At least 577 records · Page 32

A high-fidelity building performance simulation test bed for the development and evaluation of advanced controls

We present an open-source building performance simulation test bed, the Advanced Controls Test Bed (ACTB), that interfaces high-fidelity Spawn of EnergyPlus building models, with advanced controllers implemented in Python. Additionally, the ACTB leverages the Building Optimization Testing and Alfalfa platforms for managing simulations, providing an external clock, a representational state transfer (REST) application programming interface (API), and key performance indicators for evaluating the effectiveness of control strategies. The REST API allows the development of external controllers programmed in languages such as Python, which provides flexibility and a rich choice of scientific libraries for designing control sequences. We present three test cases based on the U.S. Department of Energy's Reference Small Office Building to demonstrate the ACTB's capabilities: (a) rule-based controls compliant with ASHRAE Guideline 36 control sequences; (b) an economic model predictive control implemented using do-mpc; and (c) a deep Q-network reinforcement learning agent implemented using OpenAI Gym.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Static actuator-sharing algorithm for concurrent control of multiple plasma properties

Simultaneous regulation of multiple properties in next-generation tokamaks like ITER and fusion pilot plant may require the integration of different plasma control algorithms. Such integration requires the conversion of individual controller commands into physical actuator requests while accounting for the coupling between different plasma properties. This work proposes a tokamak and scenario-agnostic actuator-sharing algorithm (ASA) to perform the above-mentioned command-request conversion and, hence, integrate multiple plasma controllers. The proposed algorithm implicitly solves a quadratic programming (QP) problem formulated to account for the saturation limits and the relation between the controller commands and physical actuator requests. Since the constraints arising in the QP program are linear, the proposed ASA is highly computationally efficient and can be implemented in the tokamak plasma control system in real time. Furthermore, the proposed algorithm is designed to handle real-time changes in the control objectives and actuators’ availability. Nonlinear simulations carried out using the Control Oriented Transport SIMulator illustrate the effectiveness of the proposed algorithm in achieving multiple control objectives simultaneously.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Divertor detachment and heat exhaust mitigation control in KSTAR with tungsten divertor

KSTAR has recently undergone an upgrade to use a new tungsten divertor to run experiments in ITER-relevant scenarios. Even with a high melting point of tungsten, it is important to control the heat flux impinging on tungsten divertor targets to minimize sputtering and contamination of the core plasma. Heat flux on the divertor is often controlled by increasing the degree of detachment of scrape-off layer plasma from the target plates. In this work, we have demonstrated successful divertor detachment and heat exhaust dissipation control experiments using two different methods. The first method uses attachment fraction as a control variable which is estimated using ion saturation current measurements from embedded Langmuir probes in the divertor. The second method uses a novel machine-learning-based surrogate model of 2D UEDGE simulation database, DivControlNN. We demonstrated running inference operation of DivControlNN in realtime to estimate heat flux at the divertor and use it as the control variable in a feedback loop with impurity gas flow. We present interesting insights from these experiments including a systematic approach to tuning controllers and discuss future improvements in the control infrastructure and control variables for future burning plasma experiments.

KSTAR tungsten divertor operations↗

Demonstration of reconstruction-free static magnetic control of DIII-D plasma with deep reinforcement learning

This paper presents the development and experimental validation of a reinforcement learning (RL)-based magnetic controller on the DIII-D tokamak. The controller directly maps raw magnetic diagnostic signals to actuator commands, replacing the traditional isoflux control algorithm based on equilibrium reconstruction. Four RL controllers are trained using the Soft Actor–Critic algorithm with an asymmetric Actor–Critic architecture in the NSFsim simulator. All controllers are deployed in the DIII-D Plasma Control System and operated with a 4 kHz feedback loop. Two randomization strategies are evaluated during training: evolving kinetic profiles and fixed kinetic profiles within each episode. The latter approach is found to better capture experimental deviations in the current density profile and to provide overall improved control performance. Robust operation is demonstrated across heating power scans in both L- and H-mode plasmas, as well as during transient events such as L–H transitions and pellet injections. Control errors in plasma shape and radial position remained within 1.5–2.0 cm and 1 cm, respectively. A notable discrepancy was observed in the vertical X-point position, with errors of up to approximately 4 cm, attributed to the current density distribution mismatches between simulations and experiments.

