Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Mounting Thin Samples For Electrical Measurements

New method for mounting thin sample for electrical measurements involves use of vacuum chuck to hold a ceramic mounting plate, which holds sample. Contacts on mounting plate establish electrical connection to sample. Used to make electrical measurements over temperature range from 77 to 1,000 K and does not introduce distortions into magnetic field during Hall measurements.

Matus, L. G.↗

Multivariate Methods for Prediction of Geologic Sample Composition with Laser-Induced Breakdown Spectroscopy

Laser-induced breakdown spectroscopy (LIBS) uses pulses of laser light to ablate a material from the surface of a sample and produce an expanding plasma. The optical emission from the plasma produces a spectrum which can be used to classify target materials and estimate their composition. The ChemCam instrument on the Mars Science Laboratory (MSL) mission will use LIBS to rapidly analyze targets remotely, allowing more resource- and time-intensive in-situ analyses to be reserved for targets of particular interest. ChemCam will also be used to analyze samples that are not reachable by the rover's in-situ instruments. Due to these tactical and scientific roles, it is important that ChemCam-derived sample compositions are as accurate as possible. We have compared the results of partial least squares (PLS), multilayer perceptron (MLP) artificial neural networks (ANNs), and cascade correlation (CC) ANNs to determine which technique yields better estimates of quantitative element abundances in rock and mineral samples. The number of hidden nodes in the MLP ANNs was optimized using a genetic algorithm. The influence of two data preprocessing techniques were also investigated: genetic algorithm feature selection and averaging the spectra for each training sample prior to training the PLS and ANN algorithms. We used a ChemCam-like laboratory stand-off LIBS system to collect spectra of 30 pressed powder geostandards and a diverse suite of 196 geologic slab samples of known bulk composition. We tested the performance of PLS and ANNs on a subset of these samples, choosing to focus on silicate rocks and minerals with a loss on ignition of less than 2 percent. This resulted in a set of 22 pressed powder geostandards and 80 geologic samples. Four of the geostandards were used as a validation set and 18 were used as the training set for the algorithms. We found that PLS typically resulted in the lowest average absolute error in its predictions, but that the optimized MLP ANN and the CC ANN often gave results comparable to PLS. Averaging the spectra for each training sample and/or using feature selection to choose a small subset of wavelengths to use for predictions gave mixed results, with degraded performance in some cases and similar or slightly improved performance in other cases. However, training time was significantly reduced for both PLS and ANN methods by implementing feature selection, making this a potentially appealing method for initial, rapid-turn-around analyses necessary for Chemcam's tactical role on MSL. Choice of training samples has a strong influence on the accuracy of predictions. We are currently investigating the use of clustering algorithms (e.g. k-means, neural gas, etc.) to identify training sets that are spectrally similar to the unknown samples that are being predicted, and therefore result in improved predictions

Morris, Richard↗

Open Specy 1.0: Automated (Hyper)spectroscopy for Microplastics

Microplastic spectral analysis is one of the most time-consuming processes in studying microplastic pollution, often requiring days per sample. Researchers are transitioning to automated batch and hyperspectral image analysis techniques to enhance efficiency. Open Specy, initially aimed at manual single-spectrum analysis, has now integrated automated methods. This updated version, Open Specy 1.0, introduces several new features, including two algorithms for automated processing (smoothing and particle compression), an extensive library containing over 40,000 open-source Raman and FTIR spectra, and two machine learning classifiers (logistic regression and k medoids) developed from this library. Furthermore, it includes a revamped user interface, an R package, and a benchmark data set for testing future advancements in automated techniques. Researchers evaluated various configurations for hyperspectral smoothing, particle identification, compression, and splitting, to achieve combined recovery rates between 50 and 150% particle counts, identities, and sizes with a coefficient of variation (CV) of less than 40% (the accredited standard). Mean absorbance times the standard deviation provided a consistent particle identification. Hyperspectral smoothing led to a 96% combined recovery rate and reduced variability (CV = 38%) compared to the 86% recovery (CV = 83%) of nonsmoothed controls. Additionally, compressing spectra for particles was significantly faster (>3x) and showed similar accuracy but with reduced variability than processing each pixel individually. Key challenges persist in automating spectral analysis, particularly in refining particle splitting algorithms, and improving identification routines to minimize false positives and negatives. In conclusion, new methods in sample preparation for better stabilization and dispersion of particles could overcome some of these issues.

