Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescence Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Aperiodic reflection diffraction gratings for soft X-ray radiation and their application

We briefly review the works concerned with the development and experimental use of the spectral instruments based on aperiodic reflection gratings whose spacing varies monotonically across the aperture according to a prescribed law (VLS gratings). The review considers the employment of VLS-grating instruments intended for the spectroscopy of laboratory and astrophysical plasmas, including the diagnostics of relativistic laser plasmas, for measuring X-ray laser linewidths, for recording the high-order harmonics of laser radiation, the radiation of fast electric discharges and other laboratory X-ray sources, as well as in reflectometry, X-ray fluorescence analysis and microscopy with the use of synchrotron radiation and laser-plasma radiation, and in emission spectroscopy combined with an electron microscope. Also discussed are achievements in the recently undertaken design and development of special-purpose VLS spectrometers intended for the investigation of the electronic structure of different materials and molecules by the spectroscopic technique of resonant inelastic X-ray scattering of synchrotron radiation. We describe flat-field grazing-incidence spectrometers with concave VLS gratings, which are compatible with modern CCD detectors, as well as plane VLS gratings, which are the key elements of scanning high- and ultrahigh-resolution spectrometers/monochromators with a constant deviation angle and stigmatic (imaging) spectrometers, which are also compatible with CCD detectors. (paper)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solid Collection Efforts: Ta Collimator Evaluation

Ta collimator sets that were part of the gated x-ray detector diagnostic (GXD) at NIF were analyzed for debris distribution and damage in 2011. These disks (ranging in thickness from 250 to 750 {mu}m) were fielded approximately 10 cm from target chamber center (TCC) on various symcap, THD and re-emit shots. The nose cone holder and forward Ta collimator (facing target chamber center, TCC) from all shots show evidence of surface melt. Non-destructive analysis techniques such as optical microscopy, surface profilometry, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and x-ray fluorescence (XRF) were used to determine debris composition and degree of deformation associated with each Ta disk. Molten debris from the stainless steel nose cone contaminated the surface of the collimators along with other debris associated with the target assembly (Al, Si, Cu, Au and In). Surface elemental analysis of the forward collimator Ta disks indicates that Au hohlraum debris is less concentrated on these samples versus those fielded 50 cm from TCC in the wedge range filter (WRF) assembly. It is possible that the Au is distributed below or within the stainless steel melt layer covering the disk, as most of the foreign debris is captured in the melted coating. The other disks (fielded directly behind the forward collimator in a sandwiched configuration) have visible forms of deformation and warping. The degree of warping increases as the shock wave penetrates the assembly with the most damage sustained on the back collimator. In terms of developing a solid collection capability, the collimator analyses suggests that close proximity may cause more interference with capsule debris collection and more damage to the surface of the collector diagnostic. The analyses of the Ta collimators were presented to the Target and Laser Interaction Sphere (TaLIS) group; a representative presentation is attached to this document.

36 MATERIALS SCIENCE↗

Localization of fluorescent targets in deep tissue with expanded beam illumination for studies of cancer and the brain

Imaging fluorescence through millimeters or centimeters of tissue has important in vivo applications, such as guiding surgery and studying the brain. Often, the important information is the location of one of more optical reporters, rather than the specifics of the local geometry, motivating the need for a localization method that provides this information. We present an optimization approach based on a diffusion model for the fast localization of fluorescent inhomogeneities in deep tissue with expanded beam illumination that simplifies the experiment and the reconstruction. We show that the position of a fluorescent inhomogeneity can be estimated while assuming homogeneous tissue parameters and without having to model the excitation profile, reducing the computational burden and improving the utility of the method. We perform two experiments as a demonstration. First, a tumor in a mouse is localized using a near infrared folate-targeted fluorescent agent (OTL38). This result shows that localization can quickly provide tumor depth information, which could reduce damage to healthy tissue during fluorescence-guided surgery. Second, another near infrared fluorescent agent (ATTO647N) is injected into the brain of a rat, and localized through the intact skull and surface tissue. This result will enable studies of protein aggregation and neuron signaling.

