Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Dynamic Undervolting to Improve Energy Efficiency on Multicore X86 CPUs

Chip manufacturers introduce redundancy at various levels of CPU design to guarantee correct operation, even for worst-case combinations of non-idealities in process variation and system operating conditions. This redundancy is implemented partly in the form of voltage margins. However, for a wide range of real-world execution scenarios these margins are excessive and merely translate to increased power consumption, hindering the effort towards higher-energy efficiency in both HPC and general purpose computing. Our study on the x86-64 Haswell and Skylake multicore microarchitectures reveals-wide voltage margins, which vary across different microarchitectures, different chip parts of the same microarchitecture, and across different workloads. We find that it is necessary to quantify-voltage margins using multi-threaded and multi-instance workloads, as characterization with single-threaded and single-instance workloads that do not stress the CPU to its full capacity typically identifies overly optimistic margins that lead to errors when applied in realistic program execution scenarios. In addition, we introduce, deploy and evaluate a run-time governor that dynamically reduces the supply voltage of modern multicore x86-64 CPUs. Our governor employs a model that takes as input a set of performance metrics which are directly measurable via performance monitoring counters and have high predictive value for the minimum tolerable supply voltage (V min ), to predict and apply the appropriate reduction for the workload at hand. Compared with the conventional DVFS governor, our approach in this study achieves up to 42 percent energy savings for the Skylake family and 34 percent for the Haswell family for complex, real-world applications.

97 MATHEMATICS AND COMPUTING↗

Efficient Image Reconstruction Method for a Millimeter-wave Shoe Scanner

The Pacific Northwest National Laboratory (PNNL) has recently developed an active 3D microwave/millimeter-wave shoe scanner. This system is designed to detect threats concealed within the soles of common footwear. The system operates over the 10-40 GHz frequency range for excellent penetration of common materials. The system presents several challenges for efficient image reconstruction, including the thick dielectric window, multi-row linear arrays, and focusing close to the antenna elements. In this paper, an efficient back-projection reconstruction algorithm is presented that overcomes these challenges. Experimental imaging results are shown that demonstrate high-resolution imaging performance for this new scanner.

Sheen, David M.↗

Report on the deployment of the National Geothermal Data System 2.0

This reports includes a video description of recent upgrades and changes to the National Geothermal Data System (geothermaldata.org) and a text report of its relevant security upgrades. Improvements include a new operating system, implementation of HTTPS, implementation of a standard firewall, PostgreSQL upgrades, an ESRI ArcGIS server, new registration policies, and a non-public API.

15 GEOTHERMAL ENERGY↗

Performance Potential of Mixed Data Management Modes for Heterogeneous Memory Systems

Many high-performance systems now include different types of memory devices within the same compute platform to meet strict performance and cost constraints. Such heterogeneous memory systems often include an upper-level tier with better performance, but limited capacity, and lower-level tiers with higher capacity, but less bandwidth and longer latencies for reads and writes. To utilize the different memory layers efficiently, current systems rely on hardware-directed, memory -side caching or they provide facilities in the operating system (OS) that allow applications to make their own data-tier assignments. Since these data management options each come with their own set of trade-offs, many systems also include mixed data management configurations that allow applications to employ hardware- and software-directed management simultaneously, but for different portions of their address space. Despite the opportunity to address limitations of stand-alone data management options, such mixed management modes are under-utilized in practice, and have not been evaluated in prior studies of complex memory hardware. In this work, we develop custom program profiling, configurations, and policies to study the potential of mixed data management modes to outperform hardware- or software-based management schemes alone. Our experiments, conducted on an Intel ® Knights Landing platform with high-bandwidth memory, demonstrate that the mixed data management mode achieves the same or better performance than the best stand-alone option for five memory intensive benchmark applications (run separately and in isolation), resulting in an average speedup compared to the best stand-alone policy of over 10 %, on average.

Effler, Chad↗

Computational analysis of deployable wind turbine systems in defense operational energy applications.

