Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “publishing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Experimental cross sections for L-shell x-ray production and ionization by protons

Tables of compiled cross sections list data for production of individual line and total L x-rays as well as for ionization of L subshells and the total L shell. The present cumulative compilation covers some six decades of measurements on targets from {sub 10}Ne to {sub 95}Am bombarded by protons ranging from 10 keV to 1 GeV. It includes data published in the period 1954–1992 from tables published in this journal, cross sections that were not reported in those tables, and new data from works published after 1992. Existing empirical, semiempirical, and theoretical analyses based on, and relative to, the pre-1993 database are reviewed. The experimental details are summarized for pre-1993 articles that were not referenced in previous compilations and, continuing the practice of these compilations, for each new publication. Covering the period 1954–December 2012, the present tabulation collects (not counting 2519 new data for L{sub β1,3,4}, L{sub β2,15},L{sub γ1}, L{sub γ2,3}, and L{sub γ4,4{sup ′}} x ray production) circa 15 500 experimental cross sections and enlarges the database from the previously published tables by 94%. -- Highlights: •An updated database is presented, increasing by 94% the earlier pre-1993 database. •The update has 40% more data from the pre-1993 period, absent in prior compilations. •The growth and possible saturation in the number of data is illustrated. •Ionization cross sections are reconverted to x-ray production cross sections. •Elements and ion energies are identified where measurements are still necessary.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Standards, dissemination, and best practices in systems biology

In this study, the reproducibility of scientific research is crucial to the success of the scientific method. Here, we review the current best practices when publishing mechanistic models in systems biology. We recommend, where possible, to use software engineering strategies such as testing, verification, validation, documentation, versioning, iterative development, and continuous integration. In addition, adhering to the Findable, Accessible, Interoperable, and Reusable modeling principles allows other scientists to collaborate and build off of each other’s work. Existing standards such as Systems Biology Markup Language, CellML, or Simulation Experiment Description Markup Language can greatly improve the likelihood that a published model is reproducible, especially if such models are deposited in well-established model repositories. Where models are published in executable programming languages, the source code and their data should be published as open-source in public code repositories together with any documentation and testing code. For complex models, we recommend container-based solutions where any software dependencies and the run-time context can be easily replicated.

59 BASIC BIOLOGICAL SCIENCES↗

Named Entity Recognition and Normalization Applied to Large-Scale Information Extraction from the Materials Science Literature

The number of published materials science articles has increased manyfold over the past few decades. Now, a major bottleneck in the materials discovery pipeline arises in connecting new results with the previously established literature. A potential solution to this problem is to map the unstructured raw text of published articles onto structured database entries that allow for programmatic querying. To this end, we apply text mining with named entity recognition (NER) for large-scale information extraction from the published materials science literature. The NER model is trained to extract summary-level information from materials science documents, including inorganic material mentions, sample descriptors, phase labels, material properties and applications, as well as any synthesis and characterization methods used. Our classifier achieves an accuracy (f 1 ) of 87%, and is applied to information extraction from 3.27 million materials science abstracts. We extract more than 80 million materials-science-related named entities, and the content of each abstract is represented as a database entry in a structured format. We demonstrate that simple database queries can be used to answer complex "meta-questions" of the published literature that would have previously required laborious, manual literature searches to answer. Finally, all of our data and functionality has been made freely available on our Github ( https://github.com/materialsintelligence/matscholar ) and website ( http://matscholar.com ), and we expect these results to accelerate the pace of future materials science discovery.

36 MATERIALS SCIENCE↗

An Assessment of Global Positioning System Velocity Uncertainty in California

We analyze data from 580 continuous global positioning system (GPS) stations in California to quantify differences in published velocity estimates from five analysis centers. Horizontal and vertical rates for individual stations can differ up to 5 mm/yr, with systematic differences in some areas comparable to deformation rates. Published velocity uncertainties vary between analysis centers and are systematically underreported in the horizontal relative to empirical uncertainties calculated from the scatter of analysis center velocities. In the vertical, published velocity uncertainties are both over and underreported and vary more widely between centers. An interpolated ensemble vertical velocity field shows high-subsidence regions in the Central Valley and Salton Trough have the largest empirical uncertainties, while station density has a modest impact on uncertainties. Applications that rely on subcentimeter GPS accuracy should consider the possibility that formal errors published with velocity rate estimates understate true velocity uncertainties in both the horizontal and vertical.

