Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Observables for recoil identification in high-definition Gas Time Projection Chambers

Directional detection of nuclear recoils is broadly desirable in nuclear and particle physics. At low recoil energies, this capability may be used to confirm the cosmological origin of a dark matter signal, to penetrate the so-called neutrino floor, or to distinguish between different neutrino sources. Gas Time Projection Chambers (TPCs) can enable directional recoil detection if the readout granularity is sufficiently high, as is the case when micro-pattern gaseous detectors (MPGDs) are utilized. A key challenge in such detectors is identifying and rejecting background electron recoil events caused by gamma rays from radioactive contaminants in the detector materials and the environment. We define new observables that can distinguish electron and nuclear recoils, even at keV-scale energies, based on the simulated ionization's topology. Here we perform a simulation study that shows these observables outperform the traditionally used discriminant, dE/dx, by up to three orders of magnitude. Furthermore, these new observables work well even at ionization energies well below 10keV and remain robust even in the regime where directionality fails.

79 ASTRONOMY AND ASTROPHYSICS↗

Algorithms for coordinate reconstruction in position-sensitive virtual Frisch-grid detectors

Arrays of position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors provide a cost-effective solution for integrating large-area arrays for gamma-ray imaging and spectroscopy. These detectors employ high-aspect ratio CZT crystals (bars) with thicknesses up to 50 mm and cross-sections of up to 10 × 10 mm 2 . Despite the long drift distances of charge carriers in such crystals, the detectors have demonstrated excellent performance, achieving energy resolutions better than 1 % full width at half maximum (FWHM) at 662 keV and 3D position resolutions finer than 1 mm. The high spatial resolution is a critical feature of these detectors, as it enables correction of response non-uniformities caused by crystal defects, which remain present even in the highest-quality CZT material. Dislocations and dislocation walls are the primary defects responsible for variations in charge carrier losses as they drift from the interaction points toward the charge-collecting electrodes. The mechanism by which these defects affect carrier transport is generally well understood. Dislocations and sub-grain boundaries act as sinks for carrier-trapping centers, primarily impurities and secondary phases such as tellurium inclusions and precipitates. Here, these regions exhibit significantly higher carrier-trapping rates, leading to variations in the μτ-products. Because the locations of these micron-sized regions are fixed within the detector volume, fluctuations in the total collected charge arise from the random distribution of interaction sites. This results in non-uniform detector responses and degradation of energy resolution. However, by measuring the interaction-site locations with sufficient precision, charge-loss variations can be accurately corrected, allowing recovery of nearly intrinsic energy resolution.

47 OTHER INSTRUMENTATION↗

Advances in CdZnTeSe for Radiation Detector Applications

Detection of X- and gamma-rays is essential to a wide range of applications from medical imaging to high energy physics, astronomy, and homeland security. Cadmium zinc telluride (CZT) is the most widely used material for room-temperature detector applications and has been fulfilling the requirements for growing detection demands over the last three decades. However, CZT still suffers from the presence of a high density of performance-limiting defects, such as sub-grain boundary networks and Te inclusions. Cadmium zinc telluride selenide (CZTS) is an emerging material with compelling properties that mitigate some of the long-standing issues seen in CZT. This new quaternary is free from sub-grain boundary networks and possesses very few Te inclusions. In addition, the material offers a high degree of compositional homogeneity. The advancement of CZTS has accelerated through investigations of the material properties and virtual Frisch-grid (VFG) detector performance. The excellent material quality with highly reduced performance-limiting defects elevates the importance of CZTS as a potential replacement to CZT at a substantially lower cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New limits on gamma-ray bursts

Two balloon flights of large-area scintillation crystal detector arrays indicate that the rate of weak gamma-ray bursts is significantly below that expected from a uniform distribution of burst sources. This result, combined with the data from stronger bursts, gives strong evidence for a galactic confinement of burst sources. Reasonable models of confinement limit the intrinsic radiated energy per burst to the order of 10 to the (39th to 41st power) ergs.

