Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

A test of Lee's quasi-linear theory of ion acceleration by interplanetary traveling shocks

Lee's (1983) quasi-linear theory of ion acceleration is tested using ISEE-3 measurements of the November 12, 1978 quasi-parallel interplanetary shock. His theory accounts with varying degrees of precision for the energetic proton spatial profiles; the dependence of the spectral index of the power law proton velocity distribution upon the shock compression ratio; the power law dependence of the upstream proton scalelength upon energy; the absolute magnitude of the upstream proton scale length; the behavior of the energetic proton anisotropy upstream and downstream of the shock; the behavior of the alpha-particle proton ratio upstream; the equality of the spatial scale lengths at the shock of the upstream waves and of the protons that resonate with them; and the dependence of the integrated wave energy density upon the proton energy density at the shock. However, the trace magnetic field frequency spectra disagree with his theory in two ways. The part of the spectrum that can resonate with the observed protons via first-order cyclotron resonance is flat, whereas Lee's theory predicts an f exp - 7/4 frequency dependence for the November 12 shock. Higher frequency waves, which could not resonate with the observed upstream protons, increased in amplitude as the shock approached, suggesting that they too were generated by the shock.

Kennel, C. F.↗

Beam Envelope Variation due to Space-Charge Neutralization

Our non-invasive, time-resolved diamagnetic loop measurements of beam size during the electron current-pulse flattop at the exit of our 20-MeV linear induction accelerator revealed that the beam size varied by about 13% during the current flattop. This was an unexpected result, since both current and energy were constant during the interval of radius variation. One possible cause, poor vacuum, was investigated using a time resolved envelope equation. It was found that sufficiently high residual-gas pressure in the downstream transport region could result in the observed variation.

43 PARTICLE ACCELERATORS↗

Superconducting six-axis accelerometer

A new superconducting accelerometer, capable of measuring both linear and angular accelerations, is under development at the University of Maryland. A single superconducting proof mass is magnetically levitated against gravity or any other proof force. Its relative positions and orientations with respect to the platform are monitored by six superconducting inductance bridges sharing a single amplifier, called the Superconducting Quantum Interference Device (SQUID). The six degrees of freedom, the three linear acceleration components and the three angular acceleration components, of the platform are measured simultaneously. In order to improve the linearity and the dynamic range of the instrument, the demodulated outputs of the SQUID are fed back to appropriate levitation coils so that the proof mass remains at the null position for all six inductance bridges. The expected intrinsic noise of the instrument is 4 x 10(exp -12)m s(exp -2) Hz(exp -1/2) for linear acceleration and 3 x 10(exp -11) rad s(exp -2) Hz(exp -1/2) for angular acceleration in 1-g environment. In 0-g, the linear acceleration sensitivity of the superconducting accelerometer could be improved by two orders of magnitude. The design and the operating principle of a laboratory prototype of the new instrument is discussed.

Paik, H. J.↗

Seeded Stage III glass dissolution behavior of a statistically designed glass matrix

The glass dissolution rate of some glasses accelerates after prolonged time spent at a slow, residual glass dissolution rate. This phenomenon is referred to as Stage III behavior. Here, the acceleration in glass dissolution rate linked to Stage III behavior is significant and may be the most impactful to long-term performance of glass in a repository. This work is aimed at understanding the effect of glass composition on Stage III behavior to add a level of technical defensibility to glass disposal. To this end, a set of twenty-four glass compositions were statistically designed, where eight glass components (SiO 2 , B 2 O 3 , Al 2 O 3 , CaO, Na 2 O, SnO 2 , ZrO 2 , and Others) have been independently varied in order to study the individual effects of each. These glasses have been subjected to static dissolution tests at 90 °C in deionized water and then seeded with zeolite Na-P2 28 days into the testing to induce Stage III behavior. The response of the glasses to the zeolite seeds fell into four primary types: 1) no response to seeds; 2) an immediate linear sustained acceleration in the rate; 3) an immediate linear acceleration in the rate followed by a decrease; and, 4) a progressive acceleration in the rate that is concurrent with the addition of the seeds. The main glass components observed to influence these behaviors were CaO, Al 2 O 3 , B 2 O 3 , and ZrO 2 , where: 1) CaO influenced which glasses showed a Stage III response to seeds (high CaO: Types 2, 3, and 4) or did not respond to seeds (low CaO: Type 1), 2) Al 2 O 3 and B 2 O 3 influenced which glasses showed a sustainable Stage III response (high Al 2 O 3 : Types 2 and 4) versus transitory response (low Al 2 O 3 and high B 2 O 3 : Type 3), and 3) ZrO 2 concentration influenced whether glasses showed a linear (high ZrO 2 : Type 2) versus progressive (low ZrO 2 : Type 4) response to seeds.