60 APPLIED LIFE SCIENCES↗

Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

Instrument Development: The membrane properties were investigated in detail due to its critical role. A series of experiments determined that our designed membranes have high electron transmission, yet are capable of isolating high vacuum, are able to withstand differential pressure in excess of one atmosphere, survive vibrational shocks of a magnitude to be expected during a planetary mission. Our initial work has been with a 10 keV source and a 200 nm thick Silicon Nitride (SiN) encapsulation membrane micro-fabricated within a Si support frame (1.5 mm x 1.5 mm window openings. Fig 2 compares the spectra taken with the 10 keV source with spectra taken within SEM. Introduction: This paper describes the progress in the development of the AEXS instrument in our laboratory at JPL. The AEXS is a novel miniature instrument[1-3] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam, for non-destructive evaluation of surfaces of samples in planetary ambient atmosphere. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum within the AEXS electron source from the outside ambient atmosphere. The impinging electrons excite XRF spectra from the irradiated spots on samples in external atmosphere with high-to-medium (sub-mm to cm-scale) spatial resolution at Mars atmospheric pressure. The XRF spectra are analyzed using an energy-dispersive detector to determine surface elemental composition, or in the case of electron-induced luminescence to identify unusual formations on surface that cathodo-luminescence (CL). The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an EDX detection and analyzer system to determine the elemental abundance, an optional CL detection system, and a high voltage power supply. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the viability of micro-fabricated membranes, 2) assembling AEXS setups with increasingly integrated functional components, and 3) simulating the AEXS observational capabilities. This paper will focus on description of the development of the instrument.

Wilcox, J. Z.↗

Nuclear photonics

With the planned new {gamma}-beam facilities like MEGa-ray at LLNL (USA) or ELI-NP at Bucharest (Romania) with 10{sup 13}{gamma}/s and a band width of {Delta}E{gamma}/E{gamma} Almost-Equal-To 10{sup -3}, a new era of {gamma} beams with energies up to 20MeV comes into operation, compared to the present world-leading HI{gamma}S facility at Duke University (USA) with 10{sup 8}{gamma}/s and {Delta}E{gamma}/E{gamma} Almost-Equal-To 3 Dot-Operator 10{sup -2}. In the long run even a seeded quantum FEL for {gamma} beams may become possible, with much higher brilliance and spectral flux. At the same time new exciting possibilities open up for focused {gamma} beams. Here we describe a new experiment at the {gamma} beam of the ILL reactor (Grenoble, France), where we observed for the first time that the index of refraction for {gamma} beams is determined by virtual pair creation. Using a combination of refractive and reflective optics, efficient monochromators for {gamma} beams are being developed. Thus, we have to optimize the total system: the {gamma}-beam facility, the {gamma}-beam optics and {gamma} detectors. We can trade {gamma} intensity for band width, going down to {Delta}E{gamma}/E{gamma} Almost-Equal-To 10{sup -6} and address individual nuclear levels. The term 'nuclear photonics' stresses the importance of nuclear applications. We can address with {gamma}-beams individual nuclear isotopes and not just elements like with X-ray beams. Compared to X rays, {gamma} beams can penetrate much deeper into big samples like radioactive waste barrels, motors or batteries. We can perform tomography and microscopy studies by focusing down to {mu}m resolution using Nuclear Resonance Fluorescence (NRF) for detection with eV resolution and high spatial resolution at the same time. We discuss the dominating M1 and E1 excitations like the scissors mode, two-phonon quadrupole octupole excitations, pygmy dipole excitations or giant dipole excitations under the new facet of applications. We find many new applications in biomedicine, green energy, radioactive waste management or homeland security. Also more brilliant secondary beams of neutrons and positrons can be produced.

