Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CoSTA)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Multiphoton and Harmonic Imaging of Microarchitected Materials

Microadditive manufacturing has revolutionized the production of complex, nano- to microscale components across various fields. This work investigates two-photon (2P) and three-photon (3P) fluorescence imaging, as well as third-harmonic generation (THG) microscopy, to examine periodic microarchitected lattice structures fabricated using multiphoton lithography (MPL). By immersing the structures in refractive index matching fluids, we demonstrate high-fidelity 3D reconstructions of both fluorescent structures using 2P and 3P microscopy as well as low-fluorescence structures using THG microscopy. These results show that multiphoton fluorescence (MPF) imaging offers reduced signal decay with respect to depth compared to single-photon techniques in the examined structures. We further demonstrate the ability to nondestructively identify intentional internal modifications of the structure that are not immediately visible with scanning electron microscope (SEM) images and compression-induced fractures, highlighting the potential of these techniques for quality control and defect detection in microadditively manufactured components.

36 MATERIALS SCIENCE↗

Understanding the Dissolution and Passivation of an Aluminum Electrode during Electrocoagulation of Groundwater Using Neutron and X-ray Reflectometry

An aluminum (Al)-based electrocoagulation (EC) system can effectively remove dissolved silica and hardness in groundwater. The effectiveness of Al-EC in terms of pollutant removal, Faradaic efficiency, and energy consumption depends on the interfacial electrolysis or passivation of the electrode in water. Thus, understanding the electrolysis reaction at the liquid/electrode interface during operation is important for sustainable EC deployment. Here, a continuous flow-through Al-EC system was tested with various groundwater simulants, i.e., chloride (Cl – )-based, sulfate (SO 4 2– )-based, and mixed solutions. High pollutant removal with low energy consumption was observed in Cl – -based groundwater treatment, while low pollutant removal with high energy consumption was observed in SO 4 2– -based groundwater. For example, the required energy per unit mass of Al dosing in SO 4 2– -based groundwater is three times higher than that in Cl – -based groundwater at 10 mA/cm 2 . However, increasing the Cl – concentration significantly reduces this energy demand. In SO 4 2– -based groundwater, the silicate removal efficiency drops from 85.1% to 24.0% compared to that for Cl – -based groundwater, while Mg 2+ and Ca 2+ removal efficiencies decrease to 0.6% from 15.8% and 5.7% from 44.8%, respectively. To better understand this EC performance, we used in situ neutron reflectometry (NR) to examine the interfacial dynamics of Al dissolution and passivation at a 100 nm scale occurring on the surface of the sacrificial Al electrodes during EC. Ex situ X-ray reflectometry (XRR) was also used to support the in situ NR results. Both NR and XRR results revealed that Al dissolution is influenced by the presence of Cl – in the simulants, while a passivating layer forms on the electrode in a SO 4 2– -based solution. In the Cl – -based solution, anodic Al dissolution occurred locally and inhomogeneously across the surface of the Al anode film, resulting in a localized thickness reduction over time. In the SO 4 2– -based solution, no apparent dissolution of the Al anode was identified. Instead, Al underwent oxidation, forming an amorphous Al 2 O 3 surface layer within the Al electrode film that increased in thickness over time. In the mixed solution, both anodic Al dissolution and surface Al 2 O 3 layer formation occurred, indicating that Al dissolution and surface Al 2 O 3 layer formation are attributable to the Cl – and SO 4 2– ions, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum Sensing in Micro-Architected Scaffolds

Quantum sensing with nitrogen-vacancy centers in diamond has emerged as a powerful tool for measuring diverse physical parameters, yet the versatility of these measurement approaches is often limited by the achievable layout and dimensionality of bulk-crystal platforms. Here, in this study, we demonstrate a versatile approach to creating designer quantum sensors by surface-functionalizing multiphoton lithography microstructures with NV-containing nanodiamonds. We showcase this capability by fabricating a 150 μm × 150 μm × 150 μm triply periodic minimal surface gyroid structure with millions of attached nanodiamonds. We demonstrate a means to volumetrically image these structures using a refractive index matching confocal imaging technique and extract ODMR spectra from 1.86 μm × 1.86 μm areas of highly concentrated nanodiamonds across a cross-section of the gyroid. Furthermore, the high density of sensing elements enables ensemble temperature measurements with a sensitivity of 0.548 ± 0.084 K/√Hz at 5 mW excitation power. This approach to creating quantum-enabled microarchitectures opens new possibilities for multimodal sensing in complex three-dimensional environments.