Fishman, G. J.↗

Neutron and Gamma-Ray Detection System

The present invention is a radially symmetric imaging detector that measures an incident neutron's or gamma-ray's energy and identifies its source on an event-by-event basis.

Ryan, James M.↗

Techniques for gamma rays.

The detecting systems used in high energy astrophysics are generally more similar to particle detectors than to optical devices. The basic design of the gamma ray instrument depends on whether the energy range is below about 10 MeV and therefore in the region where the Compton effect predominates in the absorption of the gamma-rays, or above that energy where electron-positron pair production is most important. The most usual approach to the detector system in the lower of the two energy intervals is to use a scintillation counter in the center of the detector system to absorb the photons and permit a measure of their energy, and to surround it by another detector which is employed as an active anticoincidence shield to discriminate against charged particles. In the gamma-ray interval above about 10 MeV, the very low flux of gamma rays and the high particle background has directed the development of high energy gamma-ray telescopes towards complicated techniques and large detector arrays. As a result, several investigators have now turned to the spark chamber as the heart of a detector system. Generally, it is surrounded by an anticoincidence system and is triggered by a counter telescope.

Fichtel, C. E.↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Gamma rays from pulsar wind shock acceleration

A shock forming in the wind of relativistic electron-positron pairs from a pulsar, as a result of confinement by surrounding material, could convert part of the pulsar spin-down luminosity to high energy particles through first order Fermi acceleration. High energy protons could be produced by this mechanism both in supernova remnants and in binary systems containing pulsars. The pion-decay gamma-rays resulting from interaction of accelerated protons with surrounding target material in such sources might be observable above 70 MeV with EGRET (Energetic Gamma-Ray Experimental Telescope) and above 100 GeV with ground-based detectors. Acceleration of protons and expected gamma-ray fluxes from SN1987A, Cyg X-3 type sources and binary pulsars are discussed.

Harding, Alice K.↗

The GALILEO γ-ray array at the Legnaro National Laboratories

GALILEO, a new 4 pi high-resolution gamma-detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital readout chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy gamma-ray transitions. In this paper, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic energy calibration of the SoLid detector with horizontal muons

SoLid is a neutrino experiment at very-short baselinesearching for active-to-sterile oscillations of reactorantineutrinos. The detection principle is based on the pairing oftwo types of solid scintillators: polyvinyl toluene and $^{6}$Li:ZnS(Ag), which is a new technology used in this field ofPhysics. In addition to good neutron-gamma discrimination, thissetup allows the detector to be highly segmented; the basicdetection unit is a 5 cm cube. High segmentation provides numerousadvantages including precise localisation of the Inverse Beta Decay(IBD) products, the derivation of an antineutrino energy estimatorbased on the isolated positron energy, and a powerful backgroundreduction tool that relies on the topological signature of thesignal. Finally, the system is read out by a network ofwavelength-shifting fibres coupled to photosensors. A relativeelectromagnetic calibration is performed with horizontal cosmicmuons. This source poses the simplest calibration problem in which asingle detection unit is involved. In addition, large muon energydeposits allow us to perform a calibration at the most detailedlevel (i.e. per fibre) and to accurately define the fraction ofenergy escaping to neighbouring detection cells. A statisticalprecision at the sub-percent level is reached. The paper alsodiscusses two methods to calibrate the absolute energy scale andpresents their implementation and results. The first method relieson horizontal muons, though the precision is limited to around 10%because of the uncertainty in the energy distribution of suchmuons. A novel, alternative method based on the radioactiveamericium-beryllium source is proposed. It takes advantage of theelectron-positron pair-production process and provides a calibrationpoint at 3.4 MeV (i.e. in the core of the IBD positronspectrum). The paper is concluded with various cross-check includinga determination of the energy spectrum of the standard cosmogenicbackground candle: $^{12}$B.

