Bridging Data and Models: Advancing Aerosol, Cloud, and Convection Representation in Earth System Models (ESMs)
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The Tank Closure and Technology Development Groups are developing a strategy for closing the High Level Waste (HLW) tanks at the Savannah River Site (SRS). Two Type IV tanks, 17 and 20 in the F-Area Tank Farm, have been successfully filled with grout. Type IV tanks at SRS do not contain cooling coils; on the other hand, the majority of the tanks (Type I, II, III and IIIA) do contain cooling coils. The current concept for closing tanks equipped with cooling coils is to pump grout into the cooling coils to prevent pathways for infiltrating water after tank closure. This task addresses the use of grout to fill intact cooling coils present in most of the remaining HLW tanks on Site. The overall task was divided into two phases. Phase 1 focused on the development of a grout formulation (mix design) suitable for filling the HLW tank cooling coils. Phase 2 will be a large-scale demonstration of the filling of simulated cooling coils under field conditions using the cooling coil grout mix design recommended from Phase 1. This report summarizes the results of Phase 1, the development of the cooling coil grout formulation. A grout formulation is recommended for the full scale testing at Clemson Environmental Technology Laboratory (CETL) that is composed by mass of 90% Masterflow (MF) 816 (a commercially available cable grout) and 10% blast furnace slag, with a water to cementitious material (MF 816 + slag) ratio of 0.33. This formulation produces a grout that meets the fresh and cured grout requirements detailed in the Task Technical Plan (2). The grout showed excellent workability under continuous mixing with minimal change in rheology. An alternative formulation using 90% MF 1341 and 10% blast furnace slag with a water to cementitious material ratio of 0.29 is also acceptable and generates less heat per gram than the MF 816 plus slag mix. However this MF 1341 mix has a higher plastic viscosity than the MF 816 mix due to the presence of sand in the MF 1341 cable grout and a lower water to solids ratio. Nevertheless, the higher viscosity grout may still meet the requirements for the cooling coil grout under certain pumping conditions or alternatively, the mix may be made more fluid by a short period of high shear mixing during production. The mixes have not been optimized for large scale production. It may be possible, for example, to adjust the water to cementitious materials ratio to provide improved performance of these mixes based on the results and conclusions of the large scale testing at CETL. Recommendations from this task include incorporation of a backup mixing/pumping system that is either integrated into the system or is available for immediate use in case of a pump or mixer failure of the primary system. A second recommendation is to conduct a laboratory scale investigation to determine the impact of operational variation on the properties of the grout. This effort would be initiated after feedback is received from the large scale testing at CETL. The purpose of this proposed variability testing is to better understand the limits of the operational variations (such as temperature and mixing time), and to identify possible approaches for remediation to ensure that the grout produced will flow effectively in the coils while still meeting the performance requirements.
As part of its Resource Conservation and Recovery Act (RCRA) Corrective Action Program (CAP), the Lawrence Berkeley National Laboratory (LBNL) Environmental Restoration Program conducted an evaluation of naturally occurring metals in soils at the facility. The purpose of the evaluation was to provide a basis for determining if soils at specific locations contained elevated concentrations of metals relative to ambient conditions. Ambient conditions (sometimes referred to as 'local background') are defined as concentrations of metals in the vicinity of a site, but which are unaffected by site-related activities (Cal-EPA 1997). Local background concentrations of 17 metals were initially estimated by LBNL using data from 498 soil samples collected from borings made during the construction of 71 groundwater monitoring wells (LBNL 1995). These concentration values were estimated using the United States Environmental Protection Agency's (USEPA's) guidance that was available at that time (USEPA 1989). Since that time, many more soil samples were collected and analyzed for metals by the Environmental Restoration Program. In addition, the California Environmental Protection Agency (Cal-EPA) subsequently published a recommended approach for calculating background concentrations of metals at hazardous waste sites and permitted facilities (Cal-EPA 1997). This more recent approach differs from that recommended by the USEPA and used initially by LBNL (LBNL 2002). The purpose of the 2002 report was to apply the recommended Cal-EPA procedure to the expanded data set for metals that was available at LBNL. This revision to the 2002 report has been updated to include more rigorous tests of normality, revisions to the statistical methods used for some metals based on the results of the normality tests, and consideration of the depth-dependence of some sample results. As a result of these modifications, estimated background concentrations for some metals have been slightly revised from those presented in the original 2002 report. In cases where estimated background concentrations were reduced, site data were reviewed to assess whether significant changes to results of the RCRA CAP findings would result. This assessment indicated that no significant changes in RCRA CAP findings would result from the revisions.
The overall goals of the Tank Farm Vadose Zone Project, led by Washington River Protection Solutions, are to define risks from past and future single-shell tank farm activities; identify and evaluate the efficacy of interim measures; and aid, via collection of geochemical information and data, the future decisions that must be made by the U.S. Department of Energy (DOE) regarding the near-term operations, future waste retrieval, and final closure activities for the single-shell tank waste management areas (WMAs). To meet the investigative goals of the Tank Farm Vadose Zone Project, the Environmental Sciences Laboratory performed geochemical analyses on vadose zone sediments collected within Waste Management Area C. Tier one analyses of UPR-200-E-86, which includes direct push probe holes C5952, C5958 and C5960, were performed between 3/25/08 and 4/14/08. Preliminary results were presented to CH2M Hill Hanford Group on 6/5/08. As a result of the tier one investigations, further tier two analyses were requested. Tier two investigations include particle size and mineralogy analyses on samples collected between 80 to 120 feet below ground surface that were found to contain high concentrations of chloride and sulfate. Tier one analyses on sediments retrieved near UPR-200-E-81, direct push probe hole C6394, were performed between 6/20/08 and 7/22/08. Preliminary results of the tier one analyses were presented on 8/15/08. As a result of the tier one investigations, further tier two analyses were requested. Tier two analyses include determining whether U-236 exists in samples at approximately 42 feet below the ground surface. Confirmation of U-236 will determine whether the U-238 seen in the leaches performed on samples at that depth is a result of contamination and not from leaching natural uranium. Using the water and acid extract U-238 concentrations from the tier one analysis, equilibrium Kd values were requested to be calculated. Additional tier two analysis includes particle size analysis on samples collected at approximately 135 feet below ground surface to investigate a moist layer containing high chloride and sulfate anion concentrations. Particle size analysis was also requested for a sample collected at approximately 42 feet below ground surface due to its high moisture content and nitrate concentrations. The ESL was also requested to examine Paleosols to determine where the paleosols from the Integrated Disposal Facility would extrapolate to in WMA C.
