The application of a time-domain deconvolution technique for identification of experimental acoustic-emission signals

A method is presented for the signature analysis of pulses by reconstructing in the time domain the shape of the pulse prior to its passing through the measurement system. This deconvolution technique is first evaluated using an idealized system and analytical pulse models and is shown to provide improved results. An experimental situation is then treated; system-component models are developed for the digitizer, tape recorder, filter, transducer and mechanical structure. To accommodate both calibration results and manufacturer's data, and to provide stable mathematical models entails considerable effort: some 30 parameters must be identified to model this system - which is still a substantial approximation - albeit of very high order. Experimental pulses generated by a ball drop, spark discharge and a tearing crack are then deconvoluted 'back through' the system as modeled, using this technique. These results are compared and indicate (a) that consistent shapes may be expected from a given type of source and (b) that some sources can be identified with greater clarity using the deconvolution approach.

Houghton, J. R.↗

Induced shock pulse testing by transient waveform control

A method of synthesizing an arbitrarily shaped transient time pulse on vibration exciters is described. The transient waveform control technique is based on recent developments in digital time series analysis, the real-time FFT processor. A brief description of the theory, error estimates and hardware/software implementation to the JPL Dynamic Environmental Testing Laboratory is presented.

Kim, B. K.↗

Long-Lag, Wide-pulse Gamma-Ray Bursts

Currently, the best available probe of the early phase of gamma-ray burst (GRB) jet attributes is the prompt gamma-ray emission, in which several intrinsic and extrinsic variables determine GRB pulse evolution. Bright, usually complex bursts have many narrow pulses that are difficult to model due to overlap. However, the relatively simple, long spectral lag, wide-pulse bursts may have simpler physics and are easier to model. In this work we analyze the temporal and spectral behavior of wide pulses in 24 long-lag bursts, using a pulse model with two shape parameters - width and asymmetry - and the Band spectral model with three shape parameters. We find that pulses in long-lag bursts are distinguished both temporally and spectrally from those in bright bursts: the pulses in long spectral lag bursts are few in number, and approximately 100 times wider (10s of seconds), have systematically lower peaks in vF(v), harder low-energy spectra and softer high-energy spectra. We find that these five pulse descriptors are essentially uncorrelated for our long-lag sample, suggesting that at least approximately 5 parameters are needed to model burst temporal and spectral behavior. However, pulse width is strongly correlated with spectral lag; hence these two parameters may be viewed as mutual surrogates. We infer that accurate formulations for estimating GRB luminosity and total energy will depend on several gamma-ray attributes, at least for long-lag bursts. The prevalence of long-lag bursts near the BATSE trigger threshold, their predominantly low vF(v) spectral peaks, and relatively steep upper power-law spectral indices indicate that Swift will detect many such bursts.

Norris, J. P.↗

Long-Lag, Wide-pulse Gamma-Ray Bursts

The best available probe of the early phase of gamma-ray burst (GRB) jet attributes is the prompt gamma-ray emission, in which several intrinsic and extrinsic variables determine observed GRB pulse evolution, including at least: jet opening angle, profiles of Lorentz factor and matter/field density, distance of emission region from central source, and viewing angle. Bright, usually complex bursts have many narrow pulses that are difficult to model due to overlap. However, the relatively simple, long spectral lag, wide-pulse bursts may have simpler physics and are easier to model. We have analyzed the temporal and spectral behavior of wide pulses in 24 long-lag bursts from the BATSE sample, using a pulse model with two shape parameters - width and asymmetry - and the Band spectral model with three shape parameters. We find that pulses in long-lag bursts are distinguished both temporally and spectrally from those in bright bursts: the pulses in long spectral lag bursts are few in number, and approximately 100 times wider (10s of seconds), have systemtically lower peaks in nu*F(nu), harder low-energy spectra and softer high-energy spectra. These five pulse descriptors are essentially uncorrelated for our long-lag sample, suggesting that at least approximately 5 parameters are needed to model burst temporal and spectral behavior, roughly commensurate with the theoretical phase space. However, we do find that pulse width is strongly correlated with spectral lag; hence these two parameters may be viewed as mutual surrogates. The prevalence of long-lag bursts near the BATSE trigger threshold, their predominantly low nu*F(nu) spectral peaks, and relatively steep upper power-law spectral indices indicate that Swiift will detect many such bursts.