36 MATERIALS SCIENCE↗

Beam Breakup Simulations for the Scorpius Flash-Radiography Accelerator

Beam breakup (BBU) in linear induction accelerators (LIAs) used for flash radiography is problematic because the high-frequency beam motion can blur the source spot, thereby degrading resolution. Amplification of BBU depends directly on details of cell design and is suppressed in operation by the solenoidal magnetic field focusing on the electron beam. Therefore, much effort has gone into design of the cells and magnetic focusing for the new Scorpius radiography LIA. Here, in this article, we use computer simulations to demonstrate that BBU in Scorpius should be no more than in present radiography LIAs at the Los Alamos National Laboratory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physical conditions for conducting radiobiological experiments in beams of accelerated particles with high linear energy transfer

The design and construction of an accelerator to conduct radiobiological experiments is reported that uses aluminum filters to control the accelerated ion beam while preserving its stability, and a vacuum chamber to conduct the ion beam with the help of a collector through a lavsan exit port to the target. Depth distribution of the absorbed dose from a monodirectional ion beam is practically completely represented by the change in the energy spectrum of the biological object.

Kudryashov, Y. I.↗

TOWARD A METHOD FOR SCALING HUMAN BODY MODELS IN AN IMU-BASED WORKFLOW

BACKGROUND Scaled biomechanical models can more accurately inform crew health decisions when tailored to the wide range of astronaut sizes. One component to improve scaling of existing models to better represent each unique astronaut’s size is the individual length scaling of limbs. Traditionally, these lengths are determined by motion capture or manual measurement. A new method is herein proposed for length scaling which can be done by measuring linear and angular accelerations at a desired point during isolated motion around a point of rotation, then calculating the distance between the desired point and point of rotation. When an Inertial Measurement Unit (IMU) device is placed at the distal point of a limb, the isolated motion is about that limb’s proximal joint. For example, to measure forearm length, an IMU is placed at the wrist, the point of rotation is at the elbow, and the isolated motion is forearm flexion and extension. These calculated lengths are then used to scale models to each unique astronaut’s size, thereby improving the applicability of the model. This method of scaling limb segments can be used for any limb that has an easily defined proximal joint for the limb to rotate around including hands, arms, legs, feet. Utilizing IMUs for data collection also provides the synergistic ability to record data without a dedicated space in a room with many cameras, therefore reducing the data collection footprint, or record data where optical motion capture is not possible, such as inside a spacesuit. METHODS AND RESULTS To test this method, upper body data collection was performed with 5 Xsens DOT IMUs on a single subject. IMUs consist of an accelerometer, a gyroscope, and a magnetometer which collect linear acceleration, angular velocity, and magnetic fluctuations, respectively. Before any ground-based laboratory collection, the magnetic fluctuations are used to correct the heading of the IMU in space relative to the Earth’s magnetic field. The direct measurement of angular velocity is integrated to calculate angular acceleration. Then the linear acceleration ( a ) and angular acceleration (α) are solved using r = at/α to calculate the radius, which in this case is the distance between the IMU and the point of rotation (i.e., segment length). The IMU must be placed at the most distal point of the limb being measured (i.e., ankle if measuring lower leg length) and the test plan must consist of an isolated motion about that limb’s proximal joint (i.e., knee flexion and extension if measuring lower leg length). The distances (radii) calculated at every time interval were filtered (bandpass filter keeping 5th-90th percentile data) to eliminate outliers and spurious data that occur when the isolated motion was stopped or nearly stopped. The remaining distances were averaged, resulting in the calculated limb length. Scaling factors were then computed by dividing the calculated limb length by the unscaled model’s length. These scale factors are plugged into the Scale Tool in OpenSim [1,2] to apply the scaling to the OpenSim Full Body Rajagopal Model [3,4]. Manual measurements of limb lengths were taken before data collection started and used for comparing against the calculated lengths. The Anthropometric Survey of US Army Personnel (ANSUR II) [5] was also used as a third source of reference for limb length measurements. The following measurements were retrieved from the subject before data collection: 34.5 cm from L1 to C7 (thorax), 25.7 cm from C7 Joint Center (JC) to head vertex (neck and head), 36.3 cm from shoulder JC to elbow JC (humerus), 29.5 cm from elbow JC to wrist JC (forearm), and 16.2 cm from clavicle to acromion (clavicle). Of those five, forearm and humerus lengths were calculated using this proposed method to obtain preliminary results. The forearm length after filtering and averaging was calculated to be 37.6 cm. This is a 28% overestimation from the measured forearm length (29.5 cm). The humerus length after filtering and averaging was calculated to be 47.8 cm. This is a 31% difference from the measured subject length (36.3 cm). Sources of error include imperfect isolated motion (method currently expects that motion should be perfectly circular in a 2D plane, include no rotation of the IMU, and be relatively smooth; a more secure IMU attachment method will help), unrefined filter techniques (removed highest and lowest values with 20% high and low pass filters and no smoothing filters), arbitrary removal of stopped or near stopped data (kept data for only a short range before and after the angular velocity peaking), and a more representative method for removing gravitational acceleration is needed (current method is to zero all accelerations against a baseline taken just before the isolated motion which does not account for the gravitational acceleration changed due to IMU rotation during movement). Addressing these error sources will improve the accuracy of the limb length calculation. Next steps include creating a method for whole-body scaling estimation using individual limb scale factors. Continued pursuit of these techniques is expected to enable acquiring anthropometric information using only IMUs in real-time.

