Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

HighNESS conceptual design report: Volume I

The European Spallation Source, currently under construction in Lund, Sweden, is a multidisciplinary international laboratory. Once completed to full specifications, it will operate the world’s most powerful pulsed neutron source. Supported by a 3 million Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) has been completed to develop a second neutron source located below the spallation target. Compared to the first source, designed for high cold and thermal brightness, the new source has been optimized to deliver higher intensity, and a shift to longer wavelengths in the spectral regions of cold (CN, 2–20 Å), very cold (VCN, 10–120 Å), and ultracold (UCN, >500 Å) neutrons. The second source comprises a large liquid deuterium moderator designed to produce CN and support secondary VCN and UCN sources. Various options have been explored in the proposed designs, aiming for world-leading performance in neutronics. These designs will enable the development of several new instrument concepts and facilitate the implementation of a high-sensitivity neutron-antineutron oscillation experiment (NNBAR). This document serves as the Conceptual Design Report for the HighNESS project, representing its final deliverable.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

µRWELL-PICOSEC: The Development of Fast Timing Resistive Micro-WELL Detector Technology.

We present the development of a new concept of fast timing gaseous detector, the ?RWELL-PICOSEC detector based on Resistive Micro-Well (?RWELL) technology to provide timing resolution in the tens of picosecond range for application as time-of-flight (TOF) technology in the particle physics and medical instrumentation fields. The ?RWELL-PICOSEC technology combined a Cerenkov radiator for the generation of Cerenkov photons from high energy charged particles, a photocathode for the conversion of the produced photons into primary electrons and the ?RWELL foil for the multiplication of the electron to produce large signal on pad segmentation readout. The proof of concept of ?RWELL-PICOSEC is demonstrated with a small single-channel prototype and preliminary timing performance of 90 ps has been measured. Optimization study the amplification structure of ?RWELL-PICOSEC for the improvement of timing resolution is discussed and results on timing performance studies in beam at CERN are presented. The development of large area (100 mm × 100 mm) ?RWELL-PICOSEC and associated multichannel fast readout electronics and data acquisition system are also reported

Weisenberger, Andrew↗

A new class of variable-radii diffraction optics for high-resolution x-ray spectroscopy at the National Ignition Facility (invited)

A new class of crystal shapes has been developed for x-ray spectroscopy of point-like or small (a few mm) emission sources. These optics allow for dramatic improvement in both achievable energy resolution and total throughput of the spectrometer as compared with traditional designs. This class of crystal shapes, collectively referred to as the Variable-Radii Spiral (VR-Spiral), utilize crystal shapes in which both the major and minor radii are variable. A crystal using this novel VR-Spiral shape has now been fabricated for high-resolution Extended X-ray Absorption Fine Structure (EXAFS) experiments targeting the Pb-L 3 (13.0 keV) absorption edge at the National Ignition Facility. The performance of this crystal has been characterized in the laboratory using a microfocus x-ray source, showing that high-resolution high-throughput EXAFS spectra can be acquired using this geometry. Importantly, these successful tests show that the complex three-dimensional crystal shape is manufacturable with the required precision needed to realize the expected performance of better than 5 eV energy resolution while using a 30 mm high crystal. An improved generalized mathematical form for VR-Spiral shapes is also presented allowing improved optimization as compared to the first sinusoidal-spiral based design. Finally, this new formulation allows VR-Spiral spectrometers to be designed at any magnification with optimized energy resolution at all energies within the spectrometer bandwidth.

47 OTHER INSTRUMENTATION↗

Contrast optimization of Fresnel zone plate imaging

Fresnel zone plates (FZPs) are circular diffractive elements that operate as a lens for x-rays. They have gained interest in the field of laser-plasma physics due to their ability to achieve higher spatial resolution than pinholes. Their design and implementation are complicated by the fact that a significant amount of the x-rays passing through the FZP will not diffract (zeroth order) and present a background to the measurement. This background can be large and inhomogeneous depending on the geometric setup of the experiment. Furthermore, we present calculations of the diffracted (first order) and un-diffracted (zeroth order) flux profiles, which makes it possible to optimize the contrast between the first order imaging rays and the zeroth order background. Calculations for the implementation of a central block in the FZP, designed to block the zeroth from the entire field of view, are also presented.