43 PARTICLE ACCELERATORS↗

Hyperspectral X-ray Imaging with TES Detectors for Nanoscale Chemical Speciation Mapping

We are developing an imaging capability (“Hyperspectral X-ray Imaging”) for mapping chemical information (molecular formula, phase, oxidation state, hydration) that is based on ultra-high-resolution X-ray emission spectroscopy with large transition-edge sensor microcalorimeter arrays in the scanning electron microscope. By combining microcalorimeter arrays with hundreds of pixels, high-bandwidth microwave frequency-division multiplexing, and fast digital electronics for near real-time data processing, our goal is to enable measurements using laboratory-scale instrumentation rather than synchrotron beamlines. Our application focus here is on mapping the chemical form of uranium compounds on the nanoscale. Furthermore, we will present our approach to developing the Hyperspectral X-ray Imaging capability, progress toward a 128-pixel microwave multiplexed X-ray fluorescence instrument at LANL, and the path to high-throughput nanoscale chemical mapping.

47 OTHER INSTRUMENTATION↗

ISS Ammonia Leak Detection Through X-Ray Fluorescence

Ammonia leaks are a significant concern for the International Space Station (ISS). The ISS has external transport lines that direct liquid ammonia to radiator panels where the ammonia is cooled and then brought back to thermal control units. These transport lines and radiator panels are subject to stress from micrometeorites and temperature variations, and have developed small leaks. The ISS can accommodate these leaks at their present rate, but if the rate increased by a factor of ten, it could potentially deplete the ammonia supply and impact the proper functioning of the ISS thermal control system, causing a serious safety risk. A proposed ISS astrophysics instrument, the Lobster X-Ray Monitor, can be used to detect and localize ISS ammonia leaks. Based on the optical design of the eye of its namesake crustacean, the Lobster detector gives simultaneously large field of view and good position resolution. The leak detection principle is that the nitrogen in the leaking ammonia will be ionized by X-rays from the Sun, and then emit its own characteristic Xray signal. The Lobster instrument, nominally facing zenith for its astrophysics observations, can be periodically pointed towards the ISS radiator panels and some sections of the transport lines to detect and localize the characteristic X-rays from the ammonia leaks. Another possibility is to use the ISS robot arm to grab the Lobster instrument and scan it across the transport lines and radiator panels. In this case the leak detection can be made more sensitive by including a focused 100-microampere electron beam to stimulate X-ray emission from the leaking nitrogen. Laboratory studies have shown that either approach can be used to locate ammonia leaks at the level of 0.1 kg/day, a threshold rate of concern for the ISS. The Lobster instrument uses two main components: (1) a microchannel plate optic (also known as a Lobster optic) that focuses the X-rays and directs them to the focal plane, and (2) a CCD (charge coupled device) focal plane detector that reads out the position and energy of the X-rays, allowing a determination of the leak location. The effective area of the detection system is approximately 2 cm(exp2) at 1 keV. The Lobster astrophysics instrument, designed for monitoring the sky for Xray transients, gives high sensitivity along with large field of view (30×30deg) and good spatial resolution (1 arc min). This offers a significant benefit for detecting ISS ammonia leaks, since the goal is to localize small leaks as efficiently as possible.

Camp, Jordan↗

Scanless laser waveform measurement in the near-infrared

Field-resolved measurements of few-cycle laser waveforms allow access to ultrafast electron dynamics in light–matter interactions and are key to future lightwave electronics. Recently, sub-cycle gating based on nonlinear excitation in active pixel sensors has allowed the first single-shot measurements of mid-infrared optical fields. Extending the techniques to shorter wavelengths, however, is not feasible using silicon-based detectors with bandgaps in the near-infrared. Here, we demonstrate an all-optical sampling technique for near-infrared laser fields, wherein an intense fundamental field generates a sub-cycle gate through nonlinear excitation of a wide-bandgap crystal, in this case, ZnO, which can sample the electric field of a weak perturbing pulse. By using a crossed-beam geometry, the temporal evolution of the perturbing field is mapped onto a transverse spatial axis of the nonlinear medium, and the waveform is captured in a single measurement of the spatially resolved fluorescence emission from the crystal. The technique is demonstrated through field-resolved measurements of the field reshaping during nonlinear propagation in the ZnO detection crystal.

