Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

High resolution imaging X-ray detector for astronomical measurements

The article describes the X-ray detector which will provide second-of-arc images for the HEAO-B X-ray observatory. The instrument uses microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. Position determination is accomplished by electronic interpolation between the coarse grid wires. The detector provides the arrival time and position of each event which occurs within its field of view. Measurements of the spatial resolution (15 microns), temporal resolution (7.8 microsec), image distortion (less than 10 microns), uniformity of efficiency (less than plus or minus 10%), dark counting rate (0.2 cts/sq cm/s), and quantum efficiency (10% at 1.54 keV) of this detector are described. A summary of the procedure which was found useful during the initial turn-on of microchannel plates is given.

Henry, J. P.↗

Pulsed-Neutron Die-Away Response of H 2 O Targets to a D-T Generator Pulse

Pulsed-neutron die-away (PNDA) experiments were completed at Lawrence Livermore National Laboratory (LLNL). The goal of these experiments was to provide a benchmark to validate thermal neutron scattering laws of H 2 O. The experiment was conducted with a deuterium-tritium (D-T) neutron generator producing pulses of 14.1 MeV neutrons that impinged on a moderating target. The neutrons scattered and thermalized within the target and were counted as a function of time using Helium-3 ( 3 He) detectors that surrounded the target. These data provide a time-decay profile of the neutron population from which the time eigenvalue of the experiment is calculated. The time eigenvalue quantity α represents the integral parameter of interest. This report describes the measurements for H 2 O targets. The measurements were conducted over several days beginning on October 23rd, 2023. All measurements were completed at the low-scatter facility at LLNL. The evaluation identifier is FUND-LLNL-DT-H2O-PNDA-001.

3He Detectors↗

Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science Addendum

Activation detectors developed at LLNL for measuring real-time neutron fluence from fusion sources are used in the broader fusion community. The recommended fluence operating range of this diagnostic is 5x10 2 – 1x10 6 n/cm2. The upper limit on this fluence range is set by the dead time caused by data transfer between the detector and data acquisition computer. Delaying the start of counting is a possible strategy to operate these detectors in higher fluences.

42 ENGINEERING↗

Calibration and simulation of ionization signal and electronics noise in the ICARUS liquid argon time projection chamber

The ICARUS liquid argon time projection chamber (LArTPC) neutrino detector has been taking physics data since 2022 as part of the Short-Baseline Neutrino (SBN) Program. This paper details the equalization of the response to charge in the ICARUS time projection chamber (TPC), as well as data-driven tuning of the simulation of ionization charge signals and electronics noise. The equalization procedure removes non-uniformities in the ICARUS TPC response to charge in space and time. This work leverages the copious number of cosmic ray muons available to ICARUS at the surface. The ionization signal shape simulation applies a novel procedure that tunes the simulation to match what is measured in data. The end result of the equalization procedure and simulation tuning allows for a comparison of charge measurements in ICARUS between Monte Carlo simulation and data, showing good performance with minimal residual bias between the two.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new array for the study of ultra high energy gamma-ray sources

The design and operation of a 32 x 1 10 to the 15th power sq m array of scintillation detectors for the detection of 10 to the 15th power eV cosmic rays is described with an expected angular resolution of 1 deg, thus improving the present signal/background ratio for gamma ray sources. Data are recorded on a hybrid CAMAC, an in-house system which uses a laser and Pockel-Cell arrangement to routinely calibrate the timing stability of the detectors.

Brooke, G.↗

Coherent 1-micron lidar measurements of atmospheric-turbulence-induced spatial decorrelation using a multielement heterodyne detector array

A coherent 1-micron Nd:YAG lidar system is employed to measure directly the reduced spatial coherence length rho 0 of the lidar returns caused by atmospheric turbulence. The experiments were conducted by using a 2 x 2 heterodyne detector array, which permitted real-time spatial correlation measurements of the lidar returns at two different detector spacings. The spatial correlation coefficients and spatial coherence length of the lidar returns from a hard target were measured during a day-to-night time period when the atmospheric turbulence parameter, Cn-squared, was measured to vary from 2 x 10 exp -13 to 2 x 10 exp -4 m exp -2/3. These directly measured values of rho 0 as a function of Cn-squared were found to be in good agreement with theoretical predictions.

