Calculation of dose decrease in a finite phantom of a {sup 192}Ir point source

Abstract

The purpose of this study was to calculate the dose decrease in a finite phantom of a {sup 192}Ir-point source by using a new algorithm based on field theory. The methods used included the phenomenological application of the principle 'mirror image of an electric point source in front of a dielectric semi-plateau' to a radioactive source in a finite phantom results in a function to calculate the dose decrease near the surface. Measurements were done in a water phantom in three different experimental setups. To verify the calculated results Monte Carlo (MC) simulations of dose distribution of a {sup 192}Ir point source in 34x40x40 cm{sup 3} water were carried out. The strength of mirror source was found -0.103 of the real source. A lack scatter function was necessary to handle the dose decrease very close to surface. The measured and calculated dose values differed less than 0.9%. Both MC simulations and the new algorithm show the dose decrease near phantom surface with differences less than 2% between each other. The new algorithm based on field theory calculated the dose decrease of a {sup 192}Ir point source in a finite phantom with a very good agreement to measured and simulated data. A clinical example, which affects only a single planar boundary, is given by using molds in the treatment of skin tumors. This was calculated with the new algorithm presented in this article. The comparison with the common algorithm demonstrates the differences that might cause an overestimation of the dose, which probably leads an underdosing of the tumor. The general use of the new algorithm in brachytherapy where a variety of boundary shapes are encountered has to be verified seriously.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Melchert, Corinna, Kohr, P, Schmidt, R. 2007-10-15. Calculation of dose decrease in a finite phantom of a {sup 192}Ir point source. https://doi.org/10.1118/1.2775664. https://engineeringpapers.com/record/osti%3A21032810/calculation-of-dose-decrease-in-a-finite-phantom-of-a-sup-192-ir-point-source

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Engineering Papers by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Cross sections of 147–149 Sm( 6 Li,x) reactions for the production of 149 Tb for targeted alpha therapy

Terbium-149g (t 1/2 = 4.12 h) is of particular interest for targeted alpha therapy cancer treatment due to its ability to decay via both alpha and positron emission, making it a potential theranostic nuclide. Due to many challenges facing its production, there are limited facilities worldwide that have demonstrated the ability to produce this nuclide in quantities sufficient for medical research. Since the Cyclotron Institute at Texas A&M University is a specialized accelerator facility capable of accelerating a wide variety of ions, we are investigating production pathway options. One of the major challenges facing its production is the known co-production of the excited isomeric state, 149m Tb (t 1/2 = 4.1 min). However, this state does not decay to the ground state of 149g Tb, negating any potential contribution to its yield. Due to its short-half life, the cross section for the population of this state has never been measured. After calculating several potential reaction yields using predictive models, the reactions of 147–149 Sm( 6 Li,xn) 149 Tb were identified as candidates. Lithium-6 beams of varied energies between 45-65 MeV were impinged on enriched 147 Sm, 148 Sm, and 149 Sm targets at the Cyclotron Institute at Texas A&M University, and the reaction products were measured immediately following irradiation using high-purity germanium detectors, enabling detection of both 149m Tb and 149g Tb. Cross sections for all nuclides produced in sufficient activity in these reactions were also measured and reported here. We conclude that the population of 149m Tb is much preferred over population of the ground state for these 6 Li-induced reactions, and it is necessary to explore other options for 149g Tb production.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Source function from two-particle correlation function through entropy-regularized Richardson-Lucy deblurring

Source functions are obtained from p – p and d – α correlation functions by applying the Richardson-Lucy (RL) deblurring to the Koonin-Pratt (KP) equation. To prevent fitting of noise in the correlation function, total-variation (TV) regularization is employed that has been effective in ordinary image restoration. TV alone cannot ensure normalization of the source functions. To ensure the latter, we propose a maximum-entropy regularized RL algorithm (MEM-RL). We outline the MEM-RL formalism and optimization strategy for the KP equation, demonstrating its effectiveness on both simulated and experimental data, including the p – p and d – α correlation functions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