Calorimetry can detect the early onset of hydrolysis in hybrid supercapacitors with aqueous electrolytes

This study investigates the effect of cation species on the onset of electrolyte hydrolysis in hybrid supercapacitors with aqueous electrolytes using isothermal operando calorimetry. The cells consisted of a positive α-MnO 2 cryptomelane electrode and a negative activated carbon (AC) electrode with either 0.5 M K 2 SO 4 or 0.5 M Cs 2 SO 4 aqueous electrolytes. They were characterized using cyclic voltammetry and galvanostatic cycling. In addition, the instantaneous heat generation rate at each electrode was measured using a custom isothermal operando calorimeter. Heat generation associated with resistive losses (Joule heating) and reversible ion adsorption/desorption was clearly identified. For larger potential windows, an endothermic dip, attributed to the onset of hydrolysis, was observed at the positive α-MnO 2 electrode where K + and Cs + ions engaged in fast surface redox reactions. Interestingly, this endothermic dip appeared at 1.8 V and 2.0 V for K 2 SO 4 and Cs 2 SO 4 aqueous electrolytes, respectively. The difference in the stable operating potential window was attributed to thinner solvation shell around Cs + cation than for K + thus reducing the amount of water present near the electrodes as ions partially shed their solvation shells during adsorption. The early onset of hydrolysis could be observed by isothermal operando calorimetry before it could be observed with conventional electrochemical methods.

42 ENGINEERING↗

The battery failure databank: Insights from an open-access database of thermal runaway behaviors of Li-ion cells and a resource for benchmarking risks

The thermal response of Li-ion cells can greatly vary for identical cell designs tested under identical conditions, the distribution of which is costly to fully characterize experimentally. The open-source Battery Failure Databank presented here contains robust, high-quality data from hundreds of abuse tests spanning numerous commercial cell designs and testing conditions. Data was gathered using a fractional thermal runaway calorimeter and contains the fractional breakdown of heat and mass that was ejected, as well as high-speed synchrotron radiography of the internal dynamic response of cells during thermal runaway. The distribution of thermal output, mass ejection, and internal response of commercial cells are compared for different abuse-test conditions, which when normalized on a per amp-hour basis show a strong positive correlation between heat output from cells, the fraction of mass ejected from the cells, their energy- and power-density. Ejected mass was shown to contain 10x more heat per gram than non-ejected mass. The causes of 'outlier' thermal and ejection responses i.e., extreme cases, are elucidated by high-speed radiography which showed how occurrences such as vent clogging can create more hazardous conditions. High-speed radiography also demonstrated how the time-resolved interplay of thermal runaway propagation and mass ejection influences the total heat generated.

25 ENERGY STORAGE↗

Thermal runaway mechanism of lithium-ion battery with LiNi 0.8 Mn 0.1 Co 0.1 O 2 cathode materials

Battery safety is critical to the application of lithium-ion batteries, especially for high energy density battery applied in electric vehicles. In this paper, the thermal runaway mechanism of LiNi 0.8 Co 0.1 Mn 0.1 O 2 based lithium-ion battery is illustrated. And the reaction between cathode and flammable electrolyte is proved as the trigger of the thermal runaway accident. In detail, with differential scanning calorimeter tests for battery components, the material combination contributing to thermal runaway was decoupled. Characterization with synchrotron X-ray diffraction and transmission electron microscopy with in-situ heating proved that the vigorous exothermic reaction is initiated by the liberated oxygen species. The pulse of highly active oxygen species reacted quickly with the electrolyte, accompanied with tremendous heat release, which accelerated the phase transformation of charged cathode. Also, the mechanism is verified by a confirmatory experiment when the highly active oxygen species were trapped by anion receptor, the phase transformation of the charged cathode was inhibited. Clarifying the thermal runaway mechanism of LiNi 0.8 Co 0.1 Mn 0.1 based lithium-ion battery may light the way to battery chemistries of both high energy density and high safety.

