Demand-Side Grid (dsgrid) TEMPO Light-Duty Vehicle Charging Profiles v2022

Simulated hourly electric vehicle charging profiles for light-duty household passenger vehicles in the contiguous United States, 2018-2050. Profiles are differentiated by scenario, county, household and vehicle types, and charging type. Data was produced in 2022 using the Transportation Energy & Mobility Pathway Options (TEMPO) model and published in demand-side grid (dsgrid) toolkit format. Data are available for three adoption scenarios: "AEO Reference Case", which is aligned with the U.S. EIA Annual Energy Outlook 2018 (linked below), "EFS High Electrification", which is aligned with the High Electrification scenario of the Electrification Futures Study (linked below), and "All EV Sales by 2035", which assumes that average passenger light-duty EV sales reach 50% in 2030 and 100% in 2035. The charging shapes are derived from two key assumptions of which data users should be aware: "ubiquitous charger access", meaning that drivers of vehicles are assumed to have access to a charger whenever a trip is not in progress, and "immediate charging", meaning that immediately after trip completion, vehicles are plugged in and charge until they are either fully recharged or taken on another trip. These assumptions result in a bounding case in which vehicles' state of charge is maximized at all times. This bounding case would minimize range anxiety, but is unrealistic from the point of view of both electric vehicle service equipment (EVSE) (i.e., charger) access, and plug-in behavior as it can result in dozens of charging sessions per week for battery electric vehicles (BEVs) that in reality are often only plugged in a few times per week.

Array↗

Identification and Catalysis of the Potential-Limiting Step in Lithium-Sulfur Batteries

The Li-S chemistry is thermodynamically promising for high-density energy storage but kinetically challenging. Over the past few years, many catalyst materials have been developed to improve the performance of Li-S batteries and their catalytic role has been increasingly accepted. However, the classic catalytic behavior, i.e., reduction of reaction barrier, has not been clearly observed. Crucial mechanistic questions, including what specific step is limiting the reaction rate, whether/how it can be catalyzed, and how the catalysis is sustained after the catalyst surface is covered by solid products, remain unanswered. Herein, we report the first identification of the potential-limiting step of Li-S batteries operating under lean electrolyte conditions and its catalysis that conforms to classic catalysis principles, where the catalyst lowers the kinetic barrier of the potential-limiting step and accelerates the reaction without affecting the product composition. After carefully examining the electrochemistry under lean electrolyte conditions, we update the pathway of the Li-S battery reaction: S 8 solid is first reduced to Li 2 S 8 and Li 2 S 4 molecular species sequentially; the following reduction of Li 2 S 4 to a Li 2 S 2 -Li 2 S solid with an almost constant ratio of 1:4 is the potential-limiting step; the previously believed Li 2 S 2 -to-Li 2 S solid-solid conversion does not occur; the recharging reaction is relatively fast. We further demonstrate that supported cobalt phthalocyanine molecules can effectively catalyze the potential-limiting step. After Li 2 S 2 /Li 2 S buries the active sites, it can self-catalyze the reaction and continue driving the discharging process.

25 ENERGY STORAGE↗

A Power Takeoff Device for a Small Marine Hydrokinetic Turbine Deployed from an Unmanned Floating Platform

The design, development, and field-testing of a power takeoff (PTO) device equipped with a ball-type continuously-variable transmission (B-CVT) for a small marine hydrokinetic (MHK) turbine deployed from a floating unmanned autonomous mobile catamaran platform is described. The turbine is a partially-submerged multi-blade undershot waterwheel (USWW). The objective is to develop a PTO for the optimal conversion of the MHK energy harnessed by the turbine to electric power, which is stored in battery banks onboard the MHK platform. Modeling, simulation, and bench testing of the USWW and PTO show the feasibility of utilizing the B-CVT's variable gear ratio to decouple the USWW and generator speeds, maintaining the waterwheel within its optimal tip speed ratio (TSR) while varying the generator speed, thereby increasing the efficiency of the PTO. Results of bench and field testing in support of characterizing the power conversion capabilities of the PTO are described. The system being developed is in support of potential self-powered autonomous mobile recharge stations for unmanned aerial vehicles (U A V s) operating in coastal zones. Field tests of the complete MHK platform with 9 blades on the waterwheel and wheel sub mergences of 10 and 12 inches (full blade submergence) were performed. The overall proof-of-concept was successfully demonstrated, with the system satisfactorily capturing and converting water flow energy into electricity. The feasibility of utilizing the B-CVT as a means of increasing the PTO power capture capabilities and efficiency is analyzed.