Low clouds and precipitation representation remain a major source of uncertainty in Earth System Models (ESMs), particularly due to challenges in representing their sub-grid variability and scale-dependent sampling. This study evaluates the performance of preliminary simulations from the Large-Eddy Simulation (LES) ARM Symbiotic Simulation and Observation (LASSO) project over the Eastern North Atlantic (ENA), with a focus on liquid water path (LWP), ice water path (IWP), cloud fraction (CF), and surface precipitation simulated across closed-cell, open-cell, and transitional cloud regimes. Using LES (100 m horizontal grid spacing) driven by ERA5 and MERRA-2 reanalyses, we assess the representativeness of ground-based point observations by analyzing their correspondence to model-resolved spatial and temporal means. Results suggest that observational sampling of at least 6 hours is required to achieve consistency with domain-scale averages, in particular for observations that exhibit pronounced sub-grid heterogeneity, such as precipitation. ERA5-forced simulations exhibit improved spatial coherence and agreement with domain-averaged quantities when compared to MERRA-2 runs, with performance discrepancies largest for convective cloud conditions due to differences in forcing fidelity and temporal resolution. These findings highlight the importance of regime-aware model evaluation strategies and potentially demonstrate how LES can inform observation-model comparison practices and the development of cloud and precipitation parameterizations in ESMs.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Space exploration programs and space science summary on Mariner, Ranger, and Surveyor projects - deep space instrumentation facility - environmental test facility
Simulation techniques as means of acquiring information on ionizing particle radiation effect
Chronic exposure of rats to gaseous environments of varied composition and pressure, noting exposure capsules, gas flow system, respiratory gas analyzer, etc
Cryogenic liquid reclamation system is used as an add-on unit to the nitrogen system of environmental test laboratories to salvage liquid nitrogen presently being treated as waste. The system may be installed indoors or outdoors provided the gas boiled off from the cryogenic liquid is vented to the outside.
Wind tunnels and hypervelocity laboratory for environmental simulation testing studies
Environmental simulation facilities, biplanar optical systems for nonplanar free flight tests, hypersonic boom and air radiation measurements, and X-15 and wedge wake studies
A method of synthesizing an arbitrarily shaped transient time pulse on vibration exciters is described. The transient waveform control technique is based on recent developments in digital time series analysis, the real-time FFT processor. A brief description of the theory, error estimates and hardware/software implementation to the JPL Dynamic Environmental Testing Laboratory is presented.
The space-research capabilities of the Space Shuttle System are assessed in a review of its systems and instrumentation, visualizing the beginning of a new era for science in space with the start of shuttle operations expected in 1979. The Shuttle parameters are listed and the Large Space Telescope and the Plasma Physics and Environmental Perturbation Laboratory of the Shuttle are described. The Shuttle-based research in astronomy, atmospheric and space physics, high-energy astrophysics, and relativity is discussed. The versatile capabilities of the Shuttle as a plasma laboratory, a source of perturbation, and observing platform, and a particle precipitator are noted.
The participation of the Environmental Physiology Laboratory (EPL) in the general purpose laboratory concept verification test 3 is documented. The EPL Monkey-Pod Experiment was designed to incorporate a 10-12 kg, pig tailed monkey, Macaca nemestrina, into the pod and measure the physiological responses of the animal continuously. Four major elements comprise the EPL Monkey-Pod Experiment System: (1) a fiberglass pod containing the instrumented monkey plus feeder and watering devices, (2) an inner console containing the SKYLAB mass spectrometer with its associated valving and electronic controls, sensing, control and monitoring units for lower body negative pressure, feeder activity, waterer activity, temperatures, and gas metabolism calibration, (3) an umbilical complex comprising gas flow lines and electrical cabling between the inner and outer console and (4) an outer console in principle representing the experiment support to be provided from general spacecraft sources.
The participation of the Environmental Physiology Laboratory (EPL) in the general purpose laboratory concept verification test 3 is documented. The EPL Monkey-Pod Experiment was designed to incorporate a 10-12 kg, pig tailed monkey, Macaca nemestrina, into the pod and measure the physiological responses of the animal continously. Four major elements comprise the EPL Monkey-Pod Experiment System: (1) a fiberglass pod containing the instrumented monkey plus feeder and watering devices, (2) an inner console containing the SKYLAB mass spectrometer with its associated valving and electronic controls, sensing, control and monitoring units for lower body negative pressure, feeder activity, waterer activity, temperatures, and gas metabolism calibration, (3) an umbilical complex comprising gas flow lines and electrical cabling between the inner and outer console and (4) an outer console in principle representing the experiment support to be provided from general space craft sources.