Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “statistical model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Superior Daily and Sub-Daily Precipitation Statistics for Intense and Long-Lived Storms in Global Storm-Resolving Models

Here, daily and sub-daily precipitation statistics are investigated from three global model ensembles: (a) global storm-resolving models (GSRMs) with typical horizontal resolutions of ~4 km, (b) “high”-resolution global models with typical resolutions of ~50 km and (c) “standard”-resolution global models with typical resolutions of ~100 km. Compared to two satellite rainfall datasets, GSRMs convincingly exhibit superior performance for statistics of heavier rain rate events including their diurnal cycle, spatial propagation and the amount contributed by intense precipitation, but not for statistics of weaker or shorter duration precipitation. Both high- and standard-resolution models fail to simulate the correct phase and amplitude of diurnal cycle of precipitation and the propagating convection in the Central US, but high-resolution models show relative improvement in the distribution of precipitation frequency and amount, especially for intense precipitation.

54 ENVIRONMENTAL SCIENCES↗

Using Direct Numerical Simulation of Pore-Level Events to Improve Pore-Network Models for Prediction of Residual Trapping of CO2

Direct numerical simulation and pore-network modeling are common approaches to study the physics of two-phase flow through natural rocks. For assessment of the long-term performance of geological sequestration of CO 2 , it is important to model the full drainage-imbibition cycle to provide an accurate estimate of the trapped CO 2 . While direct numerical simulation using pore geometry from micro-CT rock images accurately models two-phase flow physics, it is computationally prohibitive for large rock volumes. On the other hand, pore-network modeling on networks extracted from micro-CT rock images is computationally efficient but utilizes simplified physics in idealized geometric pore elements. This study uses the lattice-Boltzmann method for direct numerical simulation of CO 2 -brine flow in idealized pore elements to develop a new set of pore-level flow models for the pore-body filling and snap-off events in pore-network modeling of imbibition. Lattice-Boltzmann simulations are conducted on typical idealized pore-network configurations, and the interface evolution and local capillary pressure are evaluated to develop modified equations of local threshold capillary pressure of pore elements as a function of shape factor and other geometrical parameters. The modified equations are then incorporated into a quasi-static pore-network flow solver. The modified model is applied on extracted pore-network of sandstone samples, and saturation of residual trapped CO 2 is computed for a drainage-imbibition cycle. The modified model yields different statistics of pore-level events compared with the original model; in particular, the occurrence of snap-off in pore-throats is reduced resulting in a more frontal displacement pattern along the main injection direction. Compared to the original model, the modified model is in closer agreement with the residual trapped CO 2 obtained from core flow experiments and direct numerical simulation.

Kohanpur, Amir H.↗

Improved Statistics for F-theory Standard Models

Much of the analysis of F-theory-based Standard Models boils down to computing cohomologies of line bundles on matter curves. By varying parameters one can degenerate such matter curves to singular ones, typically with many nodes, where the computation is combinatorial and straightforward. The question remains to relate the (a priori possibly smaller) value on the original curve to the singular one. In this work, we introduce some elementary techniques (pruning trees and removing interior edges) for simplifying the resulting nodal curves to a small collection of terminal ones that can be handled directly. When applied to the QSMs, these techniques yield optimal results in the sense that obtaining more precise answers would require currently unavailable information about the QSM geometries. This provides us with an opportunity to enhance the statistical bounds established in earlier research regarding the absence of vector-like exotics on the quark-doublet curve.

Bies, Martin↗

Stream Temperature Prediction in a Shifting Environment: Explaining the Influence of Deep Learning Architecture