Pimentel, Hugo↗

Resolving Current-Dependent Regimes of Electroplating Mechanisms for Fast Charging Lithium Metal Anodes

Poor fast-charge capabilities limit the usage of rechargeable Li metal anodes. Understanding the connection between charging rate, electroplating mechanism, and Li morphology could enable fast-charging solutions. In this report we develop a combined electroanalytical and nanoscale characterization approach to resolve the current-dependent regimes of Li plating mechanisms and morphology. Measurement of Li + transport through the solid electrolyte interphase (SEI) shows that low currents induce plating at buried Li||SEI interfaces, but high currents initiate SEI-breakdown and plating at fresh Li||electrolyte interfaces. The latter pathway can induce uniform growth of {110}-faceted Li at extremely high currents, suggesting ion-transport limitations alone are insufficient to predict Li morphology. At battery relevant fast-charging rates, SEI-breakdown above a critical current density produces detrimental morphology and poor cyclability. Thus, prevention of both SEI-breakdown and slow ion-transport in the electrolyte is essential. This mechanistic insight can inform further electrolyte engineering and customization of fast-charging protocols for Li metal batteries.

25 ENERGY STORAGE↗

Federal Workplace Charging Program Guide

The 2015 Fixing America's Surface Transportation (FAST) Act authorizes the installation, operation, and maintenance of electric vehicle supply equipment (EVSE) for the purpose of recharging employees' privately owned vehicles (POVs) under the custody or control of the General Services Administration (GSA) or a Federal agency. It requires the collection of fees to recover the costs of installing, operating, and maintaining this equipment and imposes reporting requirements. This program guide reviews those requirements, excerpts the relevant language in Appendix A, and describes when and how fees may be required to cover costs of electricity, network costs, EVSE units, and installations in various scenarios. This program guide is designed to support Federal agencies developing and refining workplace charging programs for employee POVs. While it provides guidance and best practices, it does not replace agencywide policies or agency-specific legal counsel. It contains a roadmap for agency workplace charging programs and defines roles and responsibilities. This guide explains how to determine the number of POVs likely to charge at a given site and contains a sample employee survey in Appendix B. It reviews EVSE planning, including unit selection and acquisition, charger location(s), accounting for available power capacity, using existing infrastructure, and funding an incentive program. It also discusses the costs associated with EVSE acquisition, installation, and network management. These costs inform the subsequently provided information, which describes how to amortize costs to determine appropriate fees for each charging session. The final two sections of this guide address aspects of ongoing program management that the facility coordinator should consider and the reporting requirements associated with the FAST Act. The insights in this guide are applicable to all agency-owned and GSA-leased buildings or facilities offering the use of EVSE or a 120-volt receptacle for the purpose of recharging an employee's POV. However, the FAST Act requirements typically do not apply to any building or facility operated and maintained by a third-party vendor offering the use of EVSE as part of a commercial building lease unless the agency is managing the station and/or energy on behalf of the building and collecting POV fees.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design Considerations for Fast Charging Lithium Ion Cells for NMC/MCMB Electrode Pairs

Lithium ion cells that can be quickly charged are of critical importance for the continued and accelerated penetration of electric vehicles (EV) into the consumer market. Considering this, the U.S. Department of Energy (DOE) has set a cell recharge time goal of 10–15 min. The following study provides an investigation into the effect of cell design, specifically negative to positive matching ratio (1.2:1 vs. 1.7:1) on fast charging performance. By using specific charging procedures based on negative electrode performance, as opposed to the industrial standard constant current constant voltage procedures, we show that the cells with a higher N:P ratio can be charged to ~16% higher capacity in the ten-minute time frame. Cells with a higher N:P ratio also show similar cycle life performance to those with a conventional N:P ratio, despite the fact that these cells experience a much higher irreversible capacity loss, leading to a lower reversible specific capacity.

