Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “locking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Subharmonic Shapiro steps in depinning dynamics of a two-dimensional solid dusty plasma modulated by one-dimensional nonlinear deformed periodic substrates

Langevin dynamical simulations are performed to investigate the depinning dynamics of a two-dimensional (2D) solid dusty plasma, which is modulated by one-dimensional (1D) nonlinear deformed periodic substrates, and also driven by the combination of the DC and AC forces. As the DC driving force increases gradually, pronounced subharmonic and harmonic Shapiro steps are discovered under the combined modulation of the deformed substrate and the external AC drive. Here, these observed subharmonic and harmonic Shapiro steps are attributed to the dynamic mode locking. The data analysis results indicate that the nonlinear deformed substrate strongly influences these subharmonic Shapiro steps, which can be accurately diagnosed using the fraction of sixfold coordinated particles. Furthermore, the diagnostic of the kinetic temperature clearly indicates the difference between harmonic and subharmonic Shapiro steps, i.e., the particle motion is slightly less synchronized at subharmonic Shapiro steps, caused by the unstable locations of the deformed substrate.

36 MATERIALS SCIENCE↗

Crystal structure of vancomycin bound to the resistance determinant D -alanine- D -serine

Vancomycin is a glycopeptide antibiotic that for decades has been a mainstay of treatment for persistent bacterial infections. However, the spread of antibiotic resistance threatens its continued utility. In particular, vancomycin-resistant enterococci (VRE) have become a pressing clinical challenge. Vancomycin acts by binding and sequestering the intermediate Lipid II in cell-wall biosynthesis, specifically recognizing a D-alanine-D-alanine dipeptide motif within the Lipid II molecule. VRE achieve resistance by remodeling this motif to either D-alanine-D-lactate or D-alanine-D-serine; the former substitution essentially abolishes recognition by vancomycin of Lipid II, whereas the latter reduces the affinity of the antibiotic by roughly one order of magnitude. The complex of vancomycin bound to D-alanine-D-serine has been crystallized, and its 1.20 Å X-ray crystal structure is presented here. This structure reveals that the D-alanine-D-serine ligand is bound in essentially the same position and same pose as the native D-alanine-D-alanine ligand. The serine-containing ligand appears to be slightly too large to be comfortably accommodated in this way, suggesting one possible contribution to the reduced binding affinity. In addition, two flexible hydroxyl groups – one from the serine side chain of the ligand, and the other from a glucose sugar on the antibiotic – are locked into single conformations in the complex, which is likely to contribute an unfavorable entropic component to the recognition of the serine-containing ligand.

36 MATERIALS SCIENCE↗

Atomic structure and formation mechanism of a newly discovered charge density wave in the m = 2 monophosphate tungsten bronze

The m = 2 member of the monophosphate tungsten bronze family had been thought to be the only one without an electronic instability at low temperature. In this paper, we report the discovery of a charge density wave phase in this compound, with a transition temperature of 290 K and an incommensurate modulation vector q = 0.245b* + ξc*, which reaches a lock-in with a commensurate vector at 130 K. The presence of this new phase is confirmed by diffraction and resistivity measurements. Pre-transitional dynamics are investigated using diffuse and inelastic X-ray scattering, revealing a clear Kohn anomaly. We analyze both structural and electronic contributions to the phase transition, providing a comprehensive picture of the mechanism driving this newly identified instability.

Minelli, Arianna [ORNL] (ORCID:0000000283103712)↗

A Secondary Control Framework for Microgrid Interoperability With Vendor-Agnostic Grid-Forming Units: Design, Implementation, and Demonstration via Large-Scale Hardware Setup

The reliable operation of islanded microgrids increasingly depends on secondary controls that restore voltage and frequency to nominal values and ensure accurate active and reactive power sharing. Centralized secondary control architectures achieve high accuracy through global coordination at the cost of single-point failures and limited scalability compared with decentralized/distributed approaches. But a critical gap remains in addressing the interoperability and vendor-agnostic operation of secondary controls in real-world microgrids where heterogeneous diesel generator(s) and grid-forming (GFM) inverter(s) from multiple manufacturers always coexist. Practical and vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids with multiple GFM units have not yet been developed; therefore, this paper proposes an interoperable and vendor-agnostic secondary control framework that operates seamlessly across GFM units from different vendors without relying on proprietary controls and protocols, hardware, or lock-ins. The framework leverages existing communication infrastructures (e.g., Modbus TCP/IP) to enable cost-effective deployment while addressing practical challenges, such as packet loss and quantization errors. Mitigation strategies-including data averaging, situational event-triggered control, and finite-iteration execution-are introduced to enhance reliability under real-world conditions. A generalized modeling and design framework is also presented, supported by robustness analysis to demonstrate independence from vendor-specific implementations. The proposed framework is validated through a large-scale hardware demonstration using a 3-$\phi$, 480-V, 60-Hz, 713-kVA laboratory hardware microgrid involving a heterogeneous diesel generator and multiple GFM inverters, showcasing its effectiveness in achieving stable voltage and frequency restoration and accurate power sharing under practical constraints. The results highlight the framework's potential as a scalable and practical solution for next-generation microgrids requiring openness, standard framework, and interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Ultra-Fast Inrush-Current-Free Startup Method for Grid-tie Inverter without Voltage Sensors