13 HYDRO ENERGY↗

WHONDRS Surface Water Dissolved Organic Carbon and FTICR-MS across Stream Orders in Four United States Watersheds in 2019 and 2020 (v3)

This dataset supports the broader Watershed Rules of Life (WROL) study examining spatial and temporal biogeochemical and microbial relationships across the Connecticut River, Deschutes River, Gunnison River, and Willamette River watersheds. The dataset provides geochemistry and organic matter characterization data generated from surface water collected from August 2019 to September 2020 in Colorado, Connecticut, Oregon, and Vermont. Related data were collected and will be published separately in collaboration with P. A. Raymond and B. C. Crump as part of WROL. This dataset is comprised of one folder containing (1) file-level metadata; (2) data dictionary; (3) readme; (4) field metadata; (5) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (6) surface water sampling protocol; (7) methods codes; (8) international generic sample number (IGSN) mapping file; and (9) a folder of high resolution characterization of organic matter via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) generated through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). The FTICR folder contains two subfolders, one containing the .xml data files and the other containing instructions for using Formularity (https://omics.pnl.gov/software/formularity) and an R script to process the data based on the user's specific needs. All files are .csv, .pdf, .R, .ref, or .xml. This data package was originally published in October 2022. It was updated in July 2023 (v2) and again in November 2023 (v3). See the change history section in the readme for more details.

54 ENVIRONMENTAL SCIENCES↗

An etiological study of phthalate self-contamination of spacecraft and contamination from their earthly environs

Phthalates are very objectionable contaminants in space experiments because of their strong absorption in the UV and IR regions of the spectrum. Thus, even minute amounts of these compounds migrating to optical equipment, in test or space flight conditions, can seriously compromise the results of experiments by altering the sensitivity of the functional equipment. Volatility data of the phthalates and other plasticizers are presented in addition to UV spectra of ultrathin films of these same types of compounds. Sources of plasticizer contamination are revealed with special recognition given to di-2-ethylhexyl phthalate (DEHP), the single most ubiquitous plasticizer in use. A surprisingly large percentage of the outgassing condensates from vacuum testing of spacecraft contain DEHP as well as other plasticizers. IR and gas chromatography/mass spectroscopy methods were used to analyze samples from spacecraft. Methods for successful reduction of plasticizers and other contaminants are mentioned.

Gross, F. C.↗

Neutron-gamma techniques for planetary exploration

Chemical analysis of planetary surfaces is necessary for the understanding of the origin and evolutionary processes of the solar system. Orbital lunar geochemical experiments performed during the Apollo 15 and 16 demonstrated that even with a low neutron flux (fast and thermal), reliable results could be extracted. The possibility of using a compact 14 MeV neutron generator for geochemical analysis of planetary surfaces, comets and asteroids is currently studied. This method allows the determination of bulk chemical composition, even in the presence of an atmosphere. This would be possible on the surface of Venus, for example, where alternate methods such as sample return are impractical. This method can be used for continuous monitoring of elemental abundances from a roving vehicle, for example, on the surface of Mars.

Johnson, R. G.↗

Sample selection in foreign similarity regions for multicrop experiments

The selection of sample segments in the U.S. foreign similarity regions for development of proportion estimation procedures and error modeling for Argentina, Australia, Brazil, and USSR in AgRISTARS is described. Each sample was chosen to be similar in crop mix to the corresponding indicator region sample. Data sets, methods of selection, and resulting samples are discussed.

Malin, J. T.↗

Evaluation of a high-throughput method for processing sponge-stick samples to detect viable, non-spore-forming biothreat agents