The U.S. military has been exploring pathways to reduce the logistical burden of fuel on virtually all their missions globally. Energy harvesting of local resources such as wind and solar can help increase the resilience and operational effectiveness of military units, especially at the most forward operating bases where the fuel logistics are most challenging. This report considers the potential benefits of wind energy provided by deployable wind turbines as measured by a reduction in fuel consumption and supply convoys to a hypothetical network of Army Infantry Brigade Combat Team bases. Two modeling and simulation tools are used to represent the bases and their operations and quantify the impacts of system design variables that include wind turbine technologies, battery storage, number of turbines, and wind resource quality. The System of Systems Analysis Toolkit Joint Operational Energy Model serves as a baseline scenario for comparison. The Hybrid Optimization of Multiple Energy Resources simulation tool is used to optimize a single base within the larger Joint Operational Energy Model. The results of both tools show that wind turbines can provide significant benefits to contingency bases in terms of reduced fuel use and number of convoy trips to resupply the base. The match between the turbine design and wind resource, which is statistically low across most of the global land area, is a critical design consideration. The addition of battery storage can enhance the benefits of wind turbines, especially in systems with more wind turbines and higher wind resources. Wind turbines may also provide additional benefits to other metrics such as resilience that may be important but not fully considered in the current analysis. ACKNOWLEDGEMENTS The authors would like to thank the following individuals for their helpful support, feedback and review to improve this report: U.S. Department of Energy Wind Energy Technologies Office, Patrick Gilman and Bret Barker; Idaho National Laboratory, Jake Gentle and Bradley Whipple; The National Renewable Energy Laboratory, Robert Preus and Tony Jimenez; Sandia National Laboratories, Alan Nanco, Dennis Anderson, and Hai Le. In addition, numerous discussions with military and industry stakeholders over the year were invaluable in focusing the efforts represented in this report.

17 WIND ENERGY↗

Robust Distribution System Load Restoration With Time-Dependent Cold Load Pickup

Service restoration is one of the critical functions to enable the future self-healing distribution system. To restore the distribution system in a timely and reliable manner, the realistic system operating conditions need to be accurately characterized. Here, two main factors that have great impacts on distribution system restoration (DSR) in practice are investigated. First, cold load pickup (CLPU), generally caused by thermostatically controlled loads (TCLs), is a common phenomenon after an outage and shaped by the outage duration. However, the time-dependent behaviors of CLPU are rarely considered in literature. In this paper, the operating state evolution of TCLs after an outage is analyzed to characterize time-dependent CLPU. And the time-dependent CLPU is analytically embedded in DSR to accurately represent the actual behaviors of the restored loads. Second, it is difficult to predict loads that fluctuate during DSR due to the lack of real-time measurement data. Accordingly, a robust DSR based on the information gap decision theory (IGDT) is proposed to address this challenge, fully considering the uncertainty of CLPU. The proposed models are tested in IEEE 13-node and 123-node test feeders. Simulation results demonstrate that the time-dependent CLPU model and the uncertainty modeling of CLPU can accurately capture the actual behaviors of loads with TCLs after an outage, which greatly improves DSR decisions in practice.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and performance evaluation of a dual-circuit thermal energy storage module for air conditioners

We present experimental results and a validated numerical model of a dual-circuit phase-change thermal energy storage module for air conditioners. The module incorporates a phase-change material encapsulated in compressed expanded natural graphite foam. We used n-tetradecane as the PCM with a transition temperature (~4.5 °C) suitable for air-conditioning applications. Heat exchange to and from the module is accomplished through two fluid loops operating as a heat source and sink embedded inside multiple slabs of the composite material. This dual-circuit design enables easier integration with air-conditioning equipment and provides enhanced flexibility in system operation as compared to the state-of-the-art thermal storage systems. When integrated with an air-conditioner, this design will enable peak-load shaving and enhances operational efficiency. The thermal storage device was designed for a nominal storage capacity of ~ 3.5 kWh. We evaluated the heat transfer and energy storage performance of this device using standalone heat transfer experiments to estimate key thermal resistances and identify design improvements before integration with an air conditioner. The numerical model of the heat exchanger uses a combination of discretized and lumped parameter approaches to maintain a balance between accuracy and computational expense. Our analyses show that the geometric features and integration of fluid tubes are key contributors to the thermal contact resistance between the fluid and the thermal storage material, and consequently, to the overall performance of the thermal storage module. Our standalone experiments also identified important operating scenarios in which this thermal storage module can be used for air-conditioning in buildings.