Truong, Tran-Chau (ORCID:0000000348940635)↗

Lunar and Planetary Science XXXV: Astrobiology

The presentations in this session are: 1. A Prototype Life Detection Chip 2. The Geology of Atlantis Basin, Mars, and Its Astrobiological Interest 3. Collecting Bacteria Together with Aerosols in the Martian Atmosphere by the FOELDIX Experimental Instrument Developed with a Nutrient Detector Pattern: Model Measurements of Effectivity 4. 2D and 3D X-ray Imaging of Microorganisms in Meteorites Using Complexity Analysis to Distinguish Field Images of Stromatoloids from Surrounding Rock Matrix in 3.45 Ga Strelley Pool Chert, Western Australia 4. Characterization of Two Isolates from Andean Lakes in Bolivia Short Time Scale Evolution of Microbiolites in Rapidly Receding Altiplanic Lakes: Learning How to Recognize Changing Signatures of Life 5. The Effect of Salts on Electrospray Ionization of Amino Acids in the Negative Mode 6. Determination of Aromatic Ring Number Using Multi-Channel Deep UV Native Fluorescence 7. Microbial D/H Fractionation in Extraterrestrial Materials: Application to Micrometeorites and Mars 8. Carbon Isotope Characteristics of Spring-fed Iron-precipitating Microbial Mats 9. Amino Acid Survival Under Ambient Martian Surface UV Lighting Extraction of Organic Molecules from Terrestrial Material: Quantitative Yields from Heat and Water Extractions 10. Laboratory Detection and Analysis of Organic Compounds in Rocks Using HPLC and XRD Methods 11. Thermal Decomposition of Siderite-Pyrite Assemblages: Implications for Sulfide Mineralogy in Martian Meteorite ALH84001 Carbonate Globules 12. Determination of the Three-Dimensional Morphology of ALH84001 and Biogenic MV-1 Magnetite: Comparison of Results from Electron Tomography and Classical Transmission Electron Microscopy 13. On the Possibility of a Crypto-Biotic Crust on Mars Based on Northern and Southern Ringed Polar Dune Spots 14. Comparative Planetology of the Terrestrial Inner Planets: Implications for Astrobiology 15. A Possible Europa Exobiology 16. A Possible Biogeochemical Model for Titan

Source record↗

A Sensitive Quantitative Analysis of Abiotically Synthesized Short Homopeptides using Ultraperformance Liquid Chromatography and Time-of-Flight Mass Spectrometry

In the origins of life field understanding the abiotic polymerization of simple organic monomers (e.g., amino acids) into larger biomolecules (e.g., oligopeptides), remains a seminal challenge. Recently, preliminary observations showed a limited set of peptides formed in the presence of the plausible prebiotic phosphorylating agent, diamidophosphate (DAP), highlighting the need for an analytical tool to critically evaluate the ability of DAP to induce oligomerization of simple organics under aqueous conditions. However, performing accurate and precise, targeted analyses of short oligopeptides remains a distinct challenge in the analytical chemistry field. Here, we developed a new technique to detect and quantitate amino acids and their homopeptides in a single run using ultraperformance liquid chromatography-fluorescence detection/time of flight mass spectrometry. Over an 8-minute retention time window, 18 target analytes were identified and quantitated, 16 of which were chromatographically separated at, or near baseline resolution. Compound identity was confirmed by accurate mass analysis using a 10 ppm mass tolerance window. This method featured limits of detection < 5 nM (< 1 fmol on column) and limits of quantitation (LOQs) <15 nM (< 3 fmol on column). The LODs and LOQs were upwards of ∼28x and ∼788x lower, respectively, than previous methods for the same analytes, highlighting the quantifiable advantages of this new method. Both detectors provided good quantitative linearity (R(exp 2) > 0.985) for all analytes spanning concentration ranges ∼3 - 4 orders of magnitude. We performed a series of laboratory experiments to investigate DAP-mediated oligomerization of amino acids and peptides and analyzed experimental products with the new method. DAP readily polymerized amino acids and peptides under a range of simulated environmental conditions. This research underscores the potential of DAP to have generated oligopeptides on the primordial Earth, enhancing prebiotic chemical diversity and complexity at or near the origin of life.

