Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ablation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Specific features of single-pulse femtosecond laser micron and submicron ablation of a thin silver film coated with a micron-thick photoresist layer

Specific features of ablation of a thin silver film with a 1-μm-thick layer of a highly transparent photoresist and the same film without a photoresist layer under single tightly focused femtosecond laser pulses in the visible range (515 nm) are experimentally investigated. Interference effects of internal modification of the photoresist layer, its spallation ablation from the film surface and formation of through hollow submicron channels in the resist without its spallation but with ablation of the silver film lying under the resist are found and discussed. (extreme light fields and their applications)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectral features of colloidal solutions of elongated gold nanoparticles produced by laser ablation in aqueous solutions

The extinction spectra of colloidal solutions of gold nanoparticles produced by laser ablation in water and aqueous solutions of salts using two near-IR lasers with pulse durations of 200 ns and 1 ps are experimentally investigated. The extinction spectrum of the particles formed by ablation in aqueous solutions is characterised by enhanced optical density in the red and IR regions. This feature is due to the formation of elongated gold nanoparticles, as confirmed by transmission electron microscopy. The surface images of a gold target subjected to multipulse laser ablation exhibit micron and submicron structures. (nanophotonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EJECTA KNOT FLICKERING, MASS ABLATION, AND FRAGMENTATION IN CASSIOPEIA A

Ejecta knot flickering, ablation tails, and fragmentation are expected signatures associated with the gradual dissolution of high-velocity supernova (SN) ejecta caused by their passage through an inhomogeneous circumstellar medium or interstellar medium (ISM). Such phenomena mark the initial stages of the gradual merger of SN ejecta with and the enrichment of the surrounding ISM. Here we report on an investigation of this process through changes in the optical flux and morphology of several high-velocity ejecta knots located in the outskirts of the young core-collapse SN remnant Cassiopeia A using Hubble Space Telescope images. Examination of WFPC2 F675W and combined ACS F625W + F775W images taken between 1999 June and 2004 December of several dozen debris fragments in the remnant's northeast ejecta stream and along the remnant's eastern limb reveal substantial emission variations ('flickering') over timescales as short as nine months. Such widespread and rapid variability indicates knot scale lengths {approx_equal} 10{sup 15} cm and a highly inhomogeneous surrounding medium. We also identify a small percentage of ejecta knots located all around the remnant's outer periphery which show trailing emissions typically 0.''2-0.''7 in length aligned along the knot's direction of motion suggestive of knot ablation tails. We discuss the nature of these trailing emissions as they pertain to ablation cooling, knot disruption, and fragmentation, and draw comparisons to the emission 'strings' seen in {eta} Car. Finally, we identify several tight clusters of small ejecta knots which resemble models of shock-induced fragmentation of larger SN ejecta knots caused by a high-velocity interaction with a lower density ambient medium.

79 ASTRONOMY AND ASTROPHYSICS↗

In situ studies of a molten metal anode ablation in a nearly atmospheric pressure DC arc

A DC arc with a meltable metal anode in a near-atmospheric pressure hydrocarbon gas is an emerging method for producing single-walled carbon nanotubes (SWCNTs). In these systems, evaporation of the molten metal anode determines the formation of catalyst seed particles needed for SWCNT growth, and therefore, should be monitored, controlled, and optimized. Evaluating the anode ablation rate by weighing the anode before and after a synthesis run is unfeasible due to anode carburization in the hydrocarbon atmosphere. To overcome this, we implemented a high-speed, 2D, 2-color pyrometry for reliable temperature measurements of the molten anode in a DC arc. The obtained temperature fields were used to calculate the anode ablation rates. Results showed the importance of resolving the arc and molten pool dynamics, as well as addressing the issue of reflections. Furthermore, significant changes in ablation rates were revealed upon addition of CH 4 , which must be considered when scaling up the production of SWCNTs.