54 ENVIRONMENTAL SCIENCES↗

Analysis of a multi-machine database on divertor heat fluxes

A coordinated effort to measure divertor heat flux characteristics in fully attached, similarly shaped H-mode plasmas on C-Mod, DIII-D, and NSTX was carried out in 2010 in order to construct a predictive scaling relation applicable to next step devices including ITER, FNSF, and DEMO. Few published scaling laws are available and those that have been published were obtained under widely varying conditions and divertor geometries, leading to conflicting predictions for this critically important quantity. This study was designed to overcome these deficiencies. Analysis of the combined data set reveals that the primary dependence of the parallel heat flux width is robustly inverse with I{sub p}, which all three tokamaks independently demonstrate. An improved Thomson scattering system on DIII-D has yielded very accurate scrape off layer (SOL) profile measurements from which tests of parallel transport models have been made. It is found that a flux-limited model agrees best with the data at all collisionalities, while a Spitzer resistivity model agrees at higher collisionality where it is more valid. The SOL profile measurements and divertor heat flux scaling are consistent with a heuristic drift based model as well as a critical gradient model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Behavior of IAPWS-95 from 250 to 300 K and Pressures up to 400 MPa: Evaluation Based on Recently Derived Property Data

Over the past several years, considerable scientific and technical interest has been focused on accurate thermodynamic properties of fluid water covering part of the subcooled (metastable) region and the stable liquid from the melting line up to about 300 K and pressures up to several hundred MPa. Between 2000 and 2010, experimental density data were published whose accuracy was not completely clear. The scientific standard equation of state for fluid water, the IAPWS-95 formulation, was developed on the basis of experimental data for thermodynamic properties that were available by 1995. In this work, it is examined how IAPWS-95 behaves with respect to the experimental data published after 1995. This investigation is carried out for temperatures from 250 to 300 K and pressures up to 400 MPa. The starting point is the assessment of the current data situation. This was mainly performed on the basis of data for the density, expansivity, compressibility, and isobaric heat capacity, which were derived in 2015 from very accurate speed-of-sound data. Apart from experimental data and these derived data, property values calculated from the recently published equation of state for this region of Holten et al. (2014) were also used. As a result, the unclear data situation could be clarified, and uncertainty values could be estimated for the investigated properties. In the region described above, detailed comparisons show that IAPWS-95 is able to represent the latest experimental data for the density, expansivity, compressibility, speed of sound, and isobaric heat capacity to within the uncertainties given in the release on IAPWS-95. Since the release does not contain uncertainty estimates for expansivities and compressibilities, the statement relates to the error propagation of the given uncertainty in density. Due to the lack of experimental data for the isobaric heat capacity for pressures above 100 MPa, no uncertainty estimates are given in the release for this pressure range. Results of the investigation of IAPWS-95 concerning its behavior with regard to the isobaric heat capacity in the high-pressure low-temperature region are also presented. Comparisons with very accurate speed-of-sound data published in 2012 showed that the uncertainty estimates of IAPWS-95 in speed of sound could be decreased for temperatures from 283 to 473 K and pressures up to 400 MPa.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Constraints on the CMB temperature evolution using multiband measurements of the Sunyaev-Zel'dovich effect with the South Pole Telescope

The adiabatic evolution of the temperature of the cosmic microwave background (CMB) is a key prediction of standard cosmology. We study deviations from the expected adiabatic evolution of the CMB temperature of the form T(z) = T 0 (1 + z) 1 - α using measurements of the spectrum of the Sunyaev–Zel'dovich effect with the South Pole Telescope (SPT). We present a method for using the ratio of the Sunyaev–Zel'dovich signal measured at 95 and 150 GHz in the SPT data to constrain the temperature of the CMB. We demonstrate that this approach provides unbiased results using mock observations of clusters from a new set of hydrodynamical simulations. We apply this method to a sample of 158 SPT-selected clusters, spanning the redshift range 0.05 < z < 1.35, and measure $\alpha = 0.017^{+0.030}_{-0.028}$, consistent with the standard model prediction of α = 0. In combination with other published results, we find α = 0.005 ± 0.012, an improvement of ~10 percent over published constraints. This measurement also provides a strong constraint on the effective equation of state in models of decaying dark energy w eff = -0.994 ± 0.010.