25 ENERGY STORAGE↗

Flexibility Requirements for Energy Systems with Renewable Generation under Forecast Uncertainties

Energy systems with high fractions of renewable energy-based resources require adequate assets providing flexibility in electricity usage to maximize the benefits of renewable energy. In this paper, we provide an analytical approach to estimate the flexibility requirements of such energy systems, with forecast uncertainties in both demand and generation. Our analytical results show that even with forecast errors, the expected system operating cost decreases with an increase in the amount of flexibility capacity -- however, there is an inflection point, beyond which addition of further flexibility capacity does not reduce expected system cost any further. Additionally, an enumeration-based approach is presented to estimate the maximum flexibility capacity needed to optimize the operating cost. Numerical experiments conducted on a network-abstracted modified IEEE 30-bus system are used for empirical validation and gaining additional insights on the effect of prosumers' willingness to offer flexibility on the dispatch performance.

Bhattacharya, Saptarshi↗

Enhanced Precision in Geothermal Reservoir Characterization and Exploitation

The objective of this project is to demonstrate how enhanced analytical and artificial intelligence (AI) algorithms can play a critical role in all phases of geothermal resource development including 1) exploration, 2) exploitation, 3) maintenance, and 4) electric grid integration. A secondary goal, but one that in all likelihood will become more impactful, is to repurpose Introspective System's open source research and deployment architecture, xGraph™, so that is capable of significantly accelerating both the research as well as the deployment of operational systems for exploiting our nation’s vast geothermal resources. This development framework could be used to accelerate deployment by commercial operational enterprises.

15 GEOTHERMAL ENERGY↗

On the role of Battery Energy Storage Systems in the day-ahead Contingency-Constrained Unit Commitment problem under renewable penetration

The integration of variable Renewable Energy Sources (vRES) to alleviate greenhouse gas emissions has introduced significant challenges for power systems operations. These challenges include high levels of uncertainty due to the intermittence associated with vRES and therefore impose the need to devise a reliable and cost-effective day-ahead unit commitment and power and reserves scheduling for real-time operations. Also, this increasing penetration of vRES requires higher ramping capabilities from units originally designed for other purposes (e.g., base-load generation), which might be exacerbated during contingency states. Hence, in this work, we propose a methodology to address the day-ahead Contingency-Constrained Unit Commitment (CCUC) problem that leverages the participation of Battery Energy Storage Systems (BESSs) to address load-following and post-contingency management, therefore alleviating the ramping burden on conventional thermal generators. To do so, we formulate a three-level optimization problem that represents the decision-making process of obtaining the least-cost commitment, generation and reserves scheduling, while restricting the Conditional Value-at-Risk (CVaR) of the system imbalance at real-time operations to user-defined tolerance levels. In addition, we devise a computationally efficient solution approach for the proposed problem based on the Column-and Constraint Generation (CCG) algorithmic framework. Two numerical experiments are conducted to empirically illustrate the benefits of the proposed methodology. Key results indicate a reduction in real-time ramping needs and a better usage of the system resources, with a reduction in the overall system commitment levels and reserve scheduling costs when compared to a benchmark case in which storage is not available.