E. K. Marecki↗

Analysis Background & Noise in Stretched Wire Alignment Technique Measurements

The Stretched-Wire Alignment Technique (SWAT) is one method of magnet alignment for linear induction accelerators. The applications of SWAT have been implemented for aligning solenoid magnets on the Scorpius linear induction accelerator which will be sited at the Nevada National Security Site and the Flash X-Ray (FXR) linear induction accelerator at Lawrence Livermore National Laboratory’s Contained Firing Facility. This article describes both systematic (repeatable) and random sources of background and noise as well as practical ways to eliminate or reduce them to acceptable levels. Systematic sources include reflections from wire ends, rapid sag due to ohmic heating of the wire, magnetic materials, and shot rate. Random sources include air currents, vibration of nearby equipment, mechanical stability of test equipment, and the instruments used to measure the wire motion. Mitigations include curve fitting and adaptive noise signal cancellation, and mechanical damping. Finite Element Analysis (FEA) was used to identify and resolve a repeatable wire vibration frequency interfering with the signal resolution. Two stretched wire alignment technique set ups from Sandia National Labs and Lawrence Livermore National Lab have shown background noise sources and ways of mitigating them by either analysis methods or change of mechanical configuration. Conclusions that were drawn included the severe sensitivity of the deflection to even small external interferences of the SWAT wire such that it requires attention to detail in mechanical set up and analysis.

Linear Inductive Accelerator↗

Colossal magnetoresistance from spin-polarized polarons in an Ising system

Recent experiments suggest a new paradigm toward novel colossal magnetoresistance (CMR) in a family of materials EuM 2 X 2 (M = Cd, In, Zn; X = P, As), distinct from the traditional avenues involving Kondo–Ruderman–Kittel–Kasuya–Yosida crossovers, magnetic phase transitions with structural distortions, or topological phase transitions. Here, we use angle-resolved photoemission spectroscopy and density functional theory calculations to explore their origin, particularly focusing on EuCd 2 P 2 . While the low-energy spectral weight royally tracks that of the resistivity anomaly near the temperature with maximum magnetoresistance ( T MR ) as expected from transport-spectroscopy correspondence, the spectra are completely incoherent and strongly suppressed with no hint of a Landau quasiparticle. Using systematic material and temperature dependence investigation complemented by theory, we attribute this nonquasiparticle caricature to the strong presence of entangled magnetic and lattice interactions, a characteristic enabled by the p - f mixing. Given the known presence of ferromagnetic clusters, this naturally points to the origin of CMR being the scattering of spin-polarized polarons at the boundaries of ferromagnetic clusters. These results are not only illuminating to investigate the strong correlations and topology in EuCd 2 X 2 family, but, in a broader view, exemplify how multiple cooperative interactions can give rise to extraordinary behaviors in condensed matter systems.

