Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Developing Model Benchtop Systems for Microbial Experimental Evolution

Understanding how microbes impact an ecosystem has improved through advances of molecular and genetic tools, but creating complex systems that emulate natural biology goes beyond current technology. In fact, many chemical, biological, and metabolic pathways of even model organisms are still poorly characterized. Even then, standard laboratory techniques for testing microbial impact on environmental change can have many drawbacks; they are time-consuming, labor intensive, and are at risk of contamination. By having an automated process, many of these problems can be reduced or even eliminated. We are developing a benchtop system that can run for long periods of time without the need for human intervention, involve multiple environmental stressors at once, perform real-time adjustments of stressor exposure based on current state of the population, and minimize contamination risks. Our prototype device allows operators to generate an analogue of real world micro-scale ecosystems that can be used to model the effects of disruptive environmental change on microbial ecosystems. It comprises of electronics, mechatronics, and fluidics based systems to control, measure, and evaluate the before and after state of microbial cultures from exposure to environmental stressors. Currently, it uses four parallel growth chambers to perform tests on liquid cultures. To measure the population state, optical sensors (LED/photodiode) are used. Its primary selection pressure is UV-C radiation, a well-studied stressor known for its cell- and DNA-damaging effects and as a mutagen. Future work will involve improving the current growth chambers, as well as implementing additional sensors and environmental stressors into the system. Full integration of multiple culture testing will allow inter-culture comparisons. Besides the temperature and OD sensors, other types of sensors can be integrated such as conductivity, biomass, pH, and dissolved gasses such as CO and O. Additional environmental stressor systems like temperature (extreme heat or cold), metal toxicity, and other forms of radiation will increase the scale and testing range.

Developing↗

High-Performance Spaceflight Computing (HPSC) Middleware Overview

High Performance Spacecraft Computing (HPSC) is a joint project between the National Aeronautics and Space Administration (NASA) and Air Force Research Lab (AFRL) to develop a high-performance multi-core radiation hardened flight processor. HPSC offers a new flight computing architecture to meet the needs of NASA missions through 2030 and beyond. Providing on the order of 100X the computational capacity of current flight processors for the same amount of power, the multicore architecture of the HPSC processor, or "Chiplet" provides unprecedented flexibility in a flight computing system by enabling the operating point to be set dynamically, trading among needs for computational performance, energy management and fault tolerance. The HPSC Chiplet is being developed by Boeing under contract to NASA, and is expected to provide prototypes in 2021. The HPSC Chiplet prototypes will be delivered with an evaluation board, system emulators, comprehensive system software, and a software development kit. In addition to the vendor deliverables, the AFRL is funding the development of a flexible Middleware to be developed by NASA Jet Propulsion Laboratory and NASA Goddard Space Flight Center. The HPSC Middleware provides a suite of thirteen high level services to manage the compute, memory and I/O resources of this complex device.This presentation will provide an overview of the HPSC project, including a hardware overview, system software overview, Middleware overview, and mission use cases. The hardware overview will provide a look at the 8 core High Performance Processing Subsystem (HPPS), the Real Time Processing Subsystem (RTPS), the Chiplet Configuration Management Subsystem, on chip peripherals, and high speed I/O. The system software overview will introduce the boot loaders, operating systems, device drivers, and software development environment. The Middleware overview will provide insight into the high-level services that will be provided to help mission developers manage the many resources and configurations made possible with the Chiplet. Finally, the presentation will provide a brief look at the mission use cases that can be enabled with this next generation architecture.

middleware↗

Performance and Radiation Tolerance of InAs/GaSb LWIR Detectors Based on CBIRD Design