Marangoni↗

Damage in materials following ablation by ultrashort laser pulses: A molecular-dynamics study

The formation of craters following femtosecond- and picosecond-pulse laser ablation in the thermal regime is studied using a generic two-dimensional numerical model based on molecular-dynamics simulations and the Lennard-Jones potential. Femtosecond pulses are found to produce very clean craters through a combination of etching of the walls and the formation of a very thin heat affected zone. Our simulations also indicate that dislocations are emitted continuously during all of the ablation process (i.e., for hundreds of ps). For picosecond pulses, we observe much thicker heat affected zones which result from melting and recrystallization following the absorption of the light. In this case also, continuous emission of dislocations--though fewer in number--takes place throughout the ablation process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modifying Wire-Array Z-Pinch Ablation Structure Using Coiled Arrays

A new wire-array configuration has been used to control the modulation of ablated plasma flow for the first time. Cylindrical aluminum coiled arrays, in which each straight wire is replaced with a single helix, were driven by a 1 MA, 240 ns current pulse. Ablated plasma is directed away from the coiled wire cores in a manner that can be understood in terms of Lorentz forces that arise from a complex current path modeled by 3D magnetohydrodynamic simulations. Outside the diameter of the helix, the flow of ablated plasma is axially modulated at the wavelength of the coil.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser-Ablation Rates Measured Using X-Ray Laser Transmission

The rate of laser ablation at irradiances of {approx}2x10{sup 14} W cm{sup -2} of solid iron has been measured using the transmission of a neonlike zinc x-ray laser at 21.2 nm through thin iron targets. Ablated iron becomes transparent to the x-ray laser flux, enabling the thickness of unablated material and hence the rate of ablation to be measured from time resolved x-ray laser transmission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

External Magnetic Field Effects on Ablation of Current-Driven Foils Using an Extended Magnetohydrodynamics Simulation

We numerically model the ablation process of a 25-μm-thick aluminum foil driven by a pulsed-power machine that provides a 1-MA peak current in a 100-ns zero-to-peak rise time. The extended magnetohydrodynamics simulation is a discontinuous Galerkin code with Cartesian coordinates in 3-D and with 25-μm spatial resolution. We investigate here the influence of an external magnetic field normal to the foil surface, B z . During the foil ablation, B z = 1 T causes more nonuniform distributions of density and current compared to B z = 0 T. B z = 4 T delays the generation of surface plasma relative to the 0- and 1-T cases. The understanding of a material's ablation as it undergoes transition from the solid to plasma phases requires detailed knowledge of a material's equation of state and conductivity. This paper of warm dense matter and how instabilities propagate from a solid material to plasma motivates improvements to both numerical simulations and experimental diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Model-based feasibility assessment and evaluation of prostate hyperthermia with a commercial MR-guided endorectal HIFU ablation array

Purpose: Feasibility of targeted and volumetric hyperthermia (40–45 °C) delivery to the prostate with a commercial MR-guided endorectal ultrasound phased array system, designed specifically for thermal ablation and approved for ablation trials (ExAblate 2100, Insightec Ltd.), was assessed through computer simulations and tissue-equivalent phantom experiments with the intention of fast clinical translation for targeted hyperthermia in conjunction with radiotherapy and chemotherapy. Methods: The simulations included a 3D finite element method based biothermal model, and acoustic field calculations for the ExAblate ERUS phased array (2.3 MHz, 2.3 × 4.0 cm{sup 2}, ∼1000 channels) using the rectangular radiator method. Array beamforming strategies were investigated to deliver protracted, continuous-wave hyperthermia to focal prostate cancer targets identified from representative patient cases. Constraints on power densities, sonication durations and switching speeds imposed by ExAblate hardware and software were incorporated in the models. Preliminary experiments included beamformed sonications in tissue mimicking phantoms under MR temperature monitoring at 3 T (GE Discovery MR750W). Results: Acoustic intensities considered during simulation were limited to ensure mild hyperthermia (T{sub max} < 45 °C) and fail-safe operation of the ExAblate array (spatial and time averaged acoustic intensity I{sub SATA} < 3.4 W/cm{sup 2}). Tissue volumes with therapeutic temperature levels (T > 41 °C) were estimated. Numerical simulations indicated that T > 41 °C was calculated in 13–23 cm{sup 3} volumes for sonications with planar or diverging beam patterns at 0.9–1.2 W/cm{sup 2}, in 4.5–5.8 cm{sup 3} volumes for simultaneous multipoint focus beam patterns at ∼0.7 W/cm{sup 2}, and in ∼6.0 cm{sup 3} for curvilinear (cylindrical) beam patterns at 0.75 W/cm{sup 2}. Focused heating patterns may be practical for treating focal disease in a single posterior quadrant of the prostate and diffused heating patterns may be useful for heating quadrants, hemigland volumes or even bilateral targets. Treatable volumes may be limited by pubic bone heating. Therapeutic temperatures were estimated for a range of physiological parameters, sonication duty cycles and rectal cooling. Hyperthermia specific phasing patterns were implemented on the ExAblate prostate array and continuous-wave sonications (∼0.88 W/cm{sup 2}, 15 min) were performed in tissue-mimicking material with real-time MR-based temperature imaging (PRFS imaging at 3.0 T). Shapes of heating patterns observed during experiments were consistent with simulations. Conclusions: The ExAblate 2100, designed specifically for thermal ablation, can be controlled for delivering continuous hyperthermia in prostate while working within operational constraints.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atomistic simulation of laser ablation of gold: Effect of pressure relaxation