After a bioterrorism incident, surface sampling is often used to determine the extent of contamination and exposure, guiding decontamination efforts and decisions for re-occupancy of affected sites. The sponge-stick (SS) is a preferred and commonly used device for sample collection to detect both spore-forming and non-spore-forming biothreat agents from non-porous surfaces. Here, in this study, a recently developed high-throughput method (HTM) for processing SS samples to detect viable Bacillus anthracis spores was adapted for detection of non-spore-forming biothreat agents, Yersinia pestis and Francisella tularensis. The scalable HTM was used to process up to 20 SS samples simultaneously, compared to the current stomacher-based method which processes one SS at a time. Comparisons of the HTM and the stomacher-based method were statistically indistinguishable for most experiments (P > 0.05) with HTM recoveries of 37–60 % for Y. pestis inoculated at 102–103 cells/SS and held 48 h at 4 °C to mimic sample transport/storage. The HTM was integrated with Rapid Viability-Polymerase Chain Reaction (RV-PCR) analysis to detect viable Y. pestis in the presence of particulate contamination (Arizona Test Dust, ATD). This approach detected Y. pestis inoculated at 20 cells/SS and ATD did not impact detection (P > 0.05). F. tularensis showed significantly lower recoveries between no-hold time and 48-h hold time (4 °C, P < 0.05) using the HTM, which further testing showed could be due to toxicity of the neutralizing buffer used for SS pre-wetting. With modifications, this method could enhance throughput capacity while maintaining similar recovery efficiencies to current methods for other non-spore-forming bacterial pathogens.

Biological and medical sciences↗

Measurements of Neutron Scattering from a Copper Sample Using a Quasi-Differential Method in the Region from 2 keV to 20 MeV

Neutron scattering from a copper sample was measured at Rensselaer Polytechnic Institute utilizing the quasi-differential method. The measurement spanned the energy range from 0.5 to 20 MeV using the high-energy scattering system and from 2 keV to 0.5 MeV using the new mid-energy scattering system. Copper was selected as a material of interest to measure due to large discrepancies between experiments and simulations of the Zeus benchmark. The Zeus benchmark consists of a copper reflected highly enriched uranium system, and the angular distribution of copper scattering was thought to potentially be the cause of the discrepancy. The copper measurements found differences in the scattering response particularly in the incident energy region from 1 to 2 MeV for the high-energy measurement and from 2 to 4 keV in the mid-energy system. These differences are particularly noticeable at angles near 90 deg in the high-energy system and back angles in the mid-energy system. Additionally, for ENDF/B-VIII.0 there is a large discrepancy at the forward angle in the energy range around 0.5 MeV. For these reasons, a new evaluation of copper scattering utilizing these results is recommended and perhaps could help to improve the agreement with the Zeus benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mapping the Structure of Heterogeneous Materials

Image-processing microdensitometer/Fourier analyzer yields statistics of subcomponent distribution. Nondestructive method for studying structure heterogeneous materials uses energy-dispersive X-ray analysis in scanning electron microscope. Scanning microdensitometer/Fourier analyzer (SMFA) is applied to SEM images to obtain statistics about sample structure. Method originally developed for studying effect on combustion of fine structure of composite solid propellants.

Strand, L. D.↗

Harmonic analysis of discrete tracers of large-scale structure

It is commonplace in cosmology to analyze fields projected onto the celestial sphere, and in particular density fields that are defined by a set of points e.g. galaxies. When performing an harmonic-space analysis of such data (e.g. an angular power spectrum) using a pixelized map one has to deal with aliasing of small-scale power and pixel window functions. We compare and contrast the approaches to this problem taken in the cosmic microwave background and large-scale structure communities, and advocate for a direct approach that avoids pixelization. We describe a method for performing a pseudo-spectrum analysis of a galaxy data set and show that it can be implemented efficiently using well-known algorithms for special functions that are suited to acceleration by graphics processing units (GPUs). The method returns the same spectra as the more traditional map-based approach if in the latter the number of pixels is taken to be sufficiently large and the mask is well sampled. The method is readily generalizable to cross-spectra and higher-order functions. It also provides a convenient route for distributing the information in a galaxy catalog directly in harmonic space, as a complement to releasing the configuration-space positions and weights, and a route to spectral apodization. Finally, we make public a code enabling the application of our method to existing and upcoming datasets.