Moreira, Alexandre↗

Frequency Nadir Constrained Unit Commitment for High Renewable Penetration Island Power Systems

The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system's frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PSI (PowerSimulations.jl) [SWR-23-104]

PowerSimulations.jl is a Julia-based BSD- licensed power system operations simulation tool developed as a flexible and open source software for quasi-static power systems simulations including Production Cost Models. PowerSimulations.jl tackles the issues of developing a simulation model in a modular way providing tools for the formulation of decision models and emulation models that can be solved independently or in an interconnected fashion. For further information regarding the Sienna modeling framework at NREL, see: https://www.nrel.gov/analysis/sienna.html

Lara Aguilar, Jose Daniel↗

Pumped Storage Hydro Model Evaluation Report Task 1: Tool Assessment

Pumped storage hydro (PSH) projects support various aspects of power system operations. However, determining the value of PSH projects and the many services and contributions to the system they provide can be a challenge. The PSH techno-economic studies being carried out by a 5-lab consortium are defining extensive modeling approaches for evaluating the economic benefits of PSH projects. To enhance the impact of the valuation approach and follow-on techno-economic studies, Pacific Northwest National Laboratory (PNNL) will be developing a set of online tools that industry could adopt and use to advance PSH projects in the US. The problem is that the research team is not entirely clear on the features of the tools that would offer the most significant impact to industry. Thus, year one of this effort is designed to first define the needs of industry before developing the PSH valuation tool. The first step in defining industry needs is to evaluate existing tool packages, including those created by DOE and those by industry groups, to both measure usage levels and define tool attributes that maximize industry impact. The second step in this process will be to hold a workshop designed to elicit direct industry input. Given the breadth and nature of the task, which is to define ideal model attributes, the research team did not constrain the assessment to storage valuation tools. Several tools were assessed, and their characteristics compared against a list of “ideal” attributes that included ease of use, generalizability of results, and analytical flexibility. Information regarding usage and impact were then compared to specific model attributes to define which attributes appear to drive success. The following key lessons and implications can be drawn from the analysis: Models with high ease of use were often the most adopted by industry, though they did not necessarily have high publication reference records, meaning a published article made direct reference to the tool. For example, REScheck TM and COMcheck TM , two tools which share a site, have seen a high amount of web traffic and usage. Similarly, Storage Value Estimate Tool (StorageVET®), an energy storage valuation model, has a large number of organizations using it despite a low publication reference record. A common feature between these models is that they are web-hosted, theoretically making them more easily accessible with graphic user interfaces (GUIs) that are more navigable; Models with higher usage statistics were typically free and/or open source. While it may be unsurprising that this attribute could be considered a draw for users, there is the potential for overestimating the tool's value based on popularity due to the fact that some users may have used the model simply because it was free and not because it is the best model; Models that offer more in-depth analysis and a wide coverage of applications (e.g. VOLTTRON™, GridLAB-D™, and Integrated Valuation of Ecosystem Services and Tradeoffs (InVest)) have shown a high number of publication references as well as showing a high number of downloads in the case of GridLAB-D™. It should be noted that the figure below does not include the model with the highest number of publication references (EnergyPlus™) as it has been removed to show clearer distinction between the remaining tools; The most popular model within the evaluation list was EnergyPlus™. This tool has the highest number of publication references (2,034) of all models considered and contains both a high ease of use level as well as broad application flexibility. Its high usage may be correlated, however, with the presumed wider audience conducting energy consumption modeling compared to the audiences for some of the other tools in this list; Models that were low in both general usage and publication reference generally did not exhibit characteristics considered ideal by the research team. Some of these models offered a narrower range of analytical applications or lower generalizability of results. This would automatically restrict the pool of potential users to those who fall within a narrow range of specific technologies or applications. This report also explores two model structures for the PSH tool: decision tree-based, which would guide the user through the valuation methods defined in the PSH techno-economic studies currently being carried out by DOE, and an all-inclusive comprehensive model. The strengths of each were explored and a hybrid approach was defined that would embed a price taker model into the decision tree approach. Such an approach would provide a comprehensive approach for modeling small-scale PSH while recognizing the challenges associated with implementing a price-maker approach in an all-inclusive model. Insight gained in this analysis of other models can aid in narrowing down the list of effective and sought-after attributes, and in defining model structure. Next steps toward developing a model for storage valuation will be to gain direct industry input through workshops.

