At least 649 records · Page 36

Ion beam sputter modification of the surface morphology of biological implants

The surface chemistry and texture of materials used for biological implants may significantly influence their performance and biocompatibility. Recent interest in the microscopic control of implant surface texture has led to the evaluation of ion beam sputtering as a potentially useful surface roughening technique. Ion sources, similar to electron bombardment ion thrusters designed for propulsive applications, are used to roughen the surfaces of various biocompatible alloys or polymer materials. These materials are typically used for dental implants, orthopedic prostheses, vascular prostheses, and artificial heart components. Masking techniques and resulting surface textures are described along with progress concerning evaluation of the biological response to the ion beam sputtered surfaces.

Weigand, A. J.↗

The effects of incomplete annealing on the temperature dependence of sheet resistance and gage factor in aluminum and phosphorus implanted silicon on sapphire

Partial annealing of damage to the crystal lattice during ion implantation reduces the temperature coefficient of resistivity of ion-implanted silicon, while facilitating controlled doping. Reliance on this method for temperature compensation of the resistivity and strain-gage factor is discussed. Implantation conditions and annealing conditions are detailed. The gage factor and its temperature variation are not drastically affected by crystal damage for some crystal orientations. A model is proposed to account for the effects of electron damage on the temperature dependence of resistivity and on silicon piezoresistance. The results are applicable to the design of silicon-on-sapphire strain gages with high gage factors.

Pisciotta, B. P.↗

Ion-beam-sputter modification of the surface morphology of biological implants

The surface chemistry and texture of materials used for biological implants may significantly influence their performance and biocompatibility. Recent interest in the microscopic control of implant surface texture has led to the evaluation of ion-beam sputtering as a potentially useful surface roughening technique. Ion sources, similar to electron-bombardment ion thrusters designed for propulsive applications, are used to roughen the surfaces of various biocompatible alloys or polymer materials. These materials are typically used for dental implants, orthopedic prostheses, vascular prostheses, and artificial heart components. Masking techniques and resulting surface textures are described along with progress concerning evaluation of the biological response to the ion-beam-sputtered surfaces.

Weigand, A. J.↗

Applications of ion implantation for high efficiency silicon solar cells

Ion implantation is utilized for the dopant introduction processes necessary to fabricate a silicon solar cell. Implantation provides a versatile powerful tool for development of high efficiency cells. Advantages and problems of implantation and the present status of developmental use of the technique for solar cells are discussed.

Minnucci, J. A.↗

A feasibility study of ion implantation techniques for mass spectrometer calibration

An experimental study was undertaken to examine the feasibility of using ion-implanted filaments doped with either an alkali metal or noble gas for in situ recalibration of onboard mass spectrometers during extended space missions. Implants of rubidium and krypton in rhenium ribbon filaments were subsequently tested in a bakeable 60 deg sector mass spectrometer operating in the static mode. Surface ionization and electron impact ion sources were both used, each yielding satisfactory results. The metallic implant with subsequent ionization provided a means of mass scale calibration and determination of system operating parameters, whereas the noble gas thermally desorbed into the system was more suited for partial pressure and sensitivity determinations.

Koslin, M. E.↗

MIS diode structure in As/+/ implanted CdS

Structure made by As implantation of carefully prepared high-conductivity CdS surfaces followed by Pt deposition and 450 C anneal display rectifying, although substantially different, I-V characteristics in the dark and during illumination with subband-gap light. Structures prepared in the same way on an unimplanted portion of the substrate have similar I-V characteristics, except that the forward turnover voltage for an illuminated unimplanted diode is much smaller than that for an implanted diode. It is suggested that the charge conduction in both structures is dominated by hole and/or electron tunneling through a metal-semiconductor potential barrier. The tunneling processes appear to be quite sensitive to subband-gap illumination, which causes the dramatic decreases of turnover voltages and apparent series resistances. The difference in turnover voltage appears to be caused by interface states between the Pt electrode and the implanted layer, which suggests a MIS model.

Hutchby, J. A.↗

Ion-probe studies of artificially implanted ions in lunar samples

The ion microprobe at the Johnson Space Center was used to study depth profiles of artificially implanted ions in lunar samples. Five polished sections of typical mare basalts (12040 and 12018) were irradiated with nine different elements at two energies and the resulting concentrations were measured as a function of depth in the minerals plagioclase, pyroxene, and ilmenite. These preliminary simulation experiments were undertaken to determine whether the ion probe can be used to measure solar-wind-implanted elements on the surface of lunar rock crystals and soil grains and to study mechanisms for the redistribution. The results obtained so far demonstrate that depth profiles can indeed be measured with the ion probe. From estimated exposure times of mature soil grains and selected vug crystals, it appears possible (if difficult) to detect several solar-wind-implanted elements.

