Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Current distribution monitoring enables quench and damage detection in superconducting fusion magnets

Abstract Fusion magnets made from high temperature superconducting ReBCO CORC ® cables are typically protected with quench detection systems that use voltage or temperature measurements to trigger current extraction processes. Although small coils with low inductances have been demonstrated, magnet protection remains a challenge and magnets are typically operated with little knowledge of the intrinsic performance parameters. We propose a protection framework based on current distribution monitoring in fusion cables with limited inter-cable current sharing. By employing inverse Biot-Savart techniques to distributed Hall probe arrays around CORC ® Cable-In-Conduit-Conductor (CICC) terminations, individual cable currents are recreated and used to extract the parameters of a predictive model. These parameters are shown to be of value for detecting conductor damage and defining safe magnet operating limits. The trained model is then used to predict cable current distributions in real-time, and departures between predictions and inverse Biot-Savart recreated current distributions are used to generate quench triggers. The methodology shows promise for quality control, operational planning and real-time quench detection in bundled CORC ® cables for compact fusion reactors.

47 OTHER INSTRUMENTATION↗

The inductively driven transmission line: A passively coupled device for diagnostic applications on the Z pulsed power facility

The inductively driven transmission line (IDTL) is a miniature current-carrying device that passively couples to fringe magnetic fields in the final power feed on the Z Pulsed Power Facility. The IDTL redirects a small amount of Z’s magnetic energy along a secondary path to ground, thereby enabling pulsed power diagnostics to be driven in parallel with the primary load for the first time. IDTL experiments and modeling presented here indicate that IDTLs operate non-perturbatively on Z and that they can draw in excess of 150 kA of secondary current, which is enough to drive an X-pinch backlighter. Further experiments show that IDTLs are also capable of making cleaner, higher-fidelity measurements of the current flowing in the final feed.

47 OTHER INSTRUMENTATION↗

Measurement of 𝜋 0 production in $\bar{v}_μ$ charged-current interactions in the NOvA near detector

We present a high-statistics measurement of muon antineutrino-induced charged-current neutral pion production on a hydrocarbon target using the NOvA near detector. The differential cross sections as functions of the momenta and angles of the outgoing pion and muon, the squared four-momentum transfer, and the invariant mass of the hadronic system at an average neutrino energy of 2 GeV are measured and compared with predictions from various neutrino interaction models. The results agree with the GENIE prediction but suggest that other models underestimate the cross section in the Δ⁡(1232) resonance region. These results represent the most precise measurement of antineutrino-induced neutral pion production to date.

neutrino detection↗

Persistent Current Simulation for CCT Testing Magnet Used in EIC

The Electron-Ion Collider (EIC), a powerful new facility to be built in the United States at the U.S. Department of Energy's Brookhaven National Laboratory in collaboration with Thomas Jefferson National Accelerator Facility, will explore the most fundamental building blocks of nearly all visible matter. Here, there are many different types of superconducting magnets near the interaction region (IR) of EIC. Due to space constraints and special lattice requirements, Tapered CCT (canted-cosine theta) magnets have been used for EIC. At beam injection, the magnetic field is only ~5.5% of the maximum operating field. Considerable field errors will be generated from persistent current in superconducting strands even using very fine filament for those superconductors. A tapered CCT demonstrator magnet has been built and tested successfully at BNL since July 2020 to evaluate the key technologies for future tapered CCT magnets. In October 2023, BNL team also measured the persistent current in this demonstrator magnet. To validate the persistent current simulation methods for CCT magnets in EIC, this paper used a full 3D Opera Model and measured magnetization data from superconducting strand for the simulation. Simulation results showed reasonable agreement with recent measurement results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Kinetic equilibrium reconstructions of plasmas in the MAST database and preparation for reconstruction of the first plasmas in MAST upgrade

Reconstructions of plasma equilibria using magnetic sensors were routine during operation of the Mega Ampere Spherical Tokamak (MAST) device, but reconstructions using kinetic profiles were not. These are necessary for stability and disruption analysis of the MAST database, as well as for operation in the upgrade to the device, MAST-U. The three-dimensional (3D) code VALEN is used to determine eddy currents in the 3D vessel structures for vacuum coil test shots, which are then mapped to effective resistances in the two-dimensional vessel groupings in the EFIT equilibrium reconstruction code to be used in conjunction with nearby loop voltage measurements for estimated currents in the structures during reconstruction. Kinetic equilibrium reconstructions with EFIT, using all available magnetic sensors as well as Thomson scattering measurements of electron temperature and density, charge exchange recombination spectroscopy measurements of ion temperature, and internal magnetic field pitch angle measurements from a motional Stark effect (MSE) diagnostic are performed for a large database of MAST discharges. Excellent convergence errors are obtained for the portions of the discharges where the stored energy was not too low, and it is found that reconstructions performed with temperature and density measurements but without MSE data usually already match the pitch angle measurements well. A database of 275 kinetic equilibria is used to test the ideal MHD stability calculation capability for MAST. In conclusion, the necessary changes to conducting structure in VALEN, and diagnostic setup in EFIT have been completed for the upgrade from MAST to MAST-U, enabling kinetic reconstructions to commence from the first plasma discharges of the upgraded device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current-based metrology with two-terminal mesoscopic conductors