Materials science↗

DeSelenator: A Se-Removal Process for Environmental Decontamination of Wastewaters from Coal-Burning Power Plants

Selenium may become a toxic contaminant of freshwater systems when released into the environment through industrial wastewaters from mining, coal-burning power plants, or oil refining. Efficient and cost-effective Se-removal technologies are therefore necessary to reduce Se concentrations in these wastewaters to below the regulatory discharge limits. In this study, we have demonstrated an effective process that removes Se, mostly as selenate anions, from wastewaters generated by coal-burning power plants. This process, dubbed DeSelenator, leverages the high concentration of sulfate relative to selenate in the wastewater and the propensity of these oxyanions to cocrystallize with benzene-bis-iminoguanidinium (BBIG) cations into extremely insoluble salts (on par with BaSO 4 ). The SO 4 2− /SeO 4 2− cocrystallization with BBIG removes over 90% of S and Se from the wastewater. Following removal of the precipitate by filtration, the filtrate is passed over an anion-exchange resin that further reduces selenium concentration to 5 ppb, the EPA’s regulatory limit for freshwater systems. Finally, the effluent is passed over an activated carbon column, which removes 99.8% of the residual BBIG ligand remaining after crystallization, allowing for the safe discharge of the treated water into the environment. The Se-removal process was first optimized in the lab at the bench scale and then tested in the field at the Tennessee Valley Authority’s Bull Run coal-burning power plant. A technoeconomic assessment found the cost of water treatment with DeSelenator is on par with that of the active biological method, which is currently considered a state-of-the-art Se-removal technology.

anions↗

Electroprecipitation Mechanism Enabling Silica and Hardness Removal through Aluminum-Based Electrocoagulation

We evaluate the effectiveness of an aluminum-based electrocoagulation pretreatment system to remove dissolved silica and hardness. Silica and hardness limit water recovery during membrane-based desalination applications when silica and hardness exceed the solubility limit and generate scale on the membrane surface. We show that simultaneous removal of nearly all silica (95 ± 4%) and a significant amount of hardness (40–60%) occurs with a hydraulic residence time of 2 h and a charge loading between 0 and 1200 C/L. Increasing the residence time maximized the hardness removal (58 ± 8%) via the formation of larger flocs, which allowed for more constituent removal by gravity settling. We highlight the trade-offs between improved energy efficiency at lower charge loadings and an improved removal rate at a higher charge loading. We further compare the percentage of silica and hardness removed in multicomponent solutions and compare this to single component feed solution. We discuss the implications that operational considerations have in terms of cost and treatment capacity. Finally, a cost–benefit analysis comparing chemical coagulation with electrocoagulation indicates that electrocoagulation could be half the cost of chemical coagulation and could produce more stable effluent pH and conductivity.

36 MATERIALS SCIENCE↗

Porous Iron Electrodes Reduce Energy Consumption During Electrocoagulation of a Virus Surrogate: Insights into Performance Enhancements Using Three-Dimensional Neutron Computed Tomography

Electrocoagulation has attracted significant attention as an alternative to conventional chemical coagulation because it is capable of removing a wide range of contaminants and has several potential advantages. In contrast to most electrocoagulation research that has been performed with nonporous electrodes, in this study, we demonstrate energy-efficient iron electrocoagulation using porous electrodes. In batch operation, investigation of the external pore structures through optical microscopy suggested that a low porosity electrode with sparse connection between pores may lead to mechanical failure of the pore network during electrolysis, whereas a high porosity electrode is vulnerable to pore clogging. Electrodes with intermediate porosity, instead, only suffered a moderate surface deposition, leading to electrical energy savings of 21% and 36% in terms of electrocoagulant delivery and unit log virus reduction, respectively. Neutron computed tomography revealed the critical role of electrode porosity in utilizing the electrode’s internal surface for electrodissolution and effective delivery of electrocoagulant to the bulk. Energy savings of up to 88% in short-term operation were obtained with porous electrodes in a continuous flow-through system. Further investigation on the impact of current density and porosity in long-term operation is desired as well as the capital cost of porous electrodes.