DIII-D↗

Demonstration of tokamak vertical stability control based on non-inductive Faraday-effect polarimetry measurements

Long-pulse or steady-state fusion reactors are envisioned to control vertical stability based on non-inductive measurements, i.e. that do not rely on temporal change of magnetic field. For the first time, vertical stability control using non-inductive Faraday-effect polarimetry measurements has been demonstrated. The Radial Interferometer-Polarimeter system on DIII-D is capable of microsecond resolution and was used to absolutely determine the vertical position of the plasma magnetic axis Z 0 . A vertical stability controller was developed to robustly stabilize diverted plasmas using Faraday-based measurements. The system was able to stabilize against vertical displacement events with growth rates up to 350 s -1 in elongated and elliptical plasma shapes, and instabilities with even higher growth rates are likely to be controllable with further improvements to controller tuning. Tests show that the Faraday-based controller remains effective and is capable of recovering from loss of control even when the plasma vertical position is far from the region where the linear model used to calculate Z 0 is most valid. Faraday control has also been activated during plasma ramp-up, demonstrating the robustness of the technique to larger systematic diagnostic uncertainty at low electron density.

Faraday-effect polarimetry↗

Verifying the Computational Integrity of Power Grid Controls with Zero-Knowledge Proof

The control of future power grids is migrating from a centralized to a distributed/decentralized scheme to enable a massive penetration of distributed energy resources with rising dependence on communication infrastructure. A common assumption made for most existing distributed/decentralized controllers is that local controllers would faithfully follow the designated controller dynamics based on the data received from communication channels. However, with increased probability of cyberattacks on Operational Technology infrastructure, such an assumption could be risky because proper execution of the controller dynamics is then built on trust in secure communication and computation. In this work, we leverage a cryptography technology known as zero-knowledge scalable transparent arguments of knowledge (zk-STARK) to verify the computational integrity of power grid control algorithms, with projected linear dynamics-based control schemes as the initial proof-of-concept test case. The method presented here converts the cybersecurity challenge of data integrity for grid control into a subset of computational integrity.

computational integrity↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

controller hardware-in-the-loop↗

Robust Predictive Control for Modular Solid-State Transformer With Reduced DC Link and Parameter Mismatch

This paper presents the analysis and implementation of a predictive control method for dc-link regulation and voltage balance in a cascaded modular reduced dc-link solid-state transformer (SST). Passive components like bulky dc links limit the power density of power converters, especially medium-voltage (MV) SST. Reduced dc-link or low-inertia converters can dramatically reduce the size, cost, and weight by tolerating larger dc-link ripples and improve the reliability with electrolytic capacitor-less dc link. However, a small dc link leads to tight coupling between the input and the output stages, which is a challenge for control design. In stacked low-inertia converters (SLIC), the low-inertia converter modules are stacked for MV applications, resulting in coupling between the modules and making the control more challenging. A new model predictive control method which can achieve deadbeat regulation on the dc link without weighting factors has been proposed to address this novel problem. This paper focuses on analyzing the condition of the low-inertia dc link up to 80% ripple, the robustness of the control under parameter mismatches, high-order terms, and important implementation issues such as model-based sampling and computation delay compensation. Significantly, the high-order terms are introduced because of the large dc-link ripple. These high-order terms are unique to the SLIC and negligible in conventional high-inertia converters. A discrete-time large-signal model is built to capture the dc-link’s nonlinear dynamics, and the eigenvalues of a small-signal Jacobian matrix are analyzed with Floquet theory to evaluate stability, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. Simulation and experimental results of an MVDC M-S4T verify the analysis and the predictive control method. Finally, the general application of the predictive control to low-inertia converters is compared against a conventional PI controller using a reduced dc-link active-front-end (AFE) rectifier as an example.

14 SOLAR ENERGY↗

Learning Constrained Parametric Differentiable Predictive Control Policies With Guarantees

We present differentiable predictive control (DPC), a method for offline learning of constrained neural control policies for nonlinear dynamical systems with performance guarantees. We show that the sensitivities of the parametric optimal control problem can be used to obtain direct policy gradients. Specifically, we employ automatic differentiation (AD) to efficiently compute the sensitivities of the model predictive control (MPC) objective function and constraints penalties. To guarantee safety upon deployment, we derive probabilistic guarantees on closed-loop stability and constraint satisfaction based on indicator functions and Hoeffding’s inequality. We empirically demonstrate that the proposed method can learn neural control policies for various parametric optimal control tasks. In particular, we show that the proposed DPC method can stabilize systems with unstable dynamics, track time-varying references, and satisfy nonlinear state and input constraints. Our DPC method has practical time savings compared to alternative approaches for fast and memory-efficient controller design. Specifically, DPC does not depend on a supervisory controller as opposed to approximate MPC based on imitation learning. We demonstrate that, without losing performance, DPC is scalable with greatly reduced demands on memory and computation compared to implicit and explicit MPC while being more sample efficient than model-free reinforcement learning (RL) algorithms.