Prebiotic Chemistry and Analytical Chemistry↗

Development of two-channel prototype ITER vacuum ultraviolet spectrometer with back-illuminated charge-coupled device and microchannel plate detectors

A vacuum ultraviolet (VUV) spectrometer of a five-channel spectral system is designed for ITER main plasma impurity measurement. To develop and verify the system design, a two-channel prototype system is fabricated with No. 3 (14.4-31.8 nm) and No. 4 (29.0-60.0 nm) among the five channels. The optical system consists of a collimating mirror to collect the light from source to slit, two holographic diffraction gratings with toroidal geometry, and two different electronic detectors. For the test of the prototype system, a hollow cathode lamp is used as a light source. To find the appropriate detector for ITER VUV system, two kinds of detectors of the back-illuminated charge-coupled device and the microchannel plate electron multiplier are tested, and their performance has been investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Warm Electron Beam Ion Trap (WEBIT): An instrument for ground calibration of space-borne x-ray spectrometers

The warm electron beam ion trap (WEBIT) at Lawrence Livermore National Laboratory is being developed as a pre-launch, ground calibration source for space-borne, high-throughput, high-resolution x-ray spectrometers, such as the x-ray imaging and spectroscopy mission Resolve quantum calorimeter. Historically, calibration sources for calorimeter spectrometers have relied on characteristic line emission from x-ray tubes, fluorescing metals, and radioactive sources. The WEBIT, by contrast, relies on emission from x-ray transitions in highly charged ions, for example, hydrogen-like and helium-like ions, whose energies are well known and whose line shapes are relatively simple. The WEBIT can create astrophysically relevant ions whose x-ray emission falls in the 0.3-12 keV science bandpass of Resolve and has a portable design advantageous for a calibration source. The WEBIT will be used to help calibrate Resolve’s instrumental line shape and gain scale as a function of various operational parameters during both detector subsystem level testing and instrumental level testing.

47 OTHER INSTRUMENTATION↗

Development of ultra-pure gadolinium sulfate for the Super-Kamiokande gadolinium project

This paper reports the development and detailed properties of about 13 metric tons of gadolinium sulfate octahydrate, Gd 2 (SO 4 ) 3 • 8H 2 O⁠, which has been dissolved into Super-Kamiokande (SK) in the summer of 2020. We evaluate the impact of radioactive impurities in Gd 2 (SO 4 ) 3 • 8H 2 O on diffuse supernova neutrino background searches and solar neutrino observation and confirm the need to reduce radioactive and fluorescent impurities by about three orders of magnitude from commercially available high-purity Gd 2 (SO 4 ) 3 • 8H 2 O⁠. In order to produce ultra-high-purity Gd 2 (SO 4 ) 3 • 8H 2 O, we have developed a method to remove impurities from gadolinium oxide, Gd 2 O 3 , consisting of acid dissolution, solvent extraction, and pH control processes, followed by a high-purity sulfation process. All of the produced ultra-high-purity Gd 2 (SO 4 ) 3 • 8H 2 O is assayed by inductively coupled plasma mass spectrometry and high-purity germanium detectors to evaluate its quality. Because of the long measurement time of high-purity germanium detectors, we have employed several underground laboratories for making parallel measurements including the Laboratorio Subterráneo de Canfranc in Spain, Boulby in the UK, and Kamioka in Japan. In the first half of production, the measured batch purities were found to be consistent with the specifications. However, in the latter half, the Gd 2 (SO 4 ) 3 • 8H 2 O contained one order of magnitude more 228Ra than the budgeted mean contamination. This was correlated with the corresponding characteristics of the raw material Gd 2 O 3 , in which an intrinsically large contamination was present. Based on their modest impact on SK physics, they were nevertheless introduced into the detector. To reduce 228 Ra for the next stage of gadolinium loading to SK, a new process has been successfully established.