42 ENGINEERING↗

Electrocoagulation Combined with Ultrafiltration Membranes as Pretreatment for RO Desalination of Synthetic Cooling Tower Blowdown Water

Electrocoagulation (EC), an electrochemical water treatment process, is commonly used to remove particulate and colloidal matter from water. Here, in this study, we demonstrate that EC, when coupled with membrane filtration, is also capable of removing dissolved species, such as Ca + , Mg 2+ , and SiO x . The removal of such species is important for downstream membrane-based desalination treatment of the water that can suffer from reduced performance due to membrane scaling. Here, we describe how EC can be combined with a low-pressure membrane (LPM) system to offer efficient (and potentially universal) pretreatment for downstream membrane desalination. Synthetic water, simulating cooling tower blowdown (CTBD) with elevated concentrations of hardness and silicates (Ca: 418 ppm, Mg: 63 ppm, SiO 2 : 50 ppm) is treated using EC coupled to ultrafiltration (UF) to remove Mg up to 30 ± 1%, Ca up to 29 ± 1%, and silica up to 99 ± 1%. We evaluated the effectiveness of the EC-UF pretreatment system in reducing downstream RO scaling using thermodynamic modeling to predict the saturation index (SI) at the RO membrane/water interface. An SI value below zero (SI < 0) indicates under-saturated conditions (with respect to a particular mineral) where mineral scaling does not take place, which correlates with improved water recovery. Our findings suggest that the EC-UF pretreatment system was able to increase water recovery by up to 30%, compared to 0% recovery without pretreatment, under optimal conditions (feed solution pH of 7 and an EC charge loading of 1800 C/L). Finally, we conducted an economic analysis showing that implementing an EC-UF system for CTBD water could yield a cost benefit of up to $\$$14.13 per m 3 compared to direct brine disposal.

cooling tower blowdown↗

Physical and Electrochemical Characterization of Aluminum Electrodes during Electrocoagulation

Electrocoagulation (EC) of synthetic groundwater was conducted using a sacrificial aluminum electrode in a flow-through EC reactor with short retention times (<1 min) under varying hydrodynamic and electrochemical conditions. The treated water was allowed to settle for 24 h and achieved silicate removal of up to 50 ± 4%, and hardness removal of 11 ± 1%. Physical, chemical, and electrochemical characterization was performed to explore changes in electrode surface morphology and composition. Electrochemical impedance spectroscopy (EIS) showed that chemical reactions at the electrode/water interface are sensitive to changes in the immediate chemical environment. We demonstrate that the most energy-intensive step in EC is aluminum dissolution at the anode, which remained fairly constant due to the continuous renewal of the anode’s surface, a result of aluminum dissolution. At the cathode, a structural change in the oxide layer, from γ-Al 2 O 3 to gibbsite, was detected by grazing-incidence X-ray diffraction, which decreased the resistance to charge transfer at the cathode surface, resulting in decreased electrode resistance. The high flow rate in the system minimized the accumulation of aluminum hydroxide solids and aluminum ions at the electrode/water interface, which minimized the formation of thick scalants and amorphous Al(OH) 3 on the cathode and anode, respectively. In conclusion, it was further demonstrated by EIS that under these conditions the resistance to charge transfer was constant throughout the duration of the experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance Restoration of Iron Electrodes by Polarity Reversal after Long-Term Surface Fouling in Wastewater Electrocoagulation

Iron electrocoagulation (Fe-EC) performance often declines with time, producing lower contaminant removal efficiencies and higher energy requirements due to formation of a fouling layer on the electrodes. Here, we investigate the formation of the fouling layer and the effectiveness of polarity reversal to restore the Fe-EC performance. A thin, porous iron oxide layer initially forms on the anode, thickening into a dense, over 150-μm thick crystalline layer after extended operation. This fouling layer restricts dissolution and diffusion of Fe ions into the bulk solution, thus increasing the anode potential required to maintain a desired electrical current and decreasing Faradaic efficiency. Polarity reversal applied when performance decline is observed effectively removes the fouling layer, thereby restoring Faradaic and contaminant removal efficiencies and decreasing energy consumption. Our findings suggest that gas generation at the cathode surface after polarity reversal causes removal of the fouling layer. This study enhances the current understanding of fouling-layer formation in Fe-EC and offers a practical approach, involving polarity reversal, to maintain electrode reactivity and optimal Fe-EC performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Removal of Selenium Oxyanions from Aqueous Solutions by Ion Exchange: Equilibrium, Kinetics, and Mechanistic Modeling