79 ASTRONOMY AND ASTROPHYSICS↗

The Dark Energy Survey: more than dark energy – an overview

This overview paper describes the legacy prospect and discovery potential of the Dark Energy Survey (DES) beyond cosmological studies, illustrating it with examples from the DES early data. DES is using a wide-field camera (DECam) on the 4 m Blanco Telescope in Chile to image 5000 sq deg of the sky in five filters (grizY). By its completion, the survey is expected to have generated a catalogue of 300 million galaxies with photometric redshifts and 100 million stars. In addition, a time-domain survey search over 27 sq deg is expected to yield a sample of thousands of Type Ia supernovae and other transients. The main goals of DES are to characterize dark energy and dark matter, and to test alternative models of gravity; these goals will be pursued by studying large-scale structure, cluster counts, weak gravitational lensing and Type Ia supernovae. However, DES also provides a rich data set which allows us to study many other aspects of astrophysics. In this paper, we focus on additional science with DES, emphasizing areas where the survey makes a difference with respect to other current surveys. The paper illustrates, using early data (from ‘Science Verification’, and from the first, second and third seasons of observations), what DES can tell us about the Solar system, the Milky Way, galaxy evolution, quasars and other topics. In addition, we show that if the cosmological model is assumed to be Λ+cold dark matter, then important astrophysics can be deduced from the primary DES probes. Highlights from DES early data include the discovery of 34 trans-Neptunian objects, 17 dwarf satellites of the Milky Way, one published z > 6 quasar (and more confirmed) and two published superluminous supernovae (and more confirmed).

79 ASTRONOMY AND ASTROPHYSICS↗

Life Cycle Greenhouse Gas Emissions of Crystalline Silicon Photovoltaic Electricity Generation: Systematic Review and Harmonization

Published scientific literature contains many studies estimating life cycle greenhouse gas (GHG) emissions of residential and utility-scale solar photovoltaics (PVs). Despite the volume of published work, variability in results hinders generalized conclusions. Most variance between studies can be attributed to differences in methods and assumptions. To clarify the published results for use in decision making and other analyses, we conduct a meta-analysis of existing studies, harmonizing key performance characteristics to produce more comparable and consistently derived results. Screening 397 life cycle assessments (LCAs) relevant to PVs yielded 13 studies on crystalline silicon (c-Si) that met minimum standards of quality, transparency, and relevance. Prior to harmonization, the median of 42 estimates of life cycle GHG emissions from those 13 LCAs was 57 grams carbon dioxide equivalent per kilowatt-hour (g CO{sub 2}-eq/kWh), with an interquartile range (IQR) of 44 to 73. After harmonizing key performance characteristics, irradiation of 1,700 kilowatt-hours per square meter per year (kWh/m{sup 2}/yr); system lifetime of 30 years; module efficiency of 13.2% or 14.0%, depending on module type; and a performance ratio of 0.75 or 0.80, depending on installation, the median estimate decreased to 45 and the IQR tightened to 39 to 49. The median estimate and variability were reduced compared to published estimates mainly because of higher average assumptions for irradiation and system lifetime. For the sample of studies evaluated, harmonization effectively reduced variability, providing a clearer synopsis of the life cycle GHG emissions from c-Si PVs. The literature used in this harmonization neither covers all possible c-Si installations nor represents the distribution of deployed or manufactured c-Si PVs.