Zinner, E.↗

Characterization of silicon-gate CMOS/SOS integrated circuits processed with ion implantation

Progress in developing the application of ion implantation techniques to silicon gate CMOS/SOS processing is described. All of the conventional doping techniques such as in situ doping of the epi-film and diffusion by means of doped oxides are replaced by ion implantation. Various devices and process parameters are characterized to generate an optimum process by the use of an existing SOS test array. As a result, excellent circuit performance is achieved. A general description of the all ion implantation process is presented.

Woo, D. S.↗

Tissue response to peritoneal implants

Peritoneal implants were fabricated from poly 2-OH, ethyl methacrylate (HEMA), polyetherurethane (polytetramethylene glycol 1000 MW, 1,4 methylene disocynate, and ethyl diamine), and untreated and sputter treated polytetrafluoroethylene (PTFE). The sputter treated PTFE implants were produced by an 8 cm diameter argon ion source. The treated samples consisted of ion beam sputter polished samples, sputter etched samples (to produce a microscopic surface cone texture) and surface pitted samples (produced by ion beam sputtering to result in 50 microns wide by 100 microns deep square pits). These materials were implanted in rats for periods ranging from 30 minutes to 14 days. The results were evaluated with regard to cell type and attachment kinetics onto the different materials. Scanning electron microscopy and histological sections were also evaluated. In general the smooth hydrophobic surfaces attracted less cells than the ion etched PTFE or the HEMA samples. The ion etching was observed to enhance cell attachment, multinucleated giant cell (MNGC) formation, cell to cell contact, and fibrous capsule formation. The cell responsed in the case of ion etched PTFE to an altered surface morphology. However, equally interesting was the similar attachment kinetics of HEMA verses the ion etched PTFE. However, HEMA resulted in a markedly different response with no MNGC's formation, minimal to no capsule formation, and sample coverage by a uniform cell layer.

Picha, G. J.↗

Processing of silicon solar cells by ion implantation and laser annealing

Methods to improve the radiation tolerance of silicon cells for spacecraft use are described. The major emphasis of the program was to reduce the process-induced carbon and oxygen impurities in the junction and base regions of the solar cell, and to measure the effect of reduced impurity levels on the radiation tolerance of cells. Substrates of 0.1, 1.0 and 10.0 ohm-cm float-zone material were used as starting material in the process sequence. High-dose, low-energy ion implantation was used to form the junction in n+p structures. Implant annealing was performed by conventional furnace techniques and by pulsed laser and pulsed electron beam annealing. Cells were tested for radiation tolerance at Spire and NASA-LeRC. After irradiation by 1 MeV electrons to a fluence of 10 to the 16th power per sq cm, the cells tested at Spire showed no significant process induced variations in radiation tolerance. However, for cells tested at Lewis to a fluence of 10 to the 15th power per sq cm, ion-implanted cells annealed in vacuum by pulsed electron beam consistently showed the best radiation tolerance for all cell resistivities.

Minnucci, J. A.↗

CO2 laser waveguiding in proton implanted GaAs

Surface layers capable of supporting optical modes at 10.6 microns have been produced in n-type GaAs wafers through 300 keV proton implantation. The dominant mechanism for this effect appears to be free carrier compensation. Characterization of the implanted layers by analysis of infrared reflectivity spectra and synchronous coupling at 10.6 microns produced results in good agreement with elementary models. These results of sample characterization by infrared reflectivity and by CO2 laser waveguiding as implanted are presented and evaluated.

Jenkinson, H. A.↗

Use of low energy hydrogen ion implants in high efficiency crystalline silicon solar cells

This program is a study of the use of low energy hydrogen ion implantation for high efficiency crystalline silicon solar cells. The first quarterly report focuses on two tasks of this program: (1) an examination of the effects of low energy hydrogen implants on surface recombination speed; and (2) an examination of the effects of hydrogen on silicon regrowth and diffusion in silicon. The first part of the project focussed on the measurement of surface properties of hydrogen implanted silicon. Low energy hydrogen ions when bombarded on the silicon surface will create structural damage at the surface, deactivate dopants and introduce recombination centers. At the same time the electrically active centers such as dangling bonds will be passivated by these hydrogen ions. Thus hydrogen is expected to alter properties such as the surface recombination velocity, dopant profiles on the emitter, etc. In this report the surface recombination velocity of a hydrogen emplanted emitter was measured.