79 ASTRONOMY AND ASTROPHYSICS↗

Redshift inference from the combination of galaxy colours and clustering in a hierarchical Bayesian model – Application to realistic N -body simulations

ABSTRACT Photometric galaxy surveys constitute a powerful cosmological probe but rely on the accurate characterization of their redshift distributions using only broad-band imaging, and can be very sensitive to incomplete or biased priors used for redshift calibration. A hierarchical Bayesian model has recently been developed to estimate those from the robust combination of prior information, photometry of single galaxies, and the information contained in the galaxy clustering against a well-characterized tracer population. In this work, we extend the method so that it can be applied to real data, developing some necessary new extensions to it, especially in the treatment of galaxy clustering information, and we test it on realistic simulations. After marginalizing over the mapping between the clustering estimator and the actual density distribution of the sample galaxies, and using prior information from a small patch of the survey, we find the incorporation of clustering information with photo-z’s tightens the redshift posteriors and overcomes biases in the prior that mimic those happening in spectroscopic samples. The method presented here uses all the information at hand to reduce prior biases and incompleteness. Even in cases where we artificially bias the spectroscopic sample to induce a shift in mean redshift of $\Delta \bar{z} \approx 0.05,$ the final biases in the posterior are $\Delta \bar{z} \lesssim 0.003.$ This robustness to flaws in the redshift prior or training samples would constitute a milestone for the control of redshift systematic uncertainties in future weak lensing analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte Carlo control loops for cosmic shear cosmology with DES Year 1 data

Weak lensing by large-scale structure is a powerful probe of cosmology and of the dark universe. This cosmic shear technique relies on the accurate measurement of the shapes and redshifts of background galaxies and requires precise control of systematic errors. Monte Carlo control loops (MCCL) is a forward modeling method designed to tackle this problem. It relies on the ultra fast image generator (UFig) to produce simulated images tuned to match the target data statistically, followed by calibrations and tolerance loops. Here, we present the first end-to-end application of this method, on the Dark Energy Survey (DES) Year 1 wide field imaging data. We simultaneously measure the shear power spectrum $C_ℓ$ and the redshift distribution $n(z)$ of the background galaxy sample. The method includes maps of the systematic sources, point spread function (PSF), an approximate Bayesian computation (ABC) inference of the simulation model parameters, a shear calibration scheme, and a fast method to estimate the covariance matrix. We find a close statistical agreement between the simulations and the DES Y1 data using an array of diagnostics. In a nontomographic setting, we derive a set of $C_ℓ$ and $n(z)$ curves that encode the cosmic shear measurement, as well as the systematic uncertainty. Following a blinding scheme, we measure the combination of $Ω_m$, $σ_8$, and intrinsic alignment amplitude $A_{IA}$, defined as $S_8D_{IA}=σ_8(Ω_m/0.3)^{0.5}D_{IA}$, where $D_{IA}=1-0.11(A_{IA}-1)$. We find $S_8D_{IA}=0.8954_{-0.039}^{+0.054}$, where systematics are at the level of roughly 60% of the statistical errors. We discuss these results in the context of earlier cosmic shear analyses of the DES Y1 data. Our findings indicate that this method and its fast runtime offer good prospects for cosmic shear measurements with future wide-field surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental analysis of computer system dependability

This paper reviews an area which has evolved over the past 15 years: experimental analysis of computer system dependability. Methodologies and advances are discussed for three basic approaches used in the area: simulated fault injection, physical fault injection, and measurement-based analysis. The three approaches are suited, respectively, to dependability evaluation in the three phases of a system's life: design phase, prototype phase, and operational phase. Before the discussion of these phases, several statistical techniques used in the area are introduced. For each phase, a classification of research methods or study topics is outlined, followed by discussion of these methods or topics as well as representative studies. The statistical techniques introduced include the estimation of parameters and confidence intervals, probability distribution characterization, and several multivariate analysis methods. Importance sampling, a statistical technique used to accelerate Monte Carlo simulation, is also introduced. The discussion of simulated fault injection covers electrical-level, logic-level, and function-level fault injection methods as well as representative simulation environments such as FOCUS and DEPEND. The discussion of physical fault injection covers hardware, software, and radiation fault injection methods as well as several software and hybrid tools including FIAT, FERARI, HYBRID, and FINE. The discussion of measurement-based analysis covers measurement and data processing techniques, basic error characterization, dependency analysis, Markov reward modeling, software-dependability, and fault diagnosis. The discussion involves several important issues studies in the area, including fault models, fast simulation techniques, workload/failure dependency, correlated failures, and software fault tolerance.

