At least 559 records · Page 31

Controlling substrate temperature with infrared heating to improve mechanical properties of large-scale printed parts

Additively manufactured parts made with polymer extrusion techniques can be 50-75% weaker in the z-direction (across layers) than in the x- and y-directions. This has been attributed to poor mobility of polymer chains and a low degree of entanglement across a cold deposition interface. This is particularly a challenge when printing large-scale parts, such as with the Big Area Additive Manufacturing (BAAM) system, because layer times can exceed several minutes. The current work presents a method for controlling the temperature of the substrate material on the BAAM just prior to deposition using infrared heating lamps. Additionally, long layer times were simulated by actively cooling the material following deposition of each layer. The effect of substrate temperature on the z-direction mechanical properties of 20% carbon fiber reinforced acrylonitrile butadiene styrene (ABS) was measured for an initial temperature ranging from 50 °C to 150 °C and a preheated temperature ranging from 150 °C to 220 °C. Infrared preheating proved to be very effective when applied to substrates that had cooled considerably, almost doubling the tensile strength and increasing the fracture toughness by a factor of 7x.

36 MATERIALS SCIENCE↗

Innovations in Sensors and Controls for Building Energy Management: Research and Development Opportunities Report for Emerging Technologies

Sensors, actuators, and controllers, which collectively serve as the backbone of cyberphysical systems for building energy management, are one of the core technical areas of investment for achieving the U.S. Department of Energy (DOE) Building Technologies Office's (BTO's) goals for energy affordability in the national building stock - both commercial and residential. In fact, an aggregated annual energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms. energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of the Human and Technology Integration Guidance for the Design of Plant-Specific Advanced Automation and Data Visualization Techniques

Nuclear power continues to be a safe, reliable, and carbon-free electricity generating source for the United States, though the cost of operating and maintaining the current United States nuclear power plant fleet has become uncompetitive with other sources. This gap is attributed to the advent of new digital instrumentation and control technologies that other electricity generating industries are currently leveraging to streamline work and greatly reduce operating, maintenance, and support costs. Digital instrumentation and control systems and control room modernization offers significant opportunities to reduce operating and maintenance costs to ensure the continued operation of the existing United States light-water reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Turbulence and Control of Wind Farms

The dynamics of the turbulent atmospheric boundary layer play a fundamental role in wind farm energy production, governing the velocity field that enters the farm as well as the turbulent mixing that regenerates energy for extraction at downstream rows. Understanding the dynamic interactions among turbines, wind farms, and the atmospheric boundary layer can therefore be beneficial in improving the efficiency of wind farm control approaches. Anticipated increases in the sizes of new wind farms to meet renewable energy targets will increase the importance of exploiting this understanding to advance wind farm control capabilities. This review discusses approaches for modeling and estimation of the wind farm flow field that have exploited such knowledge in closed-loop control, to varying degrees. We focus on power tracking as an example application that will be of critical importance as wind farms transition into their anticipated role as major suppliers of electricity. The discussion highlights the benefits of including the dynamics of the flow field in control and points to critical shortcomings of the current approaches.

Automation & Control Systems↗

Reactive CO 2 capture via controlled amine speciation in non-aqueous electrolytes

Current efforts to integrate CO 2 capture and electrochemical conversion (reactive capture) are often performed under aqueous conditions, resulting in undesired hydrogen evolution and reliance on precious metal catalysts and pure CO 2 streams. Here, in this study, we explore reactive capture in aprotic media. By shifting the amine–CO 2 adduct speciation to carbamic acid (instead of carbamate) in dimethyl sulfoxide, we increased CO 2 uptake threefold compared with an aqueous medium, suppressing hydrogen evolution and supporting a 78% Faradaic efficiency towards CO over an earth-abundant zinc catalyst. Under simulated high-oxygen-content flue gas (17% CO 2 , 17% O 2 , 66% N 2 ), we also obtained up to 43% CO Faradaic efficiency over multiple capture–conversion cycles. Our findings showcase the confluence of reactant speciation, electrolyte composition and electrocatalyst design in enabling selective and active electrochemical transformations.