Norris, J. P.↗

Surface Change Detection Using Large Footprint Laser Altimetry

Laser altimeters provide a precise and accurate method for mapping topography at fine horizontal and vertical scales. A laser altimeter provides range by measuring the roundtrip flight time of a short pulse of laser light from the laser altimeter instrument to the target surface. The range is then combined with laser beam pointing knowledge and absolute position knowledge to provide an absolute measurement of the surface topography. Newer generations of laser altimeters measure the range by recording the shape and time of the outgoing and received laser pulses. The shape of the return pulse can also provide unique information about the vertical structure of material such as vegetation within each laser footprint. Distortion of the return pulse is caused by the time-distributed reflections adding together and representing the vertical distribution of surfaces within the footprint. Larger footprints (10 - 100m in diameter) can support numerous target surfaces and thus provide the potential for producing complex return pulses. Interpreting the return pulse from laser altimeters has evolved from simple timing between thresholds, range-walk corrections, constant-fraction discriminators, and multi-stop time interval units to actual recording of the time varying return pulse intensity - the return waveform. Interpreting the waveform can be as simple as digitally thresholding the return pulse, calculating a centroid, to fitting one or more gaussian pulse-shapes to the signal. What we present here is a new technique for using the raw recorded return pulse as a raw observation to detect centimeter-level vertical topographic change using large footprint airborne and spaceborne laser altimetry. We use the correlation of waveforms from coincident footprints as an indication of the similarity in structure of the waveforms from epoch to epoch, and assume that low correlation is an indicator of vertical structure or elevation change. Thus, using vertically and horizontally geolocated waveforms as raw observables (i.e., waveforms tied to a common reference ellipsoid), we assess whether epoch-to-epoch vertical ground motion results in a decrease in the correlation of coincident waveforms over time, and whether this can be used to quantify the magnitude of the deformation. Results of computer models and an example over an area of eroded beachfront will be presented.

Blair, J. Bryan↗

Proportional counters as low energy photon detectors

We investigated the response of an argon-methane proportional counter to monochromatic X-rays in the range 99 to 277 eV. The apparent nonlinearities in mean pulse height as a function of photon energy and the detailed shape of the pulse height distribution for each energy can be predicted quite precisely using the extensive atomic data available for argon. Based on this understanding, we propose a semi-empirical system for using a limited amount of calibration data to predict the full response of counters employing less well-characterized gases. Such accurate models of proportional counters are required to maximize the spectral information that can be derived from observed pulse height distributions.

Jahoda, Keith↗

Surface micro-discharges on spacecraft dielectrics

Extensive measurements on Teflon and Kapton in a scanning electron microscope indicate the existence of a well-defined family of surface micro-discharges characteristic of the dielectric material. For a given small region exposed to the 16-20 kV electron beam, the strongest discharge pulses are similar in shape and amplitude. For Teflon, typical pulse durations are 2-3 ns, rise and fall times are sometimes as low as 0.2 ns, current amplitudes are approximately 100 mA flowing down to the pedestal and the pulses are unidirectional with no ringing. The use of a rapid-scan electron microscope with a secondary-electron imaging system reveals complex charge distributions resembling Lichtenberg figures on a supposedly flat homogeneous dielectric surface. These patterns undergo extensive alteration at each micro-discharge pulse and indicate that both the charging and discharging processes are highly nonuniform over the dielectric surface. The use of floodbeam causes the occurrence of a large-scale macro-discharges, in which a typical peak current is 40 A with a duration of 120 ns.

