Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calculation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Variational Monte Carlo calculations of n + H 3 scattering

A paramount goal in nuclear physics is to unify ab initio treatments of bound and unbound states. The position-space quantum Monte Carlo (QMC) methods have a long history of successful bound-state calculations in light systems but have seen minimal implementation in unbound systems. Here, we introduce a numerical method to improve the efficiency and accuracy of unbound-state calculations in QMC. As an initial application, we compute scattering observables for the smallest system available to probe three-body forces, the neutron-triton system, using variational Monte Carlo (VMC) wave functions. The method involves inferring long-range amplitudes in the wave function from integrals over the short-range region where all the particles interact. This approach using integral relations is well established in the literature; here, we develop it for the QMC framework. We validate our approach with a consistency check between short-range spectroscopic overlap functions computed from direct evaluation and from the integral relations; scattering amplitudes are long-range asymptotics of those overlaps. Comparison against published benchmark calculations using the same potential demonstrates that when applied to the current VMC wave functions, the integral method produces more accurate scattering observables than direct evaluation from the same variational wave function. However, it still differs noticeably from the exact results. Using additional interactions, we then present phase shifts and mixing parameters for the n + 3 H system. In particular, we present one of the first applications of the Norfolk family of local coordinate-space chiral potentials in unbound systems of A > 2. The Norfolk results accurately describe s-wave scattering but predict p-wave cross sections too large. Compared with previous QMC scattering calculations, the integral method avoids difficulties associated with the precise computation of energy differences and with convergence outside the interaction region, which is particularly severe in the variational calculation. Application of the integral method here paves the way for its use in Green's function Monte Carlo (GFMC) calculations. In GFMC, the wave functions are more accurate, but the high-precision convergence of their tails is slow, and there are additional difficulties in reading out amplitudes. Here, the integral methods will address both of those remaining problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calculation of nuclear reaction cross sections on excited nuclei with the coupled-channels method

We calculate nuclear cross sections on excited nuclei in the fast neutron energy range. We partition the whole process into two contributions: the direct reaction part and the compound nuclear reactions. A coupled-channels method is used for calculating the direct transition of the nucleus from the initial excited state, which is a member of the ground-state rotational band, to the final ground and excited low-lying levels. This process is strongly affected by the channel coupling. The compound nuclear reactions on the excited state are calculated with the statistical Hauser-Feshbach model, with the transmission coefficients obtained from the coupled-channels calculation. The calculations are performed for a strongly deformed nucleus {sup 169}Tm, and selected cross sections for the ground and first excited states are compared. The calculation is also made for actinides to investigate possible modification to the fission cross section when the target is excited. It is shown that both the level coupling for the entrance channel, and the different target spin, change the fission cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exact and fast calculation of the X-ray pair distribution function

A fast and exact algorithm to calculate the powder pair distribution function (PDF) for the case of periodic structures is presented. The new algorithm calculates the PDF by a detour via reciprocal space. The calculated normalized total powder diffraction pattern is transferred into the PDF via the sine Fourier transform. The calculation of the PDF via the powder pattern avoids the conventional simplification of X-ray and electron atomic form factors. It is thus exact for these types of radiation, as is the conventional calculation for the case of neutron diffraction. The new algorithm further improves the calculation speed. Additional advantages are the improved detection of errors in the primary data, the handling of preferred orientation, the ease of treatment of magnetic scattering and a large improvement to accommodate more complex instrumental resolution functions.