The process of ablation of a gold target by femto- and picosecond laser radiation pulses has been studied by numerical simulations using an atomistic model with allowance for the electron subsystem and the dependence of the ion-ion interaction potential on the electron temperature. Using this potential, it is possible to take into account the change in the physical properties of the ion subsystem as a result of heating of the electron subsystem. The results of simulations reveal a significant difference between the characteristics of metal ablation by laser pulses of various durations. For ablation with subpicosecond pulses, two mechanisms of metal fracture related to the evolution of electronic pressure in the system are established.

74 ATOMIC AND MOLECULAR PHYSICS↗

Surface Modification of ICF Target Capsules by Pulsed Laser Ablation

Topographical modifications of spherical surfaces are imprinted on National Ignition Facility (NIF) target capsules by extending the capabilities of a recently developed full surface (4π) laser ablation and mapping apparatus. The laser ablation method combines the precision, energy density and long reach of a focused laser beam to pre-impose sinusoidal modulations on the outside surface of High Density Carbon (HDC) capsules and the inside surface of Glow Discharge Polymer (GDP) capsules. Sinusoidal modulations described in this paper have sub-micron to 10’s of microns vertical scale and wavelengths as small as 30 μm and as large as 200 μm. The modulated patterns are created by rastering a focused laser fired at discrete capsule surface locations for a specified number of pulses. The computer program developed to create these raster patterns uses inputs such as laser beam intensity profile, the material removal function, the starting surface figure and the desired surface figure. The patterns are optimized to minimize surface roughness. Lastly, in this paper, simulated surfaces are compared with actual ablated surfaces measured using confocal microscopy.

36 MATERIALS SCIENCE↗

Extension of cutoff in high harmonic by using doubly charged ions in a laser-ablation plume

We report high-order harmonic generation from doubly charged ions in laser-ablation plasma produced by different prepulse intensities. At the prepulse intensity of 3.5x10{sup 10} W cm{sup -2}, harmonics up to the 63rd order (12.62 nm wavelength, 98.3 eV photon energy) were obtained by using a laser-ablation titanium plume. From analysis of the harmonics and visible radiation from the laser-ablation titanium plume at different prepulse intensities, we conclude that the highest harmonics near the cutoff region originated from doubly charged titanium ions. These studies show the effectiveness of using doubly charged ions to extend the cutoff energy of high-order harmonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deep Dive Topic: Choosing between ablators

Recent data on implosions using identical hohlraums and very similar laser drives underscores the conundrum of making a clear choice of one ablator over another. Table I shows a comparison of Be and CH in a nominal length, gold, 575 μm-diameter, 1.6 mg/cc He gas-fill hohlraum while Table II shows a comparison of undoped HDC and CH in a +700 length, gold, 575 μm diameter, 1.6 mg/cc He gas fill hohlraum. As can be seen in the tables, the net integrated fusion performance of these ablators is the same to within error bars. In the case of the undoped HDC and CH ablators, the hot spot shapes of the implosions were nearly indistinguishable for the experiments listed in Table II.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Selective Laser Ablation in Resists and Block Copolymers for High Resolution Lithographic Patterning

Previously, we demonstrated an all dry, selective laser ablation development in methyl acetoxy calixarene (MAC6) which produced high resolution (15-25 nm half-pitch), high aspect ratio features not achievable with wet development. In this paper, we investigate the selective laser ablation process as a means to create a block copolymer derived lithographic pattern through the selective removal of one block. Two block copolymer systems were investigated PS-b-PHOST, and P2VP-b-PS-b-P2VP. The selective laser ablations process on block copolymers offers an alternative to plasma etching when plasma etching is not effective.