25 ENERGY STORAGE↗

The GlueX beamline and detector

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μs$. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. Here, we describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the data acquisition, trigger, and slow control systems of the Mu2e experiment at Fermilab

The Mu2e experiment at the Fermilab will search for a coherent neutrinoless conversion of a muon into an electron in the field of an aluminum nucleus with a sensitivity improvement by a factor of 10,000 over existing limits. In this work, the Mu2e Trigger and Data Acquisition System (TDAQ) uses otsdaq framework as the online Data Acquisition System (DAQ) solution. Developed at Fermilab, otsdaq integrates several framework components — an artdaq-based DAQ, an art-based event processing, and an EPICS-based detector control system (DCS), and provides a uniform multi-user interface to its components through a web browser. Data streams from the Mu2e tracker and calorimeter are handled by the artdaq-based DAQ and processed by a one-level software trigger implemented within the art framework. Events accepted by the trigger have their data combined, post-trigger, with the separately read out data from the Mu2e Cosmic Ray Veto system. Foundation of the Mu2e DCS, EPICS – an Experimental Physics and Industrial Control System – is an open-source platform for monitoring, controlling, alarming, and archiving. A prototype of the TDAQ and the DCS systems has been built and tested over the last three years at Fermilab’s Feynman Computing Center, and now the production system installation is underway. This work presents their status and focus on the installation plans and procedures for racks, workstations, network switches, gateway computers, DAQ hardware, slow controls implementation, and testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal

Here we are reporting on a new readout circuit developed for the lead tungstate (PbWO4) scintillation detectors for the Electron Ion Collider (EIC) Electron Endcap Electromagnetic Calorimeter EEEMCal. The high magnetic field region precludes the use of photomultiplier tubes while the detector requirements specify good spectral resolution performance and fast pulse integration over a large dynamic range. We selected a silicon photomultiplier (SiPM) from Hamamatsu and produced a matrix of 4 x 4 sensors to cover the 20 mm x 20 mm scintillator coupling surface. Signal acquisition and amplification electronics boards were designed and integrated with the sensor board to produce a compact high performance readout package. A prototype detector was built and tested at Jefferson Lab with encouraging resolution and timing performance results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20ps respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Mu2e experiment

The Mu2e experiment at Fermilab searches for the coherent, neutrino-less conversion of a μ − to e − in the Coulomb field of Al nuclei, that represents one of the cleanest Charged Lepton Flavor Violating (CLFV) processes for exploring Beyond the Standard Model (BSM) physics. Mu2e aims to improve previous sensitivity by four orders of magnitude, with a distinctive signature provided by identifying mono-energetic electrons with energy slightly below the muon rest mass. To reach this goal, the experiment will use the highest intensity pulsed muon beam in the world, with up to 6 × 1 0 9 stopped muons/sec. This is achieved using the Fermilab proton beam and the design and realization of a unique 25 m long superconducting solenoidal system. The high beam intensity relies upon minimizing beam losses in the slow extraction region, indicating an opportunity of using bent crystals for shadowing. A high-resolution straw tracker and a fast CsI crystal calorimeter identify the conversion electron. Both detectors are inserted behind the Stopping Target in the last solenoid section. A Cosmic Ray Veto covers a large part of the solenoids to suppress background produced by cosmic rays. In this paper, we report the details of the experimental layout, the construction status of the magnetic system and detectors, and a short description of the simulation and realization of the bent crystals. Performing crystal channeling in front of the first slow extraction septa will allow beam shadowing and largely reduce beam losses. •Charge Lepton Flavor Violation processes: μ − → e − conversion.•Large Superconducting Solenoid system.•High-Intensity beams•High precision detectors.•Crystal channeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of surface-state induced inter-electrode isolation of n -on- p devices in mixed-field and γ -irradiation environments