Gomes, Reginaldo J. [Univ. of Chicago, IL (United ↗

Enabling Extreme Fast Charging through Control of Li Deposition Overpotential on Graphite Electrodes

Currently produced electric vehicles (EVs) rely on the use of lithium ion battery technology due to its high energy and power density. However, a major barrier facing the adoption of electric vehicles is that currently utilized Li-ion batteries take significantly longer to recharge (~ 30 minutes) compared to the time necessary to refuel vehicles powered by internal combustion engines (< 10 minutes). Thus, the need to develop Li-ion batteries which can be charged in approximately 10 minutes (6 C rate) without sacrificing range, cost, or cycle life is critical for the widespread implementation of EVs.

25 ENERGY STORAGE↗

Ultrafast THz emission spectroscopy of spin currents in the metamagnet FeRh

Heterostructures of ferromagnetic (FM) and noble metal (NM) thin films have recently attracted considerable interest as viable platforms for the ultrafast generation, control, and transduction of light-induced spin currents. In such systems, an ultrafast laser can generate a transient spin current in the FM layer, which is then converted to a charge current at the FM/NM interface due to strong spin–orbit coupling in the NM layer. Whether such conversion can happen in a single material and how the resulting spin current can be quantified are open questions under active study. Here, we report ultrafast THz emission from spin–charge conversion in a bare FeRh thin film without any NM layer. Our results highlight that the magnetic material by itself can enable spin–charge conversion in the same order as that in a FM/NM heterostructure. We further propose a simple model to estimate the light-induced spin current in FeRh across its metamagnetic phase transition temperature. Our findings have implications for the study of the ultrafast dynamics of magnetic order in quantum materials using THz emission spectroscopy.

36 MATERIALS SCIENCE↗

Grid Forming Inverter With Increased Short-Circuit Contribution to Address Inverter-Based Microgrid Protection Challenges

Substantial differences in fault levels between grid-tied and islanded modes is one of the primary challenges of microgrid protection. During grid-tied mode, the bulk grid provides significant short-circuit, while during islanded operation the short-circuit magnitude is small due to inverter-based resources limiting their current output close to nominal ratings. Consequently, conventional distribution protection strategies based on overcurrent cannot reliably protect microgrids when operating in islanded mode. Fuses and circuit breakers are particularly affected because of their inverse characteristics. Presently, the absence of affordable solutions for protecting microgrids in islanded mode leads to microgrids shutting down during electrical faults. The contribution of this article is two-fold. The first innovation proposes specific hardware modifications to grid-forming inverters to increase their short-circuit current during electrical faults. The second innovation introduces a novel control strategy designed to preserve control stability margins even when the grid-filter saturates, ensuring sinusoidal output currents under normal and fault conditions. Through experimental results, the inverter with the proposed modifications can provide more than three-times its nominal current during electrical faults. For the prototype testbed, this was sufficient to enable the use of traditional legacy overcurrent protection, achieving the fuse-to-relay and relay-to-relay minimum coordination time for the line-to-ground, line-to-line to ground, and three-phase electrical faults.

42 ENGINEERING↗

Reaction‐induced morphology control in block copolymers

Abstract Controlling the self‐assembly behaviors of block copolymers (BCPs) is a focal point of many research thrusts due to their broad use in various applications. While BCP molecular weight, volume fraction, and chemical identities are key thermodynamic parameters to determine their morphology, an emergent method in this area is through reaction‐induced changes to the characteristics of a BCP in situ , which provides access to multiple morphologies and domain sizes from a single parent polymer, as well as enabling the formation of metastable morphologies which may be difficult to attain otherwise. This work provides a focused review about the current state of reaction‐induced morphology control in BCPs in both solution and solid states. Furthermore, we provide a forward‐looking perspective on the future opportunities of understanding and employing reaction engineering to manipulate and advance BCP self‐assembly. © 2023 Society of Industrial Chemistry.