The traditional approach to quantum parameter estimation focuses on the quantum state, deriving fundamental bounds on precision through the quantum Fisher information. In most experimental settings, however, performing arbitrary quantum measurements is highly unfeasible. In open quantum systems, an alternative approach to metrology involves the measurement of stochastic currents flowing from the system to its environment. However, the present understanding of current-based metrology is mostly limited to Markovian master equations. Considering a parameter estimation problem in a two-terminal mesoscopic conductor, we identify the key elements that determine estimation precision within the Landauer-Büttiker formalism. Crucially, this approach allows us to address arbitrary coupling and temperature regimes. Furthermore, we obtain analytical results for the precision in linear-response and zero-temperature regimes. For the specific parameter estimation task that we consider, we demonstrate that the boxcar transmission function is optimal for current-based metrology in all parameter regimes.

Landauer formula↗

First Measurement of $\Lambda$ Electroproduction off Nuclei in the Current and Target Fragmentation Regions

We report results of $\Lambda$ hyperon production in semi-inclusive deep-inelastic scattering off deuterium, carbon, iron, and lead targets obtained with the CLAS detector and the CEBAF 5.014 GeV electron beam. These results represent the first measurements of the $\Lambda$ multiplicity ratio and transverse momentum broadening as a function of the energy fraction ($z$) in the current and target fragmentation regions. The multiplicity ratio exhibits a strong suppression at high $z$ and an enhancement at low $z$. The measured transverse momentum broadening is an order of magnitude greater than that seen for light mesons. This indicates that the propagating entity interacts very strongly with the nuclear medium, which suggests that propagation of di-quark configurations in the nuclear medium takes place at least part of the time, even at high $z$. The trends of these results are qualitatively described by the GiBUU transport model, particularly for the multiplicity ratios. These observations will potentially open a new era of studies of the structure of the nucleon as well as of strange baryons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Power And Current Bounds For Two Similar Loads

We examine the question of how to obtain bounding power (or current) for two similar loads with an unknown source circuit, but measurements of power (or current) for one load as well as models and measurements of both load impedances.

42 ENGINEERING↗

Fine structure of current noise spectra in nanoelectromechanical resonators

Here, we study the frequency-dependent noise of a suspended carbon nanotube quantum dot nanoelectromechanical resonator induced by electron-vibration coupling. Using a rigorous Keldysh diagrammatic technique, we establish a formal framework connecting the vibrational properties to electrical measurements. We find that the noise power spectrum exhibits a narrow resonant peak at the frequency of the vibrational modes. However, this fine structure tends to disappear due to a coherent cancellation effect when the tunneling barriers are tuned to a symmetric point. Notably, measuring the electrical current noise spectra provides a sensitive alternative method for detecting the damping and dephasing of quantum vibrational modes.

Electric measurements↗

Contrast Mechanisms in Secondary Electron e-Beam-Induced Current (SEEBIC) Imaging

Abstract Over the last few years, a new mode for imaging in the scanning transmission electron microscope (STEM) has gained attention as it permits the direct visualization of sample conductivity and electrical connectivity. When the electron beam (e-beam) is focused on the sample in the STEM, secondary electrons (SEs) are generated. If the sample is conductive and electrically connected to an amplifier, the SE current can be measured as a function of the e-beam position. This scenario is similar to the better-known scanning electron microscopy-based technique, electron beam-induced current imaging, except that the signal in the STEM is generated by the emission of SEs, hence the name secondary electron e-beam-induced current (SEEBIC), and in this case, the current flows in the opposite direction. Here, we provide a brief review of recent work in this area, examine the various contrast generation mechanisms associated with SEEBIC, and illustrate its use for the characterization of graphene nanoribbon devices.