Position sensitive n-on-p silicon sensors will be utilized in the tracker and in the High Granularity Calorimeter (HGCAL) of the Compact Muon Solenoid (CMS) experiment at High Luminosity Large Hadron Collider (HL-LHC). The detrimental effect of the radiation-induced accumulation of positive net oxide charge on position resolution in n-on-p sensors has typically been countered by the application of isolation implants like p-stop or p-spray between n + -electrodes. In addition to the positively charged layer inside the oxide and close to the Si/SiO 2 -interface, surface damage introduced by ionizing radiation in SiO 2 -passivated silicon particle detectors includes the accumulation of trapped-oxide-charge and interface traps. A previous study of either n/γ (mixed field)- or γ-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed evidence of substantially higher introduction rates of acceptor- and donor-type deep interface traps (N it,acc/don ) in mixed-field environment. Here, in this work, an inter-pad and -strip resistance (or resistivity (ρ int )) simulation study of n-on-p sensors with and without p-stop isolation implants was conducted for both irradiation types. Higher levels of ρint showed correlation to higher densities of deep N it,acc/don , with the inter-pad isolation performance of the mixed-field irradiated sensors becoming independent of the presence of p-stop implant between the n + - electrodes up to about 100 kGy. The low introduction rates of deep N it,acc/don in γ-irradiated sensors resulted in high sensitivity of ρ int to the presence and peak doping of p-stop above the lowest dose of about 7 kGy in the study. As a consequence of the advantageous influence of radiation-induced accumulation of deep N it on the inter-electrode isolation, position sensitive n-on-p sensors without isolation implants may be considered for future HEP-experiments where the radiation is largely due to hadrons.

Akchurin, N. [Texas Tech Univ., Lubbock, TX (Unite↗

Intrinsic energy and time resolution of the Jefferson Lab Hall C Neutral Particle Spectrometer

The Neutral Particle Spectrometer (NPS) is an advanced calorimeter designed to measure neutral electro- magnetic particles with high precision in energy, time, and position, under conditions of high luminosity and significant background. Integrated into the experimental setup of Hall C at Thomas Jefferson National Accelerator Facility, the NPS plays a critical role in studies of nucleon structure through exclusive and semi- inclusive reaction channels. Here, this paper presents an assessment of the detector’s performance characteristics, specifically its energy and timing resolution, derived from elastic electron–proton scattering data. We report an energy resolution between 1.2% and 1.3% in the 4.5–7.3 GeV range, and an intrinsic timing resolution better than 200 ps for energies above 500 MeV. These results serve as a reference for current and future precision measurements in hadronic physics.

Detector performance↗

Performance of the Pair Spectrometer in Hall D at Jefferson Lab

This article describes the performance of the pair spectrometer installed in experimental Hall D at Jefferson Lab and its successfully operation in multiple experiments with the GlueX detector. The primary purpose of the pair spectrometer is the precise determination of the flux of beam photons incident on the GlueX target, a critical input for physics analyses such as absolute cross-section measurements. The photon energy spectrum is determined by reconstructing electron–positron pairs produced in a thin converter inserted into the photon beam. The spectrometer is integrated into the GlueX trigger system, whose electronics enable continuous real-time monitoring of the photon flux and the recording of e+e- pair candidates for offline analysis. In addition, the pair spectrometer provides a versatile test facility for evaluating calorimeter prototypes using leptons with well-defined energies produced via electromagnetic pair production.

Somov, Alexander [Jefferson Lab]↗

Search for CME in U+U and Au+Au collisions in STAR with different approaches of handling backgrounds

We report the chiral magnetic effect (CME) refers to charge separation along a strong magnetic field between left- and right-handed quarks, caused by interactions with topological gluon fields from QCD vacuum fluctuations. We present two approaches to handle the dominant elliptic flow (v 2 ) background in the three-particle correlator (Δγ 112 ), sensitive to CME. In the first approach, we present the Δγ 112 and Δγ 123 measurements in U+U and Au+Au collisions. While hydrodynamic simulations including resonance decays and local charge conservation predict that Δγ 112 scaled by N part /ν 2 will be similar in U+U and Au+Au collisions, the projected B-field exhibits a distinct difference between the two systems and with varying N part . Therefore, U+U and Au+Au collisions provide configurations with different expectations for both CME signal and background. Moreover, the three-particle observable Δγ 123 scaled by N part /ν 3 provide baseline measurement for only the background. In the second approach, we handle the ν 2 background by measuring Δγ 112 with respect to the planes of spectators measured by Zero Degree Calorimeters and participants measured by Time Projection Chamber. These measurements contain different amounts of contributions from CME signal (along B-field, due to spectators) and ν 2 background (determined by the participant geometry). With the two Δγ 112 measurements, the possible CME signal and the background contribution can be determined. We report such a measurement in Au+Au collisions at $\sqrt{s_{NN}}$ = 27GeV with the newly installed event plane detector, and report the new findings in U+U system where the spectator-participant plane correlations are expected to differ from those in Au+Au collisions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New determination of the branching ratio of the structure dependent radiative K + → e + ν e γ