Robertson, Mark↗

Assessment and Commissioning of Electrical Substation Grid Testbed with a Real-Time Simulator and Protective Relays/Power Meters in the Loop

Electrical utility substations are wired with intelligent electronic devices (IEDs), such as protective relays, power meters, and communication switches. Substation engineers commission these IEDs to assess the appropriate measurements for monitoring, control, power system protection, and communication applications. Like real electrical utility substations, complex electrical substation grid testbeds (ESGTs) need to be assessed for measuring current and voltage signals in monitoring, power system protection, control (synchro check), and communication applications that are limited by small measurement percentage errors. In the process of setting an ESGT with real-time simulators and IEDs in the loop, protective relays, power meters, and communication devices must be commissioned before running experiments. In this study, an ESGT with IEDs and distributed ledger technology was developed. The ESGT with a real-time simulator and IEDs in the loop was satisfactorily assessed and commissioned. The commissioning and problem-solving tasks of the testbed are described to define a method with flowcharts to assess possible trouble-shooting in ESGTs. This method was based on comparing the simulations versus IED measurements for the phase current and voltage magnitudes, three-phase phasor diagrams, breaker states, protective relay times with selectivity coordination at electrical faults, communication data points, and time-stamp sources.

Piesciorovsky, Emilio↗

Towards constrained grid-forming control

Grid-forming converters are commonly envisioned to replace conventional synchronous generators as the cornerstone of future power systems. However, compared to synchronous generators, power converters and their power sources (e.g., renewable generation, energy storage) are subject to significant physical constraints (e.g., current limits, modulation limits). Grid-forming controls are commonly designed neglecting these constraints and subsequently augmented with limiters for a subset of constraints. In this work, we propose a systematic approach to constrained grid-forming control of two-level voltage source converters interfacing photovoltaics. We first formulate grid-forming control objectives and constraints of voltage source converters and photovoltaics in a one-step optimal grid-forming control problem. Next, we leverage primal-dual dynamics to obtain a dynamic feedback controller that approximates the solution of the one-step optimal grid-forming control problem. Finally, electromagnetic transient simulations are used to illustrate the results.

Gross, Dominic↗

Beam breakup instability studies of powerful energy recovery linac for experiments

The maximum achievable beam current in an energy recovery linac (ERL) is often constrained by beam breakup (BBU) instability. Our previous research highlighted that filling patterns have a substantial impact on BBU instabilities in multipass ERLs. In this study, we extend our investigation to the eight-cavity model of the Powerful ERL for Experiment (PERLE). We evaluate its requirements for damping cavity higher order modes (HOMs) and propose optimal filling patterns and bunch timing strategies. Our findings reveal a significant new insight: while filling patterns are crucial, the timing of bunches also plays a critical role in mitigating HOM beam loading and BBU instability. This previously underestimated factor is essential for effective BBU control. We estimated the PERLE threshold current using both analytical and numerical models, incorporating the designed PERLE HOM dampers. During manufacturing, HOM frequencies are expected to vary slightly. Our study found no significant difference in BBU suppression for relative rms frequency jitters of 0.001, 0.002, and 0.005 for the same HOM. Introducing a jitter of 0.001 into our models, we found that the dampers effectively suppressed BBU instability, achieving a threshold current an order of magnitude higher than the design requirement. Our results offer new insights into ERL BBU beam dynamics and have important implications for the design of future ERLs. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Control Design for a Marine Hydrokinetic Cycloturbine Vehicle

Abstract Marine Hydrokinetic (MHK) cycloturbines generate sustainable power by exploiting tidal currents. By powering the turbines and using pitching foils for control, a vehicle comprised of MHK cycloturbines also has the ability to station keep and maneuver. The vehicle consists of four counter-rotating cycloturbines, with hydrofoils oriented perpendicular to the flow in a paddlewheel configuration. Lift and drag generated from these foils sum together to produce thrust. An experimentally tuned simulation model that solves the six-degrees-of-freedom rigid body equations of motion for the MHK vehicle subject to hydrodynamic, hydrostatic, and propulsive forces is used to aid the design of vehicle controllers. Global feedback controllers are initially designed by applying classical control methods to an approximate linear model of the system dynamics. A higher performing nonlinear controller is designed using the nonlinear dynamic inversion (NDI) method. NDI accounts for the nonlinearities of the MHK system and therefore is suitable for a wide range of operating conditions. The response of the classical and NDI controllers to speed, depth, roll, pitch, and yaw commands are evaluated and compared in simulation. The classical controller outperforms the NDI controller for small amplitude maneuvers, although the degradation with NDI is minor. However, in the nonlinear operating regime the NDI controller outperforms the classical controller and the classical controller exhibits instability.