47 OTHER INSTRUMENTATION↗

Machine-learning-assisted automation of single-crystal neutron diffraction

Neutron scattering is a powerful but expensive technique to study materials and discover new matter. Advanced detector technology has significantly improved the efficiency of neutron experiments, increasing the complexity of neutron data reduction and analysis. Machine learning (ML) brings new directions for neutron diffraction data reduction and experiment operation. Here, this work presents an ML-assisted data reduction and analysis method for precise recognition of Bragg peaks and the corresponding regions of interest; it can then automatically screen and align a measured crystal using the recognized peaks, and subsequently plan and optimize the data collection with user-provided information and uncertainty quantification values of detected peaks. This method shows robust performance in different complex sample environments and enables automated single-crystal neutron diffraction.

47 OTHER INSTRUMENTATION↗

PET Imaging of Leg Arteries for Determining the Input Function in PET/MRI Brain Studies Using a Compact, MRI-Compatible PET System

In this work, we used a compact, high-resolution, and magnetic resonance imaging (MRI)-compatible positron emission tomography (PET) camera (VersaPET) to assess the feasibility of measuring the image-derived input function (IDIF) from arteries in the leg with the ultimate goal of enabling fully quantitative PET brain imaging without blood sampling. We used this approach in five 18 F-FDG PET/MRI brain studies in which the input function was also acquired using the gold standard of serial arterial blood sampling. After accounting for partial volume, dispersion, and calibration effects, we compared the metabolic rates of glucose (MRglu) quantified from VersaPET IDIFs in 80 brain regions to those using the gold standard and achieved a bias and variability of <5% which is within the range of reported test-retest values for this type of study. We also achieved a strong linear relationship (R 2 >0.97) against the gold standard across regions. The results of this preliminary study are promising and support further studies to optimize methods, validate in a larger cohort, and extend to the modeling of other radiotracers.

47 OTHER INSTRUMENTATION↗

Development of an immersion fiber optic Raman probe for real-time analysis of molten materials

This study presents an advancement in high-temperature Raman spectroscopy, specifically for analyzing molten materials. It introduces an approach by integrating a fiber-optic Raman probe with a copper block protection system designed to endure extreme thermal conditions. The copper block features an open port designed to accommodate an external telescope with a 3 cm focal length, enabling Raman spectra collection in challenging high-temperature environments. A built-in gas channel ensures a continuous flow of argon gas to prevent flux intrusion. The robust copper block acts as a reliable shield, safeguarding the fiber-optic Raman probe within molten materials. This enhancement maintains the probe's integrity and significantly improves its resilience, making it ideal for rigorous investigations of molten substances. This advancement is particularly relevant in metallurgy, where flux materials impact production quality and efficiency. The ability to acquire Raman signals under elevated thermal conditions offers opportunities for studying molecular dynamics, compositional changes, and chemical interactions within molten substances. This introduced direct immersion probing technique has implications, benefiting both scientific and industrial fields. It holds promise for advancing research and exploration in various contexts, from fundamental scientific inquiries to practical applications in metallurgical processes, where flux materials are critical for optimizing production quality and efficiency. Furthermore, this approach enhances the capabilities of high-temperature Raman spectroscopy, making it a valuable tool for investigating molten materials and their properties in diverse settings.