36 MATERIALS SCIENCE↗

THERMAL SAFETY MARGIN CALCULATION OF THE MP-2 EXPERIMENT IN THE ADVANCED TEST REACTOR

The Mini-Plate 2 (MP-2) irradiation test is a fueled experiment designed for irradiation in multiple test locations in the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). The experiment is a drop-in test where small aluminum-clad fuel plate samples (mini plates) are cooled directly by the ATR Primary Coolant System (PCS) water. The MP-2 fuel plate experiment will be irradiated in several different irradiation locations of the ATR. This fueled experiment contains aluminum-clad fuel mini plates consisting of monolithic U-Mo. Four different types of fuel plates with fuel meat thickness and cladding are part of the MP-2 test. A thermal analysis has been performed on the MP-2 experiment. A method for calculating Departure from Nucleate Boiling Ratio (DNBR) and Flow Instability Ratio (FIR) during a reactivity transient using the commercial finite element and heat transfer code ABAQUS is discussed. At the start of an ATR cycle the heat generation rate of the fueled experiment is high and the heat rate multiplier from the outer shim control cylinders is low, while the reverse is true at the end of the ATR cycle. Thermal analyses at 10 day increments during the cycle calculate the DNBR and FIR during a reactivity transient. This technique calculates DNBR for the fuel plate surfaces and FIR for all water components for each finite element surface and node at various times during the ATR cycle. Heat rates vary with time during the transient calculation that are provided by a detailed physics analysis. Oxide growth on the fuel plates is also incorporated Results from the transient calculations are displayed with the ABAQUS post processor. By calculating these parameters at each location in the finite element model, conservatism is replaced with accuracy. This allows for a greater margin for the thermal hydraulic safety parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calculation of dose decrease in a finite phantom of a {sup 192}Ir point source

The purpose of this study was to calculate the dose decrease in a finite phantom of a {sup 192}Ir-point source by using a new algorithm based on field theory. The methods used included the phenomenological application of the principle 'mirror image of an electric point source in front of a dielectric semi-plateau' to a radioactive source in a finite phantom results in a function to calculate the dose decrease near the surface. Measurements were done in a water phantom in three different experimental setups. To verify the calculated results Monte Carlo (MC) simulations of dose distribution of a {sup 192}Ir point source in 34x40x40 cm{sup 3} water were carried out. The strength of mirror source was found -0.103 of the real source. A lack scatter function was necessary to handle the dose decrease very close to surface. The measured and calculated dose values differed less than 0.9%. Both MC simulations and the new algorithm show the dose decrease near phantom surface with differences less than 2% between each other. The new algorithm based on field theory calculated the dose decrease of a {sup 192}Ir point source in a finite phantom with a very good agreement to measured and simulated data. A clinical example, which affects only a single planar boundary, is given by using molds in the treatment of skin tumors. This was calculated with the new algorithm presented in this article. The comparison with the common algorithm demonstrates the differences that might cause an overestimation of the dose, which probably leads an underdosing of the tumor. The general use of the new algorithm in brachytherapy where a variety of boundary shapes are encountered has to be verified seriously.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6 MV photon fields smaller than 4 cm produced by Cyberknife

For the small radiation field sizes used in stereotactic radiosurgery, lateral electronic disequilibrium and steep dose gradients exist in a large portion of these fields, requiring the use of high-resolution measurement techniques. These relatively large areas of electronic disequilibrium make accurate dosimetry as well as dose calculation more difficult, and this is exacerbated in regions of tissue heterogeneity. Tissue heterogeneity was considered insignificant in the brain where stereotactic radiosurgery was first used. However, as this technique is expanded to the head and neck and other body sites, dose calculations need to account for dose perturbations in and beyond air cavities, lung, and bone. In a previous study we have evaluated EBT Gafchromic film (International Specialty Products, Wayne, NJ) for dosimetry and characterization of the Cyberknife radiation beams and found that it was comparable to other common detectors used for small photon beams in solid water equivalent phantoms. In the present work EBT film is used to measure dose in heterogeneous slab phantoms containing lung and bone equivalent materials for the 6 MV radiation beams of diameter 7.5 to 40 mm produced by the Cyberknife (Accuray, Sunnyvale, CA). These measurements are compared to calculations done with both the clinically utilized Raytrace algorithm as well as the newly developed Monte Carlo based algorithm available on the Cyberknife treatment planning system. Within the low density material both the measurements and Monte Carlo calculations correctly model the decrease in dose produced by a loss of electronic equilibrium, whereas the Raytrace algorithm incorrectly predicts an enhancement of dose in this region. Beyond the low density material an enhancement of dose is correctly calculated by both algorithms. Within the high density bone heterogeneity the EBT film measurements represent dose to unit density tissue in bone and agree with the Monte Carlo results when corrected to dose to unit density tissue in bone. We conclude that EBT film is an appropriate dosimeter for measuring dose in heterogeneous materials and these measurements agree with Monte Carlo calculations of dose as implemented in the Cyberknife treatment planning system.

