ATM CMG bearing failure analysis

The cause or causes for the failure of ATM CMG S/N 5 (Skylab 1) and the anomalies associated with ATM CMG S/N 6 (Skylab 2) were investigated. Skylab telemetry data were reviewed and presented in the form of parameter distributions. The theory that the problems were caused by marginal bearing lubrication was studied along with the effects of orbital conditions on lubricants. Bearing tests were performed to investigate the effect of lubricant or lack of lubricant in the ATM CMG bearings and the dispersion and migration of the lubricant. The vacuum and weightless conditions of space were simulated in the bearing tests. Analysis of the results of the tests conducted points to inadequate lubrication as the predominant factor causing the failure of ATM CMG S/N 5 (Skylab 1) and the anomalies associated with ATM CMG S/N 6 (Skylab 2).

Source record↗

Evaluation program for secondary spacecraft cells

The cycle life tests to determine the performance capabilities of packs of cells under different loads and temperature conditions are reported. Results are summarized, and the failure of 14 failed cells is analyzed. It was found that the main cause of failure was separator deterioration and migration of the negative plate material.

Harkness, J. D.↗

Evaluation of ERTS-1 data for certain hydrological uses

The author has identified the following significant results. ERTS-1 MSS data have been used in a variety of hydrologic research including snow-extent mapping; studies of snowmelt, snowmelt runoff, spectral reflectance of snow for assessing snowpack conditions, and snow albedo; lake ice formation, breakup, and migration; lake current measurements; multispectral studies of lake ice; and flood studies. MSS sensing of soil moisture over a well-vegetated test site was unsuccessfully attempted. Although a powerful research tool, ERTS-1 has very limited use as an operational system for hydrologic communities because of its 18-day revisit cycle and its lack of a quick look capability.

Wiesnet, D. R.↗

The Effect of a Planetary Surface Penetrator on the Soil Column Surrounding the Impacting Body

A prototype penetrator instrument was impacted into a dry lake bed. Laboratory studies of the soil surrounding the penetrator revealed that the soil was contaminated by paint and metal from the penetrator's casing. Paint pigment rich in titanium and sulfur was found in the adjacent soil. The highly mobile paint pigment migrated onto viewing ports in the penetrator's exterior. Bulk analysis of the soil adjacent to the impactor showed a significant increase in both elements, as well as the presence of metal chips from the casing and nose cone. It is recommended that great care be taken in the use of coating materials and the metal alloys selected for the penetrator's exterior, or the accuracy of any experiment requiring an uncontaminated in situ sample may be adversely affected.

Blanchard, Maxwell B.↗

Fate in humans of the plasticizer, DI (2-ethylhexyl) phthalate, arising from transfusion of platelets stored in vinyl plastic bags

Platelet concentrates were shown to contain 18-38 mg/100 ml of a phthalate plasticizer (DEHP) which arose by migration from the vinyl plastic packs in which the plateletes were prepared and stored. Transfusion of these platelets into 6 adult patients with leukemia resulted in peak blood plasma levels of DEHP ranging from 0.34 - 0.83 mg/100 ml. The blood levels fell mono-exponentially with a mean rate of 2.83 percent per minute and a half-life of 28.0 minutes. Urine was assayed by a method that would measure unchanged DEHP as well as all phthalic acid-containing metabolities. In two patients, at most 60 and 90% of the infused dose, respectively, was excreted in the urine collected for 24 hours post-transfusion. These estimates, however, could be high due to the simultaneous excretion of DEHP remaining from previous transfusions or arising from uncontrolled environmental exposures.

Rubin, R. J.↗

An X-ray photoelectron spectroscopy study of nickel and nickel-base alloy surface alterations in simulated hot corrosion conditions with emphasis on eventual application to turbine blade corrosion

The spectra of the pure metals tested and their oxides were used to analyze the patterns obtained for various superalloys. The quantitative results for two superalloys revealed differences between the surface compositions and their behavior under different conditions of oxidation. The following results occurred during the hot corrosion of samples in the presence of Na2So4: a lack of Ti migration; strong effects on Cr; and, a higher speed of alteration of superalloys.