36 MATERIALS SCIENCE↗

Time optimal control of manipulators with bounded accelerations

The linearity of the equations of motion of dynamical systems such as spacecraft or manipulators when controlled by acceleration commands is exploited in generating exact fast maneuvers. A simulated robot example thereof is examined, with advantages and limitations of the proposed design approach discussed in its context.

Dwyer, T. A. W., III↗

Modelling the complex evaporated gas flow and its impact on particle spattering during laser powder bed fusion

The additive manufacturing (AM) of metals is becoming an increasingly important production process with the potential to replace traditional techniques such as casting. Laser Powder Bed Fusion (LPBF) is used in many applications to print metal parts from powder. The metal powder is heated locally with sufficient laser radiation that the liquid melt easily reaches its boiling temperature, which leads to a metallic vapour jet that can entrain both powder bed particles and molten droplets. The small size of laser-matter interaction site makes a detailed experimental analysis of the process challenging. Synchrotron X-ray imaging experiments are one of the few methods which can capture the dynamic melting and solidification processes. Comparing such experiments with computer simulations of the process is an important approach in order to better understand the manufacturing process and to analyse the influence of process parameters on the evaporated gas jet and the subsequent impact on particle ejection, leading to potentially reduced AM component quality. The melting and solidification of the metal powder is simulated using an Eulerian multiphase approach based on a control volume discretization of powder bed and substrate and a volume of liquid separation from melt and gas phase. The gas phase modelled as an ideal gas reaches velocities up to 100 m/s. Lagrangian particle tracking in the simulation demonstrates that the velocity fields calculated by the Eulerian multi-phase approach in combination with a standard drag-force model lead to particle accelerations in good agreement with those measured experimentally. In order to avoid numerical laborious Lagrangian calculations, a direct method to compare an Eulerian multiphase simulation with synchrotron X-ray experiments was introduced and validated. This approach is used to analyse the influence of process parameters including laser power and laser speed on the maximal acceleration of particles from the melt pool area. While the particle acceleration increases linearly with line energy in the conduction mode, a linear decrease of the acceleration with increasing line energy can be found in the transition mode before the accel-eration increases again with line energy in the keyhole mode.

36 MATERIALS SCIENCE↗

Breakdown insensitive acceleration regime in a metamaterial accelerating structure

A new regime in radiofrequency (rf) breakdown, named the breakdown insensitive acceleration regime (BIAR), was observed in an 11.7 GHz metamaterial structure for wakefield acceleration driven by rf pulses with a duration of a few nanoseconds. In the BIAR, rf breakdown occurs without interrupting potential beam acceleration, resulting in greater resilience to breakdown. We have investigated the possibility that BIAR can support higher gradients by characterizing the breakdown in a high-power test. The peak gradient reached 190 MV / m when the structure was powered by 6 ns long rf pulses with 115 MW peak power. The short rf pulses were extracted from 65 MeV electron bunch trains with a total charge of up to 210 nC. This work has revealed the benefits of short-pulse acceleration by characterizing rf breakdown in the previously unexplored parameter space. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Fabrication and testing of the transition section between modules of a wakefield accelerator

The fabrication process is presented for a typical transition section located between each cylindrical corrugated waveguide structure comprising the wakefield accelerator module. The transition section includes couplers for extracting the 180 GHz TM 01 accelerating mode and separate couplers for extracting the 190 GHz HE 11 dipole mode, both modes induced by the electron bunch traversing the cylindrical corrugated waveguide structure. Extraction of the high-power accelerating mode reduces the heat load due to the subterahertz wave power dissipation within the corrugated accelerating structure. Extraction of the low-power dipole mode serves the purpose of detecting the electron bunch transverse oscillations within the wakefield accelerator and identifying the onset of beam breakup instability. Comprehensive testing of the fully functional transition section with an electron beam was done at the Accelerator Test Facility in Brookhaven National Laboratory which verified the functionality of the transition section. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Variable Acceleration Force Calibration System (VACS)