61 RADIATION PROTECTION AND DOSIMETRY↗

A procedure for calculation of monitor units for passively scattered proton radiotherapy beams

The purpose of this study is to validate a monitor unit (MU) calculation procedure for passively scattered proton therapy beams. The output dose per MU (d/MU) of a therapeutic radiation beam is traditionally calibrated under specific reference conditions. These conditions include beam energy, field size, suitable depth in water or water equivalent phantom in a low dose gradient region with known relative depth dose, and source to point of calibration distance. Treatment field settings usually differ from these reference conditions leading to a different d/MU that needs to be determined for delivering the prescribed dose. For passively scattered proton beams, the proton specific parameters, which need to be defined, are related to the energy, lateral scatterers, range modulating wheel, spread out Bragg peak (SOBP) width, thickness of any range shifter, the depth dose value relative to the normalization point in the SOBP, and scatter both from the range compensator and inhomogeneity in the patient. Following the custom for photons or electrons, a set of proton dosimetry factors, representing the changes in the d/MU relative to a reference condition, can be defined as the relative output factor (ROF), SOBP factor (SOBPF), range shifter factor (RSF), SOBP off-center factor (SOBPOCF), off-center ratio (OCR), inverse square factor (ISF), field size factor (FSF), and compensator and patient scatter factor (CPSF). The ROF, SOBPF, and RSF are the major contributors to the d/MU and were measured using an ion chamber in water tank during the clinical commissioning of each beam to create a dosimetry beam data table to be used for calculating the monitor units. The following simple formula is found to provide an independent method to determine the d/MU at the point of interest (POI) in the patient, namely, (d/MU)=ROF{center_dot}SOBPF{center_dot}RSF{center_dot}SOBPOCF{center_dot}OCR{center_dot}FSF{center_dot}ISF{center_dot}CPSF. The monitor units for delivering the intended dose (D) to the POI can be obtained from MU=D divide (d/MU). The accuracy and robustness of the above formula were validated by calculating the d/MU in water for many different combinations of beam parameters and comparing it with the corresponding measured d/MU by an ion chamber in a water or water/plastic phantom. This procedure has been in use for MU calculation for patient treatment fields at our facility since May 2006. The differences in the calculated and measured values of the d/MU for 623 distinct fields used for patient treatment during the period of May 2006 to February 2007 are within 2% for 99% of these fields. The authors conclude that an intuitive formula similar to the one used for monitor unit calculation of therapeutic photon beams can be used to compute the monitor units of passively scattered proton therapy beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

A correction-based dose calculation algorithm for kilovoltage x rays

Frequent and repeated imaging procedures such as those performed in image-guided radiotherapy (IGRT) programs may add significant dose to radiosensitive organs of radiotherapy patients. It has been shown that kV-CBCT results in doses to bone that are up to a factor of 3-4 higher than those in surrounding soft tissue. Imaging guidance procedures are necessary due to their potential benefits, but the additional incremental dose per treatment fraction may exceed an individual organ tolerance. Hence it is important to manage and account for this additional dose from imaging for radiotherapy patients. Currently available model-based dose calculation methods in radiation treatment planning (RTP) systems are not suitable for low-energy x rays, and new and fast calculation algorithms are needed for a RTP system for kilovoltage dose computations. This study presents a new dose calculation algorithm, referred to as the medium-dependent-correction (MDC) algorithm, for accurate patient dose calculation resulting from kilovoltage x rays. The accuracy of the new algorithm is validated against Monte Carlo calculations. The new algorithm overcomes the deficiency of existing density correction based algorithms in dose calculations for inhomogeneous media, especially for CT-based human volumetric images used in radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Position-probability-sampled Monte Carlo calculation of VMAT, 3DCRT, step-shoot IMRT, and helical tomotherapy dose distributions using BEAMnrc/DOSXYZnrc