We report our recent developments of antimonide based infrared photodetectors utilizing a complementary barrier infrared detector (CBIRD) design. The new generation of devices can operate close to zero bias with the same quantum efficiency as the initial design. 320x256 pixel long-wavelength infrared focal plane arrays utilizing optimized design have been demonstrated with 8.8 µm cutoff wavelength and noise equivalent differential temperature of 26 mK at operating temperature of 80 K for 300 K background and f/2 optics. As CBIRD detectors became valuable candidates for space-based instruments, question of their radiation tolerance became important. Here, we report our investigations of the proton irradiation effects on the photodetector performance.

heterostructure↗

Enhanced quantum efficiency of high-purity silicon imaging detectors by ultralow temperature surface modification using Sb doping

A low temperature process for Sb doping of silicon has been developed as a backsurface treatment for high-purity n-type imaging detectors. Molecular beam epitaxy (MBE) is used to achieve very high dopant incorporation in a thin, surface-confined layer. The growth temperature is kept below 450 °C for compatibility with Al-metallized devices. Imaging with MBE-modified 1kx1k charge coupled devices ((CCDs) operated in full depletion has been demonstrated. Dark current is comparable to the state-of-the-art process, which requires a high temperature step. Quantum efficiency is improved, especially in the UV, for thin doped layers placed closer to the backsurface. Near 100% internal quantum efficiency has been demonstrated in the ultraviolet for a CCD with a 1.5 nm silicon cap layer.

Nikzad, Shouleh↗

Experiences in the Development of the Mighty Worm

The field of adaptive structures has expanded dramatically during the past few years. Inch worm actuators are commercially available, but do not meet all the desired static and dynamic features in one actuator. The objective of the development of the Mighty Worm was to develop such an actuator. The Mighty Work actuator consists of a piezoelectric transducer, its housing, and two clamping devices. In operation, Mighty Worm either pushes or pulls a load.

actuators↗

Evaluation of asynchronous geiger-mode avalanche photodiode arrays for deep-space optical communications

The NASA Psyche mission is set to explore an asteroid located between Mars and Jupiter with a launch date in 2022. On-board the Psyche spacecraft is experimental demonstrator technology that will allow scientists to explore the capabilities of optical communications – a program called Deep Space Optical Communication (DSOC) led by Jet Propulsion Laboratory (JPL). DSOC seeks to improve communications performance by developing a space-based Flight Laser Transceiver (FLT) and a ground-based transceiver to enable photon-efficient communications with equipment in deep space. An integral part to this FLT system is a high-efficiency photon-counting camera (PCC) that is able to detect both the 1064nm uplink/beacon laser photons and 1550nm downlink laser photons with low background noise, and is capable of withstanding the rigors of space-travel. The paper details the characterization of several asynchronous Geiger-Mode Avalanche Photodiode (GmAPD) arrays developed by MIT Lincoln Laboratory for use in the PCC- specifically evaluating the temperature dependence of background noise, photon detection efficiency at 1064nm and 1550nm wavelengths, pixel lifetime testing, and angle of acceptance measurements. The results of this characterization are used to determine the nominal conditions for the device to operate in while in flight to maintain an efficient link with the ground-based transceiver.

Duerr, E.↗

Spectral Measurement Errors due to CCD Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a hyperspectral imager with a spatial resolution of 1km x 1km and spectral resolution of 5nm in 2.5nm steps over 320-890nm. The detection system is based on two Charge-Coupled Devices (CCDs) operating in Time Delay Integration (TDI) mode to achieve high signal-to-noise ratio. The front-end optical imager is a rotating mirror-based system that images the ground-scene onto a slit with a field of view of 16km x 1km. The slit-image is re-imaged and wavelength dispersed on the CCDs. As the ground-scene moves through the slit, it moves along the CCD columns as charge is moved along with it. The accumulated charge at the end of each column is collected in a serial pixel. Each of the 16 CCD outputs read out 32 columns of the same ground scene spaced 0.625nm apart. The 32-pixel serial register is swiftly read out before the next TDI cycle. The telescope is spinning at 5.77Hz to achieve the required spatial resolution. This results in a serial pixel readout speed of 8.5MHz. Each serial read-cycle goes through a reset and video period that are each sampled to create a low-noise correlated double sample value. This only allows 59ns for the reset and video to be asserted and settled before sampling. Due to the short time period, the response of the CCD exhibits serial pixel-to-pixel readout interference as the reset and video signals do not have time to fully settle before sampling. Each serial pixel value therefore has a dependence on the value of the preceding pixel value. This leads to a spectral measurement error of up to 0.3%. We explain the operation of the detection system, the behavior of the interference and the resulting wavelength error with results from ground testing and on-orbit characterization.