Stream temperature is a fundamental control on ecosystem health. Recent efforts incorporating process guidance into deep learning models for predicting stream temperature have been shown to outperform existing statistical and physical models. This performance is in part because deep learning architectures can actively learn spatiotemporal relationships that govern how water and energy propagate through a river network. However, exploration of how spatiotemporal awareness and process guidance influence a model's generalizability under shifting environmental conditions such as climate change is limited. Here, we use Explainable Artificial Intelligence (XAI) to interrogate how differing deep learning architectures affect a model's learned spatial and temporal dependencies, and how those learned dependencies affect a model's ability to maintain high accuracy when applied to unseen environmental conditions. Using the Delaware River Basin in the northeastern United States as a test case, we compare two spatiotemporally aware process–guided deep learning models for predicting stream temperature (a recurrent graph convolution network—RGCN, and a temporal convolution graph model—Graph WaveNet). Both models achieve equally high predictive performance when testing data are well represented in the training data (test root mean squared errors of 1.64°C and 1.65°C); however, Graph WaveNet significantly outperforms RGCN in 4 out of 5 experiments where test partitions represent different types of unseen environmental conditions. XAI results show that the architecture of Graph WaveNet leads to learned spatial relationships with greater fidelity to physical processes, and that this fidelity improves the generalizability of the model when applied to shifting and/or unseen environmental conditions.

54 ENVIRONMENTAL SCIENCES↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Graphite Creep Uncertainty Analysis

Radiation damage estimation is an important component of the post irradiation analysis of the Advanced Graphite Creep (AGC) experiment. It depends primarily on the fast fluence, which is determined using well established methods of spectral adjustment. These are based on best estimates from models such as Monte Carlo N-Particle (MCNP), input cross-sections, and measured activities from flux wires in the experiment. Each of these parameters can propagate uncertainties which will affect the uncertainty in the calculated dose levels for AGC, or any experiment irradiated within a reactor. While the methods of propagating uncertainty are well-established, the final uncertainty estimates they provide are only as good as the estimates of uncertainty in the inputs on which they are based. The purpose of this work is to outline some deficiencies in the ways these input uncertainties are presently estimated, and to outline a methodology by which they can be improved. The fast fluence and radiation damage received by graphite specimens irradiated in the Advanced Graphite Creep (AGC) experiments is presently estimated using spectral adjustment methods that are based on both flux wire activity measurements, and MCNP model predictions. This work describes an ongoing effort to quantify and propagate uncertainties in inputs to the spectral adjustment process, and thereby quantify the resultant error in radiation damage (dpa) estimates. The effort is multi-faceted, and we consider the impacts of both the set of flux wires selected, and the counting process. An expanded set of flux wires is identified that provides a more comprehensive data set on the fast spectrum. To address the counting process itself, a series of round-robin measurements in several reactor metrology laboratories across the Department of Energy (DOE) complex and nuclear industry are being undertaken to refine the American Society for Testing and Materials (ASTM) standards for flux wire measurements. To address the contribution of uncertainty in the MCNP model predictions, an uncertainty quantification (UQ) tool has been developed that statistically samples the model input parameters, runs a series of cases, and assimilates the results to provide an overall uncertainty. The impact of the MCNP UQ tool results is demonstrated by re-analyzing previous AGC flux wire and irradiation data. While the expanded flux wire set obviously cannot be added to these experiments retroactively, plans for future graphite irradiations are outlined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-resolution (30-m) urban land cover projections for Los Angeles California Urban Area: 2010 to 2100 under SSP5

These data represent simulations of future land use and land cover (LULCC) for Los Angeles urban area (U.S. Census Bureau defined area) as raster tiff images at a 30-m pixel resolution and at decadal time steps from 2010 to 2100. LULCC classes in this product follow the National Land Cover Dataset (NLCD) classification. NLCD 21-24 correspond to open developed, low developed, medium developed, and high developed urban land classes, respectively. Only urban land cover classes (NLCD class 21, 22, 23, and 24) are dynamic over time; however, all NLCD classes are included in the final product. Therefore, NLCD classes that do not convert to an urban class will be similar to year 2000. The products were developed using a hybridized statistical and cellular automata approach. Linear mixed models (LMMs) were used to estimate future urban land budgets based on 1-km urban land fraction projections from Gao and Pesaresi (2021), whereas separate generalized linear mixed models (GLMMs) were used to estimate shifts in urban land intensities based on retrospective shifts in NLCD urban class intensities over a 20- year period. Based on urban land allocations from the statistical models, a cellular-automata and downscaling routine was used to simulate dynamic urban land expansion at a 30-m resolution based on suitability criteria. Scenarios of future urban landcover change projections include variant solutions for the Shared Socioeconomic Pathway 5 (SSP5) based on different population assumptions, different land use intensification assumptions, variable land zoning constraints, and iterative adjustments to correct for over allocation of urban expansion across decadal time periods from 2010 to 2100. This results in 320 raster products.