14 SOLAR ENERGY↗

Organ doses for reference pediatric and adolescent patients undergoing computed tomography estimated by Monte Carlo simulation

Purpose: To establish an organ dose database for pediatric and adolescent reference individuals undergoing computed tomography (CT) examinations by using Monte Carlo simulation. The data will permit rapid estimates of organ and effective doses for patients of different age, gender, examination type, and CT scanner model. Methods: The Monte Carlo simulation model of a Siemens Sensation 16 CT scanner previously published was employed as a base CT scanner model. A set of absorbed doses for 33 organs/tissues normalized to the product of 100 mAs and CTDI{sub vol} (mGy/100 mAs mGy) was established by coupling the CT scanner model with age-dependent reference pediatric hybrid phantoms. A series of single axial scans from the top of head to the feet of the phantoms was performed at a slice thickness of 10 mm, and at tube potentials of 80, 100, and 120 kVp. Using the established CTDI{sub vol}- and 100 mAs-normalized dose matrix, organ doses for different pediatric phantoms undergoing head, chest, abdomen-pelvis, and chest-abdomen-pelvis (CAP) scans with the Siemens Sensation 16 scanner were estimated and analyzed. The results were then compared with the values obtained from three independent published methods: CT-Expo software, organ dose for abdominal CT scan derived empirically from patient abdominal circumference, and effective dose per dose-length product (DLP). Results: Organ and effective doses were calculated and normalized to 100 mAs and CTDI{sub vol} for different CT examinations. At the same technical setting, dose to the organs, which were entirely included in the CT beam coverage, were higher by from 40 to 80% for newborn phantoms compared to those of 15-year phantoms. An increase of tube potential from 80 to 120 kVp resulted in 2.5-2.9-fold greater brain dose for head scans. The results from this study were compared with three different published studies and/or techniques. First, organ doses were compared to those given by CT-Expo which revealed dose differences up to several-fold when organs were partially included in the scan coverage. Second, selected organ doses from our calculations agreed to within 20% of values derived from empirical formulae based upon measured patient abdominal circumference. Third, the existing DLP-to-effective dose conversion coefficients tended to be smaller than values given in the present study for all examinations except head scans. Conclusions: A comprehensive organ/effective dose database was established to readily calculate doses for given patients undergoing different CT examinations. The comparisons of our results with the existing studies highlight that use of hybrid phantoms with realistic anatomy is important to improve the accuracy of CT organ dosimetry. The comprehensive pediatric dose data developed here are the first organ-specific pediatric CT scan database based on the realistic pediatric hybrid phantoms which are compliant with the reference data from the International Commission on Radiological Protection (ICRP). The organ dose database is being coupled with an adult organ dose database recently published as part of the development of a user-friendly computer program enabling rapid estimates of organ and effective dose doses for patients of any age, gender, examination types, and CT scanner model.

61 RADIATION PROTECTION AND DOSIMETRY↗

A parameterization method and application in breast tomosynthesis dosimetry

Purpose: To present a parameterization method based on singular value decomposition (SVD), and to provide analytical parameterization of the mean glandular dose (MGD) conversion factors from eight references for evaluating breast tomosynthesis dose in the Mammography Quality Standards Act (MQSA) protocol and in the UK, European, and IAEA dosimetry protocols.Methods: MGD conversion factor is usually listed in lookup tables for the factors such as beam quality, breast thickness, breast glandularity, and projection angle. The authors analyzed multiple sets of MGD conversion factors from the Hologic Selenia Dimensions quality control manual and seven previous papers. Each data set was parameterized using a one- to three-dimensional polynomial function of 2–16 terms. Variable substitution was used to improve accuracy. A least-squares fit was conducted using the SVD.Results: The differences between the originally tabulated MGD conversion factors and the results computed using the parameterization algorithms were (a) 0.08%–0.18% on average and 1.31% maximum for the Selenia Dimensions quality control manual, (b) 0.09%–0.66% on average and 2.97% maximum for the published data by Dance et al. [Phys. Med. Biol. 35, 1211–1219 (1990); ibid. 45, 3225–3240 (2000); ibid. 54, 4361–4372 (2009); ibid. 56, 453–471 (2011)], (c) 0.74%–0.99% on average and 3.94% maximum for the published data by Sechopoulos et al. [Med. Phys. 34, 221–232 (2007); J. Appl. Clin. Med. Phys. 9, 161–171 (2008)], and (d) 0.66%–1.33% on average and 2.72% maximum for the published data by Feng and Sechopoulos [Radiology 263, 35–42 (2012)], excluding one sample in (d) that does not follow the trends in the published data table.Conclusions: A flexible parameterization method is presented in this paper, and was applied to breast tomosynthesis dosimetry. The resultant data offer easy and accurate computations of MGD conversion factors for evaluating mean glandular breast dose in the MQSA protocol and in the UK, European, and IAEA dosimetry protocols. Microsoft Excel™ spreadsheets are provided for the convenience of readers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an {sup 192}Ir brachytherapy source