Iyer, Ravishankar, K.↗

Microgravity Testing of a Surface Sampling System for Sample Return from Small Solar System Bodies

The return of samples from solar system bodies is becoming an essential element of solar system exploration. The recent National Research Council Solar System Exploration Decadal Survey identified six sample return missions as high priority missions: South-Aitken Basin Sample Return, Comet Surface Sample Return, Comet Surface Sample Return-sample from selected surface sites, Asteroid Lander/Rover/Sample Return, Comet Nucleus Sample Return-cold samples from depth, and Mars Sample Return [1] and the NASA Roadmap also includes sample return missions [2] . Sample collection methods that have been flown on robotic spacecraft to date return subgram quantities, but many scientific issues (like bulk composition, particle size distributions, petrology, chronology) require tens to hundreds of grams of sample. Many complex sample collection devices have been proposed, however, small robotic missions require simplicity. We present here the results of experiments done with a simple but innovative collection system for sample return from small solar system bodies.

Franzen, M. A.↗

A model study of potential sampling errors due to data scatter around expendable bathythermograph transects in the tropical Pacific

A linear multiple vertical-mode model described by McPhaden et al. (1988) is used to examine potential errors due to data scatter around expendable bathythermograph (XBT) transects in the tropical Pacific. Two methods of sampling are compared. In the first, the model was sampled along approximately straight lines of grid points corresponding to the mean positions of XBT tracks in the eastern, central, and western Pacific; in the second, the model was sampled again at the dates and locations of actual XTB casts for 1979-1983. The model indicates that the data scattered zonally around XBT transects in general can lead to about 2 dyn cm error in dynamic height in composite sections of XBT data. Errors larger than 2 dyn cm occurred in regions where XBT sample spacing in the zonal direction was insufficient to resolve Rossby wave variations in the model.

Mcphaden, Michael J.↗

Evidence of gas phase nucleation of nanodiamond in microwave plasma assisted chemical vapor deposition

The mechanism of ballas-like nanodiamond formation still remains elusive, and this work attempts to analyze its formation in the framework of activation energy (Ea) of nanodiamond films grown from a H2/CH4 plasma in a 2.45 GHz chemical vapor deposition system. The Ea was calculated from the Arrhenius equation corresponding to the thickness growth rate using substrate temperature (∼1000−1300 K) in all the calculations. While the calculated values matched with the Ea for nanodiamond formation throughout the literature, these values of ∼10 kcal/mol were lower compared to ∼15–25 kcal/mol for standard single crystal diamond (SCD) formation, concluding thus far that the energetics and processes involved were different. Further, the substrate preparation and sample collection method were modified while keeping the growth parameters constant. Unseeded Si substrate was physically separated from the plasma discharge by a molybdenum disk with a pinhole drilled in it. Small quantity of a sample substance was collected on the substrate. The sample was characterized by electron microscopy and Raman spectroscopy, confirming it to be nanodiamond, thus suggesting that nanodiamond self-nucleated in the plasma and flowed to the substrate that acted as a mere collection plate. It is hypothesized then, if nanodiamond nucleates in gas phase, gas temperature has to be used in the Arrhenius analysis. The Ea values for all the nanodiamond films were re-calculated using the simulated gas temperature (∼1500−2000 K) obtained from a simple H2/CH4 plasma model, giving new values within the range characteristic to SCD formation. Based on these findings, a unified growth mechanism for nanodiamond and SCD is proposed, concluding that the rate-limiting reactions for nanodiamond and SCD formation are the same.

Materials Science↗

Gas chromatography/ion mobility spectrometry as a hyphenated technique for improved explosives detection and analysis

Ion Mobility Spectrometry (IMS) is currently being successfully applied to the problem of on-line trace detection of plastic and other explosives in airports and other facilities. The methods of sample retrieval primarily consist of batch sampling for particulate residue on a filter card for introduction into the IMS. The sample is desorbed into the IMS using air as the carrier and negative ions of the explosives are detected, some as an adduct with a reagent ion such as Cl(-). Based on studies and tests conducted by different airport authorities, this method seems to work well for low vapor pressure explosives such as RDX and PETN, as well as TNT that are highly adsorptive and can be found in nanogram quantities on contaminated surfaces. Recently, the changing terrorist threat and the adoption of new marking agents for plastic explosives has meant that the sample introduction and analysis capabilities of the IMS must be enhanced in order to keep up with other detector developments. The IMS has sufficient analytical resolution for a few threat compounds but the IMS Plasmogram becomes increasingly more difficult to interpret when the sample mixture gets more complex.

Mercado, AL↗