Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

An RTDS-Based Testbed for Investigating the Impacts of Transmission-Level Disturbances on Solar PV Operation

The increasing penetration of renewable energy resources such as solar and wind via power electronic inverters is challenging grid dynamics, as well as grid planning, operation, and protection. Recently, the North American Electric Reliability Corporation (NERC) has reported a series of similar events of the unintended loss of solar generation in Southern California over a large geographic area following the transmission-level disturbances. These events highlight the importance of understanding the characteristics of the transmission-side disturbances propagating into the distribution systems and their impacts on the operation of inverter-based resources. In this paper, a real-time electromagnetic simulation testbed is constructed for real-time electromagnetic simulations to generate realistic transmission-level disturbances and investigate their impacts on the solar PV operation under different fault types and locations, solar penetration levels, and loading levels. Through the simulation analysis and grid strength assessment, it is found that the grid strength at points of integration (POIs) of solar PVs significantly affects the transient stability of solar generators. Particularly, undesirable transient stability events are more likely to occur at the weak POIs following the transmission-level disturbances. Moreover, undesirable transient stability events become severer when the transmission-level disturbance is closer to the weak POIs or the disturbances become more serious. Additionally, the impact of the transmission-level disturbances on the solar PVs at the weak POIs exacerbate with the increasing solar penetration levels and loading levels. Thus, it is important to study and develop new technologies for grid planning, operation, and protection in weak grid conditions to address the emerging issues of integrating the high penetration of solar PVs and other IBRs.

14 SOLAR ENERGY↗

Anomaly Detection in Liquid Sodium Cold Trap Operation with Multisensory Data Fusion Using Long Short-Term Memory Autoencoder

Sodium-cooled fast reactors (SFR), which use high temperature fluid near ambient pressure as coolant, are one of the most promising types of GEN IV reactors. One of the unique challenges of SFR operation is purification of high temperature liquid sodium with a cold trap to prevent corrosion and obstructing small orifices. We have developed a deep learning long short-term memory (LSTM) autoencoder for continuous monitoring of a cold trap and detection of operational anomaly. Transient data were obtained from the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The cold trap purification at METL is monitored with 31 variables, which are sensors measuring fluid temperatures, pressures and flow rates, and controller signals. Loss-of-coolant type anomaly in the cold trap operation was generated by temporarily choking one of the blowers, which resulted in temperature and flow rate spikes. The input layer of the autoencoder consisted of all the variables involved in monitoring the cold trap. The LSTM autoencoder was trained on the data corresponding to cold trap startup and normal operation regime, with the loss function calculated as the mean absolute error (MAE). The loss during training was determined to follow log-normal density distribution. During monitoring, we investigated a performance of the LSTM autoencoder for different loss threshold values, set at a progressively increasing number of standard deviations from the mean. The anomaly signal in the data was gradually attenuated, while preserving the noise of the original time series, so that the signal-to-noise ratio (SNR) averaged across all sensors decreased below unity. Results demonstrate detection of anomalies with sensor-averaged SNR < 1.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Methodology for Exploring Water and Hydropower Operating Criteria That Simultaneously Improve Economic and Environmental Considerations

Despite the reliability and flexibility of hydropower, the operation of hydroelectric power plants may have significant impacts on the downstream river system, including its water stage, sediment transport, and water temperature, ultimately affecting the ecology. To address these challenges, there is a need to identify water scheduling patterns that improve both hydropower economics and the environment relative to current operations. This paper presents a new methodology to explore promising operational criteria/rules that can achieve such improvements. Typical environmental impact statements and relicensing processes generally perform detailed site-specific analyses of a few alternatives that focus on reservoir water release operating rules and their associated environmental impacts. In contrast, the methodology presented in this article uses a widely applicable approach that explores a much larger solution space. This large set of potential alternatives can be represented in a multidimensional space for which one axis represents the economic value and the other axis quantify individual environmental impacts (e.g., sediment transport and fish growth), and they are explored via two approaches: a Monte Carlo simulation that identifies “win–win” alternatives and a multi-objective optimization problem that identifies Pareto-optimal alternatives.