97 MATHEMATICS AND COMPUTING↗

Insensitivity to propagation timing in a preview-enabled wind turbine control experiment

Lidar scanners are capable of taking measurements of a wind field upstream of a wind turbine. The wind turbine controller can use these measurements as a “preview” of future disturbances impacting the turbine. Such preview-enabled (or feedforward) controllers show superior performance to standard wind turbine control configurations based purely on a feedback architecture. To capitalize on the performance improvements that preview wind measurements can provide, feedforward control actions should be timed to coincide with the arrival of the wind field at the wind turbine location. However, the time of propagation of the wind field between the lidar measurement location and the wind turbine is not perfectly known. Moreover, the best time to take feedforward control action may not perfectly coincide with the true arrival time of the wind disturbance. This contribution presents results from an experiment where preview-enabled model predictive control was deployed on a fully-actuated, scaled model wind turbine operating in a wind tunnel testbed. In the study, we investigate the sensitivity of the controller performance to the assumed propagation delay using a range of wind input sequences. We find that the preview-enabled controller outperforms the feedback only case across a wide range of assumed propagation delays, demonstrating a level of robustness to the time alignment of the incoming disturbances.

17 WIND ENERGY↗

Wind Turbine Gust Load Alleviation with Active Flow Control

Large wind turbine rotors are becoming more common in utility-scale wind power, especially for offshore wind plants. However, the trend toward large rotors can be limited by their ability to manage dynamic and extreme loads. To provide a safety margin for the rotor design and avoid catastrophic events such as tower strikes, extreme loads need to be controlled. The objective of this study is to develop and evaluate a feedback control system to alleviate extreme loads and reduce blade deflections under gust events using active flow control devices. We also propose a modification in the turbine controller to achieve further reduction in extreme loads. The extreme load reductions are evaluated under gust wind conditions with direction changes according to the IEC standard. The effects of the gust alleviation controller on turbine performance and fatigue loads are investigated as well. With the deployment of the gust alleviation controller and modified turbine baseline controller, the extreme loads and deflections reduce by up to 23%. The energy captured by the turbine is not affected by the proposed gust alleviation controller. The fatigue loads of various wind turbine components are either reduced or remain unchanged.

17 WIND ENERGY↗

A Model Predictive Control to Improve Grid Resilience

The following article details a model predictive control (MPC) to improve grid resilience when faced with variable generation resources. This topic is of significant interest to utility power systems where distributed intermittent energy sources will increase significantly and be relied on for electric grid ancillary services. Previous work on MPCs has focused on narrowly targeted control applications such as improving electric vehicle (EV) charging infrastructure or reducing the cost of integrating Energy Storage Systems (ESSs) into the grid. In contrast, this article develops a comprehensive treatment of the construction of an MPC tailored to electric grids and then applies it integration of intermittent energy resources. To accomplish this, the following article includes a description of a reduced order model (ROM) of an electric power grid based on a circuit model, an optimization formulation that describes the MPC, a collocation method for solving linear time-dependent differential algebraic equations (DAEs) that result from the ROM, and an overall strategy for iteratively refining the behavior of the MPC. Next, the algorithm is validated using two separate numerical experiments. First, the algorithm is compared to an existing MPC code and the results are verified by a numerically precise simulation. It is shown that this algorithm produces a control comparable to existing algorithms and the behavior of the control carefully respects the bounds specified. Second, the MPC is applied to a small nine bus system that contains a mix of turbine-spinning-machine-based and intermittent generation in order to demonstrate the algorithm’s utility for resource planning and control of intermittent resources. This study demonstrates how the MPC can be tuned to change the behavior of the control, which can then assist with the integration of intermittent resources into the grid. The emphasis throughout the paper is to provide systematic treatment of the topic and produce a novel nonlinear control compatible design framework applicable to electric grids and the control of variable resources. This differs from the more targeted application-based focus in most presentations.

microgrid↗

Demonstration of a fault impact reduction control module for wind turbines

Abstract. Traditionally, wind turbines in distributed applications make control decisions as isolated systems. They generally provide maximum power output during operation and manage internal faults with little consideration of the rest of the power system. Although fault detection and tolerance schemes are widely researched and implemented, controls to ameliorate such faults are uncommon in research and industry. The rapid shutdown of a wind turbine in a large transmission-connected wind plant will have a minimal impact on a large power system, but in a microgrid or isolated grid context the abrupt loss of a single wind turbine may cause grid instability and high stress on the system. This paper demonstrates a fault impact reduction control (FIRC) module for a wind turbine, which implements wider warning thresholds around fault thresholds. When the turbine crosses a warning threshold, the controller sends its predicted action to the grid controller, which facilitates the grid operator’s response to a potential wind turbine fault and then takes appropriate action to ameliorate the fault. Various test cases demonstrate the controller action under a variety of faults, and various scenarios demonstrate the grid benefit of an FIRC in both microgrid- and grid-connected contexts. The FIRC maximizes wind turbine generation and eases generation transition under a variety of fault scenarios. The FIRC module is easy to integrate with most existing controllers, just requiring derate capability, and can be easily modified to include the various warnings and thresholds that the user desires. This analysis is mainly performed in a MATLAB-Simulink-based research wind turbine model and is also implemented in the existing LabVIEW-based controller of the same research turbine at NREL.