Ulrik B Gliese↗

The Future of Renewable Energy Generation: Photovoltaic Materials

There are myriad ways to harness solar energy, including, but not limited to: solar thermal, solar fuels, and photovoltaics (PV). Across the portfolio of solar energy technologies, PV is unique in that collected photons are directly converted to electricity. Traditionally, the dominant materials in PV are also the dominant semiconductor and optoelectronic materials. The cost of solar energy from PV is a product of a complex combination of non-material related factors, known as soft costs, e.g., permitting, zoning, and of balance-of-systems (BOS) costs, like inverters or other components needed to utilize cells and modules. While the soft costs are due to administrative/regulatory concerns, BOS costs are driven by details of cell/module fabrication, mounting, power electronics, and other concerns, which touch on a range of basic material science issues. There is some overlap of BOS and soft cost, as a lighter weight solar panel can reduce installations costs, as an example. At the PV-system level, the materials considerations span both electronic and structural components. The focus of this paper is the solar cell, which is the minimum operational unit device that converts light into electricity.

30 DIRECT ENERGY CONVERSION↗

Power Electronics Materials and Bonded Interfaces - Reliability and Lifetime

Wide-bandgap devices have pushed the operational limit of semiconductor devices in automotive power electronics packages to higher temperatures (>200 C). While a higher efficiency can be achieved through the use of wide-bandgap devices, the entire package must be re-designed with components that can withstand the higher temperature limits. Sintered silver and transient liquid phase bonds are potential candidates as bonded materials for use in higher temperatures however, the underlying mechanics of deformation under thermal loads and the resulting failure mechanisms in these materials are not well understood. Accelerated experiments conducted at NREL reveal that high-lead solder joints have better reliability than sintered silver under extreme thermal cycling conditions. Furthermore, efforts to develop a crack propagation model for the high-temperature materials are described.

ADVANCED PROPULSION SYSTEMS↗

Bonded Interfaces for High-Temperature Power Electronics

Wide-bandgap devices have pushed the operational limit of semiconductor devices in automotive power electronics packages to higher temperatures (>200 degrees C). While a higher efficiency can be achieved through the use of wide-bandgap devices, the entire package must be re-designed with components that can withstand the higher temperature limits. Sintered silver and transient liquid phase bonds are potential candidates as bonded materials for use in higher temperatures however, the underlying mechanics of deformation under thermal loads and the resulting failure mechanisms in these materials are not well understood. Furthermore, thermomechanical modeling plays a key role in understanding the degradation behavior of bonded interface materials and for design optimization of power electronics packages.

ADVANCED PROPULSION SYSTEMS,DIRECT ENERGY CONVERSI↗

Ecosystem device for determining plant-microbe interactions

This disclosure provides systems, methods, and devices related to the study of ecological processes. In one aspect, a device includes a base, a substrate, and an enclosure. The substrate is in contact with a first surface of the base. The substrate and the base define a root chamber. The enclosure is in contact with a second surface of the base. The base and the enclosure define a growth chamber. The base defines a stem port connecting the root chamber and the growth chamber. The base further defines a first port in fluid communication with the root chamber and a second port in fluid communication with the root chamber. The device is operable to contain a plant, roots of the plant being in the root chamber, a stem of the plant passing through the stem port, and leaves of the plant being in the growth chamber.