Mateescu, G. D.↗

The electrical performance of Ag Zn batteries for the Venus multi-probe mission

An evaluation of 5 Ah and 21 Ah Silver-Zinc batteries was made to determine their suitability to meet the energy storage requirements of the bus vehicle, 3 small probes and large probe for the Venus multi-probe mission. The evaluation included a 4 Ah battery for the small probe, a 21 Ah battery for the large probe, one battery of each size for the bus vehicle power, a periodic cycling test on each size battery and a wet stand test of charged and discharged cells of both cell designs. The study on the probe batteries and bus vehicle batteries included both electrical and thermal simulation for the entire mission. The effects on silver migration and zinc penetration of the cellophane separators caused by the various test parameters were determined by visual and X-ray fluorescence analysis. The 5 Ah batteries supported the power requirements for the bus vehicle and small probe. The 21 Ah large probe battery supplied the required mission power. Both probe batteries delivered in excess of 132 percent of rated capacity at the completion of the mission simulation.

Palandati, C.↗

Diurnal stratospheric tide in meridional wind, 30 to 60 KM, by season and monthly mean temperatures, 20 to 60 KM, at 80 deg N and to 0 deg N

The diurnal component in meridional wind was observed for each season at twelve rocket stations. Amplitudes and phases are presented as a function of height-latitude or as vertical profiles. Many of the gross features of the tide persist throughout the year, but as they migrate in height and latitude the amplitude or phase at a given location may undergo large changes with season. Longitudinal variations in the diurnal tide are found in the mid-stratosphere, and it is suggested they are coupled with longitudinal variations in the tropospheric temperature structure.

Nastrom, G. D.↗

Io - A surface evaporite deposit

A model is suggested for Io's surface composition involving evaporite salt deposits, rich in sodium and sulfur. According to this model, these deposits were produced as a result of the migration of salt-saturated aqueous solutions to Io's surface from a warm or hot interior followed by loss of the water to space. This model satisfies cosmochemical constraints based on Io's initial composition, current density, and thermal history. Salt-rich assemblages are easily derivable from the leaching of carbonaceous chondritic material. The chemical and optical properties of such deposits, after modification by irradiation, can be used to explain Io's overall albedo and spectral reflectance, its dark reddish poles, and the observed sodium emission as well as or better than other currently suggested materials.

Fanale, F. P.↗

A theory for predicting composite laminate warpage resulting from fabrication

Linear laminate theory is used in conjunction with the moment-curvature relationship to derive equations for predicting end deflections due to warpage without solving the coupled fourth-order partial differential equations of the plate. Using these equations, it is found that a 1 deg error in the orientation angle of one ply is sufficient to produce warpage end deflection equal to two laminate thicknesses in a 10 inch by 10 inch laminate made from 8-ply Mod-I/epoxy. From a sensitivity analysis on the governing parameters, it is found that a 3 deg fiber migration or a void volume ratio of three percent in some plies is sufficient to produce laminate warpage corner deflection equal to several laminate thicknesses. Tabular and graphical data are presented which can be used to identify possible errors contributing to laminate warpage and/or to obtain an a priori assessment when unavoidable errors during fabrication are anticipated.

Chamis, C. C.↗

On the exposure history of the lunar regolith

The observed minimum and mean values of track densities in lunar grains are both found to exceed the values expected from exposure with redistribution by vertical mixing, and the percentage of the smaller grains showing very high track densities is too large by a factor of more than ten. Previous exposure of the material (in space before accretion onto the moon or in regions from which net migration has occurred) may be necessitated.

Gold, T.↗

The response of single human cells to zero gravity

Twenty separate cultures of Wistar-38 human embryonic lung cells were exposed to a zero-gravity environment on Skylab for periods of time ranging from one to 59 days. Duplicate cultures were run concurrently as ground controls. Ten cultures were fixed on board the satellite during the first 12 days of flight. Growth curves, DNA microspectrophotometry, phase microscopy, and ultrastructural studies of the fixed cells revealed no effects of a zero-gravity environment on the ten cultures. Two cultures were photographed with phase time lapse cinematography during the first 27 days of flight. No differences were found in mitotic index, cell cycle, and migration between the flight and control cells. Eight cultures were returned to earth in an incubated state. Karyotyping and chromosome banding tests show no differences between the flight and control cells.