47 OTHER INSTRUMENTATION↗

Optimization-Based Data-Driven Approach for Detecting Fault Location in Power Systems

In grids with large penetration of converterinterfaced resources (CIRs), measurements of voltage, current, and line parameters can fluctuate significantly during fault conditions. These fluctuations, combined with complex network topologies and extensive system branching, make accurate fault location challenging. Faults, such as short circuits, can cause prolonged outages with serious socio-economic impacts, highlighting the need for rapid fault identification to minimize downtime. However, current fault detection methods—such as relays and digital fault recorders—often relay information too slowly, impeding swift corrective action. Given the limited availability of high-resolution phasor measurement units, this paper introduces an optimization-based observer to estimate fault locations, grid line parameters, and voltages using local CIR measurements. To preserve the confidentiality of CIRs and enhance estimation accuracy, this study uses a black-box model of CIRs. This bottom-up, event-driven approach can enhances protection and control systems through optimized and real-time fault detection. Simulation results show that the optimization-based data-driven observer can accurately detect fault locations and estimate grid states and parameters, providing valuable insights for utilities and operators in grid applications.

Subedi, Sunil [ORNL] (ORCID:000000034069090X)↗

Measured Thermal and Fast Neutrons Fluence Rates for ATF-1 Holders During ATR Cycle 166B

This report contains the thermal (2200 m/s) and fast (E>lMeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 166B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. All "BR" holder monitor wires for this cycle are 56.375 inches long. This length allows measurements from 31.17 inches above core midplane to 19.81 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle. The monitors were located in an outward small I-holes,1-22 and 1-23. Thermal neutron fluence was determined based on the activation of the CoAl wires and resonance corrections determined in the irradiation of Cycle 152A when the RML measured cadmium-covered as well as bare neutron monitors in the Southwest, Southeast, and H positions at the Center lobe to determine the division in neutron energy between epithermal and thermal neutrons. For more information please refer to letter “Radiation Measurements Laboratory measurements of in core ATR physics testing during cycle 152A. The measured values documented in RML procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values. Fast neutron fluence was determined using the activation of nickel wires. Typically, a fission spectrum averaged cross section (E>1 MeV) is used as determined in detailed measurements described in “ATR Neutron Spectral Characterization,” which gives an effective cross section of 97 mb for the small I-holes. However, those measurements were performed with unfueled experiments. The fast fluence values reported here use a perturbed 114 mb effective>1 MeV spectrum averaged cross section for the small I-holes based on MCNP simulations for a previous fueled experiment in the1-24 position. Refer to “LWR- ATR Irradiation Measured Thermal and Fast Neutron Fluence Rates ATR CYCLE 133A 04/19/04 thru 05/17/04” for more information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hot-Carrier Injection and Millisecond Charge Separation from a Robust Heteroleptic Iron(II) Chromophore Immobilized on TiO 2

The synthesis, spectroscopic characterization, computational analysis, and photoelectrochemical behavior of a new iron-based chromophore, [(Cpy) 2 Fe- (deeb)](PF 6 ) 2 (Fe(Cpy) 2 (deeb)), where Cpy is 1-methyl-3-(2-pyridyl)imidazole and deeb is 4,4’-(CO 2 CH 2 CH 3 ) 2 -2,2’-bipyridine, is reported. Electrochemically reversible waves assigned to a metal-centered E o (Fe III/II ) = +0.48 and a ligand-centered E o (Fe 2+/+ ) = −1.47 V vs Fc +/0 reduction were evident in cyclic voltammetry measurements. The combination of a strong σ-donor and a π-acceptor lowered the energy of the metal-toligand charge-transfer (MLCT) excited state relative to the metal-centered state. Two MLCT transitions appear in the visible region at 424 and 580 nm. TDDFT calculations revealed that the lower-energy band was well formulated as Fe(II)→deeb, and the higher-energy transition was charge transfer to both the deeb and Cpy ligands. Resonance Raman spectroscopy supports these findings showing enhanced deeb vibrational modes with 532 nm excitation, both deeb and Cpy modes with 473 nm excitation, and exclusively Cpy with 405 nm excitation. Ultrafast spectroscopy reveals a short-lived (∼2 ps) MLCT excited state and a longer-lived (∼20 ps) metal-centered state. Efficient methods to deprotect the ester groups and anchor the complex to mesoporous TiO 2 (anatase) thin films in high surface coverages, Fe(Cpy) 2 (dcb)|TiO 2 σ = 3 × 10 −8 mol/cm 2 , were established. Pulsed light excitation of Fe(Cpy) 2 (dcb)|TiO 2 resulted in rapid excited state injection (k inj > 10 8 s −1 ) and formation of a charge-separated state, Fe III (Cpy) 2 (dcb)|TiO 2 (e), which persists on the millisecond time scale before returning cleanly to the ground state with secondorder kinetics. Injection yields measured 50 ns after light excitation were found to double from Φ = 0.15 with green (532 nm) light to 0.30 with blue (457 nm) light excitation. Incident photon-to-current efficiency (% IPCE) measurements as a function of excitation wavelength in a 0.5 M LiI/I 2 /CH 3 CN electrolyte provide clear evidence for band-selective “hot carrier” injection from the remote Cpy-localized excited state. Collectively, the spectroscopic and photoelectrochemical data indicate that a semiconductor can intercept hot electrons from iron chromophores even when the excited-state dipole is oriented away from the surface-anchoring ligand.