This paper proposes an ultra-fast inrush-currentfree startup method for grid-tie inverters without voltage sensors and phase-locked loop (PLL). Traditionally, the grid-tie inverter needs the voltage measured from points of common couplings (PCC) to generate the phase angle via PLL for inverter pulsewidth- modulation (PWM) signals. The startup procedure is slow and inrush current occurs if the initial PWM does not match the unknown grid voltage well. This paper proposes a startup method that only uses measured inverter ac currents to generate the initial PWM by controlling the current to zero. The generated PWM pattern can be used to reproduce the real grid voltage regardless of the grid impedance. The zero-crossing points of the grid voltage are detected and then used for grid synchronization. The proposed startup procedure only needs a few cycles (16.67 ms/cycle) to reliably synchronize the inverter to the grid without any inrush current. Simulation and experimental results are presented to verify the effectiveness of this control strategy.

He, Yuchen↗

Kensor: Coordinated Intelligence from Co-Located Sensors

Internet of Things (IoT) is becoming more pervasive in many installations, including homes, manufacturing plants, and industrial facilities of all kinds. The data that IoT produces is a reflection of usual behavior such as daily routines and scheduled tasks, but also from unexpected behavior due to unintentional or undesirable abnormalities. Here, we focus on achieving coordinated intelligence about normal and abnormal phenomena from multiple sensors that are geographically colocated in close proximity, monitoring and controlling a set of co-located devices. Given a set of co-located sensors, we seek an intelligent approach that would automatically determine the “normal” patterns of behaviors among the correlated sensors. After normal behavior is extracted, later monitoring should detect any deviant variations over time. An example application is an entry monitoring and alert system for facilities such as nuclear reactors, where badge readers, door locks, lights, weight trackers and other co-located sensors at the entry point are collectively tracked. To address this problem, we identify the possible solution approach that can be used to solve its different variants. The implemented model is developed as a combination of rules and Markov Chain methods.

Kotevska, Olivera↗

Custom Accessors: Enabling Scalable Data Ingestion, (Re-)Organization, and Analysis on Distributed Systems

The emerging class of high velocity and high volume data analytic workflows comprise interwoven data ingestion, organization, and processing stages, with ingestion and organization steps often contributing comparable or even higher computational costs than actual processing steps. Since complex workflows consist of a variety of phases that view and use data differently, being able to construct efficient, scalable, distributed data structures (arrays, vectors, sets, maps, and multi-maps) is essential and requires custom methods to extend and shrink containers, analyze and position data, and, maintain globallyconsistent meta-data. In this paper, we propose a novel datastructure access paradigm based on the concept of Accessors. At a high level, accessors are customizable callable objects that can modify the behavior of insert, read, update, and delete operations for distributed containers while preserving atomicity guarantees. Accessors provide a very clean and natural way to implement a variety of programming patterns, e.g., conditional insertion/deletion and cascading computations, which would be otherwise hard (or even impossible) to express in parallel and distributed settings without using locks. We demonstrate the practicality and usefulness of our approach with two representative use cases and study the performance of these applications on a distributed High-Performance Computing system. Our analysis highlights that our proposed abstraction allows for an effective overlapping and concurrent execution of different workflow steps (e.g., data ingestion and analysis), which in a conventional analytics pipeline would execute sequentially, contributing cumulatively to the overall latency.