Argon↗

The Dark Energy Spectrographic Instrument (DESI) Optical Fiber System

The specific research of the DESI project is to study in detail the expansion history of the Universe over the past 10 billion years. In order to do this, the project designed, fabricated, tested and commissioned the DESI instrument which has been deployed at the Mayall Telescope at the Kitt Peak National Observatory near Tucson, Arizona. The DESI project was conducted by approximately 30 US and foreign national laboratories. The complete instrument includes a prime focus corrector assembly, a focal plane with 5,000 optical fibers whose position can be set by robotic positioners, and ten spectrographs. Each spectrograph can accommodate the light from 500 fibers and include three color channels that are illuminated by a common collimator mirror and other planar transfer optics. In order for this entire system to work, optical fibers are required to connect each positioner to the spectrographs. Our CRADA with Durham University in the UK provided the 10 crucial fiber cables required to connect the DESI focal plane to the 10 spectrographs. The key major goals of this CRADA were achieved. Survey planning was another key component to the Durham contribution. Drs. Frenk, Baugh, Cole, Edge, Lacey, Li, Lucey, Massey, Metcalfe, Norberg and Shanks were all important contributors to the working groups to which they were assigned. Their work to implement emission lines and QSO in lightcone mocks, mocks for non-standard cosmologies/modified gravity, optimization of completeness of BGS in crowded regions and extended source photometry have been vital in the early planning for targets during commissioning. The major role in the project involved Dr. Ray Sharples and his team. They provided a significant portion of the design, fabrication and testing of the optical fiber system. In particular, they were responsible for the design, production of engineering drawings, component procurements, and fabrication of the 10 DESI Science fiber cables. Working in close collaboration with Dr. Claire Poppett, they also designed and fabricated the slit assemblies, the specialized termination of the groups of 500 fibers which plug into the spectrographs.

47 OTHER INSTRUMENTATION↗

Improved optical standing-wave beam splitters for dilute Bose–Einstein condensates

Bose–Einstein condensate (BEC)-based atom interferometry exploits low temperatures and long coherence lengths to facilitate high-precision measurements. Progress in atom interferometry promises improvements in navigational devices like gyroscopes and accelerometers, as well as applications in fundamental physics such as accurate determination of physical constants. Previous work demonstrates that beam splitters and mirrors for coherent manipulation of dilute BEC momentum in atom interferometers can be implemented with sequences of non-resonant standing-wave light pulses. While previous work focuses on the optimization of the optical pulses’ amplitude and duration to produce high-order momentum states with high fidelity, we explore how varying the shape of the optical pulses affects optimal beam-splitter performance, as well as the effect of pulse shape on the sensitivity of optimized parameters in achieving high fidelity in high-momentum states. Here, in simulations of two-pulse beam splitters utilizing optimized square, triangle, and sinc-squared pulse shapes applied to dilute BECs, we, in some cases, reduce parameter sensitivity by an order of magnitude while maintaining fidelity.

74 ATOMIC AND MOLECULAR PHYSICS↗

A customizable data management framework for high-repetition-rate high-energy-density science

The high-energy-density (HED) physics community is moving toward a new paradigm of high-repetition-rate (HRR) operation. To fully leverage the scientific power of HRR HED facilities, all of the components of each subsystem (laser, targetry, and performance diagnostics) must be connected and synchronized in a reliable and robust manner while the data acquired are tagged and archived in real time. To this end, GA has begun developing a generalized NoSQL-database framework, the MongoDB repository for information and archiving. An organizational strategy has been developed that shifts HED data organization from a shot-based to a diagnostic-based approach in order to increase archival and retrieval efficiency that lends itself to optimization applications. This work is a first step in pushing HRR HED science toward data management solutions that emphasize machine actionability and aim to stimulate community engagement to define data standards in HED science.