Balmain, K. G.↗

Spatio-temporally shaped deep UV laser source for ultrabright photocathodes using novel upconversion techniques (Final Report)

The goal of this project was to take a VUV laser system designed by Kapteyn-Murnane Labs (KMLabs)—the Hyperion VUV, and increase its functionality, efficiency, and applicability by further probing the fundamental physics taking place in the system and optimizing the system performance. More specifically, DOE accelerator applications—particularly for XFELs that require low-emittance electron beams, require precisely controlled ultrashort pulses in the deep-UV at 250-260 nm to drive the photocathode electron source. This is conventionally done using an ultrafast infrared laser, with subsequent stages of nonlinear upconversion in solid-state nonlinear-optical crystal media (principally BBO, which is commonly used for UV upconversion). However, maintaining high spatial mode beam quality, as well as precisely controlled temporal profile, has proven a persistent challenge. As a possible alternative to this approach, KMLabs has demonstrated a system that generates vacuum ultraviolet light (VUV) by upconverting pulses from an infrared ultrafast laser in a gas-filled hollow waveguide, driving a process of highly cascaded harmonic generation (HCHG). Because HCHG upconversion is done in a gas, rather than a solid, at high intensity in a guided-wave geometry, it retains an excellent beam spatial profile as well as a large spectral bandwidth that allows for control over the temperal structure of the pulse. A challenge, however, is in energy scaling of this HCHG technique to the ~1-20 μJ pulses required for photocathode applications. To-date, the pulse energies used in published HCHG work are sub-10-nJ. This project proposed to explore ways to generate higher-energy pulses using HCHG, as well as to investigate spectral and temporal shaping of the deep UV pulses by pulse shaping the infrared laser used to seed the process. Although we showed that our approach works for generating light at 259 nm, the total pulse energy achieved seems limited to approximately the same value as past work. However, the techniques we investigated may well have benefits for extending this source to much shorter wavelength output.

43 PARTICLE ACCELERATORS↗

Novel Hot-Spot Ignition Designs for Inertial Confinement Fusion with Liquid-Deuterium-Tritium Spheres

A new class of ignition designs is proposed for inertial confinement fusion (ICF) experiments. These designs are based on the hot-spot-ignition approach, but instead of conventional targets that comprise of spherical shells with thin frozen deuterium{tritium (DT) layers, homogeneous-density (solid or liquid) DT spheres are used where the lower-density central region and higher-density shell are created dynamically by appropriately shaping the laser pulse. These offer several advantages, including simplicity in target production and lower sensitivity to both laser imprint and physics uncertainty in shock interaction with the ice-vapor interface. The design evolution starts by launching an ~1-Mbar shock into a homogeneous DT sphere. After bouncing from the center, the reflected shock reaches the outer surface of the sphere and the shocked material starts to expand outward until its pressure drops below the ablation pressure. At this point, an adjustment shock is launched inward by supporting ablation pressure. This shock compresses the ablator and fuel, forming a shell. The shell is then accelerated and compressed by appropriately shaping the drive laser pulse, similar to the conventional thin-shell, hot-spot designs. Here, this paper demonstrates the feasibility of the new concept using hydrodynamic simulations and discusses the advantages and disadvantages of the concept compared with more-traditional ICF designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The structure of lightning flashes HF-UHF: 12 September 1975, Atlanta, Georgia

Simultaneous measurement of sferics at 3, 30, 139, and 295 MHz were made during thunderstorms. Wideband electronics and an analogue tape recorder continuously recorded the radiation from lightning with about 300 kHz of bandwidth. The data were obtained during the passage of a cold front. Flashing rate, burst rate and the structure of individual flashes were recorded. The record of a typical flash begins with a sudden burst of closely spaced pulses whose temporal structure is typical of the stepped leader, and ends in a large pulse suggestive of a first return stroke. The remainder of the flash consists of a sequence of pulses of varying amplitude separated by quiet periods of the order of milliseconds. The shape of these pulses and the temporal structure suggest that the first few large pulses are return strokes. Other discharges begin with widely spaced discrete pulses and resemble the preceding discharge less the leader and return stroke phase. The radiation exhibits a similar structure, at each of the frequencies monitored.

