Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FINGERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

The Dynamics of Miscible Fluids: A Space Flight Experiment (MIDAS)

We propose a space flight experiment to study the dynamics of miscible interfaces. A less viscous fluid displaces one of higher viscosity within a tube. The two fluids are miscible in all proportions. An intruding "finger" forms that occupies a fraction of the tube. As time progresses diffusion at the interface combined with flow induced straining between the two fluids modifies the concentration and velocity distributions within the whole tube. Also, under such circumstances it has been proposed that the interfacial stresses could depend on the local concentration gradients (Korteweg stresses) and that the divergence of the velocity need not be zero, even though the flow is incompressible. We have obtained reasonable agreement for the tip velocity between numerical simulations (that ignored the Korteweg stress and divergence effects) and physical experiments only at high Peelet Numbers. However at moderate to low Pe agreement was poor. As one possibility we attributed this lack of agreement to the disregard of these effects. We propose a space experiment to measure the finger shape, tip velocity, and the velocity and concentration fields. From intercomparisons between the experiment and the calculations we can then extract values for the coefficients of the Korteweg stress terms and confirm or deny the importance of these stresses.

Maxworthy, T.↗

Gloved Human-Machine Interface

Certain exemplary embodiments can provide a system, machine, device, manufacture, circuit, composition of matter, and/or user interface adapted for and/or resulting from, and/or a method and/or machine-readable medium comprising machine-implementable instructions for, activities that can comprise and/or relate to: tracking movement of a gloved hand of a human; interpreting a gloved finger movement of the human; and/or in response to interpreting the gloved finger movement, providing feedback to the human.

Adams, Richard↗

Grasp Assist Device with Shared Tendon Actuator Assembly

A grasp assist device includes a glove with first and second tendon-driven fingers, a tendon, and a sleeve with a shared tendon actuator assembly. Tendon ends are connected to the respective first and second fingers. The actuator assembly includes a drive assembly having a drive axis and a tendon hook. The tendon hook, which defines an arcuate surface slot, is linearly translatable along the drive axis via the drive assembly, e.g., a servo motor thereof. The flexible tendon is routed through the surface slot such that the surface slot divides the flexible tendon into two portions each terminating in a respective one of the first and second ends. The drive assembly may include a ball screw and nut. An end cap of the actuator assembly may define two channels through which the respective tendon portions pass. The servo motor may be positioned off-axis with respect to the drive axis.

Ihrke, Chris A.↗

Tactile Data Entry System

The patent-pending Glove-Enabled Computer Operations (GECO) design leverages extravehicular activity (EVA) glove design features as platforms for instrumentation and tactile feedback, enabling the gloves to function as human-computer interface devices. Flexible sensors in each finger enable control inputs that can be mapped to any number of functions (e.g., a mouse click, a keyboard strike, or a button press). Tracking of hand motion is interpreted alternatively as movement of a mouse (change in cursor position on a graphical user interface) or a change in hand position on a virtual keyboard. Programmable vibro-tactile actuators aligned with each finger enrich the interface by creating the haptic sensations associated with control inputs, such as recoil of a button press.

Adams, Richard J.↗

Cloudless Atmospheres for Young Low-Gravity Substellar Objects

Atmospheric modeling of low-gravity (VL-G) young brown dwarfs remains challenging. The presence of very thick clouds is a possible source of this challenge, because of their extremely red near-infrared (NIR) spectra, but no cloud models provide a good fit to the data with a radius compatible with the evolutionary models for these objects. We show that cloudless atmospheres assuming a temperature gradient reduction caused by fingering convection provide a very good model to match the observed VL-G NIR spectra. The sequence of extremely red colors in the NIR for atmospheres with effective temperatures from approx. 2000 K down to approx. 1200 K is very well reproduced with predicted radii typical of young low-gravity objects. Future observations with NIRSPEC and MIRI on the James Webb Space Telescope (JWST) will provide more constraints in the mid-infrared, helping to confirm or refute whether or not the NIR reddening is caused by fingering convection. We suggest that the presence or absence of clouds will be directly determined by the silicate absorption features that can be observed with MIRI. JWST will therefore be able to better characterize the atmosphere of these hot young brown dwarfs and their low-gravity exoplanet analogs.