Charge transfer↗

Electronic 1/f noise as a probe of dimensional effects on spin-glass dynamics

Over the past decade, spin-glass simulations have improved to the point that they now access time- and length-scales comparable to experiments at the mesoscale. A recent series of thin-film field-cooled/zero-field-cooled magnetization (FC/ZFC) experiments demonstrated activated spin dynamics, with a temperature-independent activation energy proportional to the logarithm of the film thickness and with coefficients in remarkable agreement with the simulation. These measurements require the application of small magnetic fields, which has been shown to affect the spin-glass energy landscape. Measurements of the 1/f noise in metallic spin-glasses have been previously shown to be a sensitive probe of the spin dynamics, and the measurements can be made without applying a magnetic field. In this mini-review, we review these techniques and discuss how transport measurements can fit into the current landscape of spin-glass measurements. We compare previous measurements to more recent measurements on similar films, made with ostensibly different cooling protocols, and compare both the previous and recent measurements to the magnetometry. The transport measurements—taken over a wider range of temperature than magnetometry—suggest that the maximum spin-glass energy barrier height is temperature-dependent, not fixed, possibly due to two-dimensional dynamics. We discuss this possibility, along with future measurements, which may be able to resolve this mystery.

1/f noise↗

Nuclear Dependence of Charged Current Inclusive $\bar{\nu}_\mu -$A Cross Section Measurements at 6 GeV at MINERvA

The main advantage of the MINERvA detector is that it uses differently sized nuclear targets, in the same neutrino beam, allowing for a direct study of nuclear medium effects, with reduced flux and detector uncertainties. This thesis presents the first high statistics charged current antineutrino-nucleus inclusive two-dimensional cross section measurements using an antineutrino beam with $\langle E_{\bar\nu}\rangle\sim$ 6 GeV, on iron, lead, carbon and hydrocarbon targets, as a function of bjorken $x$ and four-momentum transfer squared $Q^2$, invariant mass $W$ and $Q^2$ and muon longitudinal and transverse momenta, $p_t$ and $p_z$. These nuclei of different sizes were utilized to measure the nuclear dependence of the cross section. The antineutrino interactions that were utilized for the analysis presented in this thesis, were having an antimuon in the final state with energy 2-20GeV and with an antimuon scattering angle less than $17^o$. This analysis represents one of the largest antineutrino datasets analyzed to date in the energy region of $\langle E_{\bar\nu} \rangle \sim$ 6 GeV. This direct evidence for the nuclear medium effects, can help benchmarking models, which can be used by future neutrino experiments like DUNE, by extrapolating these results to Argon target.

Gaur, Prameet Kumar↗

Improved Limit on Tensor Currents in the Weak Interaction from Li 8 β Decay

Here, the electroweak interaction in the standard model is described by a pure vector-axial-vector structure, though any Lorentz-invariant component could contribute. In this Letter, we present the most precise measurement of tensor currents in the low-energy regime by examining the $β-\bar{ν}$ correlation of trapped 8 Li ions with the Beta-decay Paul Trap. We find $a_{β\barν}$ = - 0.3325 ± 0.0013 stat ± 0.0019 syst at 1σ for the case of coupling to right-handed neutrinos (C T = -C$^{'}_{T}$), which is consistent with the standard model prediction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

How Should Researchers Measure Perovskite-Based Monolithic Multijunction Solar Cells’ Performance? A Calibration Lab's Perspective

Perovskite multijunctions (PVSK MJs) have made remarkable progress with monolithic PVSK/PVSK tandems surpassing the efficiency of single-junction (1 J) PVSK cells and PVSK/Si cells reported to exceed the 30% efficiency mark. These efficiencies are reported at standard test conditions (STC), established by the photovoltaic (PV) community to facilitate comparison between devices and technologies. Herein, it is discussed why an accurate STC performance measurement for a MJ is more complicated than for a 1 J cell and the special aspects to be considered when measuring the current-voltage characteristics and the performance of PVSK-containing MJ cells are emphasized. It is discussed why a spectrally adjustable solar simulator is needed and the sequence of accurate performance measurement, namely measurement of the spectral response of each junction, adjustment of the spectrum, and appropriate protocols for measuring the power output of the device at STC, is presented. For all these, common errors and pitfalls that sometime lead to misleading interpretation of the results are presented, and the methods to evaluate the accuracy of the data when a spectrally adjustable solar simulator is not available are recommended. Finally, first step is taken toward recommending performance measurement approaches when high throughput is required as will eventually be in a production line.

14 SOLAR ENERGY↗