Land↗

High-resolution (30-m) urban land cover projections for Los Angeles California Urban Area: 2010 to 2100 under SSP3 and SSP5 [Updated simulations based on population-driven urban intensity transitions]

These data (v3) are updated from previous versions (1 and 2) in that they include consider the effects of population on transitions in urban land intensity. This leads to more reasonable differences in urban land projections under variant SSPs. For the present dataset, both SSP3 and SSP5 are provided. These data represent simulations of future land use and land cover (LULCC) for Los Angeles urban area (U.S. Census Bureau defined area) as raster tiff images at a 30-m pixel resolution and at decadal time steps from 2010 to 2100. LULCC classes in this product follow the National Land Cover Dataset (NLCD) classification. NLCD 21-24 correspond to open developed, low developed, medium developed, and high developed urban land classes, respectively. Only urban land cover classes (NLCD class 21, 22, 23, and 24) are dynamic over time; however, all NLCD classes are included in the final product. Therefore, NLCD classes that do not convert to an urban class will be similar to year 2000. The products were developed using a hybridized statistical and cellular automata approach. Linear mixed models (LMMs) were used to estimate future urban land budgets based on 1-km urban land fraction projections from Gao and Pesaresi (2021), whereas separate generalized linear mixed models (GLMMs) were used to estimate shifts in urban land intensities based on retrospective shifts in NLCD urban class intensities over a 20- year period. Based on urban land allocations from the statistical models, a cellular-automata and downscaling routine was used to simulate dynamic urban land expansion at a 30-m resolution based on suitability criteria. Scenarios of future urban landcover change projections include variant solutions for the Shared Socioeconomic Pathway 5 (SSP5) and SSP 3 based on different population assumptions, different land use intensification assumptions, variable land zoning constraints, and iterative adjustments to correct for over allocation of urban expansion across decadal time periods from 2010 to 2100. This results in 320 raster products.

Land↗

The concept of spin ice graphs and a field theory for their charges

Originally detected in rare earth pyrochlores, spin ice physics is now being artificially extended to a variety of geometries that control collective behavior and exotic properties, making graph theory their proper framework. We relate spin ice notions, such as ice rule, ice manifold, Coulomb phases, charges, and monopoles, to graph-theoretical notions, such as balance, in/out-degrees, and Euler paths. We then propose a field-theoretical treatment in which topological charges and monopoles are the degrees of freedom, while the binary spins are subsumed in an entropic interaction among charges. We show that for a spin ice on a graph in a Gaussian approximation, the kernel of the entropic interaction is the inverse of the graph Laplacian, and we compute screening functions from the graph spectra as Green operators for the screened Poisson problem on a graph. We then apply the treatment to star graphs, tournaments, cycles, and regular spin ice in different dimensions. Our aim is twofold: to set spin ice physics in a proper graph setting, where only topological rather than geometrical notions hold, and to invite graph theorists to contribute their powerful tools to the field of spin ice.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scale bridging damage model for quasi-brittle metals informed with crack evolution statistics

Computationally efficient methods for bridging length scales, from highly resolved micro/meso-scale models that can explicitly model crack growth, to macro-scale continuum models that are more suitable for modeling large parts, have been of interest to researchers for decades. In this work, an improved brittle damage model is presented for the simulation of dynamic fracture in continuum scale quasi-brittle metal components. Crack evolution statistics, including the number, length, and orientation of individual cracks, are extracted from high-fidelity, finite discrete element method (FDEM) simulations and used to generate effective material moduli that reflect the material’s damaged state over time. This strategy allows for the retention of small-scale physical behaviors such as crack growth and coalescence in continuum scale hydrodynamic simulations. However, the high-fidelity simulations required to generate the crack statistics are computationally expensive. Thus, steps were taken to produce a flexible constitutive model to reduce the number of costly high-fidelity simulations needed to produce accurate results. A new stress based degradation criterion is introduced for the degradation of individual material zones. This allows for the development of a heterogeneous damage distribution within the bulk material. Then a flow stress model is added to the hydrodynamic simulation to account for plasticity in quasi-brittle materials. As a result, the effective moduli model can be applied to a larger range of materials. The effective moduli constitutive model is used to simulate beryllium flyer plate experiments. The results from the continuum scale simulations using statistics from a single high-fidelity simulation are found to be in excellent agreement with numerical and experimental velocity interferometer data. The same set of crack statistics are used to extrapolate the results of a higher rate flyer plate case using the effective moduli model. In conclusion, the extension of this model to higher rate cases shows promise for further reducing the number of costly high-fidelity simulations needed to generate crack statistics.