13 HYDRO ENERGY↗

Frequency-Nadir-Constrained Unit Commitment for Low-Inertia, High-IBR Island Power Systems [Slides]

The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system's frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.

14 SOLAR ENERGY↗

Operating-Envelopes-Aware Decentralized Welfare Maximization for Energy Communities: Preprint

We propose an operating-envelope-aware, prosumer-centric, and efficient energy community that aggregates individual and shared community distributed energy resources downstream of a regulated distribution system operator's (DSO) net energy metering revenue meter. Due to the elevated risk of grid constraint violations and to ensure safe network operation, the DSO imposes dynamic export and import limits, known as dynamic operating envelopes, on end-users' revenue meters. Given the operating envelopes, the proposed community market mechanism maximizes the community's social welfare in a decentralized fashion while every community member abides by its own operating envelopes. We show that the proposed market mechanism conforms with the cost-causation principle and guarantees community members a surplus level no less than their maximum surplus when they autonomously face the DSO. Lastly, a numerical study is implemented to showcase and compare the community's welfare under the proposed operating-envelopes-aware mechanisms to others, including the welfare of customers under the DSO's regime.

distributed energy resources aggregation↗

Success Path Method: Conformance with Safety Management Systems

All industrial facilities deal with safety hazards such as equipment failures, chemical and toxic releases, and fires and explosions just to name a few. A disciplined framework for managing the integrity of operating systems and processes that handle hazardous substances by applying good design principles, engineering, and operating practices is called process safety. The goal of such framewoks is to prevent the release of energy or material that could cause harm to people or damage to equipment and/or environment. Process safety covers all aspects of facility operation also including design, maintenance, and human and organizational factors that could possibly have effect on process safety. As it will be seen from the discussion below, process safety is just one of the pieces of the much bigger matter, a safety culture. Many industries have long recognized the importance of safety culture in their day-to-day operation. Although the definition of safety culture can slightly differ from organization to organization, in general, a safety culture is how things are done to demonstrate a commitment to safety by everyone involved. An organization acquires safety culture over time as the product of individual and group values, actions, and behaviors toward overall safety. It is important to note that safety culture should not be viewed as some static state that an organization wants to reach. It is more like a constantly evolving level of “how things are done when nobody is watching.” Safety culture is an inherent characteristic of an organization, it is always present, but the level can range on a continuum from undesirable to desirable or more commonly used, from negative to positive. An example for an undesirable, negative safety culture would be a company in which accidents resulting in harm (physical and/or emotional) of its employees, equipment or surrounding environment and community occur frequently. At the other end of the spectrum would be a company in which such accidents are rare or do not occur at all (desired or positive safety culture). Every company/industry exists somewhere within this spectrum.

42 ENGINEERING↗

Century: Zap Energy’s 100-kW-Scale Repetitive Sheared-Flow-Stabilized Z -Pinch System with Liquid Metal Cooling

Zap Energy is developing the sheared-flow-stabilized (SFS) Z-pinch concept for commercial applications. The SFS Z pinch relies on plasma self-organization, in the sense that plasma dynamics play a critical role in confinement. Using plasma axial current for confinement and compression eliminates the need for external confinement or heating technologies. This compact magnetic confinement technology could, in turn, provide the basis for a cost-effective deuterium-tritium fusion power plant. In addition to a robust experimental program pushing plasma performance towards breakeven conditions, Zap Energy has parallel programs developing power handling systems suitable for future power plants. Technologies under development include high average-power repetitive pulsed power, high duty-cycle cathodes, and liquid metal wall systems. Century is the name of Zap Energy’s first effort to integrate these three components into an operational system capable of firing non-reacting hydrogen SFS Z-pinch plasmas into a liquid-metal-lined container at sustained repetition rates on the order of 0.1 Hz. Here, the pulsed power driver and liquid metal heat exchanger are both designed to sustain input powers of 100 kW. Construction and initial operations with an interim ~10 kW liquid metal heat exchanger are described.

Century↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