Purpose: The absorbed dose to water is the fundamental reference quantity for brachytherapy treatment planning systems and thermoluminescence dosimeters (TLDs) have been recognized as the most validated detectors for measurement of such a dosimetric descriptor. The detector response in a wide energy spectrum as that of an{sup 192}Ir brachytherapy source as well as the specific measurement medium which surrounds the TLD need to be accounted for when estimating the absorbed dose. This paper develops a methodology based on highly sensitive LiF:Mg,Cu,P TLDs to directly estimate the absorbed dose to water in liquid water around a high dose rate {sup 192}Ir brachytherapy source. Methods: Different experimental designs in liquid water and air were constructed to study the response of LiF:Mg,Cu,P TLDs when irradiated in several standard photon beams of the LNE-LNHB (French national metrology laboratory for ionizing radiation). Measurement strategies and Monte Carlo techniques were developed to calibrate the LiF:Mg,Cu,P detectors in the energy interval characteristic of that found when TLDs are immersed in water around an{sup 192}Ir source. Finally, an experimental system was designed to irradiate TLDs at different angles between 1 and 11 cm away from an {sup 192}Ir source in liquid water. Monte Carlo simulations were performed to correct measured results to provide estimates of the absorbed dose to water in water around the {sup 192}Ir source. Results: The dose response dependence of LiF:Mg,Cu,P TLDs with the linear energy transfer of secondary electrons followed the same variations as those of published results. The calibration strategy which used TLDs in air exposed to a standard N-250 ISO x-ray beam and TLDs in water irradiated with a standard{sup 137}Cs beam provided an estimated mean uncertainty of 2.8% (k = 1) in the TLD calibration coefficient for irradiations by the {sup 192}Ir source in water. The 3D TLD measurements performed in liquid water were obtained with a maximum uncertainty of 11% (k = 1) found at 1 cm from the source. Radial dose values in water were compared against published results of the American Association of Physicists in Medicine and the European Society for Radiotherapy and Oncology and no significant differences (maximum value of 3.1%) were found within uncertainties except for one position at 9 cm (5.8%). At this location the background contribution relative to the TLD signal is relatively small and an unexpected experimental fluctuation in the background estimate may have caused such a large discrepancy. Conclusions: This paper shows that reliable measurements with TLDs in complex energy spectra require a study of the detector dose response with the radiation quality and specific calibration methodologies which model accurately the experimental conditions where the detectors will be used. The authors have developed and studied a method with highly sensitive TLDs and contributed to its validation by comparison with results from the literature. This methodology can be used to provide direct estimates of the absorbed dose rate in water for irradiations with HDR{sup 192}Ir brachytherapy sources.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FEM design and simulation of a short, 10 MV, S-band Linac with Monte Carlo dose simulations