Purpose: The commercial release of volumetric modulated arc therapy techniques using a conventional linear accelerator and the growing number of helical tomotherapy users have triggered renewed interest in dose verification methods, and also in tools for exploring the impact of machine tolerance and patient motion on dose distributions without the need to approximate time-varying parameters such as gantry position, MLC leaf motion, or patient motion. To this end we have developed a Monte Carlo-based calculation method capable of simulating a wide variety of treatment techniques without the need to resort to discretization approximations. Methods: The ability to perform complete position-probability-sampled Monte Carlo dose calculations was implemented in the BEAMnrc/DOSXZYnrc user codes of EGSnrc. The method includes full accelerator head simulations of our tomotherapy and Elekta linacs, and a realistic representation of continous motion via the sampling of a time variable. The functionality of this algorithm was tested via comparisons with both measurements and treatment planning dose distributions for four types of treatment techniques: 3D conformal, step-shoot intensity modulated radiation therapy, helical tomotherapy, and volumetric modulated arc therapy. Results: For static fields, the absolute dose agreement between the EGSnrc Monte Carlo calculations and measurements is within 2%/1 mm. Absolute dose agreement between Monte Carlo calculations and treatment planning system for the four different treatment techniques is within 3%/3 mm. Discrepancies with the tomotherapy TPS on the order of 10%/5 mm were observed for the extreme example of a small target located 15 cm off-axis and planned with a low modulation factor. The increase in simulation time associated with using position-probability sampling, as opposed to the discretization approach, was less than 2% in most cases. Conclusions: A single Monte Carlo simulation method can be used to calculate patient dose distribution for various types of treatment techniques delivered with either tomotherapy or a conventional linac. The method simplifies the simulation process, improves dose calculation accuracy, and involves an acceptably small change in computation time.

60 APPLIED LIFE SCIENCES↗

Monte Carlo-based treatment planning system calculation engine for microbeam radiation therapy

Purpose: Microbeam radiation therapy (MRT) is a synchrotron radiotherapy technique that explores the limits of the dose-volume effect. Preclinical studies have shown that MRT irradiations (arrays of 25-75-{mu}m-wide microbeams spaced by 200-400 {mu}m) are able to eradicate highly aggressive animal tumor models while healthy tissue is preserved. These promising results have provided the basis for the forthcoming clinical trials at the ID17 Biomedical Beamline of the European Synchrotron Radiation Facility (ESRF). The first step includes irradiation of pets (cats and dogs) as a milestone before treatment of human patients. Within this context, accurate dose calculations are required. The distinct features of both beam generation and irradiation geometry in MRT with respect to conventional techniques require the development of a specific MRT treatment planning system (TPS). In particular, a Monte Carlo (MC)-based calculation engine for the MRT TPS has been developed in this work. Experimental verification in heterogeneous phantoms and optimization of the computation time have also been performed. Methods: The penelope/penEasy MC code was used to compute dose distributions from a realistic beam source model. Experimental verification was carried out by means of radiochromic films placed within heterogeneous slab-phantoms. Once validation was completed, dose computations in a virtual model of a patient, reconstructed from computed tomography (CT) images, were performed. To this end, decoupling of the CT image voxel grid (a few cubic millimeter volume) to the dose bin grid, which has micrometer dimensions in the transversal direction of the microbeams, was performed. Optimization of the simulation parameters, the use of variance-reduction (VR) techniques, and other methods, such as the parallelization of the simulations, were applied in order to speed up the dose computation. Results: Good agreement between MC simulations and experimental results was achieved, even at the interfaces between two different media. Optimization of the simulation parameters and the use of VR techniques saved a significant amount of computation time. Finally, parallelization of the simulations improved even further the calculation time, which reached 1 day for a typical irradiation case envisaged in the forthcoming clinical trials in MRT. An example of MRT treatment in a dog's head is presented, showing the performance of the calculation engine. Conclusions: The development of the first MC-based calculation engine for the future TPS devoted to MRT has been accomplished. This will constitute an essential tool for the future clinical trials on pets at the ESRF. The MC engine is able to calculate dose distributions in micrometer-sized bins in complex voxelized CT structures in a reasonable amount of time. Minimization of the computation time by using several approaches has led to timings that are adequate for pet radiotherapy at synchrotron facilities. The next step will consist in its integration into a user-friendly graphical front-end.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose calculation for electron therapy using an improved LBR method