Montgomery, P. O., Jr.↗

Specific-ion electrodes for measuring Ag ions

Migration of aqueous solutions through electrode pellet, and thus corrosion of soldered connection, is prevented by coating pellet and silver wire attachment with silver-conductive epoxy.

Day, J. L.↗

Composite laminate warpage

Set of simplified equations predicts warpage that often occurs upon removal from fabrication mold. Equations predict corner deflection and are based upon micromechanics and macromechanics of composites, as well as laminate theory. Factors considered include ply misorientation, fiber migration, and void/volume ratio nonuniformity.

Chamis, C. C.↗

Design guidelines for hybrid microcircuits; organic adhesives for hybrid microcircuits

The properties of organic adhesives were studied to acquire an adequate information base to generate a guideline document for the selection of adhesives for use in high reliability hybrid microcircuits. Specific areas covered include: (1) alternate methods for determining the outgassing of cured adhesives; (2) effects of long term aging at 150C on the electrical properties of conductive adhesives; (3) effects of shelf life age on adhesive characteristics; (4) bond strengths of electrically conductive adhesives on thick film gold metallization, (5) a copper filled adhesive; (6) effects of products outgassed from cured adhesives on device electrical parameters; (7) metal migration from electrically conductive adhesives; and (8) ionic content of electrically insulative adhesives. The tests performed during these investigations are described, and the results obtained are discussed in detail.

Perkins, K. L.↗

The effects of space flight on polymorphonuclear leukocyte response experiment MA-032

In a series of studies performed at intervals from 30 day before flight to 30 days after recovery, blood samples were obtained from the three astronauts of the Apollo Soyuz Test Project and from eight control subjects. To determine the effects of space flight on polymorphonuclear leukocytes, tests were performed on blood samples obtained as quickly as possible after splashdown and on the day following recovery. The astronauts' inhalation of propellant gases and the inception of corticosteroid therapy 1 day after recovery provided an additional opportunity to investigate the possible effects of these factors on leukocyte function. Data were obtained during each time period on the total leukocyte count, differential count, leukocyte adhesion, leukocyte migration and chemotaxis, phagocytosis, and histochemical staining for leukocyte acid and alkaline phosphatase. These observations present a variety of in vitro correlates to white blood cell function within the body. Taken together, they serve as a reasonable approximation of the effects of space flight on leukocyte function.

Martin, R. R.↗

Electrophoresis technology experiment MA-011

Experiment MA-011, electrophoresis technology, was designed to test electrophoresis hardware that would continue the development of technology for electrophoretic separation of materials in the near zero g environment of space. The experimental hardware generally functioned as planned. Frozen live cells were successfully transported into space, electrophoretic processing was performed, and viable cells were returned to earth. A separation of the three types of fixed red blood cells (rabbit, human, and horse) was demonstrated. The human lymphocytes, however, showed no apparent migration. The separation of human kidney cells produced the most exciting data. Analysis shows electrophoretic separation throughout the entire column with at least four bands of viable cells. The isotachophoresis experiment definitely demonstrated the isotachophoretic separation of biological cells in a near zero g environment.

Allen, R. E.↗

Rechargeable battery which combats shape change of the zinc anode

A rechargeable cell or battery is provided in which shape change of the zinc anode is combatted by profiling the ionic conductivity of the paths between the electrodes. The ion flow is greatest at the edges of the electrodes and least at the centers, thereby reducing migration of the zinc ions from edges to the center of the anode. A number of embodiments are disclosed in which the strength and/or amount of electrolyte, and/or the number and/or size of the paths provided by the separator between the electrodes, are varied to provide the desired ionic conductivity profile.

Cohn, E. M.↗