Purpose: Current commercial 10 MV Linac waveguides are 1.5 m. The authors’ current 6 MV linear accelerator–magnetic resonance imager (Linac–MR) system fits in typical radiotherapy vaults. To allow 10 MV treatments with the Linac–MR and still fit within typical vaults, the authors design a 10 MV Linac with an accelerator waveguide of the same length (27.5 cm) as current 6 MV Linacs. Methods: The first design stage is to design a cavity such that a specific experimental measurement for breakdown is applicable to the cavity. This is accomplished through the use of finite element method (FEM) simulations to match published shunt impedance, Q factor, and ratio of peak to mean-axial electric field strength from an electric breakdown study. A full waveguide is then designed and tuned in FEM simulations based on this cavity design. Electron trajectories are computed through the resulting radio frequency fields, and the waveguide geometry is modified by shifting the first coupling cavity in order to optimize the electron beam properties until the energy spread and mean energy closely match values published for an emulated 10 MV Linac. Finally, Monte Carlo dose simulations are used to compare the resulting photon beam depth dose profile and penumbra with that produced by the emulated 10 MV Linac. Results: The shunt impedance, Q factor, and ratio of peak to mean-axial electric field strength are all matched to within 0.1%. A first coupling cavity shift of 1.45 mm produces an energy spectrum width of 0.347 MeV, very close to the published value for the emulated 10 MV of 0.315 MeV, and a mean energy of 10.53 MeV, nearly identical to the published 10.5 MeV for the emulated 10 MV Linac. The depth dose profile produced by their new Linac is within 1% of that produced by the emulated 10 MV spectrum for all depths greater than 1.5 cm. The penumbra produced is 11% narrower, as measured from 80% to 20% of the central axis dose. Conclusions: The authors have successfully designed and simulated an S-band waveguide of length of 27.5 cm capable of producing a 10 MV photon beam. This waveguide operates well within the breakdown threshold determined for the cavity geometry used. The designed Linac produces depth dose profiles similar to those of the emulated 10 MV Linac (waveguide-length of 1.5 m) but yields a narrower penumbra.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-554: Monte Carlo Calculation of Source Terms and Attenuation Lengths for Neutrons Produced by 50–200 MeV Protons On Brass

Purpose: We used TOPAS (TOPAS wraps and extends Geant4 for medical physicists) to compare Geant4 physics models with published data for neutron shielding calculations. Subsequently, we calculated the source terms and attenuation lengths (shielding data) of the total ambient dose equivalent (TADE) in concrete for neutrons produced by protons in brass. Methods: Stage1: The Bertini and Binary nuclear models available in Geant4 were compared with published attenuation at depth of the TADE in concrete and iron. Stage2: Shielding data of the TADE in concrete was calculated for 50– 200 MeV proton beams on brass. Stage3: Shielding data from Stage2 was extrapolated for 235 MeV proton beams. This data was used in a point-line-source analytical model to calculate the ambient dose per unit therapeutic dose at two locations inside one treatment room at the Francis H Burr Proton Therapy Center. Finally, we compared these results with experimental data and full TOPAS simulations. Results: At larger angles (∼130o) the TADE in concrete calculated with the Bertini model was about 9 times larger than that calculated with the Binary model. The attenuation length in concrete calculated with the Binary model agreed with published data within 7%±0.4% (statistical uncertainty) for the deepest regions and 5%±0.1% for shallower regions. For iron the agreement was within 3%±0.1%. The ambient dose per therapeutic dose calculated with the Binary model, relative to the experimental data, was a ratio of 0.93±0.16 and 1.23±0.24 for two locations. The analytical model overestimated the dose by four orders of magnitude. These differences are attributed to the complexity of the geometry. Conclusion: The Binary and Bertini models gave comparable results, with the Binary model giving the best agreement with published data at large angle. Shielding data we calculated using the Binary model is useful for fast shielding calculations with other analytical models. This work was supported by National Cancer Institute Grant R01CA140735.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-23: Correspondence Factor Correction Coefficient for Commissioning of Leipzig and Valencia Applicators with the Standard Imaging IVB 1000