Purpose: To calculate the percentage depth dose (PDD) of any irregularly shaped electron beam using a modified lateral build-up ratio (LBR) method.Methods: Percentage depth dose curves were measured using 6, 9, 12, and 15 MeV electron beam energies for applicator cone sizes of 6 Multiplication-Sign 6, 10 Multiplication-Sign 10, 14 Multiplication-Sign 14, and 20 Multiplication-Sign 20 cm{sup 2}. Circular cutouts for each cone were prepared from 2.0 cm diameter to the maximum possible size for each cone. In addition, three irregular cutouts were prepared.Results: The LBR for each circular cutout was calculated from the measured PDD curve using the open field of the 14 Multiplication-Sign 14 cm{sup 2} cone as the reference field. Using the LBR values and the radius of the circular cutouts, the corresponding lateral spread parameter [{sigma}{sub R}(z)] of the electron shower was calculated. Unlike the commonly accepted assumption that {sigma}{sub R}(z) is independent of cutout size, it is shown that its value increases linearly with circular cutout size (R). Using this characteristic of the lateral spread parameter, the PDD curves of irregularly shaped cutouts were calculated. Finally, the calculated PDD curves were compared with measured PDD curves.Conclusions: In this research, it is shown that the lateral spread parameter {sigma}{sub R}(z) increases with cutout size. For radii of circular cutout sizes up to the equilibrium range of the electron beam, the increase of {sigma}{sub R}(z) with the cutout size is linear. The percentage difference of the calculated PDD curve from the measured PDD data for irregularly shaped cutouts was under 1.0% in the region between the surface and therapeutic range of the electron beam. Similar results were obtained for four electron beam energies (6, 9, 12, and 15 MeV)

61 RADIATION PROTECTION AND DOSIMETRY↗

Calculations of two new dose metrics proposed by AAPM Task Group 111 using the measurements with standard CT dosimetry phantoms

Purpose: AAPM Task Group 111 proposed to measure the equilibrium dose-pitch product D-caret{sub eq} for scan modes involving table translation and the midpoint dose D{sub L}(0) for stationary-table modes on the central and peripheral axes of sufficiently long (e.g., at least 40 cm) phantoms. This paper presents an alternative approach to calculate both metrics using the measurements of scanning the standard computed tomographic (CT) dosimetry phantoms on CT scanners.Methods: D-caret{sub eq} was calculated from CTDI{sub 100} and ε(CTDI{sub 100}) (CTDI{sub 100} efficiency), and D{sub L}(0) was calculated from D-caret{sub eq} and the approach to equilibrium function H(L) =D{sub L}(0)/D{sub eq}, where D{sub eq} was the equilibrium dose. CTDI{sub 100} may be directly obtained from several sources (such as medical physicist's CT scanner performance evaluation or the IMPACT CT patient dosimetry calculator), or be derived from CTDI{sub Vol} using the central to peripheral CTDI{sub 100} ratio (R{sub 100}). The authors have provided the required ε(CTDI{sub 100}) and H(L) data in two previous papers [X. Li, D. Zhang, and B. Liu, Med. Phys. 39, 901–905 (2012); and ibid. 40, 031903 (10pp.) (2013)]. R{sub 100} was assessed for a series of GE, Siemens, Philips, and Toshiba CT scanners with multiple settings of scan field of view, tube voltage, and bowtie filter.Results: The calculated D{sub L}(0) and D{sub L}(0)/D{sub eq} in PMMA and water cylinders were consistent with the measurements on two GE CT scanners (LightSpeed 16 and VCT) by Dixon and Ballard [Med. Phys. 34, 3399–3413 (2007)], the measurements on a Siemens CT scanner (SOMATOM Spirit Power) by Descamps et al. [J. Appl. Clin. Med. Phys. 13, 293–302 (2012)], and the Monte Carlo simulations by Boone [Med. Phys. 36, 4547–4554 (2009)].Conclusions: D-caret{sub eq} and D{sub L}(0) can be calculated using the alternative approach. The authors have provided the required ε(CTDI{sub 100}) and H(L) data in two previous papers. R{sub 100} is presented for a majority of multidetector CT scanners currently on the market, and can be easily assessed for other CT scanners or operating conditions not covered in this study. The central to peripheral D{sub eq} ratio is about 1.50 and 1.12 times of R{sub 100} for the 32- and 16-cm diameter PMMA phantom, respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric evaluation of photon dose calculation under jaw and MLC shielding