Instruments & Instrumentation↗

The FRB-searching Pipeline of the Tianlai Cylinder Pathfinder Array

This paper presents the design, calibration, and survey strategy of the Fast Radio Burst (FRB) digital backend and its real-time data processing pipeline employed in the Tianlai Cylinder Pathfinder Array. The array, consisting of three parallel cylindrical reflectors and equipped with 96 dual-polarization feeds, is a radio interferometer array designed for conducting drift scans of the northern celestial semi-sphere. The FRB digital backend enables the formation of 96 digital beams, effectively covering an area of approximately 40 square degrees with the 3 dB beam. Our pipeline demonstrates the capability to conduct an automatic search of FRBs, detecting at quasi-real-time and classifying FRB candidates automatically. The current FRB searching pipeline has an overall recall rate of 88%. During the commissioning phase, we successfully detected signals emitted by four well-known pulsars: PSR B0329+54, B2021+51, B0823+26, and B2020+28. We report the first discovery of an FRB by our array, designated as FRB 20220414A. We also investigate the optimal arrangement for the digitally formed beams to achieve maximum detection rate by numerical simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mitigating the noise of DESI mocks using analytic control variates

In order to address fundamental questions related to the expansion history of the Universe and its primordial nature with the next generation of galaxy experiments, we need to model reliably large-scale structure observables such as the correlation function and the power spectrum. Cosmological N-body simulations provide a reference through which we can test our models, but their output suffers from sample variance on large scales. Fortunately, this is the regime where accurate analytic approximations exist. To reduce the variance, which is key to making optimal use of these simulations, we can leverage the accuracy and precision of such analytic descriptions using Control Variates (CV). The power of control variates stems from utilizing inexpensive but highly correlated surrogates of the statistics one wishes to measure. The stronger the correlation between the surrogate and the statistic of interest, the larger the variance reduction delivered by the method. We apply two control variate formulations to mock catalogs generated in anticipation of upcoming data from the Dark Energy Spectroscopic Instrument (DESI) to test the robustness of its analysis pipeline. Our CV-reduced measurements offer a factor of 5-10 improvement in the measurement error compared with the raw measurements. We explore the relevant properties of the galaxy samples that dictate this reduction and comment on the improvements we find on some of the derived quantities relevant to Baryon Acoustic Oscillation (BAO) analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and Performance Analysis of a Highly Efficient Polychromatic Full Stokes Polarization Modulator for the CRISP Imaging Spectrometer

We present the design and performance of a polychromatic polarization modulator for the CRisp Imaging SpectroPolarimeter (CRISP) Fabry–Perot tunable narrow-band imaging spectropolarimer at the Swedish 1 m Solar Telescope (SST). We discuss the design process in depth, compare two possible modulator designs through a tolerance analysis, and investigate thermal sensitivity of the selected design. The trade-offs and procedures described in this paper are generally applicable in the development of broadband polarization modulators. The modulator was built and has been operational since 2015. Its measured performance is close to optimal between 500 and 900 nm, and differences between the design and as-built modulator are largely understood. We show some example data, and briefly review scientific work that used data from SST/CRISP and this modulator.

42 ENGINEERING↗

Measurement of the liquid argon scintillation pulse shape using differentiable simulation in the coherent CAPTAIN-Mills experiment

The coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and beyond Standard Model physics signatures. Two hundred eight-inch photomultiplier tubes instrument the seven-ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM’s light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with 𝒪⁡(1) parts per million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte Carlo simulation and detailed photomultiplier tube response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

Cherenkov detectors↗

On-Chip Batteries as Distributed Energy Sources in Heterogeneous 2.5D/3D Integrated Circuits

Energy efficiency in digital systems faces challenges due to the constraints imposed by small-scale transistors. Moreover, the growing demand for portable consumer electronics necessitates the use of compact energy sources. To address these challenges, heterogeneous 3D IC technology has emerged as a promising solution for the former. Regarding the latter, we propose the concept of distributed batteries within a heterogeneous 3D IC. This approach involves utilizing multiple smaller batteries with different specifications among different modules of 3D ICs. This approach optimizes performance and overcomes limitations associated with both 3D ICs and conventional power delivery methods. Distributed batteries play a vital role in effectively managing the heat generated by energy sources and modules within a 3D IC. Furthermore, they contribute to achieving a uniform distribution of heat throughout the entire structure, which ultimately ensures the optimal performance of the batteries and modules. The simulation results indicate a 40 percent enhancement in achieving a more even distribution of generated heat. Additionally, the proposed distributed battery techniques improve power delivery, enhance reliability, and enable optimized voltage regulation while improving efficiency. In addition to the primary benefits, alternative configurations of the proposed approach can offer extra energy storage capacity and act as efficient electromagnetic shields, resulting in an impressive reduction of external electromagnetic noises by 60 dB.

