This research aims to quantify the microscale origins of strain in L-PBF manufactured Ti–6Al–4V by understanding how strain is distributed at the grain and sub-grain scale, the interplay between phase evolution and strain, and examining post-processing strain relief strategies to control these features. Model spinal cage implants were manufactured from Ti–6Al–4V powder via L-PBF and then subjected to strain relieving heat treatment cycles above and below the Ti–6Al–4V β transus as a function of time and cooling rate. Residual strain was then studied via high resolution electron backscatter diffraction (HR-EBSD), and 2D strain maps with sub-micron resolution were generated for each post-processing state. It was found that macroscale thermal strains decreased with heat treatment time, but additional contributions from phase stabilizing residual strains retained primarily in the α' grains as lattice distortive strain remained. Additionally, the retention of β phase significantly changed the strain and dislocation distribution while reducing overall residual strain. In conclusion, these results were validated and reinforced with 3D mesoscopic micromechanical modeling of strain behavior across simulated microstructures, confirming that the local lattice dilation of α’ martensite is a primary contributor of microscale strain generation and retention in L-PBF Ti–6Al–4V.

36 MATERIALS SCIENCE↗

Processes controlling helium bubble dynamics at varying temperatures in simulated radioactive materials

Alpha-radiation damage is known to degrade materials exposed to harsh radiation environments via swelling and embrittlement by nano-scale helium bubbles. How these bubbles grow under varying temperature is essential to understanding and predicting material failure and optimization. Using in situ X-ray scattering, we probed ≈1012 bubbles before, during and after annealing at different temperatures in He-implanted aluminum to reveal a critical growth activation temperature that depends strongly on the helium implantation conditions. An analysis of the data aided by our molecular dynamics simulations identifies multiple temperature-dependent bubble growth mechanisms above and below the critical growth activation temperature. Moreover, the irreversible bubble growth that occurs after annealing for ≈4 h was evaluated using dislocation dynamics and found to negligibly affect the yield strength but may affect subsequent bubble growth at temperature. These in situ results provide valuable insight into bubble growth never observed before and reveal, for the first time, bubble shrinkage after cooling.

36 MATERIALS SCIENCE↗

Combined analysis of HPK 3.1 LGADs using a proton beam, beta source, and probe station towards establishing high volume quality control

The upgrades of the CMS and ATLAS experiments for the high luminosity phase of the Large Hadron Collider will employ precision timing detectors based on Low Gain Avalanche Detectors (LGADs). We present a suite of results combining measurements from the Fermilab Test Beam Facility, a beta source telescope, and a probe station, allowing full characterization of the HPK type 3.1 production of LGAD prototypes developed for these detectors. We demonstrate that the LGAD response to high energy test beam particles is accurately reproduced with a beta source. Finally, we further establish that probe station measurements of the gain implant accurately predict the particle response and operating parameters of each sensor, and conclude that the uniformity of the gain implant in this production is sufficient to produce full-sized sensors for the ATLAS and CMS timing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the polysilicon resistor in silicon strip sensors for ATLAS inner tracker as a function of temperature, pre- and post-irradiation

The high luminosity upgrade of the Large Hadron Collider, foreseen for 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). The expected ultimate total integrated luminosity of 4000 fb –1 means that the strip part of the ITk detector will be exposed to the total particle fluences and ionizing doses reaching the values of 1.6 · 10 15 1 MeV n eq /cm 2 and 0.66 MGy, respectively, including a safety factor of 1.5. Radiation hard n + -in-p micro-strip sensors were developed by the ATLAS ITk strip collaboration and are produced by Hamamatsu Photonics K.K. The active area of each ITk strip sensor is delimited by the n-implant bias ring, which is connected to each individual n + implant strip by a polysilicon bias resistor. The total resistance of the polysilicon bias resistor should be within a specified range to keep all the strips at the same potential, prevent the signal discharge through the grounded bias ring and avoid the readout noise increase. While the polysilicon is a ubiquitous semiconductor material, the fluence and temperature dependence of its resistance is not easily predictable, especially for the tracking detector with the operational temperature significantly below the values typical for commercial microelectronics. Dependence of the resistance of polysilicon bias resistor on the temperature, as well as on the total delivered fluence and ionizing dose, was studied on the specially-designed test structures called ATLAS Testchips, both before and after their irradiation by protons, neutrons, and gammas to the maximal expected fluence and ionizing dose. The resistance has an atypical negative temperature dependence. It is different from silicon, which shows that the grain boundary has a significant contribution to the resistance. Finally, we discuss the contributions by parameterizing the activation energy of the polysilicon resistance as a function of the temperature for unirradiated and irradiated ATLAS Testchips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effects of high energy deuteron ion beam irradiation on the tensile behavior of HT-9

Ion beam implantations are widely performed to understand the effects of irradiation-induced displacement damage on nuclear structural materials. However, the volume of material that can be investigated is often limited by the maximum energies of accelerator facilitates, leading to a limitation in the thickness of samples whose mechanical properties can be evaluated. The Lawrence Berkeley National Laboratory’s 88-Inch Cyclotron offers a wide range of ions and energies, allowing for material ion implantations at larger scales than typical. Four HT-9 SS-J-geometry tensile specimens were polished and then irradiated with deuterons at the 88-Inch Cyclotron to doses of approximately 0.2 dpa prior to small scale tensile testing. Here, the results from this study show irradiation hardening characterized by the tensile test results and black dot irradiation defects. Additionally, a comprehensive look at low temperature irradiations of high-Cr F/M steels is presented and our results show agreement with the available data.

36 MATERIALS SCIENCE↗