Purpose: The accuracy of photon dose calculation algorithms in out-of-field regions is often neglected, despite its importance for organs at risk and peripheral dose evaluation. The present work has assessed this for the anisotropic analytical algorithm (AAA) and the Acuros-XB algorithms implemented in the Eclipse treatment planning system. Specifically, the regions shielded by the jaw, or the MLC, or both MLC and jaw for flattened and unflattened beams have been studied.Methods: The accuracy in out-of-field dose under different conditions was studied for two different algorithms. Measured depth doses out of the field, for different field sizes and various distances from the beam edge were compared with the corresponding AAA and Acuros-XB calculations in water. Four volumetric modulated arc therapy plans (in the RapidArc form) were optimized in a water equivalent phantom, PTW Octavius, to obtain a region always shielded by the MLC (or MLC and jaw) during the delivery. Doses to different points located in the shielded region and in a target-like structure were measured with an ion chamber, and results were compared with the AAA and Acuros-XB calculations. Photon beams of 6 and 10 MV, flattened and unflattened were used for the tests.Results: Good agreement between calculated and measured depth doses was found using both algorithms for all points measured at depth greater than 3 cm. The mean dose differences (±1SD) were −8%± 16%, −3%± 15%, −16%± 18%, and −9%± 16% for measurements vs AAA calculations and −10%± 14%, −5%± 12%, −19%± 17%, and −13%± 14% for Acuros-XB, for 6X, 6 flattening-filter free (FFF), 10X, and 10FFF beams, respectively. The same figures for dose differences relative to the open beam central axis dose were: −0.1%± 0.3%, 0.0%± 0.4%, −0.3%± 0.3%, and −0.1%± 0.3% for AAA and −0.2%± 0.4%, −0.1%± 0.4%, −0.5%± 0.5%, and −0.3%± 0.4% for Acuros-XB. Buildup dose was overestimated with AAA, while Acuros-XB gave results more consistent with measurements. From RapidArc plan analysis the average difference between calculation and measurement in the shielded region was −0.3%± 0.4% and −2.5%± 1.2% for AAA and Acuros-XB, respectively, relative to the mean target dose value (1.6%± 2.3%, −12.7%± 4.0% if relative to each local value). These values were compared with the corresponding differences in the target structure: −0.7%± 2.3% for AAA, and −0.5%± 2.3% for Acuros-XB.Conclusions: The two algorithms analyzed showed encouraging results in predicting out-of-field region dose for clinical use.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71

A protocol is presented for the calculation of monitor units (MU) for photon and electron beams, delivered with and without beam modifiers, for constant source-surface distance (SSD) and source-axis distance (SAD) setups. This protocol was written by Task Group 71 of the Therapy Physics Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved by the AAPM for clinical use. The protocol defines the nomenclature for the dosimetric quantities used in these calculations, along with instructions for their determination and measurement. Calculations are made using the dose per MU under normalization conditions, D{sub 0}{sup ′}, that is determined for each user's photon and electron beams. For electron beams, the depth of normalization is taken to be the depth of maximum dose along the central axis for the same field incident on a water phantom at the same SSD, where D{sub 0}{sup ′} = 1 cGy/MU. For photon beams, this task group recommends that a normalization depth of 10 cm be selected, where an energy-dependent D{sub 0}{sup ′} ≤ 1 cGy/MU is required. This recommendation differs from the more common approach of a normalization depth of d{sub m}, with D{sub 0}{sup ′} = 1 cGy/MU, although both systems are acceptable within the current protocol. For photon beams, the formalism includes the use of blocked fields, physical or dynamic wedges, and (static) multileaf collimation. No formalism is provided for intensity modulated radiation therapy calculations, although some general considerations and a review of current calculation techniques are included. For electron beams, the formalism provides for calculations at the standard and extended SSDs using either an effective SSD or an air-gap correction factor. Example tables and problems are included to illustrate the basic concepts within the presented formalism.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Brachytherapy structural shielding calculations using Monte Carlo generated, monoenergetic data