The branching ratio of the structure dependent (SD) radiative K + → e + ν e γ decay relative to that of the K + → e + ν e (γ) decay including the internal bremsstrahlung (IB) process (K e2 (γ) ) has been measured in the J-PARC E36 experiment using plastic scintillator/lead sandwich detectors, in contrast to the previous E36 measurement, which used a CsI(Tl) calorimeter. In the analysis, the effect of IB was also taken into account in the SD radiative decay as $K$$^{SD}_{e2γ(γ)}$. By combining the new data with the previous E36 result after revision for the IB correction for $K$$^{SD}_{e2γ(γ)}$, a new value Br($K$$^{SD}_{e2γ(γ)}$)/Br(Ke 2(γ) ) = 1.20 ± 0.07 has e2γ(γ) e2γ(γ) been determined. This is consistent with a recent lattice QCD calculation, but larger than the expectation of Chiral Perturbation Theory (ChPT) at order O(p 4 ) and the previous KLOE value. Using the method to relate form factor and branching ratio described in the KLOE paper, the present result is also consistent with the form factor prediction based on a gauged nonlocal chiral quark model, but larger than that from ChPT at order O(p 6 ).

79 ASTRONOMY AND ASTROPHYSICS↗

Search for the decay of the Higgs boson to a $Z$ boson and a light pseudoscalar particle decaying to two photons

A search for the decay of the Higgs boson to a Z boson and a light, pseudoscalar particle, a, decaying respectively to two leptons and to two photons is reported. The search uses the full LHC Run 2 proton–proton collision data at $\sqrt{s}$ = 13 TeV, corresponding to 139 fb –1 collected by the ATLAS detector. This is one of the first searches for this specific decay mode of the Higgs boson, and it probes unexplored parameter space in models with axion-like particles (ALPs) and extended scalar sectors. The mass of the $a$ particle is assumed to be in the range 0.1–33 GeV. The data are analysed in two categories: a merged category where the photons from the $a$ decay are reconstructed in the ATLAS calorimeter as a single cluster, and a resolved category in which two separate photons are detected. The main background processes are from Standard Model Z boson production in association with photons or jets. The data are in agreement with the background predictions, and upper limits on the branching ratio of the Higgs boson decay to $Za$ times the branching ratio $a → γγ$ are derived at the 95% confidence level and they range from 0.08% to 2% depending on the mass of the $a$ particle. The results are also interpreted in the context of ALP models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing gluon saturation with forward di-hadron correlations in proton-nucleus collisions

We present a detailed numerical investigation of semi-inclusive forward di-hadron production in proton–nucleus collisions employing the Color Glass Condensate effective theory. We focus on the regime where di-hadrons are produced nearly back-to-back in the transverse plane, thereby justifying a transverse-momentum-dependent factorization approach in terms of small-x gluon distributions. Our computation integrates several key elements: i) non-linear rapidity evolution via the Balitsky–Kovchegov equation with running coupling, ii) both perturbative and non-perturbative Sudakov resummation, and iii) a phenomenologically constrained model for the initial conditions for small-x gluon distributions. We compare this phenomenological framework to experimental data from the STAR Collaboration on azimuthal correlations in forward di-pion production in both proton–proton and proton–gold collisions. We analyze the systematic theoretical uncertainties associated with the saturation scales of nuclei at the initial scale for rapidity evolution and with those associated with the hadronization process. Finally, we make predictions for the kinematics anticipated to be covered by the ALICE Forward Calorimeter (FoCal) upgrade at the Large Hadron Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiments on the Capillary Condensation/Evaporation Hysteresis of Pure Fluids and Binary Mixtures in Cylindrical Nanopores