36 MATERIALS SCIENCE↗

Experimental Simulation of Meteorite Ablation during Earth Entry Using a Plasma Wind Tunnel

Three different types of rocks were tested in a high enthalpy air plasma flow. Two terrestrial rocks, basalt and argillite, and an ordinary chondrite, with a 10 mm diameter cylindrical shape were tested in order to observe decomposition, potential fragmentation, and spectral signature. The goal was to simulate meteoroid ablation to interpret meteor observation and compare these observations with ground based measurements. The test flow with a local mass-specific enthalpy of 70 MJ kg{sup −1} results in a surface heat flux at the meteorite fragment surface of approximately 16 MW m{sup −2}. The stagnation pressure is 24 hPa, which corresponds to a flight condition in the upper atmosphere around 80 km assuming an entry velocity of 10 km s{sup −1}. Five different diagnostic methods were applied simultaneously to characterize the meteorite fragmentation and destruction in the ground test: short exposure photography, regular video, high-speed imaging with 10 kHz frame rate, thermography, and Echelle emission spectroscopy. This is the first time that comprehensive testing of various meteorite fragments under the same flow condition was conducted. The data sets indeed show typical meteorite ablation behavior. The cylindrically shaped fragments melt and evaporate within about 4 s. The spectral data allow the identification of the material from the spectra which is of particular importance for future spectroscopic meteor observations. For the tested ordinary chondrite sample a comparison to an observed meteor spectra shows good agreement. The present data show that this testing methodology reproduces the ablation phenomena of meteoritic material alongside the corresponding spectral signatures.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of Conformable Phenolic Impregnated Carbon Ablator in Aerothermal Environments

Conformable Phenolic Impregnated Carbon Ablator, a cousin of Phenolic Impregnated Carbon Ablator (PICA), was developed at NASA Ames Research Center as a lightweight thermal protection system under the Fundamental Aeronautics Program. PICA is made using a brittle carbon substrate, which has a very low strain to failure. Conformable PICA is made using a flexible carbon substrate, a felt in this case. The flexible felt significantly increases the strain to failure of the ablator. PICA is limited by its thermal mechanical properties. Future NASA missions will require heatshields that are more fracture resistant than PICA and, as a result, NASA Ames is working to improve PICA's performance by developing conformable PICA to meet these needs. Research efforts include tailoring the chemistry of conformable PICA with varying amounts of additives to enhance mechanical properties and testing them in aerothermal environments. This poster shows the performance of conformable PICA variants in arc jets tests. Some mechanical and thermal properties will also be presented.

ablative materials↗

Thermal Ablation Modeling for Silicate Materials

A thermal ablation model for silicates is proposed. The model includes the mass losses through the balance between evaporation and condensation, and through the moving molten layer driven by surface shear force and pressure gradient. This model can be applied in ablation simulations of the meteoroid or glassy Thermal Protection Systems for spacecraft. Time-dependent axi-symmetric computations are performed by coupling the fluid dynamics code, Data-Parallel Line Relaxation program, with the material response code, Two-dimensional Implicit Thermal Ablation simulation program, to predict the mass lost rates and shape change. For model validation, the surface recession of fused amorphous quartz rod is computed, and the recession predictions reasonably agree with available data. The present parametric studies for two groups of meteoroid earth entry conditions indicate that the mass loss through moving molten layer is negligibly small for heat-flux conditions at around 1 MW/cm(exp. 2).

Ablators↗

Cyanate Ester and Phthalonitrile Impregnated Carbon Ablative TPS

Phenolic resin has extensive heritage as a TPS (Thermal Protection Systems) material, however, alternative resin systems such as Cyanate Ester and Phthalonitrile may offer improved performance compared to state-of-the-art phenolic resin. These alternative resin systems may have higher char yield, higher char strength, lower thermal conductivity and improved mechanical properties. In current work at NASA Ames alternative resin systems were uniformly infused into fibrous substrates and preliminary properties characterized. The density of the cyanate ester infused in fibrous substrate ranged from 0.25-0.3 grams per cubic centimeter compared to PICA (Phenolic resin impregnated carbon ablative) having a density of approximately 0.25 grams per cubic centimeter. The density of Phthalonitrile varies from 0.22-0.25 grams per cubic centimeter. Initial formulations of these new resin systems were recently tested at the LARC HyMETs (Hypersonic Materials Environmental Test System) facility to evaluate their performance and data such as back face temperature, char yield, and recession are compared to PICA. Cyanate Ester and Phthalonitrile impregnated carbon ablative samples showed comparable performance to phenolic resin impregnated carbon ablative samples.

Polymer↗