Purpose: To provide a method for calculating the transmission of any broad photon beam with a known energy spectrum in the range of 20–1090 keV, through concrete and lead, based on the superposition of corresponding monoenergetic data obtained from Monte Carlo simulation. Methods: MCNP5 was used to calculate broad photon beam transmission data through varying thickness of lead and concrete, for monoenergetic point sources of energy in the range pertinent to brachytherapy (20–1090 keV, in 10 keV intervals). The three parameter empirical model introduced byArcher et al. [“Diagnostic x-ray shielding design based on an empirical model of photon attenuation,” Health Phys. 44, 507–517 (1983)] was used to describe the transmission curve for each of the 216 energy-material combinations. These three parameters, and hence the transmission curve, for any polyenergetic spectrum can then be obtained by superposition along the lines of Kharrati et al. [“Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities,” Med. Phys. 34, 1398–1404 (2007)]. A simple program, incorporating a graphical user interface, was developed to facilitate the superposition of monoenergetic data, the graphical and tabular display of broad photon beam transmission curves, and the calculation of material thickness required for a given transmission from these curves. Results: Polyenergetic broad photon beam transmission curves of this work, calculated from the superposition of monoenergetic data, are compared to corresponding results in the literature. A good agreement is observed with results in the literature obtained from Monte Carlo simulations for the photon spectra emitted from bare point sources of various radionuclides. Differences are observed with corresponding results in the literature for x-ray spectra at various tube potentials, mainly due to the different broad beam conditions or x-ray spectra assumed. Conclusions: The data of this work allow for the accurate calculation of structural shielding thickness, taking into account the spectral variation with shield thickness, and broad beam conditions, in a realistic geometry. The simplicity of calculations also obviates the need for the use of crude transmission data estimates such as the half and tenth value layer indices. Although this study was primarily designed for brachytherapy, results might also be useful for radiology and nuclear medicine facility design, provided broad beam conditions apply.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the dose calculation at the cellular level and its implications for the RBE of {sup 99m}Tc and {sup 123}I

Purpose: Based on the authors’ previous findings concerning the radiotoxicity of{sup 99m}Tc, the authors compared the cellular survival under the influence of this nuclide with that following exposure to the Auger electron emitter {sup 123}I. To evaluate the relative biological effectiveness (RBE) of both radionuclides, knowledge of the absorbed dose is essential. Thus, the authors present the dose calculations and discuss the results based on different models of the radionuclide distribution. Both different target volumes and the influence of the uptake kinetics were considered. Methods: Rat thyroid PC Cl3 cells in culture were incubated with either{sup 99m}Tc or {sup 123}I or were irradiated using 200 kV x-rays in the presence or absence of perchlorate. The clonogenic cell survival was measured via colony formation. In addition, the intracellular radionuclide uptake was quantified. Single-cell dose calculations were based on Monte Carlo simulations performed using Geant4. Results: Compared with external radiation using x-rays (D{sub 37} = 2.6 Gy), the radionuclides {sup 99m}Tc (D{sub 37} = 3.5 Gy), and {sup 123}I (D{sub 37} = 3.8 Gy) were less toxic in the presence of perchlorate. In the absence of perchlorate, the amount of activity a{sub 37} that was necessary to reduce the surviving fraction (SF) to 0.37 was 22.8 times lower for {sup 99m}Tc and 12.4 times lower for {sup 123}I because of the dose increase caused by intracellular radionuclide accumulation. When the cell nucleus was considered as the target for the dose calculation, the authors found a RBE of 2.18 for {sup 99m}Tc and RBE = 3.43 for {sup 123}I. Meanwhile, regarding the dose to the entire cell, RBE = 0.75 for {sup 99m}Tc and RBE = 1.87 for {sup 123}I. The dose to the entire cell was chosen as the dose criterion because of the intracellular radionuclide accumulation, which was found to occur solely in the cytoplasm. The calculated number of intracellular decays per cell was (975 ± 109) decays/MBq for {sup 99m}Tc and (221 ± 82) decays/MBq for {sup 123}I. Conclusions: The authors’ data indicate that extra-nuclear targets to Auger electrons exist, which is obvious from our dose calculations. When considering the dose to the cell nucleus, the authors found an enhanced RBE for{sup 99m}Tc and {sup 123}I relative to acute x-ray irradiation and pure extracellular irradiation with both radionuclides. Surprisingly, the authors did not find any radionuclide accumulation in the cell nucleus, indicating that there are additional radiosensitive targets besides the DNA. In addition, the authors demonstrated the necessity of cellular dose calculations in radiobiological experiments using unsealed radionuclides and identified the relevant parameters.