79 ASTRONOMY AND ASTROPHYSICS↗

Controlled Shifts of X-ray Emission Lines Measured with Transition Edge Sensors at the Advanced Photon Source

The measurement of shifts in the energy of X-ray emission lines is important for understanding the electronic structure and physical properties of materials. In this study, we demonstrate a method using a synchrotron source to introduce controlled eV-scale shifts of a narrow line in between fixed-energy fluorescence lines. We use this to characterize the ability of a hard X-ray superconducting Transition Edge Sensor (TES) array to measure line shifts. Fixed fluorescence lines excited by higher harmonics of the monochromatic X-ray beam are used for online energy calibration, while elastic scattering from the primary harmonic acts as the variable energy emission line under study. We use this method to demonstrate the ability to track shifts in the energy of the elastic scattering line of magnitude smaller than the TES energy resolution, and find we are ultimately limited by our calibration procedure. The method can be applied over a wide X-ray energy range and provides a robust approach for the characterization of the ability of high-resolution detectors to detect X-ray emission line shifts, and the quantitative comparison of energy calibration procedures.

Guruswamy, Tejas (ORCID:0000000241656765)↗

Translimb Spectroscopy with SOHO/SUMER

We have used SUMER to obtain deep exposures of the 1300-1400 A spectrum, at the extreme limb and off-limb. Previous "translimb" studies in the thermal infrared had revealed remarkable extensions of cold material (T approximately 3000 K)--traced by carbon monoxide emission lines--into the heart of the hot chromosphere. A main objective of our program was to search for corresponding far-UV signatures of the "thermally-bifurcated" low chromosphere; for example, radiatively fluoresced emissions of the CO A-X 4th-positive system (collisional excitation would be negligible in cold gas). We conducted two separate observing programs with SUMER. Both made use of the 1"-diameter circular aperture, translated across the limb in the minimum motor step increments of 0.375", along the central meridian in the Northern polar coronal hole. The first program executed for nine hours beginning 19UT 25 Oct 1996. The full wavelength range was 1340-1400 A. It was recorded in two overlapping segments, placing key regions of the spectrum alternately on the KBr and bare parts of the detector, to help isolate 2nd-order features. Each segment was integrated for 500 s, and 32 pairs were obtained to span a 12" swath centered on the optical limb. The second program was conducted 00-09UT 01 Dec 1996. It consisted of a single wavelength setting (1300-1340 A) with exposure time 500 s, but twice the spatial coverage of the earlier series: 64 steps, for a total displacement of 24". The strong chromospheric resonance lines of atomic oxygen (1302-1305 A) and ionized carbon (1334-1335 A) were observed on the bare part of the MCP camera. We report our progress in cataloging the rich, diverse translimb emission spectrum; and our efforts to deduce fundamental properties of the thermally heterogeneous chromosphere.

Ayer, Thomas R.↗

Achieving clean production with nanostructured coated milling tools dry machining low carbon steel

The advancement of clean production using nanostructured materials in subtractive manufacturing processes has focused on replacing the use of liquid lubrication with solid lubricants coated to conventional cutting tools machining low carbon steel (~ 0.2 wt. % carbon). However, little is known about the wear mechanisms that dominate such tools when coated with functional graded nanostructured coatings. The present study follows an international standard for characterizing such wear (ISO 8688) but uses advanced measurement techniques such as x-ray fluorescence technology to measure the diffusion of chemical species from tool to workpiece and vice versa, that contributes to tool wear with the view to enhance the principles of cleaner production. The results show that when commercially-available tools coated with the appropriate functionally graded industrial coating, diffusion does not take place and creates an effective chemical barrier during machining. The experimental methods used in the study include machining workpieces using a CNC milling machine, tachometer for measuring spindle speed, dynamometer for measuring cutting forces, infra-red camera for measuring cutting temperatures, chemical species diffusion wear using x-ray florescence detector, and an optical microscope for measuring tool wear. Coupled with the physical measurement of wear, it is concluded that mechanical wear dominates the milling of a low carbon steel and that thermal properties of the coatings do not correlate with such wear. It is also concluded that flank wear as a function of volume of workpiece removed and machining duration (machining index) is a sound method for assessing the transition of the stages of wear during clean machining operations. The present study not only has implication for the design of better cutting tools, but also advances dry machining processes that eliminate the use of liquid lubricants making subtractive production processes cleaner. The main conclusions drawn from this study show that coated tools have a longer life under dry conditions compared to uncoated tools and that there is no correlation between coating properties and tool wear. In conclusion, diffusion of chemical species into the cut chips did not occur because of the lack of thermally induced chemical wear of the cutting tool and that wear is caused by the gradual erosion of the flank face due to the chip abrading the cutting tool.