Andeer, Peter↗

A Collaboration Website for Muon Catalyzed Fusion and Muon Beam Production

This research initiative establishes a dynamic online platform geared towards supporting the burgeoning Muon Catalyzed Fusion collaboration, focusing on the concurrent development of particle accelerators and transport beamlines for muon beams. The central feature of this endeavor is the creation of a multifaceted website comprising both public facing and private sections to cater to diverse user needs. The public segment is meticulously designed to serve as an educational hub, featuring information pages targeted at the general public alongside private pages exclusively accessible to collaboration members. These pages will host an array of multimedia elements, ranging from images and text animations to video lectures, covering an extensive spectrum of topics integral to the science of Muon Catalyzed Fusion. Encompassing areas such as Acceleration, Applications, Instrumentation, Beamline Design, and beam dynamics design codes, the educational content aims to make complex scientific concepts more accessible to a broader audience. Ensuring seamless accessibility across various devices and operating systems, the website incorporates integration with collaborative tools such as Google Docs for document collaboration, GitHub for code repository management, and WordPress for blogging with interactive commenting features. The bifurcation between public and private sections is a strategic approach to maintaining transparency while safeguarding proprietary research and works in progress. The public pages are strategically crafted to disseminate information, showcasing the latest endeavors and achievements within the NK Labs collaboration, including lectures, published papers, and regular blog posts open to public comments. On the other hand, the private section provides collaboration members with a secure space to share unpublished or nonpublic research, fostering collaborative efforts through integrated Google Docs and Python Plotty for shared graphing work. In essence, this ambitious project endeavors to bridge the gap between complex scientific knowledge and public understanding, enhance collaboration among researchers, and serve as a dynamic and inclusive platform for sharing and advancing the state-of-the-art in Muon Catalyzed Fusion and Accelerators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Introducing the Baseline Performance Reference (BPR) for Irradiance in PV System Applications

Photovoltaic (PV) reference cells, modules, and arrays respond in a complex manner to the many variables that define their operating environment. PV reference cells for irradiance measurement have similarities but also differences to operational PV modules. For this reason, a more neutral and a well-defined generic PV reference cell is needed, whose characteristics are close enough to most operational PV devices to make stable performance indicators possible but whose characteristics are not necessarily identical to any of them. This poster describes a new well-defined reference quantity for outdoor PV measurements, called the baseline performance reference (BPR).

baseline performance reference↗

A Cybersecurity Testbed for Smart Buildings

Smart buildings are equipped with a plethora of cyber-physical systems, such as Internet of Things (IoT) devices and building automation systems. These devices, especially in commercial buildings, use legacy communications and hardware that were not designed with cybersecurity in mind. With increasing cyber threats in recent years, smart buildings have become an increasing target for attacks, but not enough published data are available from these incidents to study or replicate the scenarios to defend buildings. As part of the U.S. Department of Energy-funded project focusing on developing the Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS) platform, we developed a cybersecurity test bed for smart buildings. This test bed includes a building simulation tool, virtual devices, emulated operational technology networks, and remote hardware-in-the-loop. Using this test bed, we performed different cyberattacks on the smart building model and collected both physical building data, to understand the impacts on the building, and network data, to aid in separating mechanical faults from cyberattacks during the detection. This test bed is a significant tool in protecting smart buildings from cyberattacks because it can aid in both cybersecurity analysis and the evaluation of other cyberattack detection tools by testing the tools in a secure environment without impacting the building operations.