Levine, D. M.↗

Study of Static Microchannel Plate Saturation Effects for the Fast Plasma Investigation Dual Electron Spectrometers on NASA's Magnetospheric MultiScale Mission

Imaging detecting systems based on microchannel plates (MCPs) are the most common for low energy plasma measurements for both space borne and ground applications. One of the key parameters of these detection systems is the dynamic range of the MCP's response to the input fluxes of charged particles. For most applications the dynamic range of the linear response should be as wide as possible. This is especially true for the Dual Electron Spectrometers (DESs) of the Fast Plasma Investigation (FPI) on NASA's Magnetospheric MultiScale (MMS) mission because a wide range of input fluxes are expected. To make use of the full available dynamic range, it is important to understand the MCP response behavior beyond the linear regime where the MCPs start to saturate. We have performed extensive studies of this during the characterization and calibration of the DES instruments and have identified several saturation effects of the detection system. The MCP itself exhibits saturation when the channels lack the ability to replenish charge sufficiently rapidly. It is found and will be shown that the ground system can significantly impact the correct measurement of this effect. As the MCP starts to saturate, the resulting pulse height distribution (PHD) changes shape and location (with less pulse height values), which leads to truncation of the PHD by the threshold set on the detection system discriminator. Finally, the detection system pulse amplifier exhibits saturation as the input flux drives pulse rates greater than its linear response speed. All of these effects effectively change the dead time of the overall detection system and as a result can affect the quality and interpretation of the flight data. We present results of detection system saturation effects and their interaction with special emphasis on the MCP related effects.

detecting system↗

Drilling of sub-100 μm hourglass-shaped holes in diamond with femtosecond laser pulses

We present images of microholes drilled in diamond using a homemade femtosecond Yb : KGW laser. We use a femtosecond laser source emitting pulses with a duration of 230 fs at a wavelength of 1030 nm, the focusing spot size amounting to 8.9 μm. The effect of the pulse energy and the number of pulses on the microhole geometry (hole diameter, circularity, taper angle, and drilling quality) is evaluated. The obtained results demonstrate the feasibility of drilling of hourglass-shaped holes in a diamond sample, which have similar diameters at the hole entrance (92 μm) and exit (95 μm), but a much smaller diameter (28 μm) at a certain waist section inside the hole. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neural network-based control of an ultrafast laser

With the recent advances in machine learning (ML) and data science (DS), the control, modeling, and analysis of these complex systems continues to improve. In this work, we report on the optimization of the intensity of a femtosecond laser using feedforward neural networks (FFNN) that model the input–output relationships of the data. The input parameters of the system were optimized to achieve the required performance of the femtosecond laser. We propose a neural network-based control system to model the relationship between the spectral amplitude and phase of the input laser pulse at the amplifier input and the shape of the output pulse. Low-jitter laser parameter inputs and the resulting laser pulse duration were modeled, and the resulting correlation between the input and output data was used to optimize the laser pulse. Here, we demonstrate improved processing and laser control performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗

Variation of the pulse profile of Hercules X-1

The X-ray pulsar Her X-1 was observed in an on-state during its 35th cycle of activity in May, 1983 using the gas scintillation proportional counter (GSPC) array of the Tenma X-ray astronomy satellite. The outstanding features observed during the declining phase of the on-state included: a sharp decrease in the main X-ray pulse amplitude; and a steady increase in the column density of cool matter. On the basis of the spectral shape of the pulses, it is suggested that the main phase was attenuated due to electron scattering of the X-ray beam in a highly ionized medium located 3 x 10 to the 8th cm from the neutron star. Near the end of the on-state, the main pulse totally disappeared and a plain sinusoidal profile was observed. The observed pulse profiles are reproduced in graphic form.