Automation & Control Systems↗

Evaluation of ITER divertor shunts as a synthetic diagnostic for detachment control

Reliable diagnostics that measure the detached state of the ITER divertor plasma will be necessary to control heat flux to the divertor targets during steady state, burning plasma operation. This paper conducts an initial exploration into the feasibility of the divertor shunt diagnostic as a lightweight, robust, and real-time detachment sensor. This diagnostic is a set of shunt lead pairs that measure the voltage drop along the divertor cassette body, from which the plasma scrape-off layer (SOL) current is calculated. Using SOLPS-ITER simulations for control-relevant ITER plasma scenarios, the thermoelectric current magnitude along the SOL is shown to decrease significantly with the onset of partial detachment at the outer divertor target. Electromagnetic modelling of a simplified divertor cassette is used to develop a control-oriented inductance-resistance circuit model, from which SOL currents can be calculated from shunt pair voltage measurements. The sensitivity and frequency-response of the resulting system indicates that the diagnostic will accurately measure SOL thermoelectric currents during ITER operation. These currents will be a good measure of the detached state of the divertor plasma, making the divertor shunt diagnostic a potentially extremely valuable and physically robust sensor for real-time detachment control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Keras2c: A library for converting Keras neural networks to real-time compatible C

With the growth of machine learning models and neural networks in measurement and control systems comes the need to deploy these models in a way that is compatible with existing systems. Existing options for deploying neural networks either introduce very high latency, require expensive and time consuming work to integrate into existing code bases, or only support a very limited subset of model types. We have therefore developed a new method called Keras2c, which is a simple library for converting Keras/TensorFlow neural network models into real-time compatible C code. It supports a wide range of Keras layers and model types including multidimensional convolutions, recurrent layers, multi-input/output models, and shared layers. Keras2c re-implements the core components of Keras/TensorFlow required for predictive forward passes through neural networks in pure C, relying only on standard library functions considered safe for real-time use. The core functionality consists of ~ 1500 lines of code, making it lightweight and easy to integrate into existing codebases. Keras2c has been successfully tested in experiments and is currently in use on the plasma control system at the DIII-D National Fusion Facility at General Atomics in San Diego.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control and Real-Time Simulation of Microgrids with EV Fast-Charging and Grid-Forming Resources

Fast charging stations (FCSs) for electric vehicles (EVs) can behave as constant power loads, which is problematic for the operation of grid-forming (GFM) inverter-based resources (IBRs). To tackle this problem, this paper proposes a control suite that makes FCSs responsive to ac voltage and frequency disturbances. To test the performance of the FCS controls, the paper also sets forth theory to compensate for time-delays appearing in the real-time simulation of microgrid models divided into several central processing units (CPUs). Furthermore, these contributions are showcased via multi-CPU real-time simulations of a faulted microgrid having EV FCSs and GFM IBRs powered by photovoltaic solar arrays as well as power hardware-in-the-loop experiments. These contributions are significant to address NERC recommendations and IEEE standards.

14 SOLAR ENERGY↗

Plasma shape and position control development for NSTX-U using the GSEvolve plasma simulator

NSTX-U discharges have been reproduced using the GSEvolve plasma simulator in order to improve their control and reduce oscillations during the plasma current (Ip) ramp-up phase, and with the ultimate goal of enabling reliable H-mode access with a double-null shape at high elongation, low internal inductance, and high plasma performance. The control objective is to eliminate undesired oscillations in the plasma shape and vertical position that start when the plasma diverts during the Ip ramp-up phase, and that happened recurrently during the first NSTX-U experimental campaign. Model-based control solutions have been developed, including alternative H-mode access recipes and a Multi-Input Multi-Output (MIMO) decoupling controller. These solutions have demonstrated their capability to reduce or eliminate the aforementioned oscillations in GSEvolve simulations, enabling reproducible H-mode access. The results of this work aim to inform NSTX-U experimental operations on potential control developments to maximize its scientific output, and highlight the powerful capabilities of high-fidelity control-simulation frameworks like GSEvolve.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.