36 MATERIALS SCIENCE↗

The Solar-Stellar Connection (NAG5-6124: SOHO Guest Investigator Program)

The following is a final report from the SOHO Guest Investigator program to use the SUMER far-UV spectrometer to obtain imaging spectroscopy in support of the goals of the so-called "solar-stellar connection." In particular, a major emphasis was utilization of the long-slit time-resolved maps of the solar surface in bright far-UV emission lines to deduce how particular aspects of the temporally and spatially averaged line profiles trace back to individual structural features of the magnetically disturbed outer atmosphere; to help interpret the unresolved line profiles from high quality stellar observations (say, with the Space Telescope Imaging Spectrograph). The researchers served two tours of duty in the SOHO Operations Center as SUMER planners, during which time we conducted an extensive series of observing programs. These can be divided into three general categories: surface mapping, translimb spectroscopy, and active region diagnostics. We have analyzed some of the large volumes of data to the point where we have presented them in poster papers, and in invited papers at national and international meetings. Listed below are the titles of the preliminary publications we have written, including brief abstracts to indicate the main results. (1) Chromospheric structure and Dynamics-- Observations -- The chromosphere is a highly structured dynamic 'layer' of the solar outer atmosphere. Here, not only are the effects of mechanical heating first evident (moving upward in altitude from the deep photosphere), but also the amount of nonradiative energy deposited is far greater than in the albeit much hotter overlying transition region and corona. Further, the chromosphere is by far the thickest zone of the solar atmosphere with respect to the pressure scale height. A major goal of stellar astrophysics is to understand how the chromosphere is heated and why it adopts its peculiar structure. A cursory examination of solar filtergrams and high-resolution movies demonstrates that much of the chromospheric "action" must be occurring on fine spatial scales and short times; particularly in the cell interior transient brightenings, but also in the longer-lived network fragments. That regime of investigation is far removed from what one usually associates with "synoptic" measurements. Nevertheless, synoptic observations of chromospheric indices, filtergrams, and globally-averaged profile parameters not only can provide important insight concerning the crucial role of the cycle-variable part of the solar magnetic field; but they also can forge a key link with analogous measurements of the stars, where often the phenomena can be significantly exaggerated from the solar case, but high spatial resolution reconnaissance is not even a remote possibility. In addition to discussing the synoptic aspects of chromospheric structure and dynamics, I summarized new insights into the general problem of the solar chromosphere that have been obtained recently with the SUMER far-ultraviolet spectrometer on SOHO. (2) CO and the Temperature Structure of the Solar Atmosphere -- The surface layers of the Sun provide a crucial boundary condition for many of the processes that occur in the deep interior. The stratification of the outer solar atmosphere once was thought to be well understood. However, studies of thermally sensitive molecular absorptions in the infrared revealed puzzling anomalies. Strong lines of the CO fundamental vibration-rotation bands near 5 microns showed very cool temperatures at the extreme limb, and remarkable off-limb emissions extending well into the supposedly hot chromosphere. The conflicting pictures of the photosphere/chromosphere interface, from the widely separated wavelength regimes, has raised suspicions that those "layers" of the atmosphere are much more inhomogeneous than previously suspected. One proposal is that the low chromosphere is dominated by cool gas, the "COmosphere," which is threaded by a network of persistent small-scale hot magnetic filaments and occasionally disrupted by localized acoustic disturbances. The COmosphere is capped by the merged fields of the network elements in the chromospheric "canopy." (3) Translimb Spectroscopy with SOHO/SUMER -- We have used SUMER to obtain deep exposures of the 1300-1400 A spectrum, at the extreme limb and off-limb. Previous "translimb" studies in the thermal infrared had revealed remarkable extensions of cold material (T is approximately equal to 3000 K)-traced by carbon monoxide emission lines-into the heart of the hot chromosphere. A main objective of our program was to search for corresponding far-UV signatures of the "thermally-bifurcated" low chromosphere; for example, radiatively fluoresced emissions of the CO A-X 4th-positive system (collisional excitation would be negligible in cold gas). We conducted two separate observing programs with SUMER. Both made use of the 1 inch-diameter circular aperture, translated across the limb in the minimum motor step increments of 0."375, along the central meridian in the Northern polar coronal hole. The first program executed for nine hours beginning 19UT 25 Oct 1996. The full wavelength range was 1340-1400 A. It was recorded in two overlapping segments, placing key regions of the spectrum alternately on the KBr and bare parts of the detector, to help isolate 2nd-order features. Each segment was integrated for 500 s, and 32 pairs were obtained to span a 12" swath centered on the optical limb. The second program was conducted 00-09UT 01 Dec 1996. It consisted of a single wavelength setting (1300-1340 A) with exposure time 500 s, but twice the spatial coverage of the earlier series: 64 steps, for a total displacement of 24". The strong chromospheric resonance lines of atomic oxygen (1302-1305 A) and ionized carbon (1334-1335 A) were observed on the bare part of the MCP camera.