cyber-physical systems↗

A Cybersecurity Testbed for Smart Buildings

Smart buildings are equipped with a plethora of cyber-physical systems, such as Internet of Things (IoT) devices and building automation systems. These devices, especially in commercial buildings, use legacy communications and hardware that were not designed with cybersecurity in mind. With increasing cyber threats in recent years, smart buildings have become an increasing target for attacks, but not enough published data are available from these incidents to study or replicate the scenarios to defend buildings. As part of the U.S. Department of Energy-funded project focusing on developing the Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS) platform, we developed a cybersecurity test bed for smart buildings. This test bed includes a building simulation tool, virtual devices, emulated operational technology networks, and remote hardware-in-the-loop. Using this test bed, we performed different cyberattacks on the smart building model and collected both physical building data, to understand the impacts on the building, and network data, to aid in separating mechanical faults from cyberattacks during the detection. This test bed is a significant tool in protecting smart buildings from cyberattacks because they can aid in both cybersecurity analysis and the evaluation of cyberattack detection tools by testing the tools in a secure environment without impacting the building operations.

alfalfa↗

Automated control of microfluidic devices based on machine learning

A system is provided to automatically monitor and control the operation of a microfluidic device using machine learning technology. The system receives images of a channel of a microfluidic device collected by a camera during operation of the microfluidic device. Upon receiving an image, the system applies a classifier to the image to classify the operation of the microfluidic device as normal, in which no adjustment to the operation is needed, or as abnormal, in which an adjustment to the operation is needed. When an image is classified as normal, the system may make no adjustment to the microfluidic device. If, however, an image is classified as abnormal, the system may output an indication that the operation is abnormal, output an indication of a needed adjustment, or control the microfluidic device to make the needed adjustment.

Giera, Brian↗

Preparation for an Earth Independent Medical Operations Demonstration using the Tempus ALS™ Medical Device

NASA’s exploration-class missions have severe resource constraints, long return trip durations, significant communication delays and limited resupply opportunities. Validation on the International Space Station (ISS) of medical devices that fit within Earth-Independent Medical Operations (EIMO) systems is a necessary preparation step. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. The Human Research Program’s (HRP) Exploration Medical Capability (ExMC) Element and the Exploration Medical Integrated Product Team (XM-IPT) are planning an ISS technology demonstration to determine the feasibility of including a multifunctional medical device into an EIMO medical system. Demonstration Preparations: The Tempus ALS (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) is a commercial-off-the-shelf medical device, with United States Food and Drug Administration clearance and is Conformité Européene marked in Europe. Several thousand units have been sold and are successfully operating in pre-hospital and in remote settings, such as by European Space Agency (ESA) flight surgeons and some of NASA’s commercial partners during post-flight medical operations. The Tempus ALS provides vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature. The device has ultrasound imaging and video laryngoscopy capabilities and has automatic or manual defibrillation modes for treating cardiac arrhythmias. It includes procedural guidance capabilities to assist in the collection of the vital sign measurements and it has various data transmission and report generation features. NASA’s HRP ExMC and XM-IPT are partnering with the ESA to demonstrate the Tempus ALS on ISS, with ESA manifesting the Tempus ALS and its accessories. ESA will compare performance of periodic health status exams and medical contingency drills performed nominally and with the Tempus ALS. NASA’s EIMO demonstration will include the use of Tempus ALS to diagnose a complaint of abdominal pain under increasingly independent circumstances. The caregiver must assess the present illness, collect vital sign measurements, and perform an abdominal ultrasound, under one of three communication situations, including real-time, with a several second delay and with a delay on the order of minutes. Expected Outcomes: Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis instead of separate devices with singular functionalities. Information will also be collected about performance differences as communication delays increase and available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities which takes the EIMO construct into consideration.

Beth Lewandowski↗

A tri-state optical switch for local area network communications

This novel structure is a heterojunction phototransistor which can be used as an emitter-detector, and when placed in a quiescent mode, the device becomes a passive transmitter. By varying the voltage bias, this novel device will switch between all three modes of operation. Such a device has broad application in network environments with operation speeds of less than 50 MHz and distances of less than 1 km, e.g. automobiles, airplanes, and intra-instrumentation. During this period, the emission mode for this device was studied and mathematically modeled.

Simms, Garfield↗