47 OTHER INSTRUMENTATION↗

TRINIDI: Time-of-Flight Resonance Imaging With Neutrons for Isotopic Density Inference

Accurate reconstruction of 2D and 3D isotope densities is a desired capability with great potential impact in applications such as evaluation and development of next-generation nuclear fuels. Neutron time-of-flight (TOF) resonance imaging offers a potential approach by exploiting the characteristic neutron absorption spectra of each isotope. However, it is a major challenge to compute quantitatively accurate images due to a variety of confounding effects such as severe Poisson noise, background scatter, beam non-uniformity, absorption non-linearity, and extended source pulse duration. We present the TRINIDI algorithm which is based on a two-step process in which we first estimate the neutron flux and background counts, and then reconstruct the areal densities of each isotope and pixel. Both components are based on the inversion of a forward model that accounts for the highly non-linear absorption, energy-dependent emission profile, and Poisson noise, while also modeling the substantial spatio-temporal variation of the background and flux. Further, to do this, we formulate the non-linear inverse problem as two optimization problems that are solved in sequence. We demonstrate on both synthetic and measured data that TRINIDI can reconstruct quantitatively accurate 2D views of isotopic areal density that can then be reconstructed into quantitatively accurate 3D volumes of isotopic volumetric density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Impact of Nonzenith Elevation Angles on Ground-Based Infrared Thermodynamic Retrievals

Observing thermodynamic profiles within the planetary boundary layer is essential to understanding and predicting atmospheric phenomena because of the significant exchange of sensible and latent heat between the land and atmosphere within that layer. The Atmospheric Emitted Radiance Interferometer (AERI) is a ground-based infrared spectrometer used to obtain the vertical profiles of temperature and water vapor mixing ratio. Most AERIs are only capable of zenith views, although the Marine AERI (M-AERI) has a design that allows it to view various elevation angles. In this study, we quantify the improvement in the information content and accuracy of the retrieved profiles when nonzenith angles are included, as is common with microwave radiometer profilers. The impacts of the additional scan angles are quantified through both a synthetic study and with M-AERI observations from the ARM Cloud Aerosol Precipitation Experiment (ACAPEX) campaign. Furthermore, the simulation study shows that low elevation angles contain more information content for temperature whereas high elevation angles have more information content for water vapor. Outside of very humid environments, the addition of low elevation angles also results in lower root-mean-square errors when compared with high angles for both temperature and water vapor mixing ratio, although this is primarily a result of averaging multiple observations together to reduce instrument noise. Real-world results from the ACAPEX dataset indicate similar results as were found for the simulation study, although not all predicted benefits are realized because of the small sample size and observational uncertainties.

54 ENVIRONMENTAL SCIENCES↗

CONFIDANTE Demonstration Prototype Report

This report summarizes design optimization and performance evaluation studies for a new prototype CONFIDANTE (CONfirmation using a Fast-neutron Imaging Detector with Anti-image Null-positive Time Encoding) warhead confirmation system. It was found that a spherical mask geometry and a 2” diameter cylindrical central detector is expected to best discriminate between the parametrically varied source distributions that were evaluated. The optimized design as fabricated and its performance was evaluated in a series of laboratory measurements. The performance was in good agreement with the design studies, with demonstrated discrimination between objects with differences in scale on the order of 5 centimeters or better at 1 meter stand-off

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