Conventionally, force balances have been calibrated manually, using a complex system of free hanging precision weights, bell cranks, and/or other mechanical components. Conventional methods may provide sufficient accuracy in some instances, but are often quite complex and labor-intensive, requiring three to four man-weeks to complete each full calibration. To ensure accuracy, gravity-based loading is typically utilized. However, this often causes difficulty when applying loads in three simultaneous, orthogonal axes. A complex system of levers, cranks, and cables must be used, introducing increased sources of systematic error, and significantly increasing the time and labor intensity required to complete the calibration. One aspect of the VACS is a method wherein the mass utilized for calibration is held constant, and the acceleration is changed to thereby generate relatively large forces with relatively small test masses. Multiple forces can be applied to a force balance without changing the test mass, and dynamic forces can be applied by rotation or oscillating acceleration. If rotational motion is utilized, a mass is rigidly attached to a force balance, and the mass is exposed to a rotational field. A large force can be applied by utilizing a large rotational velocity. A centrifuge or rotating table can be used to create the rotational field, and fixtures can be utilized to position the force balance. The acceleration may also be linear. For example, a table that moves linearly and accelerates in a sinusoidal manner may also be utilized. The test mass does not have to move in a path that is parallel to the ground, and no re-leveling is therefore required. Balance deflection corrections may be applied passively by monitoring the orientation of the force balance with a three-axis accelerometer package. Deflections are measured during each test run, and adjustments with respect to the true applied load can be made during the post-processing stage. This paper will present the development and testing of the VASC concept.

Rhew, Ray D.↗

Mechanically Accelerated Depolymerization of Entangled Linear Polymer Melts

Mechanical forces can enhance the chemical depolymerization of synthetic polymers when shear flow accelerates chain scission. To quantify the extent of mechanically-accelerated scission, the effect of simple shear flow (duration and strength) with low Weissenberg and Deborah numbers was investigated by considering the impact of applied work in both simple shear and shear dominated mixed flows. Hydrogenated polyisoprene was chosen as a model linear, entangled system. The conditions (strain amplitude, frequency, and shearing time) necessary to increase chain scission were assessed in the rubbery melt. Shear flow accelerated chain scission at higher temperatures, suggesting an activated process. Isothermal scission versus work curves were superposed by applying shift factors a T,S , whose Arrhenius-like temperature dependence gave an apparent activation energy for chain scission of ~ 110 kJ/mol, which is likely a combination of the activation energy of viscosity and bond energy. This work provides a base for quantifying the impact of shear on depolymerization of polymer melts and highlight the connection between viscous dissipation and scission chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Texas Tech Student Outreach

Giving student outreach presentation covering the basic concepts of linear induction accelerators and how they are applied to the electrical engineering field.

43 PARTICLE ACCELERATORS↗

Metagenome-assembled genomes from Slate River floodplain sediments near Crested Butte, CO, USA (September 2019)

Microorganisms play a key role in cycling nutrients and contaminants in the terrestrial environment depending on their genetic potential. Here we present metagenome-assembled genomes (MAGs) for the bacterial and archaeal community in floodplain sediment samples taken September 2019 at one locations (OBJ1) near the confluence of the Oh-Be-Joyful Creek and Slate River. The site is one of the field sites in focus for the SLAC National Accelerator Laboratory Groundwater Quality Science Focus Area (SFA) program. Sediment samples from a deep soil pit were collected from 50 to 150 cm depth below surface at discrete depths every 20 cm for microbial analyses. A total of 6 metagenomes were sequenced through the Joint Genome Institute (JGI) and can be found under Genomes Online Database (GOLD) sequencing project: Gs0142591. Metagenomes were assembled, binned, and refined using metawrap to generate MAGs (>50% complete and < 10% contamination based on checkM scores). This dataset includes a zip file of 2562 MAG fasta files and a csv file with quality, taxonomic classification (Genome Taxonomy Database Release RS220), and metagenome accessions for MAGs. This dataset also includes a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata and a data dictionary (dd.csv) file that contains column/row headers used throughout the files along with a definition, units, and data type.Part of this work was performed at SLAC Accelerator Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-76SF00515.

54 ENVIRONMENTAL SCIENCES↗