Chan, Kin P.↗

Development of ultra-pure gadolinium sulfate for the Super-Kamiokande gadolinium project

This paper reports the development and detailed properties of about 13 metric tons of gadolinium sulfate octahydrate, Gd 2 (SO 4 ) 3 • 8H 2 O⁠, which has been dissolved into Super-Kamiokande (SK) in the summer of 2020. We evaluate the impact of radioactive impurities in Gd 2 (SO 4 ) 3 • 8H 2 O on diffuse supernova neutrino background searches and solar neutrino observation and confirm the need to reduce radioactive and fluorescent impurities by about three orders of magnitude from commercially available high-purity Gd 2 (SO 4 ) 3 • 8H 2 O⁠. In order to produce ultra-high-purity Gd 2 (SO 4 ) 3 • 8H 2 O, we have developed a method to remove impurities from gadolinium oxide, Gd 2 O 3 , consisting of acid dissolution, solvent extraction, and pH control processes, followed by a high-purity sulfation process. All of the produced ultra-high-purity Gd 2 (SO 4 ) 3 • 8H 2 O is assayed by inductively coupled plasma mass spectrometry and high-purity germanium detectors to evaluate its quality. Because of the long measurement time of high-purity germanium detectors, we have employed several underground laboratories for making parallel measurements including the Laboratorio Subterráneo de Canfranc in Spain, Boulby in the UK, and Kamioka in Japan. In the first half of production, the measured batch purities were found to be consistent with the specifications. However, in the latter half, the Gd 2 (SO 4 ) 3 • 8H 2 O contained one order of magnitude more 228Ra than the budgeted mean contamination. This was correlated with the corresponding characteristics of the raw material Gd 2 O 3 , in which an intrinsically large contamination was present. Based on their modest impact on SK physics, they were nevertheless introduced into the detector. To reduce 228 Ra for the next stage of gadolinium loading to SK, a new process has been successfully established.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary design and performance of an advanced gamma ray spectrometer for future orbiter missions

A knowledge of the composition of planets, satellites, and asteroids is of primary importance in understanding the formation and evolution of the solar system. Gamma-ray spectroscopy is capable of measuring the composition of meter-depth surface material from orbit around any body possessing little or no atmosphere. Measurement sensitivity is determined by detector efficiency and resolution, counting time, and the background flux while the effective spatial resolution depends upon the field-of-view and counting time together with the regional contrast in composition. The advantages of using germanium as a detector of gamma rays in space are illustrated experimentally and a compact instrument cooled by passive thermal radiation is described. Calculations of the expected sensitivity of this instrument at the Moon and Mars show that at least a dozen elements will be detected, twice the number which have been isolated in the Apollo gamma-ray data.

Metzger, A. E.↗

Preliminary design and performance of an advanced gamma-ray spectrometer for future orbiter missions

A knowledge of the composition of planets, satellites, and asteroids is of primary importance in understanding the formation and evolution of the solar system. Gamma-ray spectroscopy is capable of measuring the composition of meter-depth surface material from orbit around any body possessing little or no atmosphere. Measurement sensitivity is determined by detector efficiency and resolution, counting time and the background flux, while the effective spatial resolution depends upon the field-of-view and counting time together with the regional contrast in composition. The advantages of using germanium as a detector of gamma rays in space are illustrated experimentally and a compact instrument cooled by passive thermal radiation is described. Calculations of the expected sensitivity of this instrument at the moon and Mars show that at least a dozen elements should be measurable, twice the number which have been isolated in the Apollo gamma-ray data

Metzger, A. E.↗

Using the EXIST Active Shields for Earth Occultation Observations of X-Ray Sources