Abreu, Y. [Antwerp U.]↗

Swift Burst Alert Telescope (BAT) Instrument Response

The Burst Alert Telescope (BAT), a large coded aperture instrument with a wide field-of-view (FOV), provides the gamma-ray burst triggers and locations for the Swift Gamma-Ray Burst Explorer. In addition to providing this imaging information, BAT will perform a 15 keV - 150 keV all-sky hard x-ray survey based on the serendipitous pointings resulting from the study of gamma-ray bursts and will also monitor the sky for transient hard x-ray sources. For BAT to provide spectral and photometric information for the gamma-ray bursts, the transient sources and the all-sky survey, the BAT instrument response must be determined to an increasingly greater accuracy. In this talk, we describe the BAT instrument response as determined to an accuracy suitable for gamma-ray burst studies. We will also discuss the public data analysis tools developed to calculate the BAT response to sources at different energies and locations in the FOV. The level of accuracy required for the BAT instrument response used for the hard x-ray survey is significantly higher because this response must be used in the iterative clean algorithm for finding fainter sources. Because the bright sources add a lot of coding noise to the BAT sky image, fainter sources can be seen only after the counts due to the bright sources are removed. The better we know the BAT response, the lower the noise in the cleaned spectrum and thus the more sensitive the survey. Since the BAT detector plane consists of 32768 individual, 4 mm square CZT gamma-ray detectors, the most accurate BAT response would include 32768 individual detector response functions to separate mask modulation effects from differences in detector efficiencies! We describe OUT continuing work to improve the accuracy of the BAT instrument response and will present the current results of Monte Carlo simulations as well as BAT ground calibration data.

Parsons, A.↗

A Maskless Gamma-Ray All-Sky Imager: BATSE/CGRO

The non-collimated detectors of BATSE (Burst And Transient Source Experiment) on the Compton Gamma Ray Observatory (CGRO) can be used as a high sensitivity hard X-ray and low energy gamma-ray all-sky imager in the energy range between 20 keV and 2 MeV. The fluxes from sources in the sky are modulated as the spacecraft orbits the Earth. The CGRO orbital precession further allows sampling of sky in strips corresponding to the limb of the earth at any given time. The modulation data are transformed into images by various reconstruction methods. High sensitivity images of location accuracy of about 0.1 deg and source seperation of about 1 deg are obtained.

Zhang, S. N.↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-ray and millimeter-wave emissions from the 1991 June X-class solar flares

We have studied the spectacular 1991 June X-class flares using gamma-ray data from the Charged Particle Detectors (CPDs) of the Burst and Transient Source Experiment (BATSE) on the Compton Gamma Ray Observatory (CGRO) and 80 GHz millimeter data from Nobeyama, Japan. The CPDs were the only CGRO instrument that did not saturate during the extremely intense 1991 June 4 flare. We have shown that for this flare the CPDs respond to MeV photons, most of which are due to bremsstrahlung produced by relativistic electrons at the Sun. We have further shown that the gamma-ray and millimeter observations agree numerically if the 80 GHz radiation is gyrosynchrotron radiation produced by trapped electrons and the gamma rays are thick-target bremsstrahlung due to electrons precipitating out of the trap. The requirement that the trapping time obtained from the numerical comparison be consistent with the observed time profiles implies a magnetic field between about 200 and 300 G and an electron spectral index between about 3 to 5. By comparing the CPD observations with both the 80 GHz data and nuclear line data from the Energetic Gamma Ray Experiment Telescope (EGRET) and the Oriented Scintillation Spectroscopy Experiment (OSSE) on CGRO for the flares of June 4, 6, 9, and 11, we found that the ratio of the CPD counts to both the millimeter flux densities and the nuclear line fluences decreases with decreasing flare heliocentric angle. All of these flares were produced in the same active region. We interpreted this result in terms of a loop model in which the gyrosynchrotron emission is produced in the coronal portion of the loop where the electrons are kept isotropic by pitch angle scattering due to plasma turbulence, while the bremsstrahlung is produced by precipitating electrons that interact anisotropically. We found that the trapping time in the coronal portion is time dependent, reaching a minimum of about 10 s at the peak of the CPD count rate. We suggested the damping of the turbulence as a possible reason for the variation of the trapping time. turbulence as a possible reason for the variation of the trapping time.

Ramaty, Reuven↗