Tremblin, P.↗

Biblade Sampler

A BiBlade sampler may include a first blade and a second blade in a retracted position. The BiBlade sampler may also include a gripper, which is driven by an actuator. The gripper may include a plurality of fingers to force the first blade and the second blade to remain in a retracted position. When the fingers are unhooked, the first blade and the second blade penetrate a surface of an object.

Backes, Paul G.↗

Fast, Large Area, Wide Band GAP UV Photodetector for Cherenkov Light Detection

A solid-state radiation detector includes a pattern of conductive metal on a zinc oxide substrate. The pattern provides an arrangement of interdigitated electrode fingers. The wide band gap substrate is sensitive to UV light, which can cause a conductivity change in the substrate. The electrode fingers are configured to sense a difference in substrate conductivity resulting from UV light. The detector has a fast response time, which enables it to detect Cherenkov light. The compact detector provides savings on size, weight, and required power. Thus, the solid-state detector can be used to replace photomultiplier tubes in Cherenkov detectors. The features of the novel detector allow for an improved system to detect and monitor UV radiation, especially during deep space missions.

Wrbanek, John D.↗

Cloudless Atmospheres for Young Low-Gravity Substellar Objects

Atmospheric modeling of low-gravity (VL-G) young brown dwarfs remains challenging. The presence of very thick clouds is a possible source of this challenge, because of their extremely red near-infrared (NIR) spectra, but no cloud models provide a good fit to the data with a radius compatible with the evolutionary models for these objects. We show that cloudless atmospheres assuming a temperature gradient reduction caused by fingering convection provide a very good model to match the observed VL-G NIR spectra. The sequence of extremely red colors in the NIR for atmospheres with effective temperatures from ∼2000 K down to ∼1200 K is very well reproduced with predicted radii typical of young low-gravity objects. Future observations with NIRSPEC and MIRI on the James Webb Space Telescope (JWST) will provide more constraints in the mid-infrared, helping to confirm or refute whether or not the NIR reddening is caused by fingering convection. We suggest that the presence or absence of clouds will be directly determined by the silicate absorption features that can be observed with MIRI. JWST will therefore be able to better characterize the atmosphere of these hot young brown dwarfs and their low-gravity exoplanet analogs.

Tremblin, P.↗

The Fine Motor Skills and Cognition Test Batteries: Normative Data and Interdependencies

Fine motor skills and cognitive abilities are major contributors to crew performance on essentially all extravehicular and intra-vehicular activities during spaceflight. It is critical for the crew’s safety, and for mission productivity, to know if, and when, motor skills or cognitive abilities are compromised so that countermeasures may be introduced. NASA has developed two test batteries to measure and monitor astronaut cognitive and fine motor skills. The Cognition Test Battery contains 10 sub-tests that assess cognitive behaviors ranging from low level visual perception to high level decision-making. The Fine Motor Skills Test Battery contains 4 sub-tests that assess finger dexterity, manual dexterity and wrist-finger speed. This study sought to determine acceptable norms for both batteries in an astronaut-like population and to identify the extent to which fine motor skills contribute to cognitive test scores.