Selenium (Se) is an essential micronutrient but toxic at high concentrations, posing challenges for water treatment. This study investigated the removal of selenate (SeO 4 2– ) and selenite (SeO 3 2– ) using the strong-base anion-exchange resin IRA-900, particularly in the presence of competing sulfate (SO 4 2– ). The performance of the commercially available resin IRA-900 was systematically investigated. The batch equilibrium behavior was studied in both single- and binary-component systems, and the kinetic behavior was investigated in single-component systems. Results confirmed a selectivity order of SeO 4 2– > SO 4 2– > SeO 3 2– , indicating preferential SeO 4 2– removal over competing SO 4 2– but lower affinity for SeO 3 2– . The maximum total exchange capacity was determined to be 2.04 mequiv/g. Furthermore, SeO 3 2– uptake was found to be pH-dependent, whereas SeO 4 2– uptake remained stable across a broad pH range. From a modeling perspective, the Law of Mass Action model effectively described equilibrium data, and a transport–reaction modeling framework captured removal kinetics of oxyanions including film and intraparticle diffusion. Finally, X-ray photoelectron spectroscopy confirmed ion exchange between chloride and Se oxyanions as the primary removal mechanism. These findings provide fundamental insights into the removal of Se oxyanions from aqueous solutions by ion exchange.

IRA-900↗

Removal of Calcium and Silica from Simulated Blowdown Water Using CO 2 -Assisted Magnesium Electrocoagulation

Blowdown water from various industries and cooling facilities contains high concentrations of calcium (Ca), magnesium (Mg), silica, and corrosion inhibitors, which render the water unsuitable for discharge into surface water and wastewater treatment plants. Electrocoagulation (EC) is effective at removing Ca and silica. Here, in this study, Mg-alloy electrodes EC resulted in ∼91% silica removal at a 5400 C/L charge loading. Ca removal, however, was only 31%. To enhance Ca removal, carbon dioxide (CO 2 ) containing gas was introduced. CO 2 addition formed carbonate ions, which reacted with Ca/Mg ions to generate carbonate precipitates. Introducing 5% and 14% CO 2 , simulating natural gas-fired and coal-fired flue gas, enhanced Ca removal to 38% and 47%, respectively. Pure CO 2 facilitated 70% Ca removal, more than two times higher than that without CO 2 , while maintaining high silica removal. FTIR, XRD, and SEM-EDS analyses confirmed enhanced Ca/Mg carbonate formation upon CO 2 . In situ Raman spectroscopy was employed to monitor carbonate-ions formation. The results demonstrated carbonate-ions removal through Ca-carbonate formation after CO 2 addition. A techno-economic assessment showed that recycled electrode materials and flue gas lead to ∼3 times lower cost compared with conventional silica/Ca removal through chemical coagulation, softening, or membrane filtration. The study demonstrated that CO 2 addition removes high concentrations of Ca and silica ions from wastewaters at a competitive cost.

blowdown water↗

Electrocoagulation in Water Treatment: Targeted Contaminant Removal and Laboratory Best Practices

Electrocoagulation for water treatment offers many advantages over traditional treatment technologies, including improved energy efficiency and modularity. One challenge with electrocoagulation is the lack of standardization in the methodology and reporting. This review provides a novel contribution by examining the past literature using a uniform metric (charge loading) as a basis for comparison, highlighting the importance of uniform reporting practices in this field. Furthermore, this review provides practical guidance for experimentalists in standardizing the electrocoagulation design and operating procedures. First, we present a comprehensive overview of contaminant-specific electrocoagulation as an electrochemical treatment technology for processing industrial, municipal, and agricultural water, with a focus on aluminum and iron electrocoagulation. We detail the fundamental mechanisms that allow for constituent removal during pretreatment. Specifically, we highlight electrocoagulation’s potential for organics, metalloids, microbes, and hardness remediation, examining the optimal removal conditions in terms of charge loading and current density. We conclude this work with some experimental best practices for lab-scale electrocoagulation experiments.