The EXIST active shields, now being planned for the main detectors of the coded aperture telescope, will have approximately 15 times the area of the BATSE detectors; and they will have a good geometry on the spacecraft for viewing both the leading and training Earth's limb for occultation observations. These occultation observations will complement the imaging observations of EXIST and can extend them to higher energies. Earth occultatio observations of the hard X-ray sky with BATSE on the Compton Gamma Ray Observatory developed and demonstrated the capabilities of large, flat, uncollimated detectors for this method. With BATSE, a catalog of 179 X-ray sources was monitored twice every spacecraft orbit for 9 years at energies above about 25 keV, resulting in 83 definite detections and 36 possible detections with 5-sigma detection sensitivities of 3.5-20 mcrab (20-430 keV) depending on the sky location. This catalog included four transients discovered with this technique and many variable objects (galactic and extragalactic). This poster will describe the Earth occultation technique, summarize the BATSE occultation observations, and compare the basic observational parameters of the occultation detector elements of BATSE and EXIST.

Wilson, Colleen A.↗

Hardware-accelerated inference for real-time gravitational-wave astronomy

The field of transient astronomy has seen a revolution with the first gravitational-wave detections and the arrival of multi-messenger observations they enabled. Transformed by the first detection of binary black hole and binary neutron star mergers, computational demands in gravitational-wave astronomy are expected to grow by at least a factor of two over the next five years as the global network of kilometer-scale interferometers are brought to design sensitivity. With the increase in detector sensitivity, real-time delivery of gravitational-wave alerts will become increasingly important as an enabler of multi-messenger followup. In this work, we report a novel implementation and deployment of deep learning inference for real-time gravitational-wave data denoising and astrophysical source identification. This is accomplished using a generic Inference-as-a-Service model that is capable of adapting to the future needs of gravitational-wave data analysis. Overall, our implementation allows seamless incorporation of hardware accelerators and also enables the use of commercial or private (dedicated) as-a-service computing. Based on our results, we propose a paradigm shift in low-latency and offline computing in gravitational-wave astronomy. Such a shift can address key challenges in peak-usage, scalability and reliability, and provide a data analysis platform particularly optimized for deep learning applications. The achieved sub-millisecond scale latency will also be relevant for any machine learning-based real-time control systems that may be invoked in the operation of near-future and next generation ground-based laser interferometers, as well as the front-end collection, distribution and processing of data from such instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Restoration and Reexamination of Apollo Lunar Dust Detector Data from Original Telemetry Files

We are recovering the original telemetry (Figure I) from the Apollo Dust, Thermal, Radiation Environment Monitor (DTREM) experiment, more commonly known as the Dust Detector, and producing full time resolution (54 second) data sets for release through the Planetary Data System (PDS). The primary objective of the experiment was to evaluate the effect of dust deposition, temperature, and radiation damage on solar cells on the lunar surface. The monitor was a small box consisting of three solar cells and thermistors mounted on the ALSEP (Apollo Lunar Surface Experiments Package) central station. The Dust Detector was carried on Apollo's 11, 12, 14 and 15. The Apollo 11 DTREM was powered by solar cells and only operated for a few months as planned. The Apollo 12, 14, and 15 detectors operated for 5 to 7 years, returning data every 54 seconds, consisting of voltage outputs from the three solar cells and temperatures measured by the three thermistors. The telemetry was received at ground stations and held on the Apollo Housekeeping (known as "Word 33") tapes. made available to the National Space Science Data Center (NSSDC) by Yosio Nakamura (University of Texas Institute for Geophysics). We have converted selected parts of the telemetry into uncalibrated and calibrated output voltages and temperatures.

McBride, M. J.↗

Simultaneous analysis of collinear neutron time-of-flight (nToF) traces applied to pulsed fusion experiment

On pulsed fusion experiments, the neutron time of flight (nToF) diagnostic provides critical information on the fusion neutron energy spectrum. This work presents an analysis technique that uses two collinear nToF detectors, potentially to measure nuclear bang time and directional flow velocities. Two collinear detectors may be sufficient to disambiguate the contributions of nuclear bang time and directional flow velocities to the first moment of the neutron energy spectrum, providing an independent measurement of nuclear bang time. In conclusion, preliminary results from measured nToF traces on the National Ignition Facility and additional applications of this technique are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of the large-area detectors for the Burst and Transient Source Experiment (BATSE) on the Gamma Ray Observatory