13 HYDRO ENERGY↗

Effect of Split-Injection Strategies on Engine Performance and Emissions under Cold-Start Operation

The recently concluded partnership for advancing combustion engines (PACE) was a US Department of Energy consortium involving multiple national laboratories focused on addressing key efficiency and emission barriers in light-duty engines. Generation of detailed experimental data and modeling capabilities to understand and predict cold-start behavior was a major pillar in this program. Cold-start, as defined by the time between first engine crank and three-way catalyst light-off, is responsible for a large percentage of NOx, unburned hydrocarbon, and particulate matter emissions in light-duty engines. Minimizing emissions during cold-start is a trade-off between achieving faster three-way catalyst light-off, and engine out emissions during that period. In this study, engine performance, emissions, and catalyst warmup potential were monitored while the engine was operated using a single direct injection (baseline case) as well as a two-way-equal-split direct injection strategy. These injection strategies were analyzed at a range of cold-start-operation relevant retarded spark timings of up to 25 degrees after top dead center of firing (dATDCf). A stoichiometric 2-bar NIMEP steady-state condition was used for all cases to simulate cold-start operation. Significant improvement in engine stability was observed with the two-way-split injection strategy at the retarded spark timings allowing for up to 2.5x increase in exhaust heat rate when engine operation is stability constrained. Similar fuel-loss-to-oil trends with exhaust heat rate were observed for both single and two-way-split injection strategies. However, the two-way split injection was observed to produce higher NOx emissions per unit exhaust heat rate. A single data point run with three-way-split direct injection at a very retarded spark-timing of 30 dATDCf pointed to further improvements in engine stability and reduction in fuel-loss-to-oil as compared to single injection strategy. Engine stability decreased as spark timing was initially retarded with a single injection but was observed to plateau and stabilize beyond spark timing of 10 dATDCf. Finally, for the two-way-split-injection strategy, retarding the start of injection (SOI) timing of the second injection led to a decrease in engine stability as well as an increase in soot emissions.

42 ENGINEERING↗

Test Vector Development for Verification and Validation of Heavy-Duty Autonomous Vehicle Operations

The current focus in the ongoing development of autonomous driving systems (ADS) for heavy duty vehicles is that of vehicle operational safety. To this end, developers and researchers alike are working towards a complete understanding of the operating environments and conditions that autonomous vehicles are subject to during their mission. This understanding is critical to the testing and validation phases of the development of autonomous vehicles and allows for the identification of both the nominal and edge case scenarios encountered by these systems. Previous work by the authors saw the development of a comprehensive scenario generation framework to identify an operating domain specification (ODS), or external and internal conditions an autonomous driving system can expect to encounter on its mission to form critical scenario groups for autonomous vehicle testing and validating using statistical patterns, clustering, and correlation. Continuing this prior work, this paper focuses on the generation of test cases based on the critical scenarios identified that can be used to prioritize either the most common nominal driving scenarios or the least common severe driving scenarios. These test cases can then be used validate, through simulation or real-world testing, the operating design domain (ODD) for a generalized driving mission and built upon to identify spatial and temporal impacts on the driving mission of an autonomous vehicle.

Siekmann, Adam↗

Operational-based annual energy production uncertainty: are its components actually uncorrelated?

Calculations of annual energy production (AEP) from a wind power plant – whether based on preconstruction or operational data – are critical for wind plant financial transactions. The uncertainty in the AEP calculation is especially important in quantifying risk and is a key factor in determining financing terms. A popular industry practice is to assume that different uncertainty components within an AEP calculation are uncorrelated and can therefore be combined as the sum of their squares. We assess the practical validity of this assumption for operational-based uncertainty by performing operational AEP estimates for more than 470 wind plants in the United States, mostly in simple terrain. We apply a Monte Carlo approach to quantify uncertainty in five categories: revenue meter data, wind speed data, regression relationship between density-corrected wind speed (from reanalysis data) and measured wind power, length of long-term-correction data set, and future interannual variability. We identify correlations between categories by comparing the results across all 470 wind plants. We observe a positive correlation between interannual variability and the linearized long-term correction; a negative correlation between wind resource interannual variability and linear regression; and a positive correlation between reference wind speed uncertainty and linear regression. Then, we contrast total operational AEP uncertainty values calculated by omitting and considering correlations between the uncertainty components. We quantify that ignoring these correlations leads to an underestimation of total AEP uncertainty of, on average, 0.1% and as large as 0.5% for specific sites. Although these are not large increases, these would still impact wind plant financing rates; further, we expect these values to increase for wind plants in complex terrain. Based on these results, we conclude that correlations between the identified uncertainty components should be considered when computing the total AEP uncertainty.