Castellana, Vito G. [BATTELLE (PACIFIC NW LAB)] (O↗

Hvac: Removing I/O Bottleneck for Large-Scale Deep Learning Applications

Scientific communities are increasingly adopting deep learning (DL) models in their applications to accelerate scientific discovery processes. However, with rapid growth in the computing capabilities of HPC supercomputers, large-scale DL applications have to spend a significant portion of training time performing I/O to a parallel storage system. Previous research works have investigated optimization techniques such as prefetching and caching. Unfortunately, there exist non-trivial challenges to adopting the existing solutions on HPC supercomputers for large-scale DL training applications, which include non-performance and/or failures at extreme scale, lack of portability and generality in design, complex deployment methodology, and being limited to a specific application or dataset. To address these challenges, we propose High-Velocity AI Cache (HVAC), a distributed read-cache layer that targets and fully exploits the node-local storage or near node-local storage technology. HVAC seamlessly accelerates read I/O by aggregating node-local or near node-local storage, avoiding metadata lookups and file locking while preserving portability in the application code. We deploy and evaluate HVAC on 1,024 nodes (with over 6000 NVIDIA V100 GPUS) of the Summit supercomputer. In particular, we evaluate the scalability, efficiency, accuracy, and load distribution of HVAC compared to GPFS and XFS-on-NVMe. With four different DL applications, we observe an average 25 % performance improvement atop GPFS and 9% drop against XFS-on-NVMe, which scale linearly and are considered the performance upper bound. We envision HVAC as an important caching library for upcoming HPC supercomputers such as Frontier.

Khan, Awais↗

Grid-Forming Control Using TAPAS Software Defined Inverters

Here, this paper discusses the design and hardware implementation aspects of state-feedback primary control for grid forming inverters. The primary control consists of two tracking control laws: voltage tracking and frequency/angle tracking. The voltage tracking control requires voltage and current at the inverter's switch terminal (i.e. before the filter). The fundamental component of switch terminal voltage is estimated using the inverter's average model while the switch terminal current is estimated using an observer, thus obviating the need for sensors at the switch terminals. The measurements of frequency and angle(s) needed for frequency/angle tracking are noisy due to measurement noises and inherent delays in the phase locked loop (PLL). Conditioning of these feedback signals is discussed in detail, and the corresponding changes in the control design are provided to better attenuate the impact of noises. Effectiveness of the proposed design and implementation is demonstrated by the implementation results from TAPAS software defined inverter (SDI).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impedance Modeling and Stability Analysis for the PLL-less and Voltage Sensor-less Grid-tied Converters

The newly developed control methodology, which omits the phase-locked loop (PLL) and voltage sensor, has garnered considerable attention for its rapid dynamic response and reduced hardware expenses. Nonetheless, its stability concerns have not yet been thoroughly scrutinized. In this paper, the impedance modeling of the PLL-less and voltage sensorless control strategy has been established. The impedance model has been contrasted with the traditional PLL-based control scheme. Our findings demonstrate that the PLL-less and voltage sensorless control approach lacks the negative resistance behavior that is frequently observed in the traditional scheme, which results in unstable operations. Furthermore, the role of virtual resistance has been examined. To substantiate the aforementioned findings, simulation results are presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Switching-Cycle-Based Startup for Grid-tied Inverters

This paper presents a novel switching cycle-based startup approach that eliminates the need for voltage sensors and phase-locked loops. Here, the proposed method surpasses the bandwidth limitations inherent in traditional PLL-based synchronization techniques and attains grid synchronization of the inverter within two switching cycles. Despite the absence of voltage sensors and PLLs, this synchronization is achieved without inrush currents. Furthermore, the startup method does not necessitate the addition of any hardware or an increase in software complexity. Simulation and experimental results are presented to verify the effectiveness of the proposed method.

42 ENGINEERING↗

Decoupled Active and Reactive Power Control without PLL Requirement for Differential Buck Converter

This paper presents a decoupled active and reactive power control for the differential buck converter. This control does not require phase locked loop (PLL) for synchronization. Also, it achieves active and reactive power control in a simple single control loop structure. The differential buck converter has the capability to compensate the double line frequency power ripple without relying on additional hardware. Particularly, the Common Mode (CM) operation is used for active double line frequency power ripple absorption. Whereas, the Differential Mode (DM) operation is used as an active and reactive power exchanging port between the converter and the grid at the point of common coupling (PCC). The motivation behind this paper proposal are: (i) to avoid PLL induced instabilities, especially, when connecting the differential buck converter with weak grid, and (ii) direct active and reactive power control for the differential buck in a single loop control. The theoretical analyses are verified with a 5 kW converter with only 50 μF decoupling capacitor connected to a weak grid.