60 APPLIED LIFE SCIENCES↗

Fast optimization and dose calculation in scanned ion beam therapy

Purpose: Particle therapy (PT) has advantages over photon irradiation on static tumors. An increased biological effectiveness and active target conformal dose shaping are strong arguments for PT. However, the sensitivity to changes of internal geometry complicates the use of PT for moving organs. In case of interfractionally moving objects adaptive radiotherapy (ART) concepts known from intensity modulated radiotherapy (IMRT) can be adopted for PT treatments. One ART strategy is to optimize a new treatment plan based on daily image data directly before a radiation fraction is delivered [treatment replanning (TRP)]. Optimizing treatment plans for PT using a scanned beam is a time consuming problem especially for particles other than protons where the biological effective dose has to be calculated. For the purpose of TRP, fast optimization and fast dose calculation have been implemented into the GSI in-house treatment planning system (TPS) TRiP98. Methods: This work reports about the outcome of a code analysis that resulted in optimization of the calculation processes as well as implementation of routines supporting parallel execution of the code. To benchmark the new features, the calculation time for therapy treatment planning has been studied. Results: Compared to the original version of the TPS, calculation times for treatment planning (optimization and dose calculation) have been improved by a factor of 10 with code optimization. The parallelization of the TPS resulted in a speedup factor of 12 and 5.5 for the original version and the code optimized version, respectively. Hence the total speedup of the new implementation of the authors' TPS yielded speedup factors up to 55. Conclusions: The improved TPS is capable of completing treatment planning for ion beam therapy of a prostate irradiation considering organs at risk in this has been overseen in the review process. Also see below 6 min.

60 APPLIED LIFE SCIENCES↗

SU-E-T-85: Comparison of Treatment Plans Calculated Using Ray Tracing and Monte Carlo Algorithms for Lung Cancer Patients Having Undergone Radiotherapy with Cyberknife

Purpose: The latest publications indicate that the Ray Tracing algorithm significantly overestimates the dose delivered as compared to the Monte Carlo (MC) algorithm. The purpose of this study is to quantify this overestimation and to identify significant correlations between the RT and MC calculated dose distributions. Methods: Preliminary results are based on 50 preexisting RT algorithm dose optimization and calculation treatment plans prepared on the Multiplan treatment planning system (Accuray Inc., Sunnyvale, CA). The analysis will be expanded to include 100 plans. These plans are recalculated using the MC algorithm, with high resolution and 1% uncertainty. The geometry and number of beams for a given plan, as well as the number of monitor units, is constant for the calculations for both algorithms and normalized differences are compared. Results: MC calculated doses were significantly smaller than RT doses. The D95 of the PTV was 27% lower for the MC calculation. The GTV and PTV mean coverage were 13 and 39% less for MC calculation. The first parameter of conformality, as defined as the ratio of the Prescription Isodose Volume to the PTV Volume was on average 1.18 for RT and 0.62 for MC. Maximum doses delivered to OARs was reduced in the MC plans. The doses for 1000 and 1500 cc of total lung minus PTV, respectively were reduced by 39% and 53% for the MC plans. The correlation of the ratio of air in PTV to the PTV with the difference in PTV coverage had a coefficient of −0.54. Conclusion: The preliminary results confirm that the RT algorithm significantly overestimates the dosages delivered confirming previous analyses. Finally, subdividing the data into different size regimes increased the correlation for the smaller size PTVs indicating the MC algorithm improvement verses the RT algorithm is dependent upon the size of the PTV.

60 APPLIED LIFE SCIENCES↗