17 WIND ENERGY↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation: Preprint

Utilities have been installing microgrids due to the advancements in the distributed energy resources technologies. Microgrids also improve the resiliency of the system due to their capability to isolate themselves from the grid and run in islanded mode of operation. Microgrid controllers are management systems that can run the microgrids under varied operating condition and enable the smooth operation of microgrids under various system conditions. It is of high value to de-risk the installation of such controllers. Hardware-in-the-loop evaluation is used by controller developers and utilities to evaluate the controllers under stressful conditions to understand the performance and to understand the necessary improvements to the microgrid controller. In this research work, the team has leveraged the existing infrastructure of real-time simulation at the Energy Systems Integration Facility (ESIF) and the capability of the microgrid controller to control assets over the Internet Protocol (IP) to evaluate a university developed microgrid controller in an efficient and cost-effective manner. The full paper will provide the complete setup, the experimental use cases and the results. In this abstract, one use case will be expalined, and the results from the use case is provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multilevel Conditional Disturbance Rejection Control for Satellite Attitude Tracking

Recently, the conditional disturbance rejection controller (CDRC) was proposed to improve control performance by leveraging disturbances that have beneficial effects on the system. However, it only considers disturbances acting on the state variable directly influenced by them. Although fast convergence of this state can be achieved with the CDRC, it may unintentionally affect the convergence of the output (i.e., the primary state). Here, in this article, a multilevel CDRC is proposed to enhance satellite attitude control performance by accounting for the effect of disturbances on both attitude (output) and angular velocity. The extended state observer is employed to estimate the lumped disturbance, including the modeling errors and external disturbances. Then, a backstepping-based controller with the multilevel disturbance rejection law (ML-DRL) is designed for attitude tracking. The ML-DRL is developed to improve the control performance by using a disturbance with a damping effect on both attitude and velocity. Faster convergence of attitude and velocity can be achieved by conditionally compensating for the disturbance. The stability of the proposed control method is analyzed by demonstrating that the errors are bounded as time tends to infinity. The attitude control performance of the proposed method is evaluated through numerical examples conducted using the MATLAB/Simulink Multibody tool.

Active disturbance rejection control (ADRC)↗

An Optimal Power Control Strategy for Grid-Following Inverters in a Synchronous Frame

This work proposes a power control strategy based on the linear quadratic regulator with optimal reference tracking (LQR-ORT) for a three-phase inverter-based generator (IBG) using an LCL filter. The use of an LQR-ORT controller increases robustness margins and reduces the quadratic value of the power error and control inputs during transient response. A model in a synchronous reference frame that integrates power sharing and voltage–current (V–I) dynamics is also proposed. This model allows for analyzing closed-loop eigenvalue location and robustness margins. The proposed controller was compared against a classical droop approach using proportional-resonant controllers for the inner loops. Mathematical analysis and hardware-in-the-loop (HIL) experiments under variations in the LCL filter components demonstrate fulfillment of robustness and performance bounds of the LQR-ORT controller. Experimental results demonstrate accuracy of the proposed model and the effectiveness of the LQR-ORT controller in improving transient response, robustness, and power decoupling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Filtering adaptive output feedback control for multivariable nonlinear systems with mismatched uncertainties and unmodeled dynamics

This article synthesizes a filtering adaptive output feedback controller for multivariable nonlinear systems with mismatched uncertainties and unmodeled dynamics. The multivariable nonlinear systems under consideration have both matched and mismatched uncertainties, which satisfy the semiglobal Lipschitz condition. The unmodeled dynamics are bounded-input bounded-output stable. By adopting an estimation/cancellation strategy, a piecewise constant adaptive law drives the estimation error to zero at every time instant, which yields the adaptive parameters; a disturbance rejection control law is designed to compensate the nonlinear uncertainties within the bandwidth of low-pass filters. The matched uncertainties are cancelled directly by adopting their opposite in the control signal, while a dynamic inversion of the system is required to eliminate the effect of the mismatched uncertainties on the output. A feedforward control law is designed to track a given command. Since the virtual reference system defines the best performance that can be achieved by the closed-loop system, the uniform performance bounds are derived for the states and control signals via comparison. Both numerical and practical examples are provided to illustrate the effectiveness of the proposed filtering adaptive output feedback control architecture, comparisons with the model reference adaptive control demonstrates the superiority of the proposed control method.

filtering adaptive control, mismatched uncertainit↗