17 WIND ENERGY↗

NMPC for Mode-Switching Operation of Reversible Solid Oxide Cell Systems

Solid oxide cells (SOCs) are a promising dual-mode technology that generates hydrogen through high-temperature water electrolysis and generates power through a fuel cell reaction that consumes hydrogen. Reversible operation of SOCs requires a transition between these two modes for hydrogen production setpoints as the demand and price of electricity fluctuate. Moreover, a well-functioning control system is important to avoid cell degradation during mode-switching operation. In this work, we apply nonlinear model predictive control (NMPC) to an SOC module and supporting equipment and compare NMPC performance to classical proportional integral (PI) control strategies, while ramping between the modes of hydrogen and power production. While both control methods provide similar performance in many metrics, NMPC significantly reduces cell thermal gradients and curvatures (mixed spatial-temporal partial derivatives) during mode switching. A dynamic process flowsheet of the reversible SOC system was developed in the open-source, equation-based IDAES modeling framework. Our IDAES dynamic simulation results show that NMPC can ramp the SOC system between hydrogen and power production targets within short mode-switching times. Moreover, NMPC can comply with operating limits in the SOC system more effectively than PI, and only NMPC can directly enforce user-specified limits for mixed spatial-temporal partial derivatives of temperature. This allows for management of the trade-off be-tween operating efficiency and cell degradation, which is dependent on these temperature curvatures.

Li, Mingrui↗

Functional and Operating Requirements for the Microreactor Agile Non-Nuclear Experimental Test Bed (MAGNET)

Microreactors, or small, transportable reactors with a capacity of < 20 MWTH, are sought to provide heat and power for myriad applications in remote areas, military installations, emergency operations, humanitarian missions and disaster relief zones as illustrated in Figure 1. These small, transportable reactor designs, while offering many advantages, are largely untested and unproven. System and component testing is needed to demonstrate to regulators that these designs are safe and to convince customers that the systems are robust, reliable, and efficient. The microreactor agile non-nuclear experimental test bed (MAGNET) is being constructed at Idaho National Laboratory to assist with the development, demonstration, and validation of microreactor components and systems. MAGNET will support technology maturation to reduce uncertainty and risk relative to the operation and deployment of this unique class of systems. Stakeholders for this test bed include microreactor developers, energy users, and regulators. Regulators will be engaged early in the design and testing to expedite regulatory approval and licensing. Within MAGNET, systems and components can be safely tested, providing valuable information on operating regimes, failure modes, and thresholds. Since there are various types of microreactors being proposed, which can be classified according to their core cooling method, heat-pipes, gas-cooled (pebble bed or prismatic), molten salt, light water, or light water, the goal is to provide a test bed that is broadly applicable to multiple microreactor concepts. Each reactor type poses a different set of design and operational challenges and performance claims stated by commercial vendors have not been independently verified through rigorous testing. The initial set of tests to be performed in MAGNET are targeted towards demonstrating the feasibility and performance of heat-pipe cooled reactors, since this concept is unique to very small nuclear reactors. However, the testbed will be constructed to accommodate other designs in addition to heat-pipe cooled reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Data-Driven Operator Theoretic Methods for Global Phase Space Learning

In this work, we propose to apply the recently developed Koopman operator techniques to explore the global phase space of a nonlinear system from time-series data. In particular, we address the problem of identifying various invariant subsets of a phase space from the spectral properties of the associated Koopman operator constructed from time-series data. Moreover, in the case when the system evolution is known locally in various invariant subspaces, then a phase space stitching result is proposed that can be applied to identify a global Koopman operator. A biological system, bistable toggle switch and a second-order nonlinear system example are considered to illustrate the proposed results. The construction of this global Koopman operator is very helpful in experimental works as multiple experiments can't be run at the same time starting from several initial conditions.

Nandanoori, Sai Pushpak↗

System and method to characterize and identify operating modes of electric loads

A system characterizes and identifies one of a plurality of different operating modes of a number of electric loads. The system includes a processor; a voltage sensor providing a voltage signal for one of the electric loads to the processor; a current sensor providing a current signal for the one electric load to the processor; and a routine executed by the processor and structured to characterize the different operating modes using steady state and voltage-current trajectory features determined from the voltage and current signals, and to identify a particular one of the different operating modes based on a plurality of operating mode membership functions of the steady state and voltage-current trajectory features.