Normative Data↗

Results of the Field Test and Defining Sensormotor Fitness for Duty Standards

The primary goals of the Field Test were (1) to determine functional abilities associated with long-duration space flight crews beginning as soon after landing as possible (< 2 hours), and (2) to characterize the time course of recovery with additional follow-up measurement sessions within 24 hours after landing. The NASA and Russian teams have collected data on a total of 39 different United States Orbital Segment (USOS) and Russian crewmembers, with 9 Russian crewmembers being tested twice (total of 48 tests). Eighteen subjects (7 Russian, 11 USOS) completed a reduced Field Test (pilot) protocol and 30 subjects (19 Russian and 11 USOS) participated in the full Field Test. This presentation will focus on a subset of the measures that will be used in the upcoming ground study to determine sensorimotor fitness for duty standards, namely: tandem walk, obstacle walk, eye-hand coordination task, finger-to-nose task, and Computerized Dynamic Posturography (CDP). Exploration-class missions including Artemis, Gateway, and beyond will require a new level of autonomy around periods of gravitational transition, where sensorimotor disturbances increase. The operational support that is available upon return to Earth including rescue teams, medical interventions, and the ability to rest as needed will not be available after landing on the lunar or Martian surface. Because of this, there is a need to define fitness for duty standards that will help inform crew capabilities during and soon after gravitational transitions. Due to the new requirements of the exploration environment, we must utilize a set of exploration field measures, for which no previous spaceflight data exists to define fitness for duty standards. A Sensorimotor Adaptation Analog (SAA) that can provide different levels of acute disorientation through combined vestibular, visual, and proprioceptive disruptions will be used to increase the range of performance in exploration field measures, simulating the moderate-to-severe performance decrements observed in spaceflight. The levels of SAA will be titrated and validated by comparison to gold standard measures that have a wealth of spaceflight data at different time points during recovery. These data will be pulled directly from the results of Field Test and help ensure the range of performance while being exposed to SAA mimics the range of performance from pre-flight to immediately postflight in Field Test subjects. Specifically, we will be using the tandem walk, obstacle walk, eye-hand coordination task, finger-to-nose task, and CDP as the gold standard measures. Referencing this Field Test data in the form of gold standard measures will also help us characterize and contextualize how each magnitude of SAA disorientation compares to recovery from long-term microgravity exposure.

M J F Rosenberg↗

Learning-Based State-Dependent Coefficient Form Task Space Tracking Control of Soft Robot

n this paper, a data-driven modeling and control framework is developed for task space control of a soft robot gripper which consists of four individual soft fingers. Each of the four fingers is modeled as a manipulator with high degrees of freedom. The corresponding task space dynamics of the manipulator are derived using a rigid-link approximation of the continuum manipulator. A neural network approach is used to learn the derived dynamics in State Dependent Coefficient (SDC) form. Using the learned SDC matrices, an asymptotically stable optimal closed-loop tracking controller which is based on solving the State Dependent Riccati Equation (SDRE) is derived. The model learning and trajectory tracking controller is implemented on an open source Soft Motion (SoMo) platform simulating the soft gripper motion and corresponding tracking results are presented.

Rounak Bhattacharya↗

SoMo: Fast and Accurate Simulations of Continuum Robots in Complex Environments

Engineers and scientists often rely on their intuition and experience when designing soft robotic systems. The development of performant controllers and motion plans for these systems commonly requires time-consuming iterations on hardware. We present the SoMo (Soft Motion) toolkit, a software framework that makes it easy to instantiate and control typical continuum manipulators in an accurate physics simulator. SoMo introduces a standardized and human-readable description format for continuum manipulators. It leverages this description format and the Bullet physics engine to enable fast and accurate simulations of soft and soft-rigid hybrid robots in environments with complex contact interactions. This allows users to vary design and control parameters across simulations with minimal effort. We compare the capabilities of SoMo to other physics simulators and highlight the benefits and accuracy of SoMo by demonstrating the agreement between simulation and real-world experiments on several examples; these include an in-hand manipulation task with continuum fingers, an automated exploration of how to design soft fingers for precision grasping, and a brief snake locomotion study. Overall, SoMo provides an accessible way for designers of soft robotic hardware and control systems to gain access to a simulation-accelerated workflow.

Moritz A. Graule↗

Controlled zone microwave plasma system

An apparatus and method for initiating a process gas plasma. A conductive plate having a plurality of conductive fingers is positioned in a microwave applicator. An arc forms between the conductive fingers to initiate the formation of a plasma. A transport mechanism may convey process materials through the plasma. A spray port may be provided to expel processed materials.