Ayres, Thomas R.↗

Case Studies on Facility Characterization with X-Ray Fluorescence Spectrometry

A hand-held x-ray fluorescence (XRF) analyzer is being used to characterize facilities in support of demolition activities at the East Tennessee Technology Park (ETTP) in Oak Ridge, Tennessee. Approximately 500 facilities at the U.S. Department of Energy site are being demolished under the ETTP Decontamination and Decommissioning (D and D) project. Facility characterization is being conducted to provide data for waste profiling and identify hazards to demolition workers. XRF spectrometry is a non-destructive analytical technique used to identify and quantify the elemental composition of a substance based on the intensity of its characteristic X-ray emission wavelength or energy. The Innov-X Systems{sup R} Model XT-245S XRF analyzer used at ETTP is equipped with a silver anode x-ray tube and a Si PIN diode detector. X-rays are generated by electrical current, eliminating the need for radioactive isotopes. Electronic components can be powered by either a lithium-ion battery or an A/C adapter, and the instrument is controlled by an iPAQ{sup R} pocket personal computer. The unit has two primary operating modes. Alloy analysis mode measures percent levels of elements in metals such as a pipes, valves, equipment, or construction materials. Soil mode provides parts-per-million (ppm) quantities in bulk solids like concrete dust, residue, paint chips, or soil. The hand-held unit can analyze material in place, or it can analyze samples in a test stand by remote operation. This paper present some case studies demonstrating a variety of XRF applications for facility characterization: Metal Materials Characterization, Lead Paint Identification, Hot Spot Delineation, Bulk Solids Testing. XRF has been the analytical technique of choice for identifying metal alloy components and has also been useful in analyzing bulk materials. Limitations of XRF testing include the inability to directly analyze elements with low atomic weights. Light elements such as beryllium and aluminum do not emit characteristic x-rays that the instrument can detect. However, process knowledge and existing historical data can be used to evaluate the presence of beryllium, which has been widely characterized at ETTP using industrial hygiene smear samples. Aluminum can be indirectly measured in aluminum alloys using x-ray scatter lines. The Innov-X Systems XRF has a light elements setting that employs this method, and it has been widely used on the ETTP D and D project. Another potential limitation involves analyzing samples that are radioactive, or analyzing samples in a radioactive environment. Radiation (including gamma, beta, and high energy alpha particles) acts as another excitation mechanism to create x-rays from materials being analyzed. Samples analyzed under those conditions will absorb more x-rays than just those emitted by the instrument silver anode tube, resulting in a potential high bias. This type of interference is identified by radiological surveys and minimized by relocating measurements to areas of lower activity when feasible.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