Fonash, S. J.↗

Corrosion behavior of surface films on boron-implanted high purity iron and stainless steels

Boron (dose, 2 x 10 to the 17th ions/sq cm) was implanted into high purity iron, AISI 316 austenitic stainless steel, and AISI 440C martensitic stainless steel, at 40 keV. The film structure of implanted samples was examined and characterized by contrast and diffraction analyses utilizing transmission electron microscopy. The effect of B(+) ion implantation on the corrosion behavior was studied using the potentiodynamic polarization technique. Tests were performed in deaerated 1 N H2SO4 and 0.1 M NaCl solutions. Scanning electron microscopy was used to examine the morphology of the corroded surfaces after testing.

Kim, H. J.↗

Calculation of recoil implantation profiles using known range statistics

A method has been developed to calculate the depth distribution of recoil atoms that result from ion implantation onto a substrate covered with a thin surface layer. The calculation includes first order recoils considering projected range straggles, and lateral straggles of recoils but neglecting lateral straggles of projectiles. Projectile range distributions at intermediate energies in the surface layer are deduced from look-up tables of known range statistics. A great saving of computing time and human effort is thus attained in comparison with existing procedures. The method is used to calculate recoil profiles of oxygen from implantation of arsenic through SiO2 and of nitrogen from implantation of phosphorus through Si3N4 films on silicon. The calculated recoil profiles are in good agreement with results obtained by other investigators using the Boltzmann transport equation and they also compare very well with available experimental results in the literature. The deviation between calculated and experimental results is discussed in relation to lateral straggles. From this discussion, a range of surface layer thickness for which the method applies is recommended.

Fung, C. D.↗

Behavior of ion-implanted junction diodes in 3C SiC

p-n junction diodes have been formed by ion implantation of B or Al in 3C SiC and annealing at 1365 C. The current-voltage characteristics of the Al-implanted structures show little rectification. The B-implanted diodes show rectification, with ideality factors of 2.2 and higher, breakdown voltages between 5 and 10 V, and a series resistance of the order of 20 kohm. The current-voltage characteristics were measured between room temperature and 270 C. The extracted ideality factors increase with temperature.

Avila, R. E.↗

Ion-implanted high microwave power indium phosphide transistors

Encapsulated rapid thermal annealing (RTA) has been used in the fabrication of InP power MISFETs with ion-implanted source, drain, and active-channel regions. The MISFETs had a gate length of 1.4 microns. Six to ten gate fingers per device, with individual gate finger widths of 100 or 125 microns, were used to make MISFETs with total gate widths of 0.75, 0.8, or 1 mm. The source and drain contact regions and the channel region of the MISFETs were fabricated using Si implants in InP at energies from 60 to 360 keV with doses of (1-560) x 10 to the 12th/sq cm. The implants were activated using RTA at 700 C for 30 sec in N2 or H2 ambients using an Si3N4 encapsulant. The high-power high-efficiency MISFETs were characterized at 9.7 GHz, and the output microwave power density for the RTA conditions used was as high as 2.4 W/mm. For a 1-W input at 9.7 GHz gains up to 3.7 dB were observed, with an associated power-added efficiency of 29 percent and output power density 70 percent greater than that of GaAs MESFETs.

Biedenbender, Michael D.↗

Implantable Electrode For Critical Locations

Implantable electrode holds itself in place until body tissue grows around it and retains it. Sheath covers electrode during implantation. Partially retracted after implantation and completely retracted after growth of tissue onto electrode. Intended to provide electrical stimuli to muscles having become inactive through accident or disease. Helps paraplegics and others to exercise voluntary control over arms and legs.

Collins, Earl R., Jr.↗

Comparison of observed and calculated implanted ion distributions outside Comet Halley's bow shock

This paper compares calculated and measured energy spectra of implanted H(+) and O(+) ions on the assumption that the pickup geometry is quasi-parallel and about 1 percent of the waves generated by the cometary pickup process propagate backward (toward the comet). The model provides a good description of the implanted O(+) and H(+) energy distribution near the pickup energies. The thickness of the implanted ion velocity distribution shells was nearly constant between 2.5 and 1.2 million km (just outside the shock) along the inbound Giotto trajectory. The explanation is that the velocity diffusion coefficient and characteristic diffusion time vary approximately as 1/r and r, respectively, and therefore their product (which determines the velocity shell thickness) remains nearly constant.

Gombosi, T. I.↗