25 ENERGY STORAGE↗

Hidden figures of photo-charging: a thermo-electrochemical approach for a solar-rechargeable redox flow cell system

Achieving high current densities without thermal performance degradation at high temperatures is one of the main challenges for enhancing the competitiveness of photo-electrochemical energy storage systems. We describe a system that overcomes this challenge by incorporating an integrated photoelectrode with a redox flow cell, which functions as a coolant for the excess heat from the photo-absorber. We perform quantitative analyses to theoretically validate and highlight the merit of the system. Practical operation parameters, including daily temperature and redox reaction kinetics, are modeled with respect to heat and charge transfer mechanisms. Our analyses show a profound impact on the resulting solar-to-chemical efficiencies and stored power, which are 21.8% higher than that of a conventional photovoltaic-assisted energy storage system. This paves the way for reassessing the merit of photovoltaic-integrated systems, which have hitherto been underrated as renewable energy storage systems.

25 ENERGY STORAGE↗

Powering the Blue Economy: A Survey of Station-Keeping Methods for Mooringless Platforms

The term “ocean platform” is used to reference everything from stationary, typically moored, buoys to mobile water vehicles, whether they operate on the ocean’s surface or underwater. For certain applications for which relatively stationary station-keeping conditions are desired, the use of mooring systems is not always a viable alternative either for economic, environmental, regulatory, or otherwise practical reasons, or a combination thereof, (e.g., short deployments, sensitive ecosystems, very deep project sites). Maintaining a platform at a single waypoint or reference location without being moored would require additional control systems and a power source to counteract the drift forces that would naturally displace it. Mobile platforms, which are usually untethered except for remotely operated vehicles, typically require energy input to power their station-keeping capabilities so that they hold or control their location in the ocean. Currently, most of these platforms use combustion engines or batteries for this purpose, which, depending on the specific systems, may be costly, pollute the environment, or create limitations on the length of the deployment. However, powering this kind of platforms with surrounding renewable resources (waves, currents, winds, or sun) has been identified as a promising solution to expand their application. The intent of this report is to investigate station-keeping methods for various ocean platforms that are not moored or otherwise anchored to the ocean floor, or another platform or vessel, paying particular interest to technologies that use marine renewable resources to power their operation, because that is of particular interest to the U.S. Department of Energy’s Powering the Blue Economy (PBE) initiative. As a first step, 72 articles and technical reports related to mooringless station-keeping methods were collected for review. The preliminary literature review provided a broad overview of common themes across the literature from which a descriptive methodology for analyzing various platforms was developed. That is, station-keeping methods were categorized based on their predominant energy source and consumption (renewable, nonrenewable, or hybrid if the platform uses renewable and nonrenewable resources equally), and their localization strategy (drift reduction, “path-planning or “waypoint-holding”). In addition, platform types were segregated into the following groups: buoys, surface drifters, and unoccupied surface vehicles (USVs); offshore renewable energy systems; and unoccupied underwater vehicles (UUVs). The main types of station-keeping methods encountered in this report achieve their intended localization strategy by means of drift mitigation, steering, and/or propulsion. Drift mitigation is commonly accomplished via drogues and sea anchors. Stand-along steering subsystems use control surfaces (e.g., ship rudder, wing sail, etc.) that react to ocean currents, waves, or winds to provide varying-degrees of course adjustments. Combined steering and propulsion subsystems include differential thrusters, directional thrusters separate from a primary thruster that cause the platform to pitch up/down or yaw clockwise/counterclockwise, or vectored thrusters that direct the propulsion in a range of directions relative to the platform’s local coordinate system. Propulsion is often achieved by running a motor and applying active control strategies but can also involve buoyancy shifts and using sails to generate lifting forces that propel a platform in a desired direction. Future research is primarily expected to take place in the form of a technoeconomic analysis that would aim to determine the technological viability, cost, and added value of mooringless station-keeping use cases identified through this research, including docking for UUV recharging or for georeferencing drifter buoys, deep-sea floating wind farms, U.S. Navy sonar arrays, and a Pacific Ocean wave buoy network.