Yang, Yi↗

Optimal Efficiency and Operational Cost Savings: A Framework for Automated Rooftop PV Placement

Residential energy consumers are charged based on a utility rate structure, such as net metering or feed-in tariff. To lower consumers' electricity bills, expensive batteries are deployed to reduce the electricity fed from the grid during peak hours. However, strategic photovoltaic (PV) panel placement enables the reduction of operational energy cost while considering the spatial feasibility and efficiency for hosting rooftop PV. In this paper, we present a framework to automatically identify the optimal location of rooftop PV panels on residential buildings. Our framework integrates multiple workflows, including energy and environmental simulation, parametric modeling, and optimization to identify the ideal location of PV panels to balance the demand and supply at a building and community scale. These workflows are linked using the Grasshopper plug-in for Rhinoceros CAD software. The framework includes two different workflows, each satisfying a target for optimal PV placement: (a) maximizing PV panel efficiency, where users aim to maximize energy generation, and (b) minimizing operational energy cost, where "best'' panels are selected considering utility rates for operational energy cost. Our framework is demonstrated in a residential community in Fort Collins, Colorado, to generate the optimal PV placement for each of the two aforementioned targets. Results from the two workflows are compared to illustrate the effect of PV location and orientation on solar energy production efficiency and operational energy cost. The developed workflows are introduced as tools within the Grasshopper plug-in to investigate the solar potential of rooftop PV panels while taking into account factors such as contextual shading, utility rate structures, and buildings' energy demand profiles.

30 DIRECT ENERGY CONVERSION↗

Performing optimized collective operations in a irregular subcommunicator of compute nodes in a parallel computer

In a parallel computer, performing optimized collective operations in an irregular subcommunicator of compute nodes may be carried out by: identifying, within the irregular subcommunicator, regular neighborhoods of compute nodes; selecting, for each neighborhood from the compute nodes of the neighborhood, a local root node; assigning each local root node to a node of a neighborhood-wide tree topology; mapping, for each neighborhood, the compute nodes of the neighborhood to a local tree topology having, at its root, the local root node of the neighborhood; and performing a one way, rooted collective operation within the subcommunicator including: performing, in one phase, the collective operation within each neighborhood; and performing, in another phase, the collective operation amongst the local root nodes.

Davis, Kristan Suzanne D.↗

Tests of Cs-Free Operation of the SNS RF H⁻ Ion Sources

Tests were performed at SNS in collaboration with visiting colleagues from ISIS, UK to evaluate the uncesiated beam performance of the SNS RF H⁻ ion sources. Two spare experimental sources, one with internal antenna and one with external antenna were used for the tests. The beam currents achieved with Cs-free operations accounted for about 1/3 to 1/2 of the beam currents produced with cesiated operations. ~17 mA uncesiated H⁻ current was demonstrated within the tested RF power range up to 65 kW with the internal antenna source and ~15 mA with up to 40 kW RF with the external antenna source. In Cs-free operations, the power supply for the electron dumping electrode was loaded down below its set voltage but was not too drastic to tamper the operation.

Han, Baoxi↗

Considerations for Safeguards Implementation in the Post-Operational Facility Life Cycle

Hundreds of facilities around the world under International Atomic Energy Agency (IAEA) safeguards are currently permanently shutdown or undergoing decommissioning. For facilities in States with a comprehensive safeguards agreement (CSA) in force, safeguards obligations under the CSA extend until the IAEA has determined for safeguards purposes that a facility has been decommissioned (i.e., the IAEA has verified that the nuclear material has been removed and residual structures and equipment essential for its use have been removed or rendered inoperable). The IAEA Department of Safeguards recently issued a report providing high-level guidance to States on IAEA safeguards implementation throughout the post-operational life cycle phases of facilities and locations outside facilities. These phases include permanent shutdown, closed-down, and decommissioned for safeguards purposes. Additional consideration is needed for how post-operational facilities might be consistently evaluated when developing State-level safeguards approaches. This work presents ideas about how the IAEA might implement the State-level concept and associated elements (e.g., State-specific factors) throughout the post-operational life cycle, focusing on maintaining effectiveness and gaining efficiencies where appropriate. Considerations include whether State-specific factors should influence facility status, how a change in a facility’s post-operational status might impact a State’s acquisition path analysis, and how rendering inoperable/removal of essential equipment could affect resources expended on safeguards implementation.

Hogue, Karen↗

Conceptual Design of Pulverized Coal Electricity Generating Units for Flexible Operation

This presentation was given by Marc Turner, NETL Support Contractor, at the International Center for Sustainable Carbon's "The Energy Transition - the Role for Sustainable Carbon" workshop held in Sardinia, Italy on November 16-18, 2022. The presentation addresses the NETL report titled "Conceptual Design of Pulverized Coal Electricity Generating Units for Flexible Operation" published on September 6, 2022. This study presents an independent conceptual assessment of the features, cost, and performance of pulverized coal power plants (without carbon dioxide capture) intended for flexible, rather than baseload, operation. The objective was to leverage the already substantial knowledge base about flexible operation and develop state-of-the-art pulverized coal power plant cases that are designed to accommodate flexible operation within an electric grid having a high level of renewable generation. This is of significant importance in coal-dependent regions of the world as variable renewable energy becomes more prevalent.