Purpose: To determine the correction factor of the correspondence factor for the Standard Imaging IVB 1000 well chamber for commissioning of Elekta’s Leipzig and Valencia skin applicators. Methods: The Leipzig and Valencia applicators are designed to treat small skin lesions by collimating irradiation to the treatment area. Published output factors are used to calculate dose rates for clinical treatments. To validate onsite applicators, a correspondence factor (CFrev) is measured and compared to published values. The published CFrev is based on well chamber model SI HDR 1000 Plus. The CFrev is determined by correlating raw values of the source calibration setup (Rcal,raw) and values taken when each applicator is mounted on the same well chamber with an adapter (Rapp,raw). The CFrev is calculated by using the equation CFrev =Rapp,raw/Rcal,raw. The CFrev was measured for each applicator in both the SI HDR 1000 Plus and the SI IVB 1000. A correction factor, CFIVB for the SI IVB 1000 was determined by finding the ratio of CFrev (SI IVB 1000) and CFrev (SI HDR 1000 Plus). Results: The average correction factors at dwell position 1121 were found to be 1.073, 1.039, 1.209, 1.091, and 1.058 for the Valencia V2, Valencia V3, Leipzig H1, Leipzig H2, and Leipzig H3 respectively. There were no significant variations in the correction factor for dwell positions 1119 through 1121. Conclusion: By using the appropriate correction factor, the correspondence factors for the Leipzig and Valencia surface applicators can be validated with the Standard Imaging IVB 1000. This allows users to correlate their measurements with the Standard Imaging IVB 1000 to the published data. The correction factor is included in the equation for the CFrev as follows: CFrev= Rapp,raw/(CFIVB*Rcal,raw). Each individual applicator has its own correction factor, so care must be taken that the appropriate factor is used.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP2-03: Validation of an SSDE-To-Organ-Dose Calculation Methodology Developed for Pediatric CT in An Adult Population

Purpose: To discover if a previously published methodology for estimating patient-specific organ dose in a pediatric population (5–55kg) is translatable to the adult sized patient population (> 55 kg). Methods: An adult male anthropomorphic phantom was scanned with metal oxide semiconductor field effect transistor (MOSFET) dosimeters placed at 23 organ locations in the chest and abdominopelvic regions to determine absolute organ dose. Organ-dose-to-SSDE correlation factors were developed by dividing individual phantom organ doses by SSDE of the phantom; where SSDE was calculated at the center of the scan volume of the chest and abdomen/pelvis separately. Organ dose correlation factors developed in phantom were multiplied by 28 chest and 22 abdominopelvic patient SSDE values to estimate organ dose. The median patient weight from the CT examinations was 68.9 kg (range 57–87 kg) and median age was 17 years (range 13–28 years). Calculated organ dose estimates were compared to published Monte Carlo simulated patient and phantom results. Results: Organ-dose-to-SSDE correlation was determined for a total of 23 organs in the chest and abdominopelvic regions. For organs fully covered by the scan volume, correlation in the chest (median 1.3; range 1.1–1.5) and abdominopelvic (median 0.9; range 0.7–1.0) was 1.0 ± 10%. For organs that extended beyond the scan volume (i.e. skin bone marrow and bone surface) correlation was determined to be a median of 0.3 (range 0.1–0.4). Calculated patient organ dose using patient SSDE agreed to better than 6% (chest) and 15% (abdominopelvic) to published values. Conclusion: This study demonstrated that our previous published methodology for calculating organ dose using patient-specific SSDE for the chest and abdominopelvic regions is translatable to adult sized patients for organs fully covered by the scan volume.

60 APPLIED LIFE SCIENCES↗

Review of Particle Physics

The Review summarizes much of particle physics and cosmology. Using data from previous editions, plus 3,200 new measurements from 903 papers, we list, evaluate, and average measured properties of gauge bosons and the recently discovered Higgs boson, leptons, quarks, mesons, and baryons. We summarize searches for hypothetical particles such as supersymmetric particles, heavy bosons, axions, dark photons, etc. Particle properties and search limits are listed in Summary Tables. We give numerous tables, figures, formulae, and reviews of topics such as Higgs Boson Physics, Supersymmetry, Grand Unified Theories, Neutrino Mixing, Dark Energy, Dark Matter, Cosmology, Particle Detectors, Colliders, Probability and Statistics. Most of the 118 reviews are updated, including many that are heavily revised.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