aluminum↗

Treatment of Lagoon Dairy Manure Wastewater via Iron Electrocoagulation, Microfiltration, and Adsorption

Dairy manure wastewater generated by flushing barn cow waste contains nutrients, pathogens, and organic and inorganic contaminants. This study utilized a process consisting of iron electrocoagulation (Fe-EC), microfiltration (MF), and activated carbon (AC) adsorption to treat farm wastewater and explore the reclamation of clean water for irrigation and livestock consumption. Significant removal (>99.9%) of chemical oxygen demand (COD), total organic carbon (TOC), phosphorus (P), turbidity, and microorganisms, as well as ions including magnesium, calcium, sulfur, and silica was achieved by the combined EC-MF-AC process. Specifically, a charge loading of ∼37,500 C/L in a continuous-flow EC configuration, followed by MF, achieved more than 95% removal of TOC and COD. Characterization of produced flocs and foam via scanning-electron microscopy with energy-dispersal spectroscopy and Fourier transform infrared spectroscopy confirmed the removal of ions, including calcium, sulfur, and silica. A key finding was the electrocatalytic conversion of nitrogen species to ammonia gas through the intermediate reduction of nitrate/nitrite, which led to ∼60% total nitrogen (TN) removal. AC treatment further improved TN removal to ∼70%. The Fe-EC process also eradicated >99.9% of bacteria. Preliminary process cost assessment, based on recycled materials for EC electrodes, showed significant cost savings (∼2 times) compared to commercial electrodes.

Dutta, Swapnamoy [ORNL]↗

Ultrafast Nanoimaging of Carrier Funneling in Composition-Graded Semiconductor Nanowires

Recent advances in bandgap engineering of low-dimensional semiconductors have enabled high-efficiency carrier transport in miniaturized electronic and optoelectronic devices. The physical properties and functionalities of these materials are governed by complex carrier dynamics coupled with multiple transport mechanisms in tailored band structures. Here, we report ultrafast nanoimaging of carrier funneling and recombination in composition-grade CdSxSe1-x nanowires using pump-probe near-field nanoscopy. Leveraging the high resolution of this technique in both space and time, we resolve nanoscale local carrier dynamics along composition-graded nanowires, revealing the local variation of composition-dependent carrier mobilities and lifetimes that significantly differ from their uniform composition counterparts. Furthermore, we demonstrate a length-dependent behavior wherein shorter nanowires exhibit enhanced funneling effects, accelerating carrier transport by up to 33%. Our findings provide direct visualization of nanoscale carrier transport while supporting an effective approach for investigating complex carrier interactions in inhomogeneous semiconductor nanostructures, with implications for optimizing next-generation optoelectronic devices.

Yang, Rundi↗

Hydrogen Production from Polyethylene Pyrolysis

Hydrogen is anticipated to play a pivotal role in the future of clean energy and decarbonization efforts, serving as an energy storage medium, a power generation source, and a clean fuel for transportation. While most hydrogen is produced from carbonaceous fossil feedstocks like natural gas, petroleum, and coal, there is growing interest in using refuse-derived fuels such as waste plastics and municipal solid waste (MSW) as alternative feedstocks. Thermochemical processes such as pyrolysis and catalytic cracking can convert nonrecyclable plastics and organic MSW components to produce hydrogen with lower life cycle greenhouse gas emissions when coupled with CO 2 capture. Such approaches not only address waste-management challenges but also reduce methane emissions from landfills. Furthermore, waste feedstocks are low cost and can support meeting demands for hydrogen across various industries. In this work we examined production of hydrogen from high-density polyethylene (HDPE) as a model polymer using pyrolysis. Analytical studies of pyrolysis utilizing gas chromatography–mass spectrometry (GC/MS) provide insights into conversion pathways for plastic waste, potentially reducing the environmental footprint of traditional hydrogen production methods. This work generates a baseline methodology for hydrogen production from plastic pyrolysis with and without a catalyst and the necessary product distribution baseline from key single plastics. The effect of pyrolysis temperature on the conversion of HDPE was evaluated both with and without a catalyst(s), and the product distributions measured via GC/MS were identified and hydrogen formation was quantified. These results will help guide future research efforts to optimize catalysts and processes for more efficient hydrogen production and mixed plastic waste management.

Catalysts↗