47 OTHER INSTRUMENTATION↗

Planar controlled zone microwave plasma system

An apparatus and method for initiating a process gas plasma. A conductive plate having a plurality of conductive fingers is positioned in a microwave applicator. An arc forms between the conductive fingers to initiate the formation of a plasma. A transport mechanism may convey process materials through the plasma. A spray port may be provided to expel processed materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

User interface for a tele-operated robotic hand system

Disclosed here is a user interface for a robotic hand. The user interface anchors a user's palm in a relatively stationary position and determines various angles of interest necessary for a user's finger to achieve a specific fingertip location. The user interface additionally conducts a calibration procedure to determine the user's applicable physiological dimensions. The user interface uses the applicable physiological dimensions and the specific fingertip location, and treats the user's finger as a two link three degree-of-freedom serial linkage in order to determine the angles of interest. The user interface communicates the angles of interest to a gripping-type end effector which closely mimics the range of motion and proportions of a human hand. The user interface requires minimal contact with the operator and provides distinct advantages in terms of available dexterity, work space flexibility, and adaptability to different users.

42 ENGINEERING↗

Focusing transformers/filters in isotropic/anisotropic piezoelectrics

A focusing interdigital transducer (IDT) and corresponding single- and dual-port piezoelectric devices are disclosed. The focusing interdigital transducer, which generates Lamé acoustic waves, permits operation at significantly higher frequencies than those possible with traditional IDTs. The focusing IDT employs multiple arced fingers formed both above and below the piezoelectric layer to improve coupling efficiency by coupling through both the e31 and e33 piezoelectric coefficients to the piezoelectric layer. By optimizing both anchor design and location, acoustic wave losses are minimized, thereby improving the device's quality factor Q. Through proper bus design and selection of the number of IDT fingers, a device's impedance can be tuned for a given application. The focusing IDTs may be used in single-port filter devices and dual-port transformer devices. The single- and dual-port devices may operate at a single frequency, at two frequencies, or over a band of frequencies.

Siddiqui, Aleem↗

Ceramic matrix composite turbine nozzle shell and method of assembly

A method of manufacturing a ceramic matrix composite (CMC) turbine nozzle shell is provided. The method includes: assembling a primary outer nozzle platform, a primary inner nozzle platform, a core and trailing edge preform, and an airfoil-shaped body; joining the primary outer nozzle platform to a secondary outer nozzle platform of the airfoil-shaped body; and joining the primary inner nozzle platform to a secondary inner nozzle platform of the airfoil-shaped body. Composite plies circumferentially surround the airfoil-shaped body, and their longitudinal edges are cut into fingers that are folded down. The fingers are interleaved between secondary platform plies to form the secondary outer and inner nozzle platforms.

de Diego, Peter↗

History Matching and Prediction of a Polymer Flood Pilot in Heavy Oil Reservoir on Alaska North Slope

The first-ever polymer flood pilot to enhance heavy oil recovery on Alaska North Slope is ongoing. After more than 3 years of polymer injection, significant benefit has been observed from the decrease in water cut from 65% to less than 15% in the project producers. The primary objective of this study is to develop a robust history-matched reservoir simulation model capable of predicting future polymer flood performance. In this work, the reservoir simulation model has been developed based on the geological model and available reservoir and fluid data. In particular, four high transmissibility strips were introduced to connect the injector-producer well pairs, simulating short-circuiting flow behavior that can be explained by viscous fingering and reproducing the water cut history. The strip transmissibilities were manually tuned to improve the history matching results during the waterflooding and polymer flooding periods, respectively. It has been found that higher strip transmissibilities match the sharp water cut increase very well in the waterflooding period. Then the strip transmissibilities need to be reduced with time to match the significant water cut reduction. The viscous fingering effect in the reservoir during waterflooding and the restoration of injection conformance during polymer flooding have been effectively represented. Based on the validated simulation model, numerical simulation tests have been conducted to investigate the oil recovery performance under different development strategies, with consideration for sensitivity to polymer parameter uncertainties. The oil recovery factor with polymer flooding can reach about 39% in 30 years, twice as much as forecasted with continued waterflooding. Besides, the updated reservoir model has been successfully employed to forecast polymer utilization, a valuable parameter to evaluate the pilot test’s economic efficiency. All the investigated development strategies indicate polymer utilization lower than 3.5 lbs/bbl in 30 years, which is less than that of the same polymer used in a polymer pilot in Argentina.

Wang, Xindan↗