36 MATERIALS SCIENCE↗

Constitutive model development of aluminum alloy 1100 for elevated temperature forming process

Commercially pure aluminum alloy, AA1100, presents good electrical and thermal conductivity, high formability, and low cost. Those favorable characteristics have the potential to enable bipolar plates with improved economics and enhanced performance compared to current stainless steel bipolar plates for proton exchange membrane fuel cells. An accurate constitutive model is essential to develop and optimize processing parameters and effectively control the forming process. Here, the objective of this work is to develop a constitutive model of AA1100 that is able to simulate stress-strain relation, formed geometry, and predict the onset of fracture strain to avoid forming failure. Initially, a set of tensile tests at temperature between 300 and 500°C and strain rate between 0.005 and 1.0/s were conducted to examine the deformation behavior. Then, a set of damage-based unified visco-plastic constitutive equations is proposed and calibrated based on the results of stress-strain data. A genetic algorithm optimization method is applied to search for best fitting material constants in constitutive equations. The proposed model shows good predictability of both the stress-strain relation and fracture strain at low strain rate and high temperature conditions. The accuracy of proposed model is also evaluated statistically. A comparison of the proposed model with three popular models (Arrhenius-type mode, Johnson-Cook model and Zerilli-Armstrong model) was made. The proposed model shows the best experimental agreement with correlation coefficient of 0.96 in contrast to 0.25, 0.38 and 0.75 for the popular models, respectively. The proposed model can help to optimize the elevated temperature forming process and guide die design to enable optimal geometric features in the formed components.

08 HYDROGEN↗

Spectral statistics of a minimal quantum glass model

Glasses have the interesting feature of being neither integrable nor fully chaotic. They thermalize quickly within a subspace but thermalize much more slowly across the full space due to high free energy barriers which partition the configuration space into sectors. Past works have examined the Rosenzweig-Porter (RP) model as a minimal quantum model which transitions from localized to chaotic behavior. In this work we generalize the RP model in such a way that it becomes a minimal model which transitions from glassy to chaotic behavior, which we term the “Block Rosenzweig-Porter” (BRP) model. We calculate the spectral form factors of both models at all timescales larger than the inverse spectral width. Whereas the RP model exhibits a crossover from localized to ergodic behavior at the Thouless timescale, the new BRP model instead crosses over from glassy to fully chaotic behavior, as seen by a change in the steepness of the ramp of the spectral form factor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

How is statistical thinking useful for evaluating foundation models?

Good’s statement appears to be rather prescient – while humanity has marched on through to the 21st century, modern artificial intelligence (AI), driven by a menagerie of immense deep-neural-network architectures aided with parallel computation, seems positioned to change life as we know it. It would be an understatement to say that the world has been captivated by AI. Recent engineering feats, such as autonomous vehicles and generative AI, have gripped the public sphere, and AI is poised to disrupt a host of industries – including software, pharmaceuticals, healthcare, manufacturing, entertainment, and a slew of others; indeed, one is hard pressed to find any industry that does not claim to bear an impact from the so-called AI revolution.