Turner, Marc↗

Fault Characterization and Diagnostics Supporting Condition-Based Operation and Maintenance of Gas Turbine Engines

Condition-Based Operation and Maintenance (CBOM) is the state-of-the-art in maintenance approaches for gas turbine engines. CBOM applies engine sensor information to the optimization of future operation and maintenance procedures; this technique reduces costs for engine operators by minimizing unplanned outages and catastrophic engine degradation. However, due to the complexities of gas turbine operation and the lack of available engine sensors, further development is required to fully realize the benefits of CBOM. In the turbine section, rotating components interact with high temperature flows, which creates intense thermal and mechanical stresses. As a result, there are numerous mechanisms of component degradation in the turbine section. Furthermore, turbine components – like stator vanes and rotor blades – are among the most expensive in the engine because they are complex to design and manufacture. For these reasons, this dissertation addresses two main questions: (i) which parameters or faults within the turbine section are most important to monitor, and (ii) how can these parameters or faults be monitored in an engine-relevant environment? Although many turbine parameters and faults have been investigated in the open literature, there are some faults that are still not well understood. Rotor-casing eccentricity, which causes a non-constant blade tip clearance around the annulus, has not been investigated in terms of its effects on turbine efficiency. Therefore, the first study in this dissertation quantifies overall and local turbine efficiency for varying levels of rotor-casing eccentricity. Results showed negligible variations to overall turbine efficiency, meaning rotor-casing eccentricity only becomes relevant to CBOM when its severity causes rotordynamic issues. Purge flow is critical to turbine hardware longevity because it prevents ingestion of hot main gas path (MGP) flow into the under-platform regions. Despite its importance, there are currently no methods for monitoring purge flow performance in an engine environment. Therefore, the second study in this dissertation develops a predictive model for sealing effectiveness using inputs from two fast-response pressure sensors. Results exhibited low prediction errors across a full range of purge flow rates, which supports the viability of the modelling approach for CBOM. The final two studies in this dissertation address blade coolant flow monitoring. This cooling flow is responsible for protecting the turbine blades from the MGP flow, which exits the combustor at temperatures greater than the blade melting point. These studies showed that temperature measurements on the blade surface can be used to accurately predict blade coolant flow rate, and that defining the candidate features relative to the coolant trajectory is important for maintaining accuracy as coolant flow rate degradation occurs. This work enables blade coolant flow monitoring, which is currently not possible through existing condition monitoring techniques.

condition-based, gas turbines, diagnostics,↗

Multi-spool CO2 aircraft power system for operating multiple generators

A CO 2 bottoming cycle system includes a first compressor operatively connected to a first turbine through a first shaft. A first generator is operatively connected to the first shaft. A second compressor is fluidically connected to the first compressor. The second compressor is operatively connected to a second turbine through a second shaft. A second generator is operatively connected to the second shaft. The first turbine is fluidically connected to the second turbine.

Taylor, Stephen H.↗

Learning Distributed Geometric Koopman Operator for Sparse Networked Dynamical Systems

Koopman operator theory provides an alternative to study nonlinear networked dynamical systems by mapping the state space to an abstract higher dimensional space where the system evolution is linear. Recent works show the application of graph neural networks (GNNs) to learn state to object-centric embeddings and achieve centralized block-wise computation of Koopman operator (KO) under additional assumptions on the underlying agents properties and constraints on the KO structure. However, the computational complexity of learning the Koopman increases exponentially for networked systems where the number of possible system states grows in a combinatorial fashion with the number of nodes. The learning challenge is further amplified for sparse networks by two factors: 1) sample sparsity for learning the Koopman operator in the non-linear space, and 2) the divergence in the dynamics of individual nodes or from one subgraph to another. Our work aims to address these challenge by formulating the representation learning of networked dynamical systems into a multi-agent paradigm and learning the Koopman operator in a distributive manner. The computational as well as performance advantages of distributed Koopman is predominant for sparse networks whereas for fully connected networks, it is shown to coincide with the centralized one. The empirical study on rope system, network of oscillators and a synthetic power system show comparable and superior performance along with computational benefits with the state-of-the-art methods.

Mukherjee, Sayak↗