Ohashi, T.↗

Energy density and spectrum of single-cycle and sub-cycle electromagnetic pulses

Based on the exact solution of the Maxwell equations in the form of a collapsing spherical vector wave specified by an arbitrary function of time, we have calculated the maximum energy density that can be achieved when focusing extremely short pulses of various shapes. It is shown that our earlier formula expressing the maximum energy density in terms of the spectrum parameters for Gaussian quasi-monochromatic pulses is approximately (with an accuracy of ±40 %) valid for the main types of extremely short pulses. (extremely short laser pulses)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pulsed Airborne Lidar Measurements of Atmospheric CO2 Column Absorption and Line Shapes from 3-13 km Altitudes

We have developed a pulsed lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's planned ASCENDS space mission. Our technique uses two pulsed laser transmitters allowing simultaneous measurement of a CO2 absorption line in the 1570 nm band, O2 extinction in the Oxygen A-band and surface height and backscatter. The lidar measures the energy and time of flight of the laser echoes reflected from the atmosphere and surface. The lasers are rapidly and precisely stepped in wavelength across the CO2 line and an O2 line region during the measurement. The direct detection receiver uses a telescope and photon counting detectors, and measures the background light and energies of the laser echoes from the surface along with scattering from any aerosols in the path. The gas extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on- and off- line signals via the DIAL technique. Time gating is used to isolate the laser echo signals from the surface, and to reject laser photons scattered in the atmosphere. The time of flight of the laser pulses are also used to estimate the height of the scattering surface and to identify cases of mixed cloud and ground scattering. We have developed an airborne lidar to demonstrate the CO2 measurement from the NASA Glenn Lear-25 aircraft. The airborne lidar steps the pulsed laser's wavelength across the selected CO2 line with 20 steps per scan. The line scan rate is 450 Hz, the laser pulse widths are 1 usec, and laser pulse energy is 24 uJ. The time resolved laser backscatter is collected by a 20 cm telescope, detected by a photomultiplier and is recorded by a photon counting system. We made initial airborne measurements on flights during fall 2008. Laser backscatter and absorption measurements were made over a variety of land and water surfaces and through thin clouds. The atmospheric CO2 column measurements using the 1572.33 nm CO2 lines. Two flights were made above the US Department of Energy's (DOE) SGP ARM site at altitudes from 3-8 km. These flights were coordinated with DOE investigators who flew an in-situ CO2 sensor on a Cessna aircraft under the path. The increasing CO2 line absorptions with altitudes were evident and comparison with in-situ measurements showed agreements to 6 ppm. In spring 2009 we improved the aircraft's nadir window and during July and August we made 9 additional 2 hour long flights and measured the atmospheric CO2 absorption and line shapes using the 1572.33 nm CO2 line. Measurements were made at stepped altitudes from 3-13 km over a variety of surface types in Nebraska, Illinois, the SGP ARM site, and near and over the Chesapeake Bay in North Carolina and eastern Virginia. Strong laser signals and clear CO2 line shapes were observed at all altitudes, and some measurements were made through thin clouds. The flights over the ARM site were underflown with in-situ measurements made from the DOE Cessna. Analysis shows that the average signal levels follow predicted values, the altimetry measurements had an uncertainty of about 4 m, and that the average optical line depths follow the number density calculated from in-situ sensor readings. The Oklahoma and east coast flights were coordinated with a LaRC/ITT CO2 lidar on the LaRC UC-12 aircraft, a LaRC in-situ CO2 sensor, and the Oklahoma flights also included a JPL CO2 lidar on a Twin Otter aircraft. More details of the flights, measurements, analysis and scaling to space will be described in the presentation.

Abshire, James↗