BATSE, one of four experiments on the Gamma Ray Observatory (GRO), is expected to provide the most sensitive observations of gamma-ray bursts yet obtained, as well as to provide long-term monitoring of hard X-ray and low-energy gamma-ray emission from bright pulsating sources, transients, and solar flares. Eight uncollimated modules, positioned at the corners of the spacecraft to provide an unobstructed view of the sky, detect sources by various techniques based on time variability. Use of detectors with anisotropic response allows location of gamma-ray bursts to be determined to an accuracy of about 1 deg using BATSE data alone. The completed BATSE underwent intensive testing and calibration prior to its delivery in October 1988.

Paciesas, W. S.↗

Thin-film lithium niobate electro-optic terahertz wave detector

Here, the design, fabrication, and validation of a thin-film lithium niobate on insulator (LNOI) electro-optic (EO) time-domain terahertz (THz) wave detector is reported. LNOI offers unprecedented properties for the EO detection of freely propagating THz wave radiation pulses and transient electric fields because of the large EO coefficient of the material, engineering of the velocity matching of the THz wave and optical wave, and much reduced detector size. The proof-of-concept device is realized using thin-film lithium niobate optical waveguides forming a Mach–Zehnder interferometer with interferometer arms electrically poled in opposite directions. THz waves are coupled effectively to the fully dielectric device from free space without using antennas or plasmonics. The detection of THz waves with frequencies up to 800 GHz is successfully demonstrated. The detector allows for the detection of THz frequency electric fields up to 4.6 MV/m. The observed frequency response of the device agrees well with theoretical predictions.

47 OTHER INSTRUMENTATION↗

Radiation environment of Spacelab-1

The results of passive and active radiation measurements on Spacelab-1 are reported. Spacelab-1 was flown on the STS-9 mission, orbited at an altitude of 241 km, with an inclination of 57 deg and 240 hours of flight time. Approximately thirty passive detectors deployed inside the module, in the access tunnel, and outside on the pallet made possible the radiation measurements. The various forms of radiation measured were a low linear energy transfer component ranging from 94 to 133 mrads inside the module (average dose rate of 10.0 mrads/day; about twice the rate of earlier shuttle flights), an average mission dose-equivalent rate of about 18.5 mrem/day (six times higher than earlier flights), accumulated doses of 125 and 128 mrads and a yield of 17 and 12 mrads for passages through the South Atlantic Anomaly. Spacelab-1, because of its low altitude and short duration, was relatively benign in terms of total radiation dose. Some of the measurements such as high-LET particles and neutrons have biological significance and potential effects on future experiments.

Benton, E. V.↗

sPHENIX Highlights: First Results from sPHENIX at RHIC

First results from the sPHENIX experiment on the π 0 v 2 and dE T =dη in Au+Au collisions at $\sqrt{s_{NN}}$ = 200 GeV using detector commissioning data during the RHIC 2023 Run are presented. These results are shown across a large centrality range, and compared to previous PHENIX and STAR results. These measurements demonstrate the sPHENIX capabilities towards accomplishing the sPHENIX jet physics program. From the ongoing RHIC 2024 Run, p + p collisions at $\sqrt{s}$ = 200 GeV, a first glimpse of the measurements K S 0 and Λ 0 obtained by the sPHENIX Time Projection Chamber (TPC) detector are shown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Programmable scan/read circuitry for charge coupled device imaging detectors

A circuit for scanning and outputting the induced charges in a solid state charge coupled device (CCD) image detector is disclosed in an image detection system for use in a spacecraft attitude control system. The image detection system includes timing control circuitry for selectively controlling the output of the CCD detector so that video outputs are provided only with respect to induced charges corresponding to predetermined sensing element lines of the CCD detector. The timing control circuit and the analog to digital converter are controlled by a programmed microprocessor which defines the video outputs to be converted and further controls the timing control circuit so that no video outputs are provided during the delay associated with analog to digital conversion.

Salomon, P. M.↗