97 MATHEMATICS AND COMPUTING↗

Implementation of a Three-Dimensional Planetary Boundary Layer Parameterization in a Coupled Modeling System and Evaluation of "Gray Zone" Simulations of a Wind-Wave Event Off the US California Coast Using Observations

A three-dimensional (3D) planetary boundary layer (PBL) parameterization was added to the Coupled Ocean Atmosphere Wave Sediment Transport (COAWST) model and the first coupled atmosphere/wave "gray zone" simulations were carried out using the 3D PBL parameterization. A case study of a significant wind-wave event from 4-8 November 2020 off the US west coast was examined, with a focus on the impacts of the event within an approximate 280x280 km central California coastal region covering the Bureau of Ocean Energy Management Morro Bay wind energy lease area. Simulations with both one-dimensional (1D; Yonsei University) and 3D PBL parameterizations were examined in this nest with ..delta..x=400 m. Two-way coupling was active, with near-surface winds feeding back to the wave model and bulk wave statistics feeding back to the atmospheric model. Both simulations compared favorably with buoy observations in capturing the timing and magnitude of wind speed, temperature, dewpoint, and significant wave height, as the front associated with the maritime weather system moved southward across coastal California. However, wind speed errors over land were larger. Time series of the vertical profile of winds below z=250 m from the simulations compared favorably with observations from the US Dept. of Energy Morro Bay Doppler lidar buoy. Differences between the coupled 1D and 3D PBL simulations were minor. The most notable difference was that the simulation using the 3D PBL parameterization had approximately 10 % weaker winds at the peak of the event causing 10 % lower significant wave heights. This difference was shown to be mostly due to differences in the vertical mixing treatment between the parameterizations, in particular the nonlocal downward mixing of higher momentum air in the 1D Yonsei University parameterization in convective conditions. Overall, this work demonstrates that the 3D PBL parameterization can be used in a coupled atmosphere/wave modeling framework with similar behaviors as traditional PBL parameterizations that do not provide horizontal turbulent variances and fluxes.

16 TIDAL AND WAVE POWER↗

Power Electronics Materials and Bonded Interfaces - Reliability and Lifetime

Advanced packaging technologies are currently being designed and developed by the power electronics industry however, the maximum operating temperature is still limited to 175 degrees Celsius for the silicon carbide devices. Bonded materials such as sintered copper and polymeric materials are potential candidates for high temperature operation, but it is critical to characterize and evaluate its reliability under harsh operating conditions. In this project, we discuss the results of the accelerated experiments conducted on sintered copper and polymeric materials. Additionally, a novel framework to develop the lifetime prediction model of bonded interfaces through employing statistical and machine learning models are described. In this task, scanning acoustic microscope images of bonded interfaces obtained under thermal cycling experiments are used as the data.

ENGINEERING↗

Unified description of the coupled-channels and statistical Hauser-Feshbach nuclear reaction theories for low energy neutron incident reactions

We incorporate the coupled-channels optical model into the statistical Hauser-Feshbach nuclear reaction theory, where the scattering matrix is diagonalized by performing the Engelbrecht-Weidenmüller transformation. This technique has been implemented in the coupled-channels optical model code ECIS by J. Raynal, and we extend this method so that all the open channels in a nucleon-induced reaction on a deformed nucleus can be calculated consistently.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of Thermal Radiation under Pressurized Oxy-combustion Conditions

Thermal radiation of the gaseous and particle phases in a pilot-scale pressurized oxy-combustor is computationally studied. In particular, the radiation characteristics of gases and particles are estimated by employing the statistical narrow-band model and the large-particle model. It is found that thermal radiation of the particle cloud dominates in the combustor under a furnace temperature of 1500 K and when there is no substantial loss of particles to the walls. Another important observation is that radiation from the gas and particles can be approximately treated as a graybody under these conditions. More specifically, the results on the spectral radiation intensity of a gas comprising 40% (vol) H 2 O and 60% CO 2 show that when the pressure is increased to 15 bar, and the radiation pathlength is 100 cm, the spectral radiation profile of the gas phase approaches that of a blackbody at the respective temperature. In addition, the emissivity of the particulate cloud has been evaluated as a function of the particle concentration and diameter by employing the large-particle model. It is shown that the emissivity grows with the particle concentration but decreases with the particle size for the same mass of the particles. Finally, this outcome of the present study is expected to be used to validate the assumption of the gray-gas model adopted in the numerical simulations of pressurized oxy-combustion.

large-particle model↗