Khan, Ahmad↗

Enabling Technology for Energy Sustainability: Power Electronic Converter Control for Renewables

To ensure high penetration of renewable energy sources into power grids, their interfacing inverters need to be designed to provide grid support functions. Important grid support functions include frequency and voltage support. To this end, the research community has recently invested heavily on grid-forming control pilot projects. Grid forming control aims to replace traditional grid following control, which is based on phase-locked loop and can achieve decoupled real and reactive power control. Here, in this article, we review the state-of-the-art grid following and forming technology and point out some deficiencies in dynamic performance in the widely adopted grid-forming control design. We also examine how to ensure that the vector control capable of decoupled real and reactive power regulation can also be achieved in the grid forming design. This type of design has been prototyped and shown great potential to enable retrofitting of large amounts of grid-following controllers through purely software algorithm update. The technology ensures reliable operation of power grids with high penetration of IBRs, thereby further reducing fossil fueled energy sources and cut down carbon emission.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Effectiveness of Recurrent Neural Networks for Live Modeling of Cyber-Physical Systems

Attention to cyber security of cyber-physical systems (CPS) has led to the development of innovative cyber-resilient methodologies to ensure early detection and mitigation of cyber anomalies and threats. The concept of Digital Twin (DT) has recently emerged as one of the approaches to achieve the objective of resilience. In the approach using DT, a software-based live model of a target CPS is used to continuously monitor, surveil and verify the correctness of the target CPS operation. In this paper, we empirically study the effectiveness of Recurrent Neural Network (RNN)-based models as the basis of DT-based resilience. We uncover the important characteristics of an RNN-based solution with experimentation on a lab-scale Canal Lock CPS emulator with live validations and attack scenarios. For the first time, we demonstrate actual, real-time use of a RNN-based model as a DT for performing live analysis on an operational CPS. Based on the observed results, we highlight the importance of a DT model's training interval, prediction interval and CPS polling interval in the process of anomaly detection. We uncover the limitations in anomaly detection due to real-time synchronization needs of the RNN-based DT. We highlight this uncovered tug of war between synchronization and anomaly detection is inherent in any complex CPS that is monitored and synchronized by relying on the same sensor streams of ground truth for both synchronization as well as anomaly detection.

Yoginath, Srikanth↗

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631↗

A Dynamically-Reconfigurable Burst-Mode Link Using a Nanosecond Photonic Switch

Fast optical circuit switching has great potential to solve scaling issues with traditional packet-switch based networks and improve bandwidth and power efficiency in datacenter and high-performance computing applications. One difficultly in utilizing a fast optical switch is that the optical signal must be rapidly reacquired after each switching event so as to not significantly impact the overall throughput of the system. In this work we present a system-level integration of a nanosecond-scale $2 \times 2$ silicon photonic switch with a 25-Gbps burst-mode receiver that can lock in 31 ns. A novel FPGA-based control plane was used to generate test data, control the silicon photonic switch and burst-mode receiver, and measure bit errors at 12.5 and 20 Gbps. Error-free links (BER $< 10^{-12}$ ) with system-level reconfiguration times below 60 ns (at 20 Gbps) and 90 ns (at 12.5 Gbps) including bit- and frame-synchronization are demonstrated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting From Hot-Humid High-Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable legacy aluminum back surface field cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60 degrees C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission Technical Specification 62804-1; 70 degrees C/70% RH for 200 h; and 85 degrees C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage curve tracing. Final characterizations included: Suns-Voc, spatial mapping of external quantum efficiency, high-resolution photoluminescence, EL, and dark lock-in thermography imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy, and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500 V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline corrosion and delamination, and other concurrent degradation modes. SEM/EDS and SAM identified the conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

Cooperative Inverters to Overcome PLL Malfunctions

This paper presents a cooperative strategy between smart inverters to overcome instability and undesired trips of inverters caused by Phase-Locked Loop (PLL) malfunctions. For the grid-interactive inverter, PLL is typically required to measure the phase angle of the AC voltage at the Point of Common Coupling (PCC) of the inverter. Accurate phase-angle measurement is critical for grid-interactive inverters to stay synchronized with the power grid. If the inverters are interconnected through a communication link, they can support each other by sharing their grid information, such as phase-angles at their PCCs. The cooperative strategy utilizes the phase-angles and voltages at PCCs in a neighborhood to identify any possible PLL malfunctions or measurement inaccuracies and then enable the inverters to make corrective decisions. The efficacy of the cooperative strategy has been verified through simulation results in MATLAB/Simulink environment in this paper.

Sadeque, Fahmid↗