Here, a new experimental method, i.e., isochoric cooling/heating cycle measurement using differential scanning calorimeter (DSC), is applied to investigate the hysteretic phenomenon of pure components and mixtures confined in two different types of cylindrical nanopores (SBA-15 and KIT-6). The capillary condensation/evaporation hysteresis end point (T he ) for a specific system is determined by performing a series of measurements with different densities by increasing initial temperature and pressure. We confirm that for a pure component, T he is lower when confined in smaller nanopores, whereas T he for CH 4 /CO 2 and CH 4 /C 2 H 6 mixtures at the specific composition investigated are higher than that of pure CO 2 and C 2 H 6 , respectively, when confined in the same nanopores. To the best of our knowledge, this is the first time that T he of fluid mixture is experimentally studied, which further demonstrates that binary mixtures behave similarly to pure fluids when confined in nanoporous media. At low temperatures where hysteresis is observed, the shape as well as the duration of the exothermic peak (due to capillary condensation) and endothermic peak (due to capillary evaporation) indicate that capillary condensation, rather than capillary evaporation, takes place at/near a thermodynamic equilibrium. Within the accuracy of the measurements, we find that the total heat of capillary condensation is identical to that of capillary evaporation for all systems examined, regardless of the presence of hysteresis. By comparing the heat per unit volume among different systems, we also find that the heat per unit volume of the phase transition of confined pure fluid is lower than that of bulk, which further demonstrates that the molar density of confined pure liquid is less than that of bulk pure liquid at saturation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Volatile Products of the Autoxidation of Poly(ethylenimine) in CO 2 Sorbents

Poly(ethyleneimine) (PEI)-based CO 2 sorbents are a promising material class for use in CO 2 capture applications, particularly direct air capture (DAC), due to their high amine content and CO 2 capacities. The sorbent lifetime is a key uncertainty in the deployment of these materials in such applications, as they oxidize under conditions relevant to candidate DAC process cycles. Here, in this study, we utilize thermogravimetric analysis/differential scanning calorimetry/FTIR spectroscopy to characterize the nature, rate, and quantity of volatile species formed from the oxidation of PEI when supported on mesoporous Al 2 O 3 . We show that NH 3 , CO 2 , and H 2 O are primary volatile species formed from PEI oxidation and that their production rate matches the overall oxidation rate as measured via heat flow from a differential scanning calorimeter. We show that the total quantity of NH 3 evolved is consistent with terminal primary amines being cleaved from the polymer chain and that approximately one hydrogen atom per PEI repeat unit reacts to form H 2 O during the reaction. Finally, metadynamics and quantum chemical simulations performed on a simplified system are used to highlight the likely importance of radicals in the elementary reactions that comprise the oxidation reaction set. The findings here represent the first characterization of the volatile products from the oxidation of PEI in CO 2 sorbents and lead to a greater understanding of the mechanisms behind the oxidative degradation of these materials.

36 MATERIALS SCIENCE↗

Phase Transition and Criticality of Methane Confined in Nanopores

For the first time, the phase transition and criticality of methane confined in nanoporous media are measured. The measurement is performed by establishing an experimental setup utilizing a differential scanning calorimeter (DSC) capable of operating under very low temperatures as well as high pressures to detect the capillary phase transition of methane inside nanopores. By performing experiments along isochoric cooling paths, both the capillary condensation and the bulk condensation of methane are detected. Here, the pore critical point (PCP) of nanoconfined methane is also determined and then used to derive the parameters of a previously developed self-consistent equation of state based on the Generalized van der Waals (vdW) partition function. Using this parameter, the equation of state can predict the